analytical bulk flow distance FLOW level pressure temperature industrial communication

Similar documents
Level and Flow Measurement. High Accuracy OCM. FlowCERT, DUET and Speedy

Advanced Pump Controllers

Blackbox Controllers:

Level and Flow Measurement. Ultra Range. Ultra 3, Ultra 5 and UltraTwin

Level and Flow Measurement. Blackbox

Level and Flow Measurement. Flow Pulse

SITRANS L Level instruments

Level and Flow Measurement. Flow Pulse

Engineering Specifications HydroRanger 200. Multi-Functional Level Control System

ULTRA 3 INSTRUCTION MANUAL

Continuous level measurement Ultrasonic controllers

Level instruments. Continuous level measurement - Ultrasonic controllers SITRANS LUC500. 5/146 Siemens FI

FLOWMETER Ultrasonic flow transmitter

MicroFlow MicroFlow-i. Non-contacting Microwave Liquid Velocity Sensors

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Level and Flow Measurement. IMP Range

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Ultrasonic Flow Meter Brochure

Configuring the MultiRanger 200 to measure open channel flow. Specific parameter setting to configure the following primary measurement devices:

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

GS828-H. GPRS Data Logger

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

MID approval no. DE-08-MI004-PTB004 Date of release

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

I SCO 4100 SERIES F LOW L OGGERS The Ultimate System for Multi-Site Flow Monitoring and Analysis

LAUREL ELECTRONICS, INC.

dual-line 6-dIGIt process MeteR

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

Level Measurement Continuous level measurement - Ultrasonic controllers

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

SC100 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

DCT7088 Portable Digital Correlation Transit Time Flowmeter

Level Measurement Continuous level measurement Ultrasonic controllers

HL Series Ultrasonic Level Meter

blackbox 133 (UL) INSTRUCTION MANUAL

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Gladiator Acoustic Switch Series

SWING Ultrasonic Level & Flow Controller

Vantage Eastech Badger ULTRASONIC FLOW MEASUREMENT A NEW OPEN CHANNEL FLOW AND LEVEL METER THAT CAN PAY FOR ITSELF IN ONE WEEK ACCURACY 0.

CALEC energy master The benchmark in energy measurement

Large DIspLay process Meters

Vantage Eastech Badger A NEW STANDARD IN OPEN CHANNEL FLOW AND LEVEL MEASUREMENT FLOW TECHNOLOGY GROUP

VANTAGE 2200 Ultrasonic Open Channel Flow & Level Meter

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Multi-Point Gas Detection and Control System

Flow measurement in open channel. Portable Area-Velocity Mainstream EH7000 P. Ultrasonic Area-Velocity Flow meter MAINSTREAM 7000

AccuTank ULTRASONIC LEVEL MONITORING SYSTEM

Multi-Point Gas Detection and Control System

GS828. GPRS Data Logger

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

blackbox 130 INSTRUCTION MANUAL

... f l o w measurement & control...

MonoScan User's Manual

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

/8 DIN Universal Process Indicator

DUAL RANGE ACCURON 7200 CARTRIDGE METERS. eastech

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

Trident and Trident X2 Digital Process and Temperature Panel Meter

Data sheet deltwavec-f

Multi-Point Gas Detection and Control System

SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

Level Measurement. Continuous level measurement - Ultrasonic controllers. SITRANS LU01 and LU02. 5/156 Siemens FI Overview.

Series DMHF Heat Meter

Series TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Conductivity Transmitters

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

Meter Scanner & Controller

DMTFP Portable Ultrasonic Flow Meters

DIGITAL METERS Universal Analog Input Process Meter With Rate/Totalizer/Batch Control Features Instruction Manual

The Model 464-BC Monitor controls and stores flow data from Marsh- McBirney Flo-Dar sensors. A portable computer and Flo-Ware software is used to

Hydrostatic filling level sensor HFB C4 / R / MD

Model DDMC Digital Meter/Controller

MPU 600 Series B. Ultrasonic Gas Flowmeter. Specifications. Features. Applications. Operating Specifications. Principle of Operation

Digital Panel Meters

MPV. Process Panel Display. Dual-Line Rate and Total

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

Portable Dual Frequency Doppler Flowmeter

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

Level and Flow Measurement. dbi Transducers. HART and Profibus PA Intelligent Transducers

OPERATING INSTRUCTIONS

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

FM8000 Ultrasonic Open Channel Flow Meter

Intrinsically Safe Area Velocity Flow Meter

VOLUCALC RT. User Manual. Real Time Volumetric Flow Meter, Derived Flow Based Flow Meter And An Open Channel Flow Meter

DS October MAXIM 1010 Controller

Gladiator. Vibration Smart Switch Series. Data Sheet. A Higher Level of Performance. A level switch for liquids and solids.

Mobrey blanket level monitoring MSL600 for clarifier and settlement vessels

Flow Measurement SITRANS F US Clamp-on

Dupline Fieldbus Components

PD6200 / PD6300. PROVU Dual-Line 6-Digit Flow Rate/Totalizers SERIES. Precision Digital Corporation

Power Meter PowerMonitor 500

Transcription:

analytical bulk flow distance FLOW level pressure temperature industrial communication

LEVELWIZARD II OPEN CHANNEL FLOWMETER The LevelWizard II Open Channel Flowmeter is non-contacting and operates on the principle of timing the echo received from a pulse of sound in air, this provides a highly accurate calculation of flow from the measured head preceding the primary element. Flow calculations to the British Standard BS3680 are available within the software together with calculations for a wide variety of other primary elements. Also available within the unit is a customised 32 point calibration routine which also permits the flow measurement of non - standard flumes and weirs. For channels without primary elements the LevelWizard II even offers the facility of connecting a Doppler Velocity Sensor (available from isolv) and performing the calculations of Flow Q = Velocity x area for a wide variety of channel shapes. Features / Benefits The LevelWizard II Open Channel Flowmeter can show level, space, distance, head or flow on the display. The relays can be programmed to activate alarms, pump starters, or other control equipment. There is an isolated 4-20 ma output that can be connected to a chart recorder or PLC, to monitor level space or distance, independently from that shown on the display. There is an RS232 port, so that the LevelWizard II Open Channel Flowmeter can be operated remotely by a PC or other equipment. The LevelWizard II Open Channel Flowmeter can be programmed either by the built-in keypad or by using the Remote Communicator (optional) or by PC via the RS 232 Serial Interface (optional). One Communicator can program many isolv units. All the parameters are stored in non-volatile memory, so the information is retained in the event of power interruption. A second backup copy of all parameters can also be retained in the LevelWizard II Open Channel Flowmeter, in case a previous set of parameters needs to be restored. Application It has been specifically designed to measure influent and effluent water flow from all types of municipal and industrial treatment plants. 2

Exponential Devices If the primary measuring device is a simple exponential device then an exponent value is required. The LevelWizard II Open Channel Flowmeter will automatically enter the exponent value for the device chosen as detailed in the table below. Exponent Type Suppressed Rectangular Weir Cipolletti (Trapezoidal) Weir Venturi Flume Transducer / Echo Parshall Flume Leopold Lagco Flume V-Notch Weir Other As per manufacturer 3

Open Channel Flow Measurement The LevelWizard provides flow indication, totalization of flow and outputs for remote alarms. It can be used in a wide range of flumes and weirs in channels and overflow structures. Open channel flow monitoring in a typical flume V-Notch Weir Flow Monitoring 4

Specifications Physical Weight Nominal 1 kg (2.2 lbs) Transducer Cable Three-core screened, can be extended with 2 or 3 core screened Maximum Separation 500 m Cable Entry Details 10 cable entries - 5 x M20, 1 x M16 underside, and 4 x 18mm at rear Enclosure 240 x 184 x 118 mm, Polycarbonate, flame resistant to UL94-5V IP Rating IP 65 Min & Max. Temperature (electronics) -20 C to 55 C Performance Accuracy Resolution Maximum Range Minimum Range Reading Response +/-0.25% of the measured range or 6 mm (whichever is greater) 0.1% of the measured range or 2 mm whichever is greater) 6 meters (db6 transducer), 10 meters (db 10 transducer) Dependent on transducer Fully adjustable Echo Processing Description Outputs Analog Output Digital Output Optional Volt free contacts, number and rating Display Programming On-board Programming PC Programming Programming Security Programmed Data Security Data Logging (Optional) Supply Power Supply Patented DATEM (Digital Adaptive Tracking and ECHO Mapping) Isolated output 4-20mA or 0-20mA into 500Ω (user programmable), 0.1% resolution Full Duplex RS232 via RJ11 port RS485 conn for Modbus with Profibus DP V0 or V1 options 5 form C ( SPDT ) rated at 5A at 115 Vac 2 row LCD display showing programmed scale, plus bar graph with direction indicators, remote communicator identifier, program/run/test mode indicators and relay status Integral keypad Via RS232 (RJ11 port) or RS485 (optional) Via Password (User Selectable and Adjustable) Via non-volatile RAM, plus backup Via RJ11 port has 256kb giving 1 year at 15 min intervals (uses PC Suite software) 85-264Vac, 50/60Hz, 22-28Vdc 5

Standard, Short and Medium Range db Transducer Innovative designs has led to the db range of transducers being quite unlike anything seen in ultrasonic level measurement before. Previously, there were high voltage, frequency dependent transducers, susceptible to electrical noise and requiring special, protected interconnection cables, or weak low voltage transducers designed with flammable atmosphere approval and not application performance in mind. The innovative transducer design, combining low power, permitting optional certification to intrinsic safety standards and utilising standard screened cable, is capable of the power and range necessary to achieve industry s demands. The isolv-pulse range of db transducers has, as standard: isolv-pulse db Transducer db6 Short range liquid level measurement PZT ceramic transducer element db10 Liquid and solid level measurement PZT ceramic transducer element 6

Dimension (In mm) db 6/10 Housing Material: Valox 357 db 15 Housing Material: Valox 357 Cable Gland Knock-outs Bottom Face: 1 off 16 mm 5 off 20 mm Back face 4 off 18 mm 7

SALES AND SERVICE CENTRES REGIONAL NETWORK CHINA INDONESIA SINGAPORE - HEAD OFFICE FLOTECH CONTROLS PTE LTD Certificate SG95/04276 Certificate SG13/04547 MALAYSIA 30_0414