TMS Office and TMS Applications Dear TMS users,

Similar documents
Amberg ScanControl. Easy pointcloud acquisition. User manual. Amberg Technologies AG Trockenloosstrasse Regensdorf Switzerland

Product Leica Geo Office 8.2 Date October 26th, 2011

Leica Captivate. Software Release Notes. Field Controllers: CS20, CS35 Total Stations: TS16, TS60, MS60. Release date 5 th March 2018

Leica ScanStation C10 The All-in-One Laser Scanner for Any Application

Leica Viva SmartWorx Viva on TS

TcpTunnel. Setting Out and Surveying for Tunnels. Introduction. Project Definition

Leica Captivate. Software Release Notes. Field Controllers: CS20, CS35 Total Stations: TS16, TS60, MS60, TS13 GNSS Sensors: GS18 T

Leica Viva Imaging Enrich your Surveying Workflow

Increase Field Survey Efficiency by Merging Technologies in NOVA MultiStation. Vincent Lui Leica Geosystems Ltd

Marc De Bruyne 3D Design Improvement Leader, DOW Chemical

Leica Captivate. Software Release Notes. Field Controllers: CS20, CS35 Total Stations: TS16, TS60, MS60. Release date 1 st December 2017

Reality Capture using: RPAS Technologies & Image Laser Scanners

Leica ScanStation C10 Equipment List

Version 6.2 Release Notes February 2017

Trimble RealWorks. What s new in version 9.0

Reality Capture. Customer Case

Leica FlexLine Frequently Asked Questions

icon office release of version

Leica Scan Station P20 User Manual

X PAD Construction 2.5.5

Leica Viva TS11 & TS15 Hardware

OBJECT MANAGER PACKAGE USER S GUIDE

3D-Laser Scanning and Surveying Collide. >> By H. Tate Jones, LS

What s new in Inspector SCA & FI software update May 2017

Product Leica Infinity. Date Nov 30 th, From Kevin Hanson

Evidence Recorder Release Notes

Leica Viva GS14 Designed for Performance

What s New In SA CHAPTER

SmartWorx Viva How to Record Static Observation Data On-Board GS Receivers Operating in Base Mode

Viva TPS. TS11/15 Total Stations Connect the CS Controller and TS15 with Bluetooth. October Summary

Release Notes. Release Date: March, 2018

Leica RX1250 & TPS 1200 Robot

Version 6.2 Release Notes October 2016

Leica ScanStation C5 Scalable Laser Scanner

QuickStart Guide: Leica Cyclone REGISTER 360

Product Leica Infinity. Date July 13 t, From Kevin Hanson

Leica Geosystems QuickStart Guide

Instrument Interface to. LEICA TPS mid-range series (300, 400, 700, 800 and FlexLine)

RELEASE NOTES TRIMBLE REALWORKS SOFTWARE VERSION System requirements New Features and Changes

Basic Software Maintenance. Ham Station Ultra Software Package

FieldGenius 2005 Ver 1.2 MicroSurvey Software, Inc. 2005

Future Design Controls, Inc. VR Series (VR06 & VR18) Firmware Release Notes; v0.94 to v2.37

Version 6.1 Release Notes September 2016

Our Challenge : To manage an increasingly complex world!

V-STATS 4.01 HB g Copyright: SenTec AG. Installation Manual. for V-STATS with. V-CareNeT Package. Copyright:

Leica FlexField plus & Leica FlexOffice A Perfect Match

Leica icon Series. Licence Installation and Activation Guide. Version 1.1 English

What is your PC Operating System? Windows 98 Windows 2000 Windows NT Windows ME Windows XP. SRAM Card Only

FARO Laser Scanner Focus 3D X330 Demonstration Day

Leica Viva TPS October 2010

Gregory Walsh, Ph.D. San Ramon, CA January 25, 2011

Softrock GeoMos Manual For AutoSlope Users

Terrestrial Laser Scanning assignment

Leica Cyclone 5.4 Technical Specifications

GeoMax FieldGenius for Zipp20 Quick guide

Terrestrial 3D laser scanning Practical aspects

BIM & Digital Transformation Scotland Live 2018 Capturing 3D Reality at the push of a button

DeltaLINK 3 Release Notes

ZED Tunnel Guidance Ltd

Leica LAS EZ. Release Notes V Ryf AG Bettlachstrasse Grenchen tel fax

Cox Business Online Backup Administrator Guide. Version 2.0

Solution Composer. User's Guide

Leica Viva GS14 Designed for Performance

RMS Mini Wireless Data Logger

12D LEAST SQUARES NETWORK ADJUSTMENT FROM LEICA 1200

Trimble Survey Controller. Release Notes

Leica DFC Camera. Software Release Notes V 7.4.0

Leica BLK360 Questions & Answers. Vers

Leica High-Definition Surveying Systems. Leica HDS3000. The Industry Standard for High-Definition Surveying

The Leica HDS Family. The Right Tool for the Job HDS3000 HDS2500 HDS4500. Cyclone & CloudWorx. Press the QuickScan button to define the field-of-view.

USTER QUANTUM EXPERT 3

Getting Started and System Guide. Version

Quick Installation Guide T-Base Professional

SMS Basic and Advanced Version x Release Notes. Contents:

SDB 6.4. User's Manual

Using QNAP Local and Remote Snapshot To Fully Protect Your Data

Wireless Activity Tracker. Product Manual

Leica FlexLine TS06plus Top Precision meets High Efficiency

Simplicity is the new black: The BLK360 story

Intech Micro 2400-A16-SD

Perceptive Intelligent Capture. Product Licensing Guide. with Supervised Learning. Version 5.5 SP2

2009 Davis Instruments Corp. All rights reserved. Information in this document is subject to change without notice.

IP-S2 HD. High Definition 3D Mobile Mapping System

LEICA T1800 TC1800 TCA1800

inpo2 Release Notes v October 11, 2017

USTER QUANTUM EXPERT 3 ULTIMATE

Storing and Organizing Your Digital Images

Setting up a secure VPN Connection between the TS Adapter IE Advanced and Windows 7

Leica FlexLine TS09plus Full Precision at High Performance

INTRODUCTION SETTING UP USERS AND SECURITY GROUPS

3D Terrestrial Laser Scanner Innovative Applications for 3D Documentation

Calendar Guide: Exchange (Outlook) -> Google. How to manually transfer your Exchange (Outlook) calendar over to Google Calendar

User Addendum User Box Scan support on the Fiery E C-KM Color Server, version 1.1

tibase Intelligent data management for titration


How to download a program (IQ POS, IQ Business, IQ Enterprise, IQ Payroll, IQ Restaurant from our website (

Where s Your Third Copy?

BERNAFON FIRMWARE UPDATER

TA Instruments New Features in DSCRun TM Software

UNIVERSAL SOFTWARE. Universal Software. Data Sheet

Transcription:

Amberg Technologies AG Trockenloostrasse 21 CH-8105 Regensdorf-Watt Switzerland Phone +41 44 870 92 22 Fax +41 44 870 06 18 info@amberg.ch www.amberg.ch/at Date: July 12 th, 2012 No: 07-2012 From: Product Management Tunnel Surveying Systems To: TMS Distribution Partners / Customers No. of pages: 6 TMS Office 1.9.8.3 and TMS Applications 4.05 Dear TMS users, We would like to inform you that new versions of TMS Office and TMS Applications were released. Please find the details about the new features, changes and their benefits below. Customers with valid maintenance and support contracts can download the latest software release from http://www.ambergtechnologies.ch/downloads/tunnel-surveying-tms/swdescriptions/. If you don t have an active Support contract you can contact Amberg Technologies AG (support.tunnel@amberg.ch) or your local dealer. 1. TMS Office 1.9.8.3... 2 1.1. General... 2 1.2. TMS ProFit... 3 1.3. TMS Tunnelscan... 4 1.4. TMS Scan Control... 4 1.5. Bug fixes... 5 2. TMS Applications 4.05 (Leica Viva)... 6 2.1. General... 6 3. TMS Applications 3.33 (TPS1200, TS 30)... 6 Release Note 02/2010

1. TMS Office 1.9.8.3 1.1. General Export of theoretical sections to Amberg Geotechnics The last missing part to transfer the complete project data in a fast way from TMS Office to Amberg Geotechnics has been completed. With the new TMS Version you are able to export also the theoretical sections to other external software. You can find the export under Project Export ASCII Theoretical sections. The export will create an ASCII file with start and end station of every section. This file can be imported in Amberg Geotechnics with the import button under the theoretical sections in the selected construction stage. Export from TMS Office Import in Amberg Geotechnics Release Notes 02/2012 Page 2 of 6

1.2. TMS ProFit Date and time from Windows calendar for all ASCII imports For the ASCII imports of measured points from total station and point cloud there is now a default timestamp provided. For these imports in ProFit the current date is used. This saves the time for manual input of the date and the time during the import procedure. This improvement is also made for the ASCII import of scan data and for the PTS import. Of course you can overwrite the default date during import. ASCII imports in ProFit Default import date set to current date Release Notes 02/2012 Page 3 of 6

1.3. TMS Tunnelscan Repositioning of FARO scans possible Since this update it is possible to reposition Faro Scans that were measured with the APM method. Before, you would have to keep a copy of the raw Faro Scan in a separate folder in case a new position (for example after a network measurement) was needed. From now you can do the position directly with the positioned scan in TMS Office and save the disk space for the raw scan copy. Support of new laser scanner models for processing: Z&F Imager 5010 and Leica HDS7000 In the new version of TMS Office it is possible to use scans measured with the new HDS7000 and Z&F Imager 5010 for the processing. For these scanner models the same workflow as known from older Z&F or Leica scanners can be used. The new Scanner support also the APM position method and the import of positioned files form external software over targets. The workflow is exactly the same for all scanners of this type. 1.4. TMS Scan Control Support of new laser scanner models Z&F 5010 and Leica HDS7000 for measurements The new Scanner family from Z&F and Leica are supported. With the new scanners it is possible to measure with APM in the tunnel with the same workflow as from all other scanner types of this family. Scanner in tunnel with APM positioning method Phase-out information for HDS 4500 Scanner Types With the new support of the Z&F 5010 and Leica HDS7000 it was no longer possible to support the HDS4500 for ScanControl. The measurement with this scanner is supported up to version 1.6.9.10. You can use this version for the measurement in the tunnel. The positioning and the processing of HDS 4500 is still possible with the new TMS version 1.9.8.3! Note! Only the measurement with HDS 4500 is not possible anymore with versions after 1.9.8.0. the positioning and data processing of scans made with HDS 4500 is still fully supported also in the new version of TMS Office. Release Notes 02/2012 Page 4 of 6

1.5. Bug fixes TMS Office: Freezing effect with Win7 Home Edition (after Win7 Update) During the last weeks Windows 7 installed an update on your computer. Some customers with Windows7 Home Edition had troubles with the freezing of TMS Office. This problem is solved with the new TMS Versions. TMS Office: Project loosing theoretical section definition after opening project without dongle fixed Sometimes it happened that after the opening a project without a valid dongle in demo mode, the theoretical sections of the project was overwritten. This problem is solved with the new TMS version. TMS ProFit: Merge profiles in shaft After the merging of some certain shaft profiles the merged profile was mirrored displayed. The merge of profiles is now working correctly also for shaft profiles. TMS ScanCloud: Incorrect display of slider in Map view when working in imperial units The slider is displayed in the correct position also in case the software works with imperial units. Release Notes 02/2012 Page 5 of 6

2. TMS Applications 4.05 (Leica Viva) 2.1. General Support Firmware Leica 4.3 The TMS Application version 4.05 supports the newest Leica Firmware 4.3 for Leica Viva instruments. Support of RH16/CTR16/TCRS29 BT With the new Leica Firmware also the new Radio modems RH16/CTR16/TCRS29 are supported. (After the testing in the tunnel we can recommend to use this RH also in the tunnel environment.) New Battery Management for Viva Total Stations The implementation of an new power management for external power sources was implemented. The old problem that a total station on a console starts only with a TCPS is with this update solved. From now on, the internal battery in the total station works like a temporary power supply. In case external power is lost, the instrument switches to the internal battery. As soon as the electricity comes back, the total station uses the external power source again. The instrument will continue working normally during the outage of the external power source. With this improvement you can use the TPS with a radio handle easily as an motor laser. The manual switch on with this combination and the sometimes difficult access to the total station after the loss of the power source is not needed anymore. This improvement makes the system also more compact and reliable. 3. TMS Applications 3.33 (TPS1200, TS 30) Support Firmware Leica 8.5 The TMS Appl. version 3.33 supports the newest Leica Firmware 4.3 for Leica 1200 instruments. With this Leica firmware you are able to use the new RH16/CTR16/TCRS29. You can find the new radios as known under the radio settings of the TPS1200. Yours sincerely, Oliver Schneider Product Manager Tunnel Surveying Systems Release Notes 02/2012 Page 6 of 6