ICS Entrance Management Sign Installation Guide. Version 1.0

Similar documents
When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Solar Combiner Enclosure

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

EX-RC1 Remote I/O Adapter

InView Marquee Message Display

High Speed Remote I/O Module

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

C-POWER AC AUTOMATIC CONTROL

Installation Notes TII Model 341 Protector

The information in this chapter will enable you to: Understand the product's basic functions & features

Model HM-535 Power Supply Installation and Service Instructions

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

PXC Compact Unitary Equipment Controller (UEC)

Meter Enclosure and Equipment Standards

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Series Amp Pad Mount Quick Connect Input and Output Power Panels

User s Manual. LumiVision series. A Designer s X-ray film illuminator. Walnut, CA U.S.A. By LCD TV Technology

Temperature. Power requirements. Weight. Dimensions

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

Installation. MGE Galaxy 3500 and Smart-UPS VT. Maintenance Bypass, Distribution and Transformer Cabinet

EX-RC1 Remote I/O Adapter

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

Specialized Lighting Solutions, Inc. SLS DALI CONTROLLERC

PanelView Plus/VersaView CE Terminals and Display Modules

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Micro-OPLC Installation Guide

PV Rapid Shutdown device

Series Amp Quick Connect Input and Output Power Panels

Basketball Shot Clock Set LX2180 Manual

Avanti HP Series Centrifuges Preinstallation

INSTALLATION INSTRUCTIONS

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

SAVE THESE INSTRUCTIONS

PowerLogic High Density Metering System 1-Meter Enclosure

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

EX-RC1 Remote I/O Adapter

V E1B Snap-in I/O Module

Satellite INSTALLATION GUIDE

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT

OPLC Installation Guide

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

ORB TM 4-20 ma Input Box Installation & Operation Manual

Site Preparation CHAPTER

Full HD Speed Dome IP Camera

The identified danger could cause physical and property damage.

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

MicroTech II TM Remote I/O Panel Installation Manual

Instruction Manual: IM E

V E2B Snap-in I/O Module

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

Vision OPLC V TR6/V350-J-TR6

Specifications, Installation, and Operating Instructions

V E1B Snap-in I/O Module

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP

Staff Workstation Model 795

UniStream HMI Panel. CPU-for-Panel

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

Now with Picture Memory

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

7" Touch Screen Display

icp installation guide

Multi Unit Enclosed Meter

INSTALLATION INSTRUCTIONS

HT2000 Transverter Installation & Operation Manual

E-Series Site Preparation Guide

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

V E2B Snap-in I/O Module

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Hardware Installation. Tracer MP581 Programmable Controller CNT-SVN01C-EN

H Manual Stretch Wrap Machine uline.com FILM ROLL CAPACITY TECHNICAL DATA ELECTRICAL SPECIFICATIONS TURNTABLE SPECIFICATIONS

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

M215 (M215-60) Safety

Breaker Panel Technical Practice NPDRP1114

Cobalt 8 Pre-Installation & Site Preparation Guide

MAXIMA+ Series Rotary Level Indicator

Model 7416LED

SECTION PANELBOARDS

User safety and equipment protection guidelines

Transcription:

ICS Entrance Management Sign Installation Guide Version 1.0

Thank you for purchasing your new ICS Entrance Management System (EMS) from Innovative Control Systems, Inc. Installation Overview This document was written for technicians and electricians installing the ICS Entrance Management System and integrating it with the network. A thorough understanding of electrical wiring, installation, codes, and safety protocols is required. No prior experience installing the EMS is necessary. System Components Included ICS Entrance Management System base and display Cat 6 Shielded Network Cable NOTE: The ICS Entrance Management System is not a stand-alone system. WashConnect and a connection to the network is required. This guide should be supplied to the electrician prior to the installation of conduits and wiring to ensure the ICS Entrance Management System is installed properly. Faulty installations are the major cause of system malfunctions. The ICS Entrance Management System must be installed exactly as described in this manual to ensure its reliability and safe operation. WARNING: Failure to properly install the ICS Digital Menu system will void the warranty. The ICS Entrance Management System was designed at the request of many car wash operators. While the 42 Entrance Management System was retired, many of the features were integrated in the new design: View and manage StackNControl. Set retracts anywhere in the tunnel. Display (or hide) purchased wash services. Supports graphics, animations, and instructional videos. Cancel and Fire Rollers quickly. Sends entrance management video when firing the roller manually or automatically from tire signals. Automatic, computer controlled, or manual firing of the outputs. Manage two tunnels with two Entrance Management units. By reading the information and performing the procedures in this installation guide, you should be able to install: The ICS Entrance Management System base and display The ICS Entrance Management System system-level wiring The ICS Entrance Management System communications wiring Version Considerations This version 1.0 of the installation guide, release on April 12, 2018. WashConnect management software version of 1.4.5 or greater is required. Site Planning Careful planning for the layout of the site will help eliminate possible problems with the start-up of your system and will ensure continued, reliable system operation. In determining the location stage, keep the following objectives in mind: The ICS EMS must be located so that conduit connections can be easily made. Enough clearance is needed for the door to open easily without interfering with entrance and exit from the equipment room. This clearance should be available both in front of the door which opens from the back of the unit, as well as to the right of the unit. This minimum will give enough clearance for the door to swing out and be fully opened. WARNING: A minimum clearance of 36 is recommended for the door swing. 2

Interior Detail Exterior The 46 touch screen display is a 1,920 1,080 color monitor. Figure 1. Interior detail with the Heat Exchanger Figure 2. Entrance Example Hardware Specs An industry-leading 46 display, that is fully readable in bright daylight. The unit has been designed to operate in the temperature range of -20 F to120 F (-28 C to 48 C). The hinged panel design is mounted on a base that is bolted to the concrete floor at 286 lbs. The unit measures 31 W 75-3/4 H 15-1/4 D with a hinged-panel door. If looking at the front of the unit, hinges are on the right-side. The door swings open in the back of the unit from left to right. Dedicated universal power supply (UPS): 1500VA/865 Watts output capacity. Planning for Installation Prepare to have all the necessary tools and parts. Ensure permanent connections are performed by a licensed electrician who must comply with all the National and Local recommended standards. Wiring can be contained in rigid PVC conduit or metal conduit. High-voltage (AC) and low-voltage (DC) must not be combined in a common conduit, junction box, or wire trough. Power for the ICS Entrance Management unit and any peripherals must come from the dedicated UPS, as supplied by ICS, and must be properly grounded. Check through all shipping containers before disposing of them looking for possible manuals, cables, connectors, etc. Warning Markings See the specification label and marking on the inside of top left enclosure door from the interior service area.! The symbol on the left is labeled on equipment and hardware to indicate one should consult accompanying documentation before proceeding. Related Documents WashConnect Web Help (StackNControl Menu only) The following document is available for further reference: 3

Equipment Dimensions When mounting the unit, minimum clearances must meet local recommended standards. Dimensions Measurements Notes Width 31 in / 78.74 cm Height 75 3/4 in / 192.40 cm Depth 15 1/4 in / 38.73 cm Viewable Touch Screen 46 in / 116.84 cm Weight 286 lbs / 129.7 kg Operating Temp. Range -20 F to 120 F -28 C to 48 C Frequency 50/60 Hz Supply Voltage 110 VAC ± 10% Intended for permanently connected supply. Max. Current 6 Amps @ 120 V AC 6 Amps @ 120 V AC Power for the Entrance Management System Heat Exchanger Power Supply 20 Amps Power must come from a dedicated 20 Amp breaker. IPX RATING NEMA 4X Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, and hosedirected water from water jets at any direction; and that will be undamaged by the external formation of ice on the enclosure. Including protection against corrosion. Table 1: Auto Sentry Petro Equipment Dimensions, Measurements, and Ratings NOTE: Every tunnel setup varies, but typically, a minimum of 44 from the inside edge of the conveyor to the edge of the ICS Entrance Management base plate is necessary to allow safe clearance for the oversized vehicles with oversized mirrors from the equipment. 44 Conveyor Figure 3. ICS Entrance Management Location of Base 4

Mounting 1. Locate the actual template you received with your ICS Entrance Management System. 2. On the template, cut out along the dotted lines which is the open space that the conduits will pass through. 3. Place the template over the conduits, and adjust to the center line shown on the template. 4. After securing the template to the concrete pad with tape, mark the centers of the of the six holes with a nail, drill bit, or marker so that when the template is removed, some type of mark will be left behind identifying the center of the hole. 5. Drill the appropriate holes necessary for the anchor bolts used. 6. Install the anchor bolts. 7. Run the wires up through the opening in the base of the ICS Entrance Management Unit. 8. Place the ICS Entrance Management System onto the anchor bolts and secure it with washers and nuts. 31" Mounting Template Base Plate of the ICS Digital Menu 2 ½ 7 ½ 13" 4X ¾ (2) 3" x 3" 3" CONDUIT OPENINGS 16" APART Use ½ Bolts 1" 1" Power Requirements Power for the ICS Digital Menu comes from a dedicated 110V circuit from the ICS power distribution box. An additional dedicated 110V circuit powers the heat exchanger. This additional circuit comes from the site s main service electrical panel and not from the ICS power distribution box. 8" Base Plate thickness is ¼ A separation of 120 V AC and 24 V AC shall be maintained for all field-wiring circuits. All 24 V AC circuits must be supplied by a class-2 transformer, which is to be provided by the electrician. An electrician must determine proper size of transformer, depending on total required power consumption. The ICS Entrance Management unit must be properly grounded. 6" 2 ½ Figure 4. ICS Entrance Management Mounting Footprint Conduit Run Guidelines Use wiring channels inside ICS Entrance Management System unit (left and right sides) to contain the wires. Run a 14 3 cable from a UPS output to the 120 V AC terminal block. The terminal block is labeled with L for Line and N for Neutral. There is a mechanical ground lug located in the lower-right corner near the AC terminal block within the box. It is labeled with the universal ground symbol. All conduit runs should meet national and local recommended standards. Conduits shall be properly connected and securely fastened to the units with listed conduit hubs, and should be tightened to the torque specs of the manufacturer. Tighten all wires on the circuit board terminal blocks to 15 inch-pounds. Over-torquing may cause breakage. All conduit must be rigid PVC or metal. The ICS Entrance Management System has been designed with environmental controls to operate inside the wash tunnel. 5

Site Grounding Considerations The ICS Entrance Management System and peripheral equipment must be properly grounded. Recommended and Accepted Grounding Methods Proper system grounding is an extremely important part of the system installation. Grounds for all system devices should be wired to the main service electrical panel ground bus bar which, in turn, should be grounded to a ground rod. A conduit ground does not provide a sufficient ground. It is recommended that the neutral and ground bus bars be bonded together when it is not prohibited by local codes. The universal ground symbol identifies the grounding lug connector located inside the lower-right hand corner of the ICS Entrance Management System unit. A second ground is marked. This is the dedicated 110 V line for the heat exchanger. WARNING: Improper grounding will void equipment warranty. Ground wire must be connected to the ground lug. Failure to properly ground the unit could result in unit failure and/or bodily injury. Wire Gauge and Conduit Size When planning the orientation of the wiring runs, follow the applicable ICS wiring diagrams and consider the layout of the components at the site. To determine conduit size needed, see the table below for more information. 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 AWG 14 13 24 39 69 94 154 AWG 12 10 18 29 51 70 114 164 AWG 10 6 11 18 32 44 73 104 160 AWG 8 3 5 9 16 22 36 51 79 AWG 6 1 2 6 11 15 26 37 57 AWG 4 1 1 4 7 9 16 22 35 AWG 3 1 1 3 6 8 13 19 29 AWG 2 1 1 3 5 7 11 16 25 AWG 1 1 1 1 3 5 8 12 18 Table 1: Number of Wires (THHN) in a Given Conduit Size! High-voltage (AC) and low-voltage (DC) must not be combined in a common conduit, junction box, or wire trough. 6

Power Wiring The terminal contains a power adapter and two 6 Amp @ 120 V AC breakers, ground, and neutral block for termination. A heat exchanger is installed inside the door. Heat Exchanger Figure 5. AC Power Terminations Figure 6. Heat Exchanger 7

Communication and Power Wiring Plan This section includes information on power wiring and low-voltage communications wiring for the ICS Entrance Management System (EMS). The following is only a sample drawing of the Low Voltage wiring for the EMS. See your individualized ICS System Installation Drawings for your car wash layout. Communications equipment signal wires must be run in separate rigid PVC or metal conduit, separate from any power conduits. ICS POWER DISTRIBUTION BOX ENTRANCE MANAGEMENT MAIN SERVICE ELECTRICAL PANEL 16-PORT 100 BASE-T WALL PLATE AT SERVER COMPUTER ICS SUPPLIED 14/3 SHIELDED Figure 7. Communication and Power Wiring Layout SITE SUPPLIED 3-12 Ga. THHN FROM A 20 AMP BREAKER 110 VAC ± 10% Technical Support Innovative Control Systems provides a toll-free number for customers and installers who have questions pertaining to the installation: 800-246-3469 8

Parts Identification This section is for part identification of the ICS Entrance Management System components. Front View Interior of Door Panel Exterior of Door Panel Figure 8. Entrance Instructions Figure 9. Heat Exchanger Figure 10. Heat Exchanger Heat Exchanger Board, Graphics Card, and Motherboard Network Port on Motherboard Figure 11. Heat Exchanger, Graphics, and Motherboard Figure 12. Network Port on Motherboard 9

Using the Entrance Management Sign The Entrance Management Sign plays an Entrance Management video on what to do after driving on the conveyor. It also has the ability to control the Stack Management on the Touch Screen. At the bottom of the screen, the customer can view the wash services purchased. See WashConnect Web Help for more Stack Management information. Stack Management (WashConnect) Top Brus.II Retract Wr p Rotr.ict. Tiro St11no Rc I LHaRetract ubtot I $10.00 so.oo $10.00 Figure 13. Stack Management Screen on the Entrance Management Display 10