Partner conference The digital revolution

Similar documents
Integrated Control Panels Utnytt dine digitale muligheter Basic Automation TIA Portal. Siemens AG 2017

CP-2 What s New in Industrial Controls Presented by Jim Sirois Manufacturing in America March 20-21, Unrestricted Siemens 2019

Safety is a SIRIUS business

SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

SIRIUS Overload Relays. SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

Easy, efficient and always up to date the SIRIUS modular system

SIMATIC ET 200SP and ET 200MP

SIMATIC S plus TIA Portal

Safety is a SIRIUS business

What fulfills the highest demands on the current and voltage quality?

Innovations in the Sirius Modular System for greater efficiency in Industrial Controls and in control cabinet construction


Industrial Controls. Command/signaling devices SIRIUS ACT with PROFINET IO. Introduction. Safety information. System description. Assembly.

Partner Product Valve island AirLINE SP Type 8647 for ET 200SP. unrestricted

L-force. Inverter Drives 8400 protec. On site and all systems go!

Master the elements in building automation siemens.com/sinamics-g120x

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

The compact and versatile converter with optimum functionality siemens.com/sinamics-g120c

The innovative interface for the last few meters to the process

Control Circuit Components

SSW06. Soft Starters.

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

Siemens tiastar TM Motor Control Center (MCC)

SINAMICS DCM Cabinet. DC drive converter cabinets for fast and simple system integration. siemens.com/sinamics. Answers for industry.

Experience Efficiency in a New Way.

Excerpt from the full range of SIRIUS ACT Push Buttons and Indicator Lights siemens.com/sirius-act

Siemens Safety Integrated Take a safe step into the future

Your choice for wall and panel mounted AC drives. Emotron FDU & VFX IP20/21 up to 132 kw

Engineered with TIA Portal. The powerful IO system for compact control cabinets SIMATIC ET 200SP. siemens.com/et200sp

The complete universe of Industrial Controls. You have it at your fingertips. sirius

Master the elements in water and wastewater applications siemens.com/sinamics-g120x

Solid-State Switching Devices

MICROMASTER 410/420/430/440 Inverters 0.12 kw to 250 kw Changes to the catalog DA /2006

Engineered with TIA Portal. Heat under control. SIPLUS HCS I/O systems for industrial heating applications. siemens.com/siplus-hcs

Siemens AG UG46 PLC. 1 Analog. 2 signal. 3UG48 monitoring relay

Digistart. Soft starters for 3 phase induction motors 7.5 to 800kW (18 to 1600A) 200V, 400V, 575V, 690V

SIRIUS Monitoring and Controlling. Overview of safety relays. Safety Integrated. Answers for industry.

Changeover SINAMICS CU240E to CU240E-2 (as from Firmware V4.4) SINAMICS G120. FAQ October Service & Support. Answers for industry.

Power Xpert C445 Competitive Comparison

SITRAIN. Introduction TIA Portal. Siemens AG All rights reserved. Unrestricted

High dynamics for demanding applications

Engineered with TIA Portal. Be flexible thanks to networking possibilities. Basic Controller SIMATIC S siemens.com/s7-1200

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

What is your drive? Simply get started? SINAMICS GM150: The uncomplicated medium-voltage AC drive. sinamics

Innovative features and solutions for SIVACON S8 siemens.com/sivacon-s8

AS-Interface, IO Link, Specialized Motor Starters

Jussi Rantanen, Component AC, December 29, 2009 ABB general machinery drives ACS355. ABB Group February 12, 2010 Slide 1

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

Lecture slides for Learn-/Training Document TIA Portal

Product type designation. Control elements. Installation type/mounting

For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.

Flexible and high performance. The SINAMICS S120 drive system. SINAMICS drives. Answers for industry.

ET 200S Motor Starters and Safety Motor Starters

Hannover Messe Welcome to the industry s global hotspot! Unrestricted Siemens AG 2018

Manual. Industrial Controls. Motor Management and Control Devices. SIMOCODE pro Fail-Safe Digital Modules. Edition 11/2017. siemens.

Power Management System. Measuring Devices for Power Distribution

Industrial Controls. Safety Integrated Application Manual. ASIsafe circuits for safety technology with AS-Interface safety monitor and DP/AS-i F-Link

SINAMICS DC Master (DCM) Base Drive

SENTRON 3VL Molded Case Circuit Breakers

Load Feeders and Motor Starters for Use in the Control Cabinet

Industrial Controls. Soft starters and solid-state switching devices 3RW51 Soft Starter. Description 1. Safety information 2

Product Information TBPN New Hybrid PROFINET/ PROFIsafe Block I/O Station

The VLT Micro Drive Small drive maximum strength and reliability

Combinable for All Applications

Unmanaged Industrial Ethernet Switches

Laboratory automation

Drives & Controls. IndraDrive Mi2 motor-integrated drive system. Open and flexible communication through integrated multi-ethernet interface

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

Uniform parameterisation, operation, and monitoring of intelligent switchboards

SIRIUS modular system

ST (6ES7132-6FD00-0BB1)

SIMATIC HMI Panels. Technical Data. siemens.com/hmi. Answers for industry. Engineered with TIA Portal

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

SIRIUS Motor Management and Control Devices

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

Switching, protecting, starting and monitoring with the highly flexible modular system usa.siemens.com/controls

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

Safe shutdown of SIRIUS 3RA6 compact starters with IO-Link interface. SIRIUS Industrial Controls, Safety Integrated, IO-Link FAQ 05.

Siemens AG AS-i Master for S Catalog IC 10 N December 2011 SIRIUS. Answers for industry.

AS-Interface. Safety Integrated Application Manual

One relay for safety and process continuity

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

MCD 200 MCD 500. Remove the Profibus Module using the following procedure: 1. Remove power from the module.

TIA Portal Workshop. Unrestricted. Siemens AG All rights reserved.

SIRIUS Modular System

MVK Metal Safety. Active Safety Technology. ÔMaximum Ô Safety. ÔÔRobust. ÔÔSealed

Simple - smaller - stronger SIMATIC ET 200SP. Unrestricted / Siemens AG All Rights Reserved.

MAKING MODERN LIVING POSSIBLE. VLT Micro Drive. Small drive maximum strength and reliability

SIRIUS modular system

SIEMENS AG For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.

VLT Micro Drive. Ready Set Go!

SICAM RTUs Ready for the Future

FUSION COMPACT. Load a. Line A. Inverse parallel scrs. Line B. Line c. inverse parallel scrs. Load C SCR POWER. O delta CONTROLLERS

Industrial Communication

SD250 VARIABLE SPEED DRIVE

Automation meets IT. SCALANCE X-500 central interface between Industrial Ethernet and IT networks SIMATIC NET. siemens.

SIMATIC ET 200SP. siemens.com/et200sp. Simple to use, smaller in size, stronger in performance. Answers for industry. Engineered with TIA Portal

SIMATIC ET 200SP Product information on documentation of the ET 200SP distributed I/O system Product Information

Transcription:

Partner conference 2018 The digital revolution www.siemens.be

SIRIUS 3RW5 Soft Starters As versatile as your application Unrestricted Siemens AG 2017 siemens.com/softstarter3rw5

SIRIUS 3RW5 Soft Starters As versatile as your application 3RW52 3RW55 Page 3

SIRIUS 3RW Soft Starters Portfolio at a glance Functionality Size 1 Size 2/3 Size 4 High performance 3RW55 ( 3) 3RW44 3-phase controlled General performance 3RW52 ( 3) Basic performance 3RW40 S0-S3 3RW40 S6-S12 2-phase controlled 3RW30 S00-S3 0 1,5 5,5 15 55 250 315 560 710 1200 Power [kw] at 400 V Page 4

The SIRIUS 3RW5 Soft Starters sets new standards in Digitalization in the Motor Starters market available HMI 2018 Digitalization Condition Monitoring SIMATIC Energy Suite Digital Twin (Efficient Engineering) + Full Portfolio From 5.5 kw up to 1200 kw 3 product lines: Basic, General and High Performance + Simulation Tool Application specific functions Auto parameterization Preventive Maintenance + TIA Integration Communication PROFINET, PROFIBUS,... + Efficiently Combined Tested combinations (SIRIUS Modular System) Certificates for worldwide use + Simple and efficient Engineering Page 5

SIRIUS 3RW Soft Starters matches the versatility of your individual challenges in fixed speed applications Pumping Ventilating Compressing Conveying Processing Water & waste water sewage Cooling pump Hydraulic press Air conditioning Cooling Compressor Tunnel ventilation Air compressor Cooling compressor Compressor in biogas plant Conveyor belt in cement factory Conveyor belt in quarry Reamer in biogas plant Stone crusher in quarry Agitator in chocloate factory Centrifuge in card board recycling plant Page 6

SIRIUS 3RW30/40 Soft Starters Basic performance Top highlights Feature / Function Benefit Voltage ramp and current limitation function τ Protection of electric and mechanic Hybrid-technology (integrated bypass contactor) τ Less heat dissipation and temperature rise in the control cabinet, energy saving Parameter assignment by only two parameters τ Fast and easy commisioning Compact design τ Space and cost saving Tested load feeder combinations possible with components from the SIRIUS modular system τ Easy selection and design of electric components for motor control Page 7

SIRIUS 3RW52 Soft Starters General performance Top highlights Feature / Function Benefit Hybrid technology and 3-phase motor control τ Minimal heat dissipation and symmetric/optimal motor control TIA-Integration communication module, operator panel optional τ Efficient engineering and highest flexibility in many automation fields Soft Torque τ Reduced mechanical stress and optimal pump stopping Parameterization via rotary knobs/potentiometers τ Fast and easy commissioning Wide range control and main voltage τ Less variants, high availability in weak power grids Page 8

SIRIUS 3RW55 Soft Starters High performance Top highlights Feature / Function Benefit Autoparameterization τ Easy and adaptive commissioning even in changing load profiles Hybrid technology and 3-phase motor control τ Minimal heat dissipation and symmetric/optimal motor control TIA-Integration communication module, operator panel optional τ Efficient engineering and highest flexibility in many automation fields Operator panel with colored display, local ethernet, micro-sd τ High flexibility in user-interface and intuitive menu structure Pump stopping and Soft Torque τ Reduced mechanical stress and optimal pump stopping Page 9

SIRIUS 3RW55 Soft Starters Autoparameterization Use-Cases Autoparameterization in 3RW55 A B The clueless commissioning engineer What needs to be done? How does it work? Set rated motor current I e Set points: ramp-up time + current limitation ramp-up time Ramp-up time as control value Continuous optimization of parameters with every single start (initially with default-parameter set) Changing load What needs to be kept in mind? Underdimensioning (Soft Starter and/or motor) and/or too high switching frequency causes tripping of motor overload or device self proteciton Previously: Commissioning difficult and time consuming Autoparameterization: Soft and smooth motor start guaranteed perfect for constant and slightly changing load characteristics Page 10

SIRIUS 3RW59 Accessories 52 55 52 55 52 55 52 55 Communication PROFINET-HF (switched Ethernet) PROFINET-Std, EtherNet/IP, Modbus-TCP PROFIBUS Modbus-RTU 52 55 52 55 HMI HMI High-Feature HMI Standard Page 11

Product data overview 3RW44 3RW52 3RW55 Rated current 29-1280 A 11-570 A 11-570 A Main voltage 200-480 V 400-600 V 400-690 V 200-480 V 200-600 V 200-480 V 200-690 V Bypass system Integrated (hybrid-technology) Number of controlled phases 3 Connection type Control voltage 115 V AC 230 V AC Standard, Inside Delta 24 V AC/DC 110-250 V AC Electronic motor overload protection CLASS 5, 10, 15, 20, 30 CLASS 10A, 10E, 20E CLASS 5, 10, 15, 20, 30 Thermal motor overload protection PTC, Klixon, Thermoclick PTC Typ A, Thermoclick (optional) PTC Typ A, Thermoclick Analog Output --- 0-10 V, 4-20 ma (optional) 0-10 V, 4-20 ma Protocol PB, PN-HF PN-Std, PB, MB-TCP, PN-HF, ETH-IP, MB-RTU Communication Operator panel/display PCB coating optional HMI Standard- and High-Feature-HMI High-Feature-HMI optional for cabinet door detachable/optional for cabinet door all PCBs Page 12

SIRIUS 3RW Soft Starters Size 4 Size 2/3 Size 1 3RW55 Depth < 200 mm Size 4 Size 2/3 Size 1 3RW52 Page 13

SIRIUS ACT with PROFINET short introduction Unrestricted Siemens AG 2017 siemens.com/sirius-act

SIRIUS ACT Performance in Action! Modern design + Extremely rugged + Easy to use + Flexible communication + Page 15

What is SIRIUS ACT with PROFINET?

SIRIUS ACT PROFINET Flexibility in all applications 1. PLC 2. Interface Module 3. Terminal Module 1. PLC 2. Failsafe Interface Module 3. Terminal Module System data Maximum expansion: 1 interface module + 20 terminal modules Cable length between modules: 1 meter Total cable length (IM TM): 10 meters Power supply: 24 V DC Page 17

SIRIUS ACT PROFINET Flexibility in all applications SIRIUS ACT PROFINET/PROFIsafe If there is a safety-related SIRIUS ACT device (e.g. EMERGENCY STOP up to SIL 3) in the application, it can be integrated easily via the fail-safe interface module (IM F). If safety-related, then connection to IM F. 1. PLC 2. Failsafe Interface Module 3. Terminal Module SIRIUS ACT application WITH safety SIRIUS ACT PROFINET All devices that are not safety-related can be integrated easily with the interface module (IM). 1. PLC 2. Interface Module 3. Terminal Module SIRIUS ACT application WITHOUT safety SIRIUS ACT PROFINET combined with standard cabling SIRIUS ACT standard contact modules + communication application A combination of terminal modules with standard modules is also possible. The standard contact modules must be snapped on first, always three of them; then the terminal modules. Page 18

SIRIUS ACT is part of integrated safety technology Integrated safety technology Features τ Customer benefits Detecting SIRIUS ACT AS-i AS-Interface SIRIUS ACT PROFINET F IM SIRIUS ACT can be integrated easily and quickly into the safety technology of an automation process via PROFINET/PROFIsafe. Reduces components and wiring Extended diagnostic capabilities Evaluating AS-Interface Reacting Page 19 PROFINET/PROFIsafe Distributed I/O with F modules SIRIUS motor starters Fail-safe controller SIRIUS contactors SIRIUS ACT enclosures and devices can be integrated easily and quickly into the safety technology of an automation process via ASIsafe. SIRIUS ACT is also integrated in the Safety Evaluation Tool. Link: www.siemens.com/safetyevaluation-tool Integrated in the TIA Portal Quick creation of reports and determination of the safety integrity level (SIL/PL) achieved via Safety Evaluation Tool

SIRIUS ACT PROFINET Just a few components for a complex panel Interface module Failsafe IM F Interface module IM Terminal module TM (command module) Terminal module TM (command and LED module) Terminal module TM (LED module) PROFINET/ PROFIsafe 4 DI (digital inputs) 1 DQ (digital output) 1 AI (analog input) 24 V power supply Spring-type connection: 3SU1400-1LL10-3BA1 Screw terminals: 3SU1400-1LL10-1BA1 PROFINET 24 V power supply Spring-type connection: 3SU1400-1LK10-3AA1 Screw terminals: 3SU1400-1LK10-1AA1 Max. 2 mechanical signals for mounting on all nonilluminated SIRIUS ACT devices Non-illuminated push buttons, selectors MLFB: 3SU1400-1MA10-1BA1 For mounting on all illuminated SIRIUS ACT devices, max. 2 mechanical signals Colors: red, green, yellow, white, amber, blue MLFB: 3SU1401-1MC 2 3 4 5 6 0 0-1CA1 For mounting on all SIRIUS ACT indicator lights Colors: red, green, yellow, white, amber, blue MLFB: 3SU1401-1ME 2 3 4 5 6 0 0-1DA1 Page 20

SIRIUS ACT PROFINET Accessories facilitate handling Memory module LEDs that can be integrated Cables Enables fast device replacement without engineering tools and product-specific engineering know-how Optional for IM; always available for IM F. Enhanced flexibility thanks to fast LED replacement on the interface module. 7-wire ribbon cable Grid: 1.27 mm Cross section: 0.081 mm² (per stranded wire) MLFB: 3RK3-9310-AA00 MLFB: 3SU1401-3BA 2 0-5AA0 3 4 5 6 0 Cable 5 m 3SU1900-0KQ80-0AA0 Cable 10 m 3SU1900-0KP80-0AA0 Page 21

Which customer benefits do SIRIUS ACT with PROFINET provide?

SIRIUS ACT PROFINET The clever way to connect Engineering Operator control & monitoring Ethernet Controller PROFINET Yesterday Standard Significantly reduced wiring Easy connection to HMI via PROFINET Quick and easy installation Reduces fault probability SIRIUS ACT PROFINET Today Panel HMI + SIRIUS ACT Panel HMI + SIRIUS ACT SIRIUS ACT with PROFINET Added value through reduced wiring Page 23

SIRIUS ACT PROFINET Fast and safe through PROFIsafe Engineering Operator control & monitoring Ethernet Controller PROFINET PROFINET / PROFIsafe SIRIUS ACT interface module EMERGENCY STOP does not need to be wired separately Safety and standard technology through one cable Reduced wiring SIRIUS ACT failsafe interface module Panel HMI + SIRIUS ACT Panel HMI + SIRIUS ACT SIRIUS ACT PROFINET Added value integrated safety technology Page 24

SIRIUS ACT PROFINET Create a digital twin Hardware configuration Features τ Customer benefits Engineering Ethernet Controller Structure of SIRIUS ACT Application in the TIA Portal SIRIUS ACT PN integrated into the TIA Portal Visual representation in the TIA Portal for better matching with hardware structure Simple and fast hardware configuration thanks to visual representatives No addressing of individual modules, physical addressing according to sequence Standardized data management Time saving thanks to intuitive hardware configuration PROFINET HMI - Touchscreen SIRIUS ACT PROFINET Hardware structure of the SIRIUS ACT application Page 25

Which advantages do you get with SIRIUS ACT PROFINET?

SIRIUS ACT PROFINET Diagnostics options without controller Hardware diagnostics Features τ Customer benefits How are faults found? LED test: all LEDs light up for 2 sec. when the supply voltage is applied Diagnostics via status LEDs Fast fault detection on the device Function test possible without controller and without controller know-how With or without controller No fault Function tests can be performed without controller System configuration possible without subject-specific knowhow Device defective! Wiring error SIRIUS ACT device has been operated Page 27

SIRIUS ACT PROFINET Device replacement without software and without stopping the system Device replacement Features τ Customer benefits How can modules be replaced in the field? Old interface module New interface module Remove EEPROM All data is stored on the EEPROM Insert EEPROM in a new device Devices can be replaced by persons who have no special knowledge Rapid device replacement No/brief system downtime EEPROM Page 28

SIRIUS ACT PROFINET A versatile system Integration into the TIA Portal + Integrated safety technology + Universal system for all SIRIUS ACT devices + Quick and easy installation + Reduced wiring + High flexibility based on additional interfaces (DI, DQ, AI) + Page 29

Thank you for your attention Wim Janssens Sales Specialist RC-BE DF CP / SIRIUS Soft Starter 3RW Guido Gezellestraat 123 1654 Beersel Mobile: +32 499 69 35 61 E-mail: wim.janssens@siemens.com Subject to changes and errors. The information given in this document only contains general descriptions and/or performance features which may not always specifically reflect those described, or which may undergo modification in the course of further development of the products. The requested performance features are binding only when they are expressly agreed upon in the concluded contract. All product designations, product names, etc. may contain trademarks or other rights of Siemens AG, its affiliated companies or third parties. Their unauthorized use may infringe the rights of the respective owner. siemens.com Page 30