Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Similar documents
Safety instructions Overvoltage protection B81-35

Safety instructions VEGATOR 121, 122

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information

Cerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus

Safety Instructions Cerabar M PMC51, PMP51, PMP55

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

5 Fieldbus Technology

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure

Operating Instructions

Interface and Supply module. IPC 3x0i / PSC 3x0i

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

MANUAL Surge Protectors

Supplementary instructions. VEGADIS adapter. For connection of an external display and adjustment unit or a slave sensor. Document ID: 45250

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Supplementary instructions. Plug connector ISO for level sensors. Document ID: 30380

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

Supplementary instructions. Plug connector ISO for continuously measuring sensors. Document ID: 30375

Refer to attachment for more details. Andreas Meyer

Supplementary instructions. Plug connector Harting HAN 8D. for continuously measuring sensors. Document ID: 30376

SMARTLINE RM76 Supplementary instructions

DR7100 SERIES Supplementary instructions

Signal conditioning instruments VEGASCAN 693. Product Information

Safety Instructions Omnigrad TRxx, TCxx, TxCxxx

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

Operating Instructions

PHOENIX CONTACT - 12/2007

PI-EX-ME-2NAM/COC-120VAC

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

PI-EX-ME-2NAM/COC-24VDC

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Product information Ultrasonic

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Installation & Operation Manual

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

MACX MCR-EX-SD LP(-SP)

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel.

BA488CF-P PROFIBUS PA Intrinsically safe Panel mounting Fieldbus Display issue 3

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

How to calculate an Intrinsically Safe loop approval.

Tutorial: Characteristics & Requirements of Physical Networks in the Process Industry

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Data sheet. Constant current DALI LED control gear 80 W Output power ma Output current Intelligent temperature protection.

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

IECEx Certificate of Conformity

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Safety Instructions Cerabar S PMP71, PMP75

PHOENIX CONTACT - 02/2008

Digital Positioner 8049

Technical Data. Dimensions

Grounding Monitoring Device Series 8485

Technical Information Promonitor NRF560

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

Isolating repeater IRU 420

Intrinsically safe batch controller Batching Master 110i

IECEx Certificate of Conformity

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

Flow Measurement SITRANS F C

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

General Specifications

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

Product information. Hydrostatic. Submersible pressure transmitter VEGABAR 86 VEGABAR 87 VEGAWELL 52. Document ID: 45079

PHOENIX CONTACT - 05/2007

PROFIBUS-PA Positioner Type 3785

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

PHOENIX CONTACT - 01/2008

1/10 SBEx-4S BINARY SEPARATOR with examples of applications 1 OR 2 CHANNELS IN RAIL HOUSING (TS35, width 22,5mm)

Operating manual ELX channel digital input terminal for NAMUR sensors, Ex i. Version: Date:

English. Operating Manual. Universal Isolating Amplifier TV125M / ST125M. Save for later reference. Companies / Brands of GHM

Reed sensor For bypass level indicators Model BLR

Operating Manual Touchpad CHALLENGER TPi

M E M O R A N D U M I.S.

Installation & Operation Manual

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

IECEx Certificate of Conformity

Trendmaster* Galvanic Isolator

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

Zener Barriers Bulletin 937Z

Operating Instructions. VEGA DataViewer. Software for archive, administration and display of DTM data. Document ID: 51547

Product information. Radar. Level measurement in bulk solids VEGAPULS 67 VEGAPULS SR 68 VEGAPULS 68 VEGAPULS 69. Document ID: 29427

Safety Instructions Micropilot FMR50/51/52/53/54/56/57

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

VEGAMET 381 VEGAMET 624 VEGAMET 625

INTRINSICALLY SAFE ACOUSTIC EMISSION TRANSDUCERS

BA448CF-F FOUNDATION fieldbus Intrinsically safe Panel mounting 8 variable Fieldbus Indicator Issue 3

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Explosive atmospheres occur when flammable gases, mist, vapors or dust are mixed with air. This creates a risk of explosion.

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Grounding Monitoring Device Series 8485

Operating manual ELX3152. Two channel, analog input terminal, 0/4 20 ma, single ended, 16 Bit, Ex i. Version: Date: 1.5.

Transcription:

Safety instructions ÜSB62-36G.C_* and ÜSB62-30W.C_* IECEx TUN 07.0002 Ex [ia Ga] IIC T6 Gb Ex ia IIC T6 Gb 0044 39878

Content 1 Area of applicability 3 2 General 3 3 Electrical data 3 3.1 Application conditions 4 4 Protection 4 5 Installation 4 6 Grounding 4 7 Insulation voltage to earth 5 Please note: These safety instructions are part of the operating instructions: l 12274 - overvoltage arrester l 39879 - certificate IECEx TUN 07.0002 2 ÜSB62-36G.C_* and ÜSB62-30W.C_*

1 Area of applicability These safety instructions apply to the overvoltage arresters B62-36G, B62-30W of type series ÜSB62-36G.C_*, ÜSB62-30W.C_* according to the IECEx certificate IECEx TUN 07.0002 issue No. 1 (certification number on the type label) and for all instruments with the number of the safety instruction (39878) on the type label. 2 General The overvoltage arresters B62-36G, B62-30W of type series ÜSB62-36G.C_*, ÜSB62-30W.C_* are used for overvoltage protection of intrinsically safe EPL-Ga circuits, circuits in protection class ia or for overvoltage protection of intrinsically safe circuits in protection class ia/ib. The overvoltage arresters B62-36G, B62-30W for intrinsically safe circuits in protection classification ia meet the requirements for overvoltage arresters according to IEC 60079-14, sect. 12.3, as suitable protection against the danger of ignition caused by lightning. The overvoltage arresters B62-36G, B62-30W are intrinsically safe electrical devices for installation in hazardous areas with combustible gases, mist or vapours or for installation outside of hazardous areas. The overvoltage arresters B62-36G, B62-30W are intrinsically safe electrical devices for installation in hazardous areas of EPL-Gb of all combustible materials of explosion group IIA, IIB and IIC. The overvoltage arrester B62-36G is suitable to protect signal circuits of two-wire-loop powered sensors. The overvoltage arrester B62-30W is suitable for protection of electrical BUS signals according to the Fieldbus system Profibus PA or Foundation Fieldbus. If the overvoltage arresters B62-36G, B62-30W are used for protection of intrinsically safe signal circuits, the general Ex mounting instructions for explosion protection IEC 60079-14 as well as these safey instructions and the operating instructions must be observed. The installation of explosion-endangered systems must always be carried out by qualified personnel. 3 Electrical data The protection class of the overvoltage arresters B62-36G, B62-30W corresponds to the respective protection class of the connected intrinsically safe signal circuit. When connecting an intrinsically safe EPL-Ga signal circuit with protection class ia, the protection class of the signal circuit also corresponds to the protection class ia as EPL-Ga signal circuit. When connecting an intrinsically safe signal circuit with protection class ia or ib, the protection class of the signal circuit also corresponds to protection class ia or ib. Overvoltage arrester B62-36G Signal circuit: (Input terminals E1, E2, output terminals A1, A2) In ignition protection type intrinsic safety Ex ia IIC/IIB or Ex ib IIC/IIB For connection to an intrinsically safe circuit. Maximum values: Ui = 36 V Ii = 450 ma Ci = 2,5 nf Li = 0.15 mh ÜSB62-36G.C_* and ÜSB62-30W.C_* 3

Overvoltage arrester B62-30W Signal circuit: (Input terminals E1, E2, output terminals A1, A2) In ignition protection type intrinsic safety Ex ia IIC/IIB or Ex ib IIC/IIB For connection to an intrinsically safe circuit. Maximum values: Ui = 36 V Ii = 400 ma Ci = 2,5 nf Li = negligibly small The insulation voltage of the intrinsically safe signal circuit to parts which can be grounded, is >500 V AC. Thus, the intrinsically safe signal circuit is classified as ungrounded. 3.1 Application conditions Permissible ambient temperatures in dependence of temperature class Overvoltage arrester B62-36G Temperature class T6 T5, T4, T3, T2, T1 Permissible ambient temperature -40 +60 C -40 +80 C Overvoltage arrester B62-30W Temperature class T6 T5, T4, T3, T2, T1 Permissible ambient temperature -40 +53 C -40 +80 C 4 Protection Protection class: IP 30 If the overvoltage arresters B62-36G, B62-30W are mounted in the metal or plastic housing, at least protection class IP 54 according to EN 60529 is met. 5 Installation The overvoltage arresters B62-36G, B62-30W are suitable for mounting in hazardous areas of EPL- Gb or for mounting outside of hazardous areas. Please make sure that the overvoltage arresters B62-36G, B62-30W are only installed in areas allowing protection class IP 30 or mounted in a housing with protection class IP 54. 6 Grounding The potential equalisation of the overvoltage arresters B62-36G, B62-30W must be connected with the potential equalisation in the Ex area. 4 ÜSB62-36G.C_* and ÜSB62-30W.C_*

7 Insulation voltage to earth The intrinsically safe circuits of the overvoltage arresters B62-36G, B62-30W are galvanically isolated from the potential equalisation with 500 V AC. ÜSB62-36G.C_* and ÜSB62-30W.C_* 5

6 ÜSB62-36G.C_* and ÜSB62-30W.C_*

ÜSB62-36G.C_* and ÜSB62-30W.C_* 7

VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info.de@vega.com www.vega.com ISO 9001 VEGA Grieshaber KG, Schiltach/Germany 2012 Subject to change without prior notice