FES BMS CONTROL MANUAL

Similar documents
FES BMS CONTROL MANUAL

FES LCD Display Version 1.1

FES SYSTEM MANUAL. Version 1.22

FLAP indicator. Installation manual Version 1.10

PDA-CAN Bridge. Version 1.0. LXNAV d.o.o. Kidričeva 24, 3000 Celje, Slovenia tel fax

LXNAV RS485 to RS232 Bridge

Flarm LED indicator. Version 1.1

PowerMouse Version 1.05 March PowerMouse. The FlarmMouse successor. Version 1.05

V8/V80. Installation manual. Version 5.0

PowerMouse Version 1.00 November PowerMouse. The FlarmMouse successor. Version 1.00

The Smallest flarm with integrated GPS antenna. Version 1.01

NANO. Flight recorder (including NanoConfig configuration program) Version 1.0

Craggy Aero Ultimate Le 5.7

ASCL1 / ASCL2 CarLink Guide for Android Users

Woolich Racing. USB ECU Interface User Guide

ASCL1 / ASCL2. CarLink Guide for BlackBerry Users Audiovox Electronics Corporation. All rights reserved.

USB-A to Serial Cable

FlarmView and FlarmView57

Bluetooth 4.0 USB Adapter Model

USB Server User Manual

CellSync Manager. User Manual F8V7D006-SS F8V7D008-SS. Get online and synchronize anywhere. Web Access. Phone Book Manager

Trimble R/5000 Series GPS Receivers Release Notes

Instruction Manual. CT-4 High-Current Transformer

XS/SC26-2 Safety Controller Quick Start Guide

PCMCIA Flash Card User Guide

Doran 360SL Programming Tool

XS/SC26-2 Safety Controller. Quick Start Guide

MANUFACTURING LLC Please read this manual carefully before using this product. 360SLT SMARTLINK TM TPMS TABLET USER MANUAL

Trimble S6 and SPS700 Total Station Firmware

FastForward TM User Guide

FastForward User Guide

Made in U.S.A. 1

1. Introduction... 1 Features... 1 Package Contents... 1 System Requirements... 1 LED Status... 2

TiR2, TiR3, TiR4. Getting Started Guide. IR FlexCam Thermal Imager

PRODUCT CONTENTS... 3 II. REQUIRED MATERIALS... 3 III. OVERVIEW... 3 IV. BENCH LAYOUT...

What s in the box. SUP paddle sensor. Paddle sensor mounting track. Charger. USB cable. In your Motionize SUP kit you will find:

Mini Document & Photo Scanner. i-convert

SENtral Demo Module Quick Guide

DX-C USER GUIDE

TR100-A / TR200-A. Temperature / Humidity Data Loggers. Users Manual. For detailed specifications and ordering info go to

TranSync Compliance Monitoring User Manual

VM-1 USB Vehicle Communicator Installation Guide

SecureMag Encrypted MagStripe Reader

LiBRA Control System USER MANUAL

SC-01 Data Logger Management Program Operator s Manual

Illuminate 25 Light Starter Kit What s included Light String Control Box Spare Fuses Safety Instructions Quick Start Guide

SMART SWITCH. User s Manual. This product is to be used with the MySmartBlinds automation kit.

CA-A480-A Elevator Controller. Reference & Installation Manual

OBDII Programmer Quick Start Guide

Tattletale Micro Tracker

TB-24P/24R/16P8R. Relay Outputs or Isolated Inputs Terminal Board Series

Instructions. RM3000 Rackmount Kit for TDS3000 Series Oscilloscopes

WARRANTY & LIMITATION OF LIABILITY

CMR Quick Start Guide. CMR-8500 DVB IP Encapsulator. Part Number MN-CMR68500-QSG REV. 1

IMPORTANT PLEASE READ FIRST

XS, XST. IR InSight Thermal Imager. Getting Started Guide

Bad Elf Wombat User Manual

WARRANTY & LIMITATION OF LIABILITY

TiR2,TiR3,TiR4, Ti40,Ti45,Ti50,Ti55 IR FlexCam Thermal Imager

Instruction Manual. HH610-SW Application Software for Portable & Bench Meters

File Transfer Tool Guide Version 1.0. Revision History. Revision Date Page(s) Changed Description of Change 4/2009 All pages First edition released.

Micro Bluetooth 2.1 EDR Adapter

MPE5 Scouting Camera Instruction Manual.

Automatic Phone-Out Home Monitoring System

UPS25 API Manual for Windows 2000/XP/Vista

Micro Bluetooth 2.1 EDR Adapter

SUPPLEMENT TO THE MDC-360C MANUAL MDC-361C. Film Deposition Controller. IPN Rev. C

PWRcheck Spring City Drive Waukesha, WI

zpen-1080p Features zpen-1080p Layout

TD 600 Thermo-Fastprinter

zclock-200w User Manual

User Manual TLS HDMI Switch Splitter 3/2

The HPV Explorer is a serial communication program used to work with the HPV 600/900 s parameters via a computer s serial port

Chore-Tronics Mobile Server

Digital Camera USER GUIDE

GX-2009 Data Logger Management Program Operator s Manual

Piccola Smart Box Member of Modul MAS family

HDR-8X8-Plus. User Manual. HDMI 4K 8x8 Switch Matrix Connect up to eight different HDMI video sources to eight different outputs.

Operating Bulletin MODBUS-RTU. The Fastest Flow Controller Company in the World!

USER S MANUAL ENTITY. Energy Meter TRINITY. Entity Operational Manual

FlarmView and FlarmView57

GPS140 Windows Application User s Manual Version 2.0.x

1.3 MegaPixel Auto Focus Webcam USER MANUAL

03 Series Data Logger Management Program Operator s Manual

Portable. GL100 An eye on your mobile property. User Guide

SOFTWARE VERSION 3.3. CD P/N Rev. C

Operations Manual EcoSense ph100

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

DataPort 250 USB 2.0 Enclosure User s Guide (800)

THECHARGEHUB.COM. User Manual. For Square & Round Models

F²MC-8L FAMILY MB89201 SERIES FLASH PROGRAMMING 8-BIT MICROCONTROLLER APPLICATION NOTE. Fujitsu Microelectronics Europe Application Note

ACLD Channel Opto-isolated Digital Input Board

SLUG DATA-LOGGER MANUAL. YieldPoint Inc. JULY 2009

Bluetooth USB Adapter TALUS. User Guide

MWR30. INSTALLATION/OWNER S MANUAL Wired Remote Control MARINE

Firmware Update Function

High Speed Shutter. Owner s Manual. Revision 1.0. Copyright 2012 Cognisys, Inc.

NAPCO iseevideo Fixed IP Camera User Guide

HD-1X4-4K User Manual

General Notice Introduction Functional Description Product Troubleshooting Driver Setup...

Transcription:

FES BMS CONTROL MANUAL Version 1.26 for BMS control software version 1.31 Suitable for: -FES BATTERY PACK GEN1 (with external BMS-7R) -FES BATTERY PACK GEN2 (with internal BMS-9R) LZ design d.o.o., Brod 3D, 1370 Logatec, Slovenia tel +386 59 948 898 info@lzdesign.si www.front-electric-sustainer.com

Table of content: 1. Important notices...3 1.1 Limited Warranty...3 2. Installing the BMS Control Software...4 3. Communication cable...6 4. Setting communication with BMS...8 5. Basic system parameters overview...12 5.1 Data logging...14 5.2 BMS settings setup...14 6. Revision history...15 Page 2 of 15

1. Important notices Please read this manual thoroughly. It contains important information about your system, having a vital importance to the flight safety. Information in this document is subject to change without notice. LZ design reserves the right to change or improve their products and to make changes in the content of this material without obligation to notify any person or organization of such changes or improvements. A Yellow triangle is shown for parts of the manual which should be read carefully and are important for proper operation. Notes with a red triangle describe procedures that are critical and may result in reduced safety or may lead to critical situation. 1.1 Limited Warranty A bulb icon is shown when a useful hint is provided to the reader. This LZ design FCU product is warranted to be free from defects in materials or workmanship for two years from the date of purchase. Within this period, LZ design will, at its sole option, repair or replace any components that fail in normal use. Such repairs or replacement will be made at no charge to the customer for parts and labor the customer shall be responsible for any transportation cost. This warranty does not cover failures due to abuse, misuse, accident, or unauthorized alterations or repairs. THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED OR STATUTORY, INCLUDING ANY LIABILITY ARISING UNDER ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, STATUTORY OR OTHERWISE. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, WHICH MAY VARY FROM STATE TO STATE. IN NO EVENT SHALL LZ DESIGN BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM THE USE, MISUSE, OR INABILITY TO USE THIS PRODUCT OR FROM DEFECTS IN THE PRODUCT. Some states do not allow the exclusion of incidental or consequential damages, so the above limitations may not apply to you. LZ design retains the exclusive right to repair or replace the unit or software, or to offer a full refund of the purchase price, at its sole discretion. SUCH REMEDY SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY FOR ANY BREACH OF WARRANTY. To obtain warranty service, contact your local LZ design dealer or contact LZ design directly. February 2013 2013 LZ design. All rights reserved Page 3 of 15

2. Installing the BMS Control Software FES BMS Control setup file is available for download at our dedicated FES website, in download section, under software. http://www.front-electric-sustainer.com/download.php After download is completed, run the Setup.exe application in the BMS Control Setup folder. Click Next at the Welcome to the BMS Control Installation Wizard. Choose the Destination folder where the application will be installed. Confirm the installation information by clicking Next button or reenter the installation information by clicking Back button. Page 4 of 15

You have now successfully installed the software. Click the Finish button to exit the installation. Page 5 of 15

3. Communication cable BMS-PC communication cable (suitable for external BMS, GEN1 battery packs) BMS-Charger-PC communication cable (suitable for GEN2 battery packs) Page 6 of 15

When the BMS-PC cable is inserted in the USB port of PC for the first time, drivers needs to be installed. The Found New Hardware Wizard pop-up window appears. Choose Install the software automatically option and click Next. To complete the Found New Hardware Wizard click the Finish button. Page 7 of 15

The BMS-PC cable behaves as virtual com port (VCP). A number is assigned to the VCP in the Control panel/system/device Manager under Ports (COM & LPT). This port number is used to set the communication parameters in the Set communication properties window of the BMS Control software. If drivers were not installed automatically you can find them also on the FTDI web site http://www.ftdichip.com/drivers/vcp.htm In case of troubles contact LZ design. 4. Setting communication with BMS You can now run the BMS Control software. If this is the first time you have been running the program, the Serial ports has not been set yet and the Error occurs. You must follow the procedure described below. Click the Continue button. Page 8 of 15

The BMS is not connected to the BMS Control software, the sign is turned on and Reading BMS configuration window pops out. Click the Cancel button and open Set communication properties in the Program menu. Select the proper COM port number that was assigned to and also check that other parameters are set as they are listed below. RS-232 Bitrate: 56000 MAIN Address: 6 CTL Address: 0 Timeout: 350 ms Page 9 of 15

In some cases there is visible tick only and so you are not able to choose a COM port. This usually happen if you have on your PC installed Windows Vista or Windows home premium edition operating system. In such case it is required to install additional Visa USB & COM drivers, as some operating systems do not have them included already. You can download installation file for a Visa USB & COM from this link: https://www.dropbox.com/s/j5uarkxjk2oxriy/visa462full.exe?dl=0 Open Visa426Full.zip file and wait until it extracts to a temporary location on your computer. Continue the installation by selecting Next. Page 10 of 15

Select the location for National Instruments VISA Drivers. For the RS485 Cable to work, only Serial, USB and COM Support Drivers under Run Time Support should be chosen. When VISA drivers are successfully installed, restart the computer. If your computer has installed Windows 7 Starter, you should follow procedure, as described on this link: http://digital.ni.com/public.nsf/allkb/1817f501d7ba67f28625768f0000b260 Page 11 of 15

5. Basic system parameters overview When BMS and your PC are connected, the program presents all system parameters in the original Settings window. You can read all the pre-set parameters, about Balancing, Charging, Temperature, Cell voltage and about Battery pack data. Balance voltage END Balance voltage START Balancing Voltage level to which each individual cell will be balanced (default value is 4,16V). Average battery pack voltage above which the BMS performs the balancing while charging (default value is 4,1V). Charging END of Charging End of charge voltage of the individual cell (default value is 4,16V). Hysteresis Charging hysteresis of individual cell (default value is 0,1V). Temperature MAX Tbat MIN Tcharge MAX Tbms MAX Vcell The MAX Vcell Hysteresis MIN Vcell MIN Vcell Hysteresis If temperatures of battery pack reach this value, charging will be stopped (default value is 55 C). If temperature of battery packs is bellow this value, charging is not allowed to start (default value is -1 C). Maximum allowable temperature of the BMS due to the balancing. If BMS reach this temperature, balancing and charging will stopped. Balancing and charging will start again, when BMS temperature drop 10 C below the set value (default value is 50 C). Cell voltage The highest allowed voltage of the individual cell. Above this voltage alarm turns on (default value is 4,18V). (default value is 0,015V). The lowest allowed voltage of the individual cell under which the alarm turns on (default value is 3,1). (default value is 0,05V). Battery pack data Chemistry (default setting is Li-po Kokam High power) Capacity (default value is 40Ah) Cycle Counting of charging cycles Paralel strings (default value is 0) Page 12 of 15

To see the single cell voltage, switch the view from Settings to Logging. On this second Logging screen you can see accurate Cell voltage of each 14 cells, so this is the most used screen during monitoring charging process! After a few minutes of charging it will also start calculating Cell internal resistance of each cell. Internal resistance is possible to calculate only during charging. BMS which is inside of battery pack, gives instructions, to the charger how to charge, by PWM signal through BMS-Charger signal cable. This means when to start, when to stop, and charging current value (from 0...9A, with 600W charger). After initial start, charging current ramps from 0 to 9A slowly. When it reaches 9A, then BMS gives instructions to suddenly reduce charging current to 0A, but just for a short time. When this happens, BMS measure, voltage drop on each cells, and calculates internal resistance. This usually happened the first time in about 3-5 minutes from start of charging. Accuracy of calculation is just approximate (but good enough for relative comparison of cells resistance), as there is not accurately measured charging current, but BMS knows how high it should be as BMS instruct charger about. If charger is not connected, BMS do not know that, so still calculates, but as there is no voltage drop the result is close to zero mohm after some time... Right side of screen shows, pack voltage, minimum and maximum voltage of cells, approximate charging current (based on data which is BMS is sending to charger), SOC as state of charge, SOH as state of cells health. Temperature of pack is not visible if sensor is not connected. Third screen Flash History is not important for FES users! Page 13 of 15

5.1 Data logging If you might have some problems during charging is it suitable to record charging process data in a *.txt file, which you can send it later by email to FES manufacturer. Such file is very helpful for troubleshooting the problem. Choose the File path and set suitable Time interval you want BMS to report. In most cases is OK if you set time interval to 2 seconds. If the Time interval is set to 00:00:00 the software logs the data with its maximum achievable speed By pressing the Start button you start the logging, to stop recording, just press the button Stop. The data is recorded in *.txt file you chose as follows: date time Pack voltage [V] Curren t [A] Cell 1 [V] Cell 2 [V] Cell n [V] T BAT [ C] T BMS [ C] 5.2 BMS settings setup It is possible to change some BMS parameters in Settings window. This is possible only if BMS is in unlocked state. To unlock BMS you need to enter proper password, which you will get from FES manufacturer if necessary. Page 14 of 15

6. Revision history February 2011 Initial release of manual February 2013 Updated to Version 1.11 March 2013 Updated to Version 1.12 December 2013 Updated info about Visa drivers, Version 1.2 July 2014 Minor updates to Version 1.21 December 2014 Added info about calculation of cell internal resistance 1.22 May 2015 Added info about installation of Visa drivers November 2015 Added info about installation of Visa drivers to Win 7 Starter March 2016 Corrected broken link to Visa drivers, window with a thick February 2017 Added info about default settings, Version 1.26 Page 15 of 15