Note: the wiring of the dead-man buttons has been changed since October 2001.

Similar documents
epalm10 Product Manual

UniOP epad03 and epad04

UniOP epad30, epad32. Tech-note PN# tn171-3.doc - 03/10/ Ver Highlights

Compact HMI devices with 9 function keys, numerical keypad and 20 characters display.

UniOP CP01R-04, CP05R-04 and CP01F-02

Compact HMI devices with 5 function keys, numerical keypad and 20 characters display.

DomiOP ebis504. Tech-note. Highlights

Newsletter. Communicate and Stay in Control. In This Issue

UniOP. Universal Operator Panels. Installation Guide

DATA SHEET Advanced Graphical Interface, AGI 100 series

Hardware and Engineering. MI4 Display and Operator Panels 05/01 AWB-C GB

DATA SHEET Advanced Graphical Interface, AGI 300 series

F1000 User's Manual. (Version: V1.01)

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories

Machine TV Interface. mtv-100. Memory Processor. I/O Port RTC. Power. Specification. Certificate Software

Touch Displays, Line COP 400

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

USB Enclosure Series

PWS3260 Installation Guide

Vision OPLC. Technical Specifications. V T34 Technical Specifications

User Manual. cmt-svr Startup Guide

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

IT and Instrumentation for industry. Features. Introduction. Applications

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

1. CP430, CP470, CP474, CP770 and CP774

VARAN Splitter Module VSV 041

XC-CPU-201 XC-CPU-201-XV

Product Datasheet. Touch screen Part number OPERATOR INTERFACE

Ø 58 mm, depth 48 mm Shaft dimension. Hollow Ø 15 mm, solid Ø 6 or 10 mm Shaft loading (axial and radial)

5/2 HMI Brilliant Displays of Processing Sequences

Connecting a Cisco Reader Module

UC-2000 Installation Manual Unicorn Computers Technology Limited

User Manual. cmt-svr Startup Guide

TPC1. User s Manual. DYNASERVO INC.

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

TCNM-ACBB1 Installation Manual

MobileView Junction Box

Fics-RT1. User s Manual

Vision570 TM /560 TM. Color OPLC TM. Color Vision570 TM /560 TM Series Featuring:

Power Panel. Terminal block, 12 pin, 20 pcs., cage clamps. Table 5: Order data for PP41

Connecting UniOP to Simatic S7 MPI

MHAD 50 - HDmag. Features

CERTUS Configurable Safety Module

Safety Monitoring Relays

CP150B Vandal & Weather Resistant Keypad Security Systems

Extruder Controls ExtruVision S

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

Tough Panel Plus 15"

1.5 axis motion controller

DATA SHEET Advanced Graphical Interface, AGI 100 series

Operator dialogue terminals 1

CM-110SK Standalone Keypad Installation Instructions

FEATURES FEATURES. Macro Function Usage Supports strong Visual Basic script language which includes more than 500 built-in functions.

dyne Motion Control Hydraulic Pneumatic Electrical Mechanical (80 ex700 Series The Revolutionary IIoT Controller

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

Component identification

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

MT-8000 series. MT-8056T/ MT-6056T Installation Instruction. 1.0 Installation and Startup Guide. 2.0 Installation Instructions

IF-80x Outdoor Terminal

Certus Configurable Safety Module

WTX120. Legal-for-trade industrial weighing terminal. Special features. Data sheet

PWS1711/1760 Installation Guide

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

1210 TM /1040 TM. Features: V1210 Flat Panel. V1040 Classic Panel HMI PLC. Communication

HT101. User terminal. Function

PK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp.

MLC 380 R2. For Mechanical Engines. Installation Manual

EL-ST100 KEYPAD CONTROLLER

HMI HUMAN MACHINE INTERFACE

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm

EX-RC1 Remote I/O Adapter

SIPLUS S7-200 TD 400 C

XBTGT2120 advanced touchscreen panel x 240 pixels QVGA - 5.7" - 24 V

E X T E R I n t e lli g e n t d e s i g n

Quick Start Installation Guide

XBTGT2120 advanced touchscreen panel x 240 pixels QVGA - 5.7" - 24 V

EX-RC1 Remote I/O Adapter

V350-T38 V350J-T38.

dialogue terminals 1 Description 1 Magelis touch-sensitive graphic terminals New Technology, XBT GT with 7.5 screen Description

Installation and Operating Instructions. webremote

FEATURES DESCRIPTION GENERAL SPECIFICATIONS

EX-RC1 Remote I/O Adapter

2 Device description. 2 Device description 2.1 Function. 2.1 Function. 2.2 Intended use. 2.3 Device versions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

IAI Corporation 1998, 1999, For Reference Only.

PXR11 PXR12. System controllers DESIGO PX

EZ Touch Plus. Copyright 2014 by AVG Automation. All Rights Reserved.

Connecting a Cisco Input Module

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

IST ULTRASTAB Power Supply for high precision transducers

1/2 Description XV400 Flexible in Application

Fics-TPC1 Motion Controller. User Manual. Dynaservo Inc.

Control Panel CP600-eCo CP604, CP604-B

Single Door Standalone Access Control User Manual

TM221CE40T controller M IO transistor PNP Ethernet

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

PWS500S Installation Guide

Transcription:

UniOP epalm10 The epalm10 is a state-of-the-art handheld HMI device with a graphic display and a keypad. The rugged polyamide enclosure offers a high level of shock and environmental resistance making the epalm the ideal choice for use in the factory floor. Note: the wiring of the dead-man buttons has been changed since October 2001. Highlights Graphical display 120x64 pixels (up to 8 lines 20 characters) Highly visible transflective LCD display 27-keys keypad with tactile feedback Connection to industrial bus systems Large memory size (512 KB Flash) IP65 protection Programmable with UniOP Designer version 5.08 Includes Emergency Stop button Includes dead-man buttons The epalm HMI panels are the handheld products of the UniOP family. All of the epalm products support the rich common functionality of the UniOP operator panels: Transflective LCD display ensures readability under the most critical light conditions Powerful and intuitive programming with the UniOP Designer software Support of more than 130 communication drivers for industrial devices Optional modules for fieldbus systems (Profibus DP, DeviceNet, CANopen, ) Display data in numerical, text and bargraph format Dynamic graphic objects Recipe data storage Keyboard macro editor Alarms and historical alarm list Eight levels password protection Report printing to serial printer In addition some unique features make them a perfect fit for handheld operation. Emergency Stop button. Hardwired Dead man buttons. Hardwired High-quality polyurethane cable for mobile applications Page 1

Technical data epalm10 Display Graphic resolution 120x64 pixels Active display area 66 x 33 mm Rows/columns 8x20 Character height - Scalable fonts Yes User definable characters 256 Contrast regulation Software Brightness regulation No Memory User memory 512 KB Flash User memory expansion - Front panel Function keys 9 System keys 18 Touch screen No User LED s 20 System LED s 5 Connections PC/Printer port PLC port Aux port (fieldbus connection) External keyboard port Programming speed Yes RS-232, RS-485, RS-422 Yes, with optional modules No 9600 38400 bps Functionality Page size 32 rows Number of variables per page Unlimited Recipe memory 16 KB UniNet network Client/Server Alarms 1024 Event list 256 Alarm info page Yes Password Yes Battery Yes. User replaceable lithium battery model Duracell DL2430 Hardware RTC Yes Screen saver No Buzzer No Power supply voltage 18-30 VDC Max power consumption ~ 300 ma at 24 VDC Fuse Automatic Weight ~ 0.5 Kg (not including cable) Operating temperature 0 to 50 C Storage temperature -20 to +70 C Page 2

Operating and storage humidity Protection class Min diameter of cable Max diameter of cable 5 95 % RH non-condensing IP65 7 mm 11 mm The product is designed for installation in an industrial environment in compliance with the regulations: Emitted interference EN 61000-6-4, 2001 Noise immunity EN 61000-6-2, 2001 All circuits in the handheld, including the wiring for the emergency stop button and the deadman buttons, must be considered SELV circuits. They will have to be used in compliace with EN 60950. Dimensions A 116 mm 4.56 B 86 mm 3.38 C 102 mm 4.01 D 239 mm 9.41 A D C B Page 3

Connections The unit provides all standard UniOP connections (PC/Printer Port, PLC Port, Aux Port, power) plus some special signals (Emergency Stop button two NC contacts, dead-man buttons two independent NO contacts) on the internal terminal block. Note: the epalm10 unit does not include a current loop (20 ma) interface on the PLC port. The communication modules TCM04 (Interbus), TCM07 (Simatic S7 MPI without optical insulation) and TCM10 (Ethernet) are not supported. The internal terminal block is a detachable module with five terminal blocks. The position of the connectors and the numbering of the contacts are shown in the figure below. The board shown in figure will be referred as CA01 interface board. CN2 CN1 CN3 CN5 CN4 The assignment of the signals on the connectors is shown in the tables below. Terminals indicated as Reserved should not be used. CN1 Aux Port CN2 PC/Printer Port 1 Aux Port pin 5 1 Reserved 2 Aux Port pin 9 2 Reserved 3 Aux Port pin 4 3 Reserved 4 Aux Port pin 8 4 Reserved 5 Aux Port pin 3 5 +5V output (max 100 ma) 6 Aux Port pin 7 6 GND 7 Aux Port pin 2 7 RXD 8 Aux Port pin 6 8 CTS 9 Aux Port pin 1 9 TXD 10 Reserved 10 RTS Page 4

The terminal assignment in CN1 refers to the equivalent assignment in the Aux Port of the standard panel-mount version of the product. This correspondence will be useful to adapt the normal cable drawings for use with the handheld device. CN3 PLC Port CN4 Power 1 CHA+ 1 +24 VDC 2 CHA- 2 Common 3 CHB+ 3 Reserved 4 CHB- 4 PE 5 +5V output (max 100 ma) 6 GND CN5 Additional Signals 7 RXD 1 Dead man button R (NO contact) 8 CTS 2 Dead man button R (NO contact) 9 TXD 3 Dead man button L (NO contact) 10 RTS 4 Dead man button L (NO contact) The Emergency Stop button is hardwired directly to the cable: the corresponding signals do not appear listed in the connectors. The epalm10-0061 includes a communication cable with a length of 5 meters. The cable does not have a connector on its free end as it is intended to be wired directly in the control cabinet. The connections are color-coded according to the table below. Signal Color S mm 2 AWG (approx) Power +24 VDC Red 0.5 20 Common Black 0.5 20 PC/Printer Port GND Grey 0.14 26 RXD Orange 0.14 26 CTS Brown 0.14 26 TXD White 0.14 26 RTS Pink 0.14 26 +5V Output Green 0.14 26 PLC Port CHA+ Blue-Red 0.14 26 CHA- Blue-Black 0.14 26 CHB+ Violet-Red 0.14 26 CHB- Violet-Black 0.14 26 +5V Output Red 0.14 26 GND Black 0.14 26 RXD Brown-Pink 0.14 26 CTS Green-Pink 0.14 26 TXD Orange-Pink 0.14 26 RTS Yellow-Pink 0.14 26 Additional Signals DM Right (NO) Cyan-Black 0.35 22 DM Right (NO) Cyan 0.35 22 DM Left (NO) Blue-Black 0.35 22 DM Left (NO) Blue 0.35 22 Page 5

Emergency Stop E-Stop 1 (NC) Green 1 17 E-Stop 1 (NC) Yellow 1 17 E-Stop 2 (NC) Brown 1 17 E-Stop 2 (NC) Orange 1 17 The internal layout of the communication cable is shown in the figure below. Please note that the ferrite toroid is required. Note: the wiring of the Emergency Stop button is to be considered a SELV circuit and it is intended only for connection to low voltage circuits (below 48 VDC). The standard cable layout of the epalm10-0061 and epalm10-0062 includes the signals of the PC/Printer Port and the signals of the PLC Port. It will allow, without further modification, to connect to the handheld device for programming and to set-up a connection to a field device using RS-232, RS-422 and RS-485. If connection to the Aux Port is required, connections wired to the PLC port will have to be manually moved to the Aux Port. When the RS-422 or RS-485 communication is used, it is recommended not to leave floating the RXD and the CTS signals (that are not used in this configuration). The RXD signal it to be connected to GND, the CTS signal is to be connected to the +5V Output. GREEN GREY ORANGE BROWN WHITE PINK Max Wire Length 10cm To Emergency Stop Button CYAN-BLACK CYAN BLUE-BLACK BLUE YELLOW GREEN BROWN ORANGE 4X1mmq Length 25cm BLUE-RED BLUE-BLACK VIOLET-RED VIOLET-BLACK RED BLACK BROWN-PINK GREEN-PINK ORANGE-PINK YELLOW-PINK RED BLACK SHIELD TRACE Connect the Shield Trace Ferrite Toroid The figure shows the assembly of the communication cable. Please note that the ferrite toroid (included in the epalm10 package) is required for proper operation. Page 6

To program the epalm10 you will need to wire at least the power supply and the programming port connections. Connect the epalm10 to the COM port of a PC as indicated in the figure below. Using Optional Fieldbus Modules The epalm handheld HMI can use some of the standard TCM communication modules for connection to fieldbus systems. The list of the TCM module currently supported by the epalm product is the following: TCM module Fieldbus Notes TCM01 Siemens Simatic S7 MPI Suitable for a point-to-point configuration TCM02 Moeller Suconet K Suitable for a point-to-point configuration TCM03 DeviceNet There are limitations in the bus speed and network configuration that can be used TCM08 Profibus DP There are limitations in the bus speed and network configuration that can be used TCM09 CANopen There are limitations in the bus speed and network configuration that can be used Other TCM modules are currently not supported for use in the epalm products. The following notes are important: The TCM module must be plugged into the unit. The epalm must be opened to allow for the insertion of the TCM module. After plugging the module the epalm product must be carefully closed to ensure proper sealing. The default wiring of the Aux Port CN1 must be manually changed to connect the appropriate signals. Fieldbus topologies do not allow long (5-10 meters) drop segments; the wiring must include incoming and outcoming segments for all bus signals. The CA01 interface board does not allow adding terminator resistors to the bus lines. The epalm cannot be used a final node in the network topology unless termination resistors are applied externally. The most common wiring layouts will be described in detail in this chapter. Page 7

Connecting the epalm to the Simatic S7 MPI network It is recommended that the necessary wires are moved from the CN3 connector (PLC Port) to the CN1 connector (Aux Port). We suggest to wire the connections as shown in the table below. The table indicates the wires that must be moved from CN3 to CN1. The signals A and B will have to be connected to the MPI network. Please note that it is not possible to connect the termination resistors in the epalm. CN1 Connector (Aux Port) CN3 Connector (PLC Port) Wires to be removed Pin Signal Color Pin Signal 4 A Blue-Red 1 CHA+ 5 B Blue-Black 2 CHA- 1 GND Black 6 GND Page 8

Indicators and Keypad The standard keypad of the epalm panels is shown in the figure below. Custom artwork may be designed and produced on request. Please inquire for more information. Uni OP 091A There are several dedicated LED indicators on the front panel of the unit. Functions are described in the table below. LED Color Status Meaning red OFF No hardware problems detected BLINK Battery low ON Hardware fault green OFF No key pressed ON While any key is pressed (visual feedback) green OFF Hardware fault ON Unit in operation green BLINK Communication error ON Communication OK red OFF No alarms BLINK Alarm requires acknowledgment ON Alarm active green May be user controlled as LED number 65 using the Macro Editor. Turns ON when recipe/event backup is being performed. Page 9

The RDA mapping of LED indicators is shown in the table below. RDA Bit LED on Key RDA Bit LED on Key L1 F1 L17 L2 F2 L18 1 L3 F3 L19 2 L4 F4 L20 3 / L5 F5 L21 4 L6 F6 L22 5 L7 F7 L23 6 / L8 F8 L24 7 L9 F9 L25 8 L10 L26 9 / L11 L27. L12 L28 +/- L13 L29 L14 L30 L15 L31 L16 L32 The RDA mapping of the keypad is standard. Battery Replacement A lithium battery is required for data back-up. The following information is maintained by the battery: Hardware real time clock Event list Recipe data Note: replacing the battery will cause the loss of the data maintained by the battery. To replace the battery follow the procedure listed below: 1) turn off the power to the device 2) using a screwdriver loose the 6 screws securing the plastic enclosure 3) open the handheld; the battery is located on the CPU subsystem 4) remove the battery 5) replace the battery with a new one 6) close the handheld and tighten the six screws 7) apply power to the handheld and check that the battery good status is reported. Battery Page 10

Accessories The following accessories are currently available for the epalm10 products: hooks for hanging the handheld device. Hooks are available in two versions, AHOOK01 without magnet and AHOOK02 with a magnet. The hook with the magnet is shown in the figure below. Ordering Information epalm10-0061 epalm10-0062 AHOOK01 AHOOK02 epalm10 HMI with cable (length 5 meters) epalm10 HMI with cable (length 10 meters) Hook set without magnet Hook set with magnet Tn151 Copyright 2001 Sitek S.p.A. Italy Subject to change without notice www.exor-rd.com Page 11