Laboratory Switch Mode Power Supply Series. Instruction Manual

Similar documents
NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

NTP-6621 / 6631 / 6661 SWITCHING MODE POWER SUPPLY with USB REMOTE CONTROL

CIRCUIT-TEST. Switching Mode Power Supply with USB Remote Control PSC VDC / 5A PSC VDC / 3A PSC VDC / 1.

User's Guide. Model W 3-in-1 Switching DC Power Supply

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

80W (16V/5A) Power Supply with USB Output. User Manual

HCS-3200/3202/3204 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

1-36V, 0-3A DC Power Supply

Model DCP42 160W Laboratory Grade Constant Power, Switching Mode Power Supply

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual

99 Washington Street Melrose, MA Phone Toll Free Visit us at INSTRUCTION MANUAL

High Precision Quad Output DC Power Supply

LABORATORY GRADE REMOTE PROGRAMMING SWITCHING MODE DC REGULATED POWER SUPPLIES SDP / 3636 / User Manual

HCS-3200/3202/3204 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Model DCP60 and Model DCP Switching Mode DC Power Supplies 60V / 10A Adjustable USER GUIDE

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply PSC-6118 PSC-6136 PSC A 5A 2.5A

LABORATORY GRADE. REMOTE PROGRAMMING SWITCHING MODE DC regulated Power Supplies

INSTRUCTION MANUAL. Triple Output DC POWER SUPPLY MODELS 1651A & 1652 MODELOS 1651A & El Manual de la Instrucción

Programmable Switching DC Power Supply

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply PSC-6916 PSC-6932 PSC A 30A 15A

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

User's Guide. Model High Precision Quad Output DC Power Supply

User Guide True RMS Multimeter Extech EX205T

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

Mini Digital Multimeter

Universal AC Power Source + AC Power Analyzer

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Users Manual. Two Forward Switching Power Supply ZM500/600-LX. Ver

Mini Digital Multimeter

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

Installation Instructions H Series

INSTRUCTION MANUAL MODELS: 1760A, 1761, Triple Output DC POWER SUPPLY With Dual 4-Digit LED Displays

Operating Instruction Manual POWERED MIXER. Model MX-401. Toa Electric Co., Ltd. KOBE, JAPAN

Model A Mini AC/DC Clamp Meter. User's Guide

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

Digital Clamp Meter User Manual

DC POWER SUPPLY. Model: PW-3063R / PW-4063R

Multiple Output Linear DC Power Supply

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

DC Power Supply Models AX501, AX502 & AX503

±15 V Current-Limited Power Supply

Dual Range DC Power Supply

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

A120 A W/240W PA Mixer-Amplifier 70V/100V

USER S MANUAL DC REGULATED POWER SUPPLY

Dual Range DC Power Supply

Operating instruction Manual POWERED MIXER. Model MX-101. Toa Electric Co., Ltd. KOBE, JAPAN

BENCHTOP INSTRUMENT. Programmable Switching DC Power Supply Operation Manual V1.0

SFP450-12BG AC-DC Front-End Data Sheet 12V Output, 450 Watts

TABLE OF CONTENTS 1. SAFETY PRECAUTIONS GENERAL DESCRIPTION FEATURES AND FUNCTIONS 4. CONNECTIONS 6. APPLICATIONS...

OPERATING INSTRUCTION

Model R5010. TRMS Digital Multimeter. Instruction Manual

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

Operating Instructions. LSP-KONSTANTER Series 32K Laboratory Power Supply 8/10.13

User's Guide. Digital Multimeter. Model MN42

USER MANUAL. True RMS Multimeter. Extech EX430A

Keysight U8030 Series Triple-Output DC Power Supplies

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

AIM & THURLBY THANDAR INSTRUMENTS

Autoranging True RMS Multimeter User Manual

AutoRanging Digital MultiMeter

LED Indicator. Class I

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

USER'S MANUAL DCL-650

AIM & THURLBY THANDAR INSTRUMENTS

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

LABORATORY GRADE. REMOTE PROGRAMMING SWITCHING MODE DC regulated Power Supplies. SDP Series SDP 2210 / 2405 / 2603 User Manual

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

OWNER S MANUAL GEQ 131/ 131LF GEQ 215/ 215LF GEQ 231. Single Channel 31 Band Graphic Equalizer. 2 Channel 15 Band Graphic Equalizer

User's Guide. MiniTec TM Series Model MN25 MultiMeter

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

CompactPCI SYSTEM POWER SUPPLIES. CPCI SERIES 150 to 350 Watts, Ac Input with PFC DPCI SERIES 150 to 350 Watts, 48 Vdc Input FEATURES:

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

PS-5030 (5A) OPERATION MANUAL

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

OWNER'S MANUAL. Model:PSV Amp SWITCHING DC POWER SUPPLY.

500Watts Medical Single Output

AIM & THURLBY THANDAR INSTRUMENTS

Communication & Networking

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

7032 Digital-Analog Multimeter

Series Watt DC Power Supplies

SWA watt Subwoofer Amplifier with DSP and Presets

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Simple but elegant look and ease of installation make it ideal for various industrial applications.

PS-1030 (30V) OPERATION MANUAL

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

Mini Digital Multimeter Model MN15. User's Guide

Features. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Output Connectors. Overvoltage Protection. Over Temperature Protection

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Sorensen SG Series kw V A. Programmable Precision High Power DC Power Supply

1. Chapter 1 24/48/110/220VDC Power Supply System

1. Safety Precautions. 2. Components. 3. Notes on Installation. Caution. Warning

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

Transcription:

Laboratory Switch Mode Power Supply Series Instruction Manual Model 72-8340 1.0 ~ 60VDC 0 ~ 1.6A 72-8345 1.0 ~ 36VDC 0 ~ 3A 72-8350 1.0 ~ 20VDC 0 ~ 5A Copyright 2008, all rights reserved Tenma Test Equipment www.tenma.com

Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation instructions for correct use of the power supply. Read through the manual and pay special attention to the markings and labels of this unit and equipment to be connected. Pay special attention to these two types of notices used in this manual. WARNING Failure to observe this warning may cause injury to persons and damage to power supply or connected equipment CAUTION Failure to observe this warning may result in damage to equipment and improper functioning of the power supply. WARNING: 1. Do not use this power supply near water. 2. Do not operate or touch this power supply with wet hands. 3. Do not open the casing of the power supply when it is connected to AC power source. 4. Refer all servicing to qualified service personnel only. 5. Before replacing the AC fuse first determine and correct the cause or the blown fuse. Replace the AC fuse with the same type and rating as the original fuse. CAUTION: 1. Use only a properly grounded AC power source. 2. This unit is for indoor use only. 3. Do not operate or place this unit in a humid or dusty environment, in direct sunlight or near any heat source. 4. Before plugging into AC power source, check with the rating label at the back of the unit. 5. Do not block ventilation openings on the unit. 6. This unit must be used within the specified rating. Continuous excessive loading may cause damage to the power supply. 7. The AC power cord must be at least 18AWG, and not exceed 3m in length. 8. Replacement fuse: T3AL250V (3A Time-Lag) Environmental condition requirements: 1. 10-80% R.H. 2. Altitude up to 2000m 3. Installation category: CAT 2 4. Pollution degree: 2 5. Maximum supply voltage fluctuation: ±10% of specified operating voltage. Introduction This precision series of switch mode laboratory DC power supplies are ideal for test, measurement and service applications where tight voltage and current regulation are critical. Highly efficient switch mode design delivers outstanding performance from an extremely compact footprint. Unique separate output ON/OFF control allows voltage and current setting, with the supply output turned off. Features: Backlit four digit LCD display Simultaneous display of voltage and current Auto selecting constant voltage (CV) and constant current (CC) modes Ultra quiet convection cooling Short circuit, overload, over voltage and thermal protection 84% efficiency at maximum output RoHs compliant

Front / Rear Panel Controls and Indicators 1. POWER Master on/off selector 2. INPUT POWER jack For connection of supplied AC power cord. 3. FUSE HOLDER May be opened with screwdriver when power cord is removed. 4. VOLT Output voltage adjustment 5. CURR Current limit adjustment 6. OUTPUT ON/OFF Activates supply output 7. OUTPUT (+) Positive supply output (red) 8. OUTPUT (GND) Chassis ground terminal (green) 9. OUTPUT ( ) Negative supply output (black) 10. LCD isplay Panel Backlit panel shows CC/CV Mode, Output status, Voltage and Current output. Operation Ground Connection Depending on the application, the power supply output terminals can be grounded to suit any one of the following conditions: Negative Ground Black (-) negative terminal is tied to the green GND terminal. Positive Ground Red (+) positive terminal is tied to the green GND terminal. Floating Ground Green terminal is left open. Note that in this mode, high impedance leakage can exist between thepower supply circuitry and the chassis ground.

Basic Mode of Operation This power supply is designed to operate as either a constant voltage or constant current source. Automatic crossover to either mode of operation occurs when the load condition changes. The power supply functions as a constant voltage source (CV) as long as the load current is less than the preset current limit value. When load current is equal to or greater than the preset current limit, the power supply will automatically cross over to constant current (CC) mode. The voltage will drop, (CC) will show on the LCD display panel and the power supply will operate as a constant current source. When the load current drops below the preset current limit, the supply will return to constant voltage (CV) mode. Operation Make certain the AC power cord is connected to a proper power source. Make certain that no load is connected to the supply. Switch on master ON/OFF POWER switch (1) on the rear panel, the LCD display backlight should illuminate. The (CV) icon should be shown on the display and the OUTPUT (6) should default to OFF. If current limiting is not required, turn the CURR (5) control fully clockwise. If current limiting is required, see the steps in the following section Presetting a Current Limit Value. Press the OUTPUT (6) button to activate the power supply output. Set your desired output voltage, and then press OUTPUT (6) again to deactivate the output. Observing correct polarity, connect to your load to the power supply. Press the OUTPUT (6) button to activate the power supply output. Check the power supply display to verify that the (CV) icon is displayed. If (CC) is displayed, your current limit value is too low, the load requires more current than the supply is capable, or there is a fault in the connected device. Presetting a Current Limit Value (CC) In many cases, it becomes necessary to preset the current limit prior to having the load connected to the supply. To accomplish this, the following steps should be followed. With no load connected to the supply, switch on the power. Press the OUTPUT (6) button to the ON position to activate the supply output. Adjust the VOLT (4) control to approximately 3VDC output. Press the OUTPUT (6) button again to deactivate the supply output. Turn the CURR (5) control fully counterclockwise. Short OUTPUT terminals (7) and (9) together Press the OUTPUT (6) button to the ON position to activate the supply output. Adjust the CURR (5) control clockwise until the desired current limit is displayed. Press the OUTPUT (6) button again to deactivate the supply output and remove the short between terminals (7) and (9). The supply is now set for this current limit throughout its voltage range. Protection To provide protection to the power supply and the connected load, the supply incorporates over voltage (OVP) thermal protection. Traditional power supplies often provide over current protection, however that benefit already exists by sheer design of a current limiting supply. Over Voltage Protection ( OVP ) In the event that the output voltage control circuit mal-functions, the maximum output voltage will not exceed 30% of the adjusted voltage value at the time of the operation. Over Temperature Protection If the temperature inside the supply exceeds a pre determined value, the output voltage and current of the supply will decrease to zero to prevent damage to the supply. When the temperature inside supply returns to approximately 65 C (150 F), the power supply will automatically return to operation.

Specifications Model 72-8340 72-8345 72-8350 Input Voltage 90 ~ 130VAC, 50~60Hz Full Load Input Current 1.6A Output Voltage Range 1.0 ~ 60VDC 1.0 ~ 36VDC 1.0 ~ 20VDC Output Current Range 0 ~ 1.6A 0 ~ 3A 0 ~ 5A Voltage Regulation Load variation from 10% ~ 100% 70mV 50mV 50mV Line variation from 90 ~ 130VAC 20mV Ripple and noise (RMS) 5mV Ripple and noise (p-p) 30mV 30mV 50mV Current Regulation Load variation from 10% ~ 100% Line variation from 90 ~ 130VAC Ripple & Noise (peak to peak) Switching Operation Frequency 80KHz ~ 120KHz Power Factor 0.68 Efficiency at Maximum Power 84% 85% 85% Voltmeter Display 4 Digit Ammeter Display 4 Digit Voltmeter Accuracy ±1% +5 counts ( 5V) ±1% +5 counts ( 10V) ±1% +5counts ( 20V) ±1% +3counts (>5V) ±1% +3counts (>10V) ±1% +3counts (>20V) Ammeter Accuracy ±1% +5 counts ( 2A) ±1% +5 counts ( 1A) ±1% +5 counts ( 0.5A) ±1% +3 counts (>2A) ±1% +3 counts (>1A) ±1% +3 counts (>0.5A) LCD Indication CC, CV, Amp, Volt, Output ON-OFF Protection Short Circuit, Overload, Over Temperature, Tracking OVP CE Approvals LVD : EN 61010, EMC : EN 55011 Cooling System Natural Convection Dimensions (WxHxD) 70mm x 150mm x 250mm / 2.8" x 6.0" x 9.8" Weight 2Kgs / 4.4 lbs.