Standard Series Key features: Wide power range: 7.W-24W Universal input : 7.W-W: 8-264V AC/1-37V DC 1W: 8-2V AC/17-264V AC 24-37V DC (selectable) W, W, 24W: 8-264V AC/11-3V DC Overcurrent/overvoltage protection Power Factor Correction (W, W, 24W models) EN61-3-3 EN61-3-2 adjustment +1% Spring-up crew terminal, IP2 (finger-safe) DIN rail or panel surface mount Approvals: CE marked UL 8 Listed c-ul TÜV approved EMC Directives: EN81-2 EN82-2 EN61-6-2 LVD EN9:2 Style Watts 7. 1 3 Current Standard Series Switching Part Number V DC 1.A -A V DC.6A -A 24V DC.3A -A24 V DC 2.A -B V DC 1.2A -B 24V DC.6A -B24 V DC 2.A -C 24V DC 1.3A -C24 24V DC 2.1A -D24 Part Numbers Style UL 8 Listed File #E177168 Cert No. BL982332392 Watts Current Part Number 24V DC 3.1A -Q24 1 24V DC 4.2A -E24 24V DC A -F24 24 24V DC 1A -G24 OI Touchscreens PLCs Automation Software Sensors Communication Barriers Phone: 8.894.4 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Standard Series Specifications Barriers Communication Sensors Automation Software PLCs OI Touchscreens Model -A -B* -A -B -C -A24 -B24 -C24 -D24 -Q24 -E24 -F24 -G24 Output Capacity 7.W 1W 3W W W 1W W 24W Input Output Input (singlephase, 2-wire) Input Current (typical) 1 to 24V AC nominal (8 to 264V AC), /Hz (47 to 63Hz) 11 to 34V DC nominal (1 to 37V DC).17A at 1V AC.3A at 1V AC.68A at 1V AC 1.1A at 1V AC 1.1A at 1V AC 1 to V AC, /Hz 2 to 24V AC, /Hz (jumper selectable) 24 to 37V DC 2.A at 1V AC 1.A at 2V AC 1 to 24V AC, /Hz, 11 to 34V DC 1.8A at 1V AC Internal Fuse Rating 2A 2A 3.1A 3.1A 3.1A 4A 4A 6.3A Inrush Current Leakage Current (at no load) Typical Efficiency Overvoltage Protection and Current Ratings A maximum (at cold start at 2V AC) V, 1.A V,.6A 24V,.3A 69% at V % at V 79% at 24V V, 2.A V, 1.2A 24V,.6A 7A maximum (at cold start at 23V AC) A maximum (at cold start at 2V AC).mA maximum (Hz, measured in conformance with UL, CSA, VDE) % at V % at 24V V, 2.A 24V, 1.3A 4A at 1V AC 7A maximum (at cold start at 23V AC) 79% at 24V 83% at 24V 8% at 24V 83% at 24V Outputs turns off at 1% (typical) 24V, 2.1A 24V, 3.1A 24V, 4.2A 24V, A 24V, 1A Adjustments ±1% ( screw on top) Output Holding Time 2ms minimum (at full rated input and output) Rise Time 2ms maximum (at full rated input and output) 1ms max. Line Regulation.4% maximum Load Regulation 1.% maximum Fluctuation due to Ambient Temperature.% maximum Change Ripple 2% peak to peak maximum (including noise) Overload Protection % typical (Zener-limiting) % typical, auto reset Operation Indicator LED (green) Parallel Operation -A -B -C -D -Q -E -F -G Allowed No Yes No Yes Between input and output terminals: 3,V AC, 1 minute Dielectric Strength Between input terminals and housing: 2,V AC, 1 minute Between output terminal and housing: V AC, 1 minute Insulation Resistance Between input and output terminals/input terminals and housing: 1MΩ minimum (V DC megger) Operating Temperature 1 to + C (14 to 14 F) (see derating curves) Storage Temperature 3 to +8 C (-22 to 18 F) Operating Humidity 2 to 9% relative humidity (no condensation) Vibration Resistance 4m/s 2, 1 to Hz, 2 hours on each of 3 axes 1 to Hz,.mm p-p, 2 hrs on each of 3 axes Shock Resistance 3m/s 2 (3G), 3 shocks in each of 6 directions Approvals Conforms to EMC Directives EN81-2 & EN82-2. LVD Directive EN29 Certified to EN9. UL8 listed. c-ul, TUV approved. CE marked. EN61-3-2 Weight 1g 17g 3g 39g 8g g g 2g Termination Spring-up, fingersafe terminals with captive M3. screws IP protection IP2 (finger safe) Dimensions H x W x D (mm) x 4 x 7 x 4 x9 x 9 x 9 x 9 x 9 x 8 x 14 x 14 x 9 x 11 x14 x 2x 14 Dimensions H x W x D (inches) 2.9 x 1.77 x 2.76 1. For dimensions, see page 11. 2. For usage instructions, see page 1. 2.9 x 1.77 x 3. *.W for VDC model. 2.9 x 3.4 x 2.9 x 3.4 x 4.72 x 3.3 x.2 2.9 x.71 x 4.72 x 4.3 x.2 4.72 x 7.87 x.1 Phone: 8.894.4 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Standard Series -A/B 1 9 8 7 4 3 2 1 1 1 2 3 4 -E 1 9 8 7 4 3 2 1-1 -F/G 1 2 3 4 Operating Temperature ( C) 1 9 8 7 4 3 2 1 1 2 3 3 4 Temperature Derating Curves -C/D 1 9 8 7 4 3 2 1 1 1 2 3 3 4 -Q Mounting Style B A Mounting (standard) Mounting Style A Mouting style A 1 9 8 7 4 3 2 1 1 2 3 4 Vertical B Mounting (Facing Upward) Vertical OI Touchscreens PLCs Automation Software Sensors Communication Barriers Phone: 8.894.4 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Standard Series OI Touchscreens Accessories Part Numbers: Accessories Appearance Description Part Number DIN rail (1mm) BNDN1 Overcurrent Protection Characteristics -A/B Output (%) 1 PLCs DIN rail end clip BNL 11 Installation Instructions -C/D/E Time-Saving Spring-up Terminals 1 Automation Software The innovative terminals on the series use a spring-loaded screw. This makes installation as easy as pushing down and turning with a screwdriver. Installation time is cut in half since the screws do not need to be backed out to install wiring. The screws are held captive once installed and are 1% finger-safe. Screw terminals accept bare wire or ring or fork connectors. 1. Insert the wire connector into the slot on the side of the power supply. Output (%) 1 1 Sensors 2. Using a flat head or Phillips screwdriver, push down and turn the screw. The wire is now connected, and the screw terminal is fingersafe! Front Panel (terminals) Markings Name Description V. ADJ adjustment Operation indicator Adjusts within ±1%; turn clockwise to increase output voltage Green LED is lit when output voltage is on + - Parallel Operation TERMINALS ELECTRICAL LOAD Communication +V, V L, N DC output terminals Frame ground Input terminals No connection +V: Positive output Terminal V: Negative output terminal Ground this terminal to reduce high-frequency currents caused by switching Accept a wide range of voltages and frequencies (no polarity at DC input) Do not insert wires here, as this may damage the power supply Barriers 1. Parallel operation only recommended for -Q24, -F24 and -G24. 2. Factory recommended diode ST Microelectronics BYV4V-, BYV4V-1, BYV4V-2, BYV41V-2 or with equivalent electrical specifications. 3. Using the voltage adjustment make sure out-voltage is the same for all power supplies. Phone: 8.894.4 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Standard Series 62. R2.2 6-ø6. 3 38. 14 2-24V Dimensions -A (7.W) -B (1W) -C (3W) 1-ø6. 9 8 62. R2.2 6-ø6. 3 38. 8 11 11 4.6 26 19 2 1-ø6. -D (W) -Q (W) -F (W) -E (1W) 14-ø6. Terminal Markings -A/B -C/D/Q/F/G -E -V +V L N V +V L N -G (24W) 11 9 8 16 1 11 V +V 1w-OUTPUT VOLTAGE SELECT L N 2-24V 1-V 11 11 OI Touchscreens PLCs Automation Software Sensors Communication Barriers 2-24V Phone: 8.894.4 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com