Technical Datasheet clima RCM-CC

Similar documents
Technical Datasheet clima RCM-FC 1. Product description

Technical Datasheet clima BSK4-F / BSK4-F230 NK mêççìåí=çéëåêáéíáçå

252F 5WG FB_1 DELTA

Product and Application Description

TAC Xenta 121-FC Programmable Fan Coil Application

User manual clima DL-110

Glass sensors 35. Supplementary products 39

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

DDC110-L1.. DDC110-L4 technolon Room Module

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

User Manual LON MSeries. Moers, 22/01/2013. Version

Room unit with PPS2 interface

Product and Function Description

Control Head for the integrated mounting on process valves

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Push button UP 287, 4 - fold

584 5WG AB_1 DELTA

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

VersaMax IP I/O Module

XPSMCMDO Digital output pairs expansion modules with screw term

Product and functional description

IB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B

XPSMCMDI Input expansion module with screw term

TAC Xenta 121-HP Programmable Heat Pump Application

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Digital electropneumatic positioner

Room unit with PPS2 interface

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

Installation Instructions

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

DI561 Digital Input Module

Control Head for the integrated mounting on process valves

XPSMCMMX inputs 2 output pairs expansion module with screw term

Control Head for the integrated mounting on process valves

Room unit with PPS2 interface

Product and functional description

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

DELTA i-system wall switch single UP 221/2 5WG AB_2

RCW11x-L Room Controller Technolon. Application. Product Description. RCW11x-L Room Controller Technolon

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

DI572 Digital Input Module

KNX T-UP. Temperature Sensor. Technical specifications and installation instructions

Air Quality Sensor KNX AQS

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

Power Supply HARTING pcon

Incremental Encoder with Hollow Shaft

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

Pneumatic Control Unit for the integrated mounting on process valves

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN

TM3AI4 module TM3-4 analog inputs

DC562, digital input/output module,

SITOP in the SIMATIC Design

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

PHOENIX CONTACT - 05/2007

Switched Mode Power Supply Operating manual PAP800

Digital electropneumatic Positioner for the integrated mounting on process control valves

UCU Room Display. Operation Modes. Features. Applications DATASHEET

Safety controller unit B1 /

Product and function description

Digital electropneumatic Positioner for the integrated mounting on process control valves

Switches and Indicators 84

Power Supply HARTING pcon

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

DC561, digital input/output module,

VersaMax IP Input Module

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

FL MC 2000E (SM40) LC

Digital electropneumatic Positioner for the integrated mounting on process control valves

TM3TI8T module TM3-8 inputs temperature

Digital electropneumatic Positioner for the integrated mounting on process control valves

Communicative controller for VAV systems

The output variables can be force-controlled from a coordinating control system.

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

IBS IL 24 BK RB-T-2MBD

RoHS. High shaft load capacity. Shock / vibration resistant

LED Driver Compact fixed output

Blu2Light Light Management Installation in Luminaires

AS-Interface I/O Module

KNX/EIB Push button sensor 3 Plus F Safety instructions. 2 Device components. 3 Function

PHOENIX CONTACT - 10/2009

QUINT-PS/ 1AC/24DC/ 5

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

DX561 Digital Input/Output Module

OTi DALI 75/ /700 D LT2 UF L

TM3TI4 module TM3-4 inputs temperature

Transcription:

Technical Datasheet 1. Product description The is a room control panel with an integrated temperature sensor for measuring the room temperature. The device is featured with a turn wheel to adjust the set point and up to two push buttons including LEDs for presence status and fan speed control. The room control panel has 6 digital inputs to connect light-, blind-, presence- switches, window contacts or due point sensors. Additionally two analogue outputs (0-10 V) are available to control valve actuators for radiators or heating- /cooling-ceilings. Unit comes with jumper ring for mounting on cavity wall sockets or flush mounting sockets according to DIN VDE 0606. The front panel is designed for a standard 55 mm spacing and suits perfectly to the corresponding switch ranges from manufactures like Berker, Gira, Jung and Merten. For this reason the clima RCM offers the architect the complete freedom of choice in finding the suitable switch range design. An easy LNS-Plug-In for a comfortable configuration is available. without push-button with presence- pushbutton with presence- pushbutton (All Pictures show clima RCM together with 55 mm frame. The frame is not included in the purchased parts package) Page 1 of 8

2. Mounting and installation 2.1. Mounting Electrical devices must be assembled and installed by trained personnel only. Install the LON room temperature controller in a flush-mount switch socket with a recommended minimum depth of 47mm. Mounting must be done at representative locations for room temperature measurements in order to have an undisturbed measurement. Direct sunlight and air drafts are to be avoided. All 55mm spacing switch frames are suitable for this product. On units with set point dial, the screw to fasten the cover is beneath the dialing wheel. The dialing wheel can be pulled carefully from its axis. The LON service switch on units of the RCM-xx series can only be operated when the cover is removed. Before mounting the unit inside an flush-mount switch socket all cables have to connected. Afterwards the LON room temperature controller can be inserted into the socket and fixated with screws. The switch cover is put onto the metal ring and fixated by the room temperature cover. As a last step for units with the set point dial, the dial wheel is gently pushed onto the axis. 2.2. Dimensions 78 mm 40 mm 78 mm 49 mm Page 2 of 8

2.3. Connections 2.3.1 Layout of the connectors Digitaleingänge E 5,E6 & FC-BOX Kommunikation Spannungsversorgung & LON-BUS Digitaleingänge E 1 E4 figure 1 +2 4V GN AC D /DC /M AS SE LO N LO B N A 2.3.2 power supply and LON connections figure 2 Connection function type +~ power supply typ. +24V DC / AC power supply GND ground power supply A LON A LON bus connection B LON B LON bus connection Page 3 of 8

2.3.3 digital inputs E1 - E4 E1 E2 E3 E4 max. 6mm figure 3 connection function type E1 digital input 1 input E2 digital input 2 input E3 digital input 3 input E4 digital input 4 input 2.3.4 LON Service switch The LON service switch is only accessible when the cover is not mounted. Gently pull the dial wheel off. Beneath is a screw that holds the cover. After loosening of the screw the cover can be removed. Be careful not to damage the printed circuit boards found inside of the unit! The LON service switch is on the middle printed circuit board. You can operate it using a small screw driver. To the lower right the service LED can be seen. See the picture below: Page 4 of 8

LON ServiceTaster figure 4 figure 5: operate service switch with screw driver Page 5 of 8

2.4. Connection example A LON B -/ 24V + / +/~ -/~ 24V B A LON RCM-CC / RO-CC E E E E E E V V 1 2 3 4 5 6 1 2 Page 6 of 8 +/~ -/~ 0-10V Stellantrieb/ valve actuator

3. Technical data Power Supply Operating voltage Power consumption 24V DC +/-15% or 24V AC +/- 15% max. 1,44 W Network Network type Transceivertype TP/FT-10 (78kbps) FTT Connections Network Digital inputs (for connection to push-buttons or potential free-contacts) Analog outputs 0-10V Control elements Service push-button Set point adjuster turn wheel Upper right push-button Lower left push-button Display elements LEDs 4-pin plug-in terminal connection for solid wires Ø 0,6-1,0mm four bus lines can be connected for each pin 6 digital inputs: E1-E4: 4-pole clamp connection for solid or flexible wires Ø max. 0,8mm E5, E6: 2-pole clamp connection for solid or flexible wires max. 1.5 mm² 2x analog output 0-10 V, max. 5 ma V1, V2: 2-pole clamp connection for solid or flexible wires max. 1.5 mm² Sends Neuron-ID when pressed Adjusts the temperature set point Range between+/- 1-5 K; range per software adjustable only order-no. 231x03: Presence control push-button,toggles presence status none order-no. 231x02: none order-no. 231x03: Red: Heating mode Blue: Cooling mode Yellow: Window contact Green: Presence Measurement range Measurement range +5 C to +50 C Measuring tolerance Measuring tolerance +/- 0,5 K (in the range of +5 C > T > +30 C) Housing Type of protection Dimensions Type / location of installation IP 20 (DIN 40050 / IEC 144) 70 x 70 x 41 [mm] (H x B x T) Mounting on cavity wall sockets or flush mounting sockets according to DIN VDE 0606 Ambient conditions Operating temperature Storage temperature Transportation temperature Rel. humidity Installation height -5 C... +45 C -25 C... +55 C -25 C... +70 C 5 %...93 % (without condensation) Up to 2000 m above sea level Safety Electrical isolation Class of protection SELV (EN 60 950) I (IEC 536 / VDE 106 Teil 1) Standards / guidelines Device safety Immunity Certification Acc. EN 50 090-2-2 Acc. EN 50 090-2-2 CE Page 7 of 8

4. Product 4.1. Order information Order number 231 342 W 231 342 B 231 342 A 231 343 W 231 343 B 231 343 A Description, without presence-button, six digital inputs, two analogue outputs 0-10 V, pure white, without presence-button, six digital inputs, two analogue outputs 0-10 V, anthracite, without presence-button, six digital inputs, two analogue outputs 0-10 V, aluminium, with presence-button, six digital inputs, two analogue outputs 0-10 V, pure white, with presence-button, six digital inputs, two analogue outputs 0-10 V, anthracite, with presence-button, six digital inputs, two analogue outputs 0-10 V, aluminium 5. Support The information given in this manual has been carefully collated. Should you have any further questions relating to this product, please contact: spega - Spelsberg Gebäudeautomation GmbH Zechenstr. 70 D-47443 Moers Fon: +49 (2841) 88049-0 Fax: +49 (2841) 88049-49 Email: support@spega.de Page 8 of 8