Optical distance sensors. Dimensioned drawing

Similar documents
Optical laser distance sensors. Dimensioned drawing

Retro-reflective photoelectric sensors. Dimensioned drawing. Receiver Transmitter Optical axis LED yellow 90 turning connector. Electrical connection

Retro-reflective photoelectric sensors with polarisation filter. Dimensioned drawing. Electrical connection

Energetic diffuse reflection light scanner. Dimensioned drawing

Leuze electronic. 96 Series. Product description

Trigger high-speed, retro-reflective sensors for bottles. Dimensioned drawing

Electrical connection

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Optical distance sensors. Dimensioned drawing

Measurement range, typical

DIFFUSE REFLECTION SCANNERS

Diffuse reflection light scanner with background suppression. Dimensioned drawing

3B Series PRODUCT DESCRIPTION

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing

Measurement range, typical

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Leuze electronic. 25 Series. Product description

Retro-reflective photoelectric sensors with polarization filter. Dimensioned drawing

Laser retro-reflective photoel. sensors with polariz. filter for bottles. Dimensioned drawing

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing

Electrical connection

L-LAS Series L-LAS-LT-55. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-55 (incl. Windows - software L-LAS-LT-Scope)

RS485 (S85- -Y13) Display (S85- -Y13) Setting push-buttons (S85- -Y03) Power supply Vdc 24 V +/- 20% PNP NPN Output Push pull

PRODUCT INFORMATION. G6 Global Sensor. Beyond the standard Global sensor the economic way to business class

Basic Series 18 mm Diameter Cylindrical Sensors

Mounting. possibilities. Transmitter optics. 8-pole fem. connector Binder Series 712 (PLC) Connecting cable: cab-las8/sps or cab-las8/sps-w

Optical Distance Sensors ODSL 8 / ODSL 30 / ODS 96

L-LAS Series. L-LAS-TB-F-8x1-30/40 L-LAS-TB-F-1x8-30/40. Design. L-LAS Series Laser Line Sensors. Product name:

Dimensioned drawing. Measurement principle

Photoelectrics Retro-reflective, Polarized Type PA18C.P..., DC

Photoelectrics Retro-reflective Type PA18C.R..., DC

MLV41 Series Miniature Sensors

Dimensions. Model Number. Electrical connection. Features. Indicators/operating means. Product information OQT150-R100-2EP-IO-IR

0,25 mm false pulse suppression 4 program options 4 program options on/off switchable 4 preset levels or level set by customer.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Dimensions. Model Number. Indicators/operating means. Features. Electrical connection. Product information OQT150-R100-2EP-IO-V31-L

SENSORS FOR POTENTIALLY EXPLOSIVE AREAS

Dimensions. Model Number. Electrical connection. Features. Pinout. Product information. Indicators/operating means OMT300-R201-IEP-IO-V1

Dimensions. Model Number. Electrical connection. Features. Pinout. Indicators/operating means. Product information OQT150-R100-2EP-IO-V31

LASER SENSOR. Series LAS-T5 and LAS-T. Key-Features:

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

The World s Smallest TOF Sensor lineup with analog output type

sks-15/cd Extract from our online catalogue: Current to:

Photoelectrics Diffuse-reflective Type PA18C.D..., DC

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

ParCon and PosCon line sensors

Slot Style Photoelectric Sensors

FL MC 2000E (SM40) LC

Dimensions. Model Number. Electrical connection emitter. Features. Electrical connection receiver. Product information. Pinout OBE12M-R100-S2EP-IO-V31

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

! Protected against mutual interference. ! DIN rail mounting

sks-15/d ::: sks ultrasonic sensors ::: proximity switch/reflective mode reflective barrier window mode narrow sound field transducer frequency

C5 Series Stainless Steel Photoelectric

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes.

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Sensors. Compact: S60 Series. Compact: S60 Series. Multifunction Optoelectronic Sensors

Inductive proximity switches with long operating distance, series 500

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs

LCC Series LCC-130-MA. Design. LCC Series Laser Copy Counters. Product name: Accessories: LCC-130-MA (incl. Windows PC Software SI-LCC-MA-Scope)

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

3RG7 Opto-BERO Photoelectric Proximity Switches

Optimum sensing capability for LCD manufacturing

Fork light barriers SOOF

We Bring Light into the Dark. Reliable Differentiation also of Dark Colors.

Contact protection relay

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves

Pressure sensors SDE1, with display

Sturdy aluminium housing, aodized in black. LED red (-): Measuring value < lower tolerance threshold

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Photoelectric Sensors E3F2

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Fork light barriers SOOF

ML20 Series Long-Range Miniature Sensors

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

Series 28 Universal Sensors

12 m 8 m 6 m 3 m 300 mm 500 mm 70 mm mm Power supply Vdc Vdc

Opto Proximity Switches

Temperature Switches

ML17 Series Tru-Vue TM Sensors

SENSORS SR23. Fork Sensors - SR23. High efficiency fork sensor for booklet and multilayer labels detection APPLICATIONS

BACKGROUND SUPPRESSION LHR-C12PA-NM

Linear Position Transducer HLT 1000-R2

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

sks ultrasonic sensors Extract from our online catalogue: Current to:

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

YM24PAH2ABF. Contrast Sensor. LASER Technical Data. Photoelectronic Sensors. Part Number

F3ET Lightcurtain in robust aluminium housing

Linear Position Transducer HLT 1000-R2

PHOENIX CONTACT - 07/2006

Photoelectrics Diffuse-reflective, Background Suppression Type PH18CNB20...

Product description. At a glance. performance in a metal housing coating available Precise autocollimation optics. sensors

Operating instructions Optical distance sensor O1D / / 2012

(threaded M5) 7-pole fem. connector Binder Series 712 (connection Master/Slave) Connecting cable: cab-las7-male not necessary for single system!

ASM1, ASM1E, ASM2E. AS-i Safety Monitor. Subject to change without prior notice. Technische Ă„nderungen vorbehalten /02

Operating instructions Memory plug E /02 11/2011

Online data sheet VTE18-4P4240 V18 CYLINDRICAL PHOTOELECTRIC SENSORS

E3Z. The New Standard for Compact, Long-range Photoelectric Sensors Conserves Energy and Natural Resources, One Million Sold Yearly

Transcription:

Optical distance sensors Dimensioned drawing en 03-2012/11 50110829 120 1400mm 18-30 V DC We reserve the right to make changes DS_ODS96BMV61400S12_en_50110829.fm Reflection-independent distance information Highly insensitive to extraneous light Analogue voltage output PC/OLED display and key pad for configuration Measurement value is indicated in mm on OLED display Measurement range and mode adjustable Switching output and teachable analogue output IEC 60947... IEC 60947... Accessories: (available separately) Mounting systems Cable with M12 connector (K-D ) Configuration software IP 69K IP 67 A Green indicator diode B Indicator diode yellow C Transmitter D Receiver E Optical axis F Device plug M12x1 G Countersinking for SK nut M5, 4.2mm deep H OLED display and key pad I Reference edge for the measurement (cover glass) Electrical connection

Specifications Optical data Measurement range 1) 120 1400mm Resolution 2) 0.1 2mm Light source LED Wavelength 880nm (infrared light) Light spot approx. 15 x 15mm 2 at 600mm Error limits (relative to measurement distance) Absolute measurement accuracy 1) ± 1.5% up to 800mm, ± 2% up to 1400mm Repeatability 3) ± 0.5% up to 800mm, ± 1% up to 1400mm B/w detect. thresholds (6 90% rem.) 1% up to 800mm, 2% up to 1400mm Temperature compensation yes 4) Timing Measurement time 1 5 1) ms Response time 1) 15ms Delay before start-up 300ms Electrical data Operating voltage U B 18 30VDC (incl. residual ripple) Residual ripple 15% of U B Open-circuit current 150mA Switching output push-pull switching output 5), PNP light switching, NPN dark switching Signal voltage high/low (U B -2 V)/ 2V Analogue output voltage 1 10V / 0 10V / 1 5V / 0 5V, R L 2k Indicators teach-in on GND teach-in on +U B Green LED continuous light ready flashing fault teaching procedure no voltage Yellow LED continuous light object inside teach-in measurement distance flashing teaching procedure object outside teach-in measurement distance Mechanical data metal housing Housing diecast zinc Optics cover glass Weight 380g Connection type M12 connector Environmental data Ambient temp. (operation/storage) -20 C +50 C / -30 C +70 C Protective circuit 6) 1, 2, 3 VDE safety class 7) II, all-insulated Protection class IP 67, IP 69K 8) Standards applied IEC/EN 60947-5-2 1) Luminosity coefficient 6% 90%, complete measurement range, at 20 C, medium range of U B, measurement object 50x50mm² 2) Minimum and maximum value depend on measurement distance 3) Same object, identical environmental conditions, measurement object 50x50mm² 4) Typ. ± 0.02 %/K 5) The push-pull switching outputs must not be connected in parallel 6) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs 7) Rating voltage 250VAC, with cover closed 8) IP 69K test in accordance with DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives. Acids and bases are not part of the test A B C D E F Area not defined Linearity not defined Measurement range Object present No object detected Measurement distance Tables Diagrams Remarks Measurement time depends on the reflectivity of the measurement object and on the measurement mode. Approved purpose: This product may only be used by qualified personnel and must only be used for the approved purpose. This sensor is not a safety sensor and is not to be used for the protection of persons. Order guide Designation Part No. With M12 connector ODS 96B M/V6-1400-S12 50110231

ODSR 96B Optical distance sensors Dimensioned drawing en 04-2012/11 50107947 18-30 V DC We reserve the right to make changes DS_ODSR96BMCV6600_en_50107947.fm Reflection-independent distance information Highly insensitive to extraneous light Analogue current or voltage output PC/OLED display and key pad for configuration Measurement value is indicated in mm on OLED display Measurement range and mode adjustable Teachable switching output and analogue output IEC 60947... IEC 60947... Accessories: (available separately) IP 69K IP 67 Mounting systems Cable with M12 connector (K-D ) Configuration software A Indicator diode green B Indicator diode yellow C Transmitter D Receiver E Optical axis F Device plug M12x1 G Countersinking for SK nut M5, 4.2mm deep H OLED display and key pad I Reference edge for the measurement (cover glass) Electrical connection

ODSR 96B Specifications Optical data Measurement range 1) Resolution 2) 0.1 0.5mm Light source LED Wavelength 635nm (visible red light) Light spot approx. 15 x 15mm 2 at 600mm Laser warning notice see remarks Error limits (relative to measurement distance) Absolute measurement accuracy 1) ±1.5% Repeatability 3) ±0.5% b/w detect. thresholds (6 90% rem.) 1% Temperature compensation yes 4) Timing Measurement time 1 5 1) ms Response time 1) 15ms Delay before start-up 300ms Electrical data Operating voltage U B 18 30VDC (incl. residual ripple) Residual ripple 15% of U B Open-circuit current 150mA Switching output push-pull switching output 5), PNP light switching, NPN dark switching Signal voltage high/low (U B -2 V)/ 2V Analogue output voltage 1 10V, R L 2k current 4 20mA, R L 500 Indicators teach-in on GND teach-in on +U B Green LED continuous light ready flashing fault teaching procedure no voltage Yellow LED continuous light object inside teach-in measurement distance flashing teaching procedure object outside teach-in measurement distance Mechanical data Metal housing Housing diecast zinc Optics cover glass Weight 380g Connection type M12 connector Environmental data Ambient temp. (operation/storage) -20 C +50 C / -30 C +70 C Protective circuit 6) 1, 2, 3 VDE safety class 7) II, all-insulated Protection class IP 67, IP 69K 8) LED class 1 (acc. to EN 60825-1) Standards applied IEC 60947-5-2 1) Luminosity coefficient 6% 90%, complete measurement range, at 20 C, medium range of U B, measurement object 50x50mm² 2) Minimum and maximum value depend on measurement distance 3) Same object, identical environmental conditions, measurement object 50x50mm² 4) Typ. ± 0.02 %/K 5) The push-pull switching outputs must not be connected in parallel 6) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs 7) Rating voltage 250VAC, with cover closed 8) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives. Acids and bases are not part of the test. A B C D E F Area not defined Linearity not defined Measurement range Object present No object detected Measurement distance Tables Diagrams Remarks Measurement time depends on the reflectivity of the measurement object and on the measurement mode. Approved purpose: The ODSR 96B distance sensors are optical electronic sensors for the optical, contactless measurement of distance to objects. Order guide Designation Part No. With M12 connector Current output ODSR 96B M/C6-600-S12 501 06730 Voltage output ODSR 96B M/V6-600-S12 501 06731

Optical distance sensors Dimensioned drawing en 04-2012/11 50107945 18-30 V DC We reserve the right to make changes DS_ODS96BMCV6600_en_50107945.fm Reflection-independent distance information Highly insensitive to extraneous light Analogue current or voltage output PC/OLED display and key pad for configuration Measurement value is indicated in mm on OLED display Measurement range and mode adjustable Teachable switching output and analogue output IEC 60947... IEC 60947... Accessories: (available separately) IP 69K IP 67 Mounting systems Cable with M12 connector (K-D ) Configuration software A Indicator diode green B Indicator diode yellow C Transmitter D Receiver E Optical axis F Device plug M12x1 G Countersinking for SK nut M5, 4.2mm deep H OLED display and key pad I Reference edge for the measurement (cover glass) Electrical connection

Specifications Optical data Measurement range 1) Resolution 2) 0.1 0.5mm Light source LED Wavelength 880nm (infrared light) Light spot approx. 15 x 15mm 2 at 600mm Error limits (relative to measurement distance) Absolute measurement accuracy 1) ±1.5% Repeatability 3) ±0.5% b/w detect. thresholds (6 90% rem.) 1% Temperature compensation yes 4) Timing Measurement time 1 5 1) ms Response time 1) 15ms Delay before start-up 300ms Electrical data Operating voltage U B 18 30VDC (incl. residual ripple) Residual ripple 15% of U B Open-circuit current 150mA Switching output push-pull switching output 5), PNP light switching, NPN dark switching Signal voltage high/low (U B -2 V)/ 2V Analogue output voltage 1 10V, R L 2k current 4 20mA, R L 500 Indicators teach-in on GND teach-in on +U B Green LED continuous light ready flashing fault teaching procedure no voltage Yellow LED continuous light object inside teach-in measurement distance flashing teaching procedure object outside teach-in measurement distance Mechanical data Metal housing Housing diecast zinc Optics cover glass Weight 380g Connection type M12 connector Environmental data Ambient temp. (operation/storage) -20 C +50 C / -30 C +70 C Protective circuit 6) 1, 2, 3 VDE safety class 7) II, all-insulated Protection class IP 67, IP 69K 8) LED class 1 (acc. to EN 60825-1) Standards applied IEC 60947-5-2 1) Luminosity coefficient 6% 90%, complete measurement range, at 20 C, medium range of U B, measurement object 50x50mm² 2) Minimum and maximum value depend on measurement distance 3) Same object, identical environmental conditions, measurement object 50x50mm² 4) Typ. ± 0.02 %/K 5) The push-pull switching outputs must not be connected in parallel 6) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs 7) Rating voltage 250VAC, with cover closed 8) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives. Acids and bases are not part of the test. A B C D E F Area not defined Linearity not defined Measurement range Object present No object detected Measurement distance Tables Diagrams Remarks Measurement time depends on the reflectivity of the measurement object and on the measurement mode. Approved purpose: The ODS 96B distance sensors are optical electronic sensors for the optical, contactless measurement of distance to objects. Order guide Designation Part No. With M12 connector Current output ODS 96B M/C6-600-S12 501 06720 Voltage output ODS 96B M/V6-600-S12 501 06721

Optical distance sensors Dimensioned drawing en 02-2012/11 50108381 120 1400mm 18-30 V DC We reserve the right to make changes DS_ODS96BMC66011400_en_50108381.fm Reflection-independent distance information Highly insensitive to extraneous light Analogue current output PC/OLED display and key pad for configuration Measurement value is indicated in mm on OLED display Measurement range and mode adjustable Teachable analogue output 2 warning outputs IEC 60947... IEC 60947... Accessories: (available separately) IP 69K IP 67 Mounting systems Cable with M12 connector (K-D ) Configuration software A Indicator diode green B Indicator diode yellow C Transmitter D Receiver E Optical axis F Device plug M12x1 G Countersinking for SK nut M5, 4.2mm deep H OLED display and key pad I Reference edge for the measurement (cover glass) Electrical connection

Specifications Optical data Measurement range 1) 120 1400mm Resolution 2) 0.1 0.5mm Light source LED Wavelength 880nm (infrared light) Light spot approx. 15 x 15mm 2 at 600mm Error limits (relative to measurement distance) Absolute measurement accuracy 1) ± 1.5% up to 800mm, ± 2% up to 1400mm Repeatability 3) ± 0.5% up to 800mm, ± 1% up to 1400mm b/w detect. thresholds (6 90% rem.) 1% up to 800mm, 2% up to 1400mm Temperature compensation yes 4) Timing Measurement time 1 5 1) ms Response time 1) 15ms Delay before start-up 300ms Electrical data Operating voltage U B 18 30VDC (incl. residual ripple) Residual ripple 15% of U B Open-circuit current 150mA Switching output 2 push-pull warning outputs 5), PNP light switching, NPN dark switching, respectively Signal voltage high/low (U B -2 V)/ 2V Analogue output current 4 20mA, R L 500 Indicators teach-in on GND teach-in on +U B Green LED continuous light ready flashing fault teaching procedure no voltage Yellow LED continuous light object inside teach-in measurement distance flashing teaching procedure object outside teach-in measurement distance Mechanical data Metal housing Housing diecast zinc Optics cover glass Weight 380g Connection type M12 connector Environmental data Ambient temp. (operation/storage) -20 C +50 C / -30 C +70 C Protective circuit 6) 1, 2, 3 VDE safety class 7) II, all-insulated Protection class IP 67, IP 69K 8) LED class 1 (acc. to EN 60825-1) Standards applied IEC 60947-5-2 1) Luminosity coefficient 6% 90%, complete measurement range, at 20 C, medium range of U B, measurement object 50x50mm² 2) Minimum and maximum value depend on measurement distance 3) Same object, identical environmental conditions, measurement object 50x50mm² 4) Typ. ± 0.02 %/K 5) The push-pull switching outputs must not be connected in parallel 6) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs 7) Rating voltage 250VAC, with cover closed 8) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives. Acids and bases are not part of the test. A B C D E F Area not defined Linearity not defined Measurement range Object present No object detected Measurement distance Tables Diagrams Remarks Measurement time depends on the reflectivity of the measurement object and on the measurement mode. Coding of the warning outputs: Warning output 1 2 0 0 0 1 1 0 Meaning Distance measurement is impossible Object below measurement range (short range) Object beyond the measurement range (distant range) 1 1 Optimum function Order guide Designation Part No. With M12 connector Current output ODS 96B M/C66.01-1400-S12 501 06727 Approved purpose: The ODS 96B distance sensors are optical electronic sensors for the optical, contactless measurement of distance to objects.

Optical distance sensors Dimensioned drawing en 02-2012/11 50108384 10-30 V DC We reserve the right to make changes DS_ODS96BM66600_en_50108384.fm Reflection-independent distance information Highly insensitive to extraneous light 2 teachable switching outputs PC/OLED display and key pad for configuration Measurement value is indicated in mm on OLED display Measurement mode configurable IEC 60947... IEC 60947... Accessories: (available separately) IP 69K IP 67 Mounting systems Cable with M12 connector (K-D ) Configuration software A Indicator diode green B Indicator diode yellow C Transmitter D Receiver E Optical axis F Device plug M12x1 G Countersinking for SK nut M5, 4.2mm deep H OLED display and key pad I Reference edge for the measurement (cover glass) Electrical connection

Specifications Optical data Measurement range 1) Resolution 2) 0.1 0.5mm Hysteresis configurable, factory setting: 1mm Light source LED Wavelength 880nm (infrared light) Light spot approx. 15 x 15mm 2 at 600mm Error limits (relative to measurement distance) Absolute measurement accuracy 1) ±1.5% Repeatability 3) ±0.5% b/w detect. thresholds (6 90% rem.) 1% Temperature compensation yes 4) Timing Measurement time 1 5 1) ms Response time 1) 15ms Delay before start-up 300ms Electrical data Operating voltage U B 10 30VDC (incl. residual ripple) Residual ripple 15% of U B Open-circuit current 150mA Switching output 2 push-pull switching outputs 5), PNP light switching, NPN dark switching, respectively Signal voltage high/low (U B -2 V)/ 2V Indicators teach-in on GND teach-in on +U B Green LED continuous light ready flashing fault teaching procedure no voltage Yellow LED continuous light object inside teach-in measurement distance flashing teaching procedure object outside teach-in measurement distance Mechanical data Metal housing Housing diecast zinc Optics cover glass Weight 380g Connection type M12 connector Environmental data Ambient temp. (operation/storage) -20 C +50 C / -30 C +70 C Protective circuit 6) 1, 2, 3 VDE safety class 7) II, all-insulated Protection class IP 67, IP 69K 8) LED class 1 (acc. to EN 60825-1) Standards applied IEC 60947-5-2 1) Luminosity coefficient 6% 90%, complete measurement range, at 20 C, medium range of U B, measurement object 50x50mm² 2) Minimum and maximum value depend on measurement distance 3) Same object, identical environmental conditions, measurement object 50x50mm² 4) Typ. ± 0.02 %/K 5) The push-pull switching outputs must not be connected in parallel 6) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs 7) Rating voltage 250VAC, with cover closed 8) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives. Acids and bases are not part of the test. Switching output (example) A B C 2nd switching output 1st switching output Measurement distance Tables Diagrams Remarks Measurement time depends on the reflectivity of the measurement object and on the measurement mode. Approved purpose: The ODS 96B distance sensors are optical electronic sensors for the optical, contactless measurement of distance to objects. Order guide Designation Part No. With M12 connector 2 switching outputs ODS 96B M/66-600-S12 501 06724