Agilent OpenLAB Chromatography Data System (CDS)

Similar documents
Agilent OpenLAB Chromatography Data System (CDS)

Agilent 1260 Infinity Purification Solution

Agilent OpenLAB Chromatography Data System

Agilent OpenLAB Data Analysis Upload Download Tool. User s Guide

Agilent OpenLab CDS ChemStation Edition

Agilent OpenLAB Chromatography Data System

Agilent OpenLAB ECM Intelligent Reporter

Agilent ChemStation Plus

Agilent OpenLAB. Data Store. Backup and Restore Guide

Agilent OpenLAB Chromatography Data System (CDS)

Agilent OpenLAB Chromatography Data System (CDS)

Agilent OpenLAB Chromatography Data System (CDS)

Agilent CSV Export Utility

Secure Workstation for OpenLAB CDS ChemStation Edition User's Guide

Agilent ChemStation Plus

OpenLAB CDS ChemStation Edition

Agilent ChemStation. ECM Interface Guide. Agilent Technologies

Agilent OpenLAB. Data Store. Maintenance Guide

Agilent Lab Advisor. IT Administrator's Guide. Agilent Technologies

Agilent OpenLAB CDS Waters Alliance HPLC Instrument Control Add-On. Installation, Upgrade and Migration Guide

Agilent Dissolution Tester Driver

BenchCel Workstations Software

Agilent N2739A 1000 Series Oscilloscope Rack Mount Kit

Agilent Series Logic Analysis System

Agilent OpenLAB CDS. ChemStation Edition Instrument Configuration. Guide. Agilent Technologies

Agilent OpenLAB Data Store. Maintenance Guide

Agilent EZChrom SI. Startup Guide

Agilent ChemStation OpenLAB Option

Firmware Guide. Keysight PXIe Chassis Family

Agilent OpenLAB Data Store Administration. Guide for Administrators

OpenLAB CDS Report Template Editor

Agilent OpenLab CDS ChemStation Edition

Agilent E2094M IO Libraries

Microscan Barcode Reader

Keysight E7515A UXM Firmware Update Tool

Automated Plate Labeling

Agilent CytoGenomics 2.5

Agilent ChemStation for UV-visible Spectroscopy

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit

Agilent E2943A/E2944A ATCA Probes for Advanced Switching Interconnect

Agilent Genomic Workbench 6.0

Agilent Lab Advisor. User Manual. Agilent Technologies

Agilent OpenLAB CDS ChemStation Edition

Agilent OBSAI Protocol Tester

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit

Agilent OpenLAB CDS. Workstation Guide. Agilent Technologies. OpenLAB CDS Workstation

Agilent SureCall 3.5. Installation Guide. Agilent Technologies. For Research Use Only. Not for use in diagnostic procedures.

Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit

Agilent 89600B VSA. Software Installation Guide

Setting Up Probes. Online Help

Agilent Technologies E5385A 100-Pin Probe

Agilent G2721AA/G2733AA

Agilent MassHunter Metabolite ID Software. Installation and Getting Started Guide

G5584A Labware MiniHub

Keysight 11878A 50 Ohm 3.5 mm Adapter Kit

Agilent OpenLAB CDS. Workstation Plus (with Content Management) Agilent Technologies. OpenLAB CDS Workstation Plus

EZChrom Elite Compact. What s New in EZChrom Elite Compact Service Pack 2

Agilent OpenLAB CDS ChemStation Edition

Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit

Agilent Technologies. Connectivity Guide. USB/LAN/GPIB Interfaces. Agilent Technologies

BIT-3000 Dynamic Sequencing Generator and Analyzer. Datasheet 1.11

Agilent OpenLAB. Agilent Instrument Controller Installation and Configuration Guide

DDR/LPDDR Custom Configuration Creator Tool. User s Guide

Sample Scheduler for OpenLAB CDS EZChrom Edition. Installation & Configuration Guide. Agilent Technologies

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable

Keysight N5990A Test Automation Software Platform

Nimsoft Monitor. proxy Guide. v3.1 series

Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz

Agilent OpenLAB Chromatography Data System (CDS)

Keysight N108xA-Series IEEE Ethernet KR/CR Compliance and Debug Application

Agilent Gb/s Serial BERT

86100 Series Infiniium DCA Oscilloscope

Multiskan Ascent. Device Driver User Guide. Agilent Technologies

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

Keysight M9393A PXIe Vector Signal Analyzer

Keysight GUI Data Logger Software for U1731C, U1732C, and U1733C Handheld LCR Meter

Agilent ChemStore. Installation Guide. Agilent Technologies

Setting up a LAN Instrument Network. Installation Guide

PHERAstar. Device Driver User Guide. Agilent Technologies

Agilent Lab Advisor. User Manual. Agilent Technologies

Cavro Pump. Device Driver User Guide. Agilent Technologies

Agilent InfiniiMax II 1168A/1169A Probes

Agilent W2100 Antenna Modeling Design System

Agilent N5410A Fibre Channel Automated Test Application

Agilent 7890 Series Gas Chromatograph

Agilent ChemStation for GC Systems

Agilent Protocol Analyzer and Jammer for USB. Quick Start Guide

Agilent 1290 Infinity with ISET

MSD SECTOR Reader. Device Driver User Guide. Agilent Technologies

Agilent ChemStore C/S. Concepts Guide

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies

Automated Serial Dilution

Automated Plate Centrifugation

Agilent OpenLAB Chromatography Data System (CDS)

U85026A Detector 40 to 60 GHz

Agilent ChemStore C/S. Concepts Guide

Agilent Genomic Workbench 7.0

Agilent MassHunter Drug Analysis Mode Using Quantitative Analysis Workflow Guide

Nimsoft Monitor. cluster Guide. v2.6 series

Agilent Triple Quadrupole LC/MS Peptide Quantitation with Skyline

Transcription:

Agilent OpenLAB Chromatography Data System (CDS) ChemStation Edition Reusing Data from ChemStation B.04.03 SP1 and SP2 in OpenLAB CDS ChemStation Edition

Notices Agilent Technologies, Inc. 2012-2013, 2014 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Agilent Technologies, Inc. as governed by United States and international copyright laws. Manual Part Number M8301-90162 Edition 09/2014 Agilent Technologies Hewlett-Packard-Strasse 8 76337 Waldbronn Software Revision This guide is valid for Agilent OpenLAB CDS ChemStation Edition C.01.07. This product may be used as a component of an in vitro diagnostic system if the system is registered with the appropriate authorities and complies with the relevant regulations. Otherwise, it is intended only for general laboratory use. Warranty The material contained in this document is provided as is, and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Agilent shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein. Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the separate agreement shall control. Technology Licenses The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license. Restricted Rights Legend If software is for use in the performance of a U.S. Government prime contract or subcontract, Software is delivered and licensed as Commercial computer software as defined in DFAR 252.227-7014 (June 1995), or as a commercial item as defined in FAR 2.101(a) or as Restricted computer software as defined in FAR 52.227-19 (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is subject to Agilent Technologies standard commercial license terms, and non-dod Departments and Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR 52.227-19(c)(1-2) (June 1987). U.S. Government users will receive no greater than Limited Rights as defined in FAR 52.227-14 (June 1987) or DFAR 252.227-7015 (b)(2) (November 1995), as applicable in any technical data. Safety Notices CAUTION A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. WARNING A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.

Contents 1 Reusing Your Data in OpenLAB CDS ChemStation Edition with OpenLAB Data Store or OpenLAB ECM Sequence Data Stored in Result Sets 5 Transferring ChemStation Data to OpenLAB Data Store or OpenLAB ECM 6 Requirements 6 Step 1 Verify Containers are in Use. 6 Step 2 Create a Result Set for Results that are not in a Container. 7 Step 3 Manually Transfer Data Into OpenLAB Data Store or OpenLAB ECM. 10 2 Reusing Your Data in a Standalone Open LAB CDS ChemStation Edition System Steps to Migrate 13 Facts to Know for Data Migration 15 Compatibility of ChemStation Entities 15 Migration of Reporting Templates 15 Migration of Classic Methods to RC.net Methods 15 Estimated Time to Upgrade 15 List of Detailed Documents to Reference 16 Reusing B.04.03 ChemStation Data in OpenLAB CDS 3

Agilent OpenLAB Chromatography Data System (CDS) Reusing ChemStation Data 1 Reusing Your Data in OpenLAB CDS ChemStation Edition with OpenLAB Data Store or OpenLAB ECM Sequence Data Stored in Result Sets 5 Transferring ChemStation Data to OpenLAB Data Store or OpenLAB ECM 6 This chapter describes a manual procedure for transferring ChemStation Sequences that were stored in containers (now called result sets), from a ChemStation file system into OpenLAB CDS ChemStation Edition with Data Store or ECM. NOTE These instructions support the transfer of data from ChemStation B.04.03 SP1 to OpenLAB CDS ChemStation C.01.04 or higher. During an upgrade project there might be different versions of OpenLAB CDS in your environment. Please note that the analysis and reprocessing of data is supported only on versions same as or higher than the one used for the acquisition or last reprocessing. Agilent recommends that a mixed version system should be used only during the upgrade phase. For more information, please refer to the OpenLAB CDS Administration Guide (CDS_Admin.pdf on Disk 1). Agilent Technologies 4

Reusing Your Data in OpenLAB CDS ChemStation Edition with OpenLAB Data Store or OpenLAB ECM Sequence Data Stored in Result Sets In order to strengthen the association between data files and methods, the usage of result sets has been introduced with ChemStation B.02.01 (result sets have been called sequence containers then). If you use a central data storage system (OpenLAB ECM or OpenLAB Data Store), the complete result set (sequence/methods/data files/report templates) is transferred to the central repository as one entity. Figure 1 Sequence Acquisition with Unique Folder Creation ON The methods in the folder Chem32\1\methods serve as master methods. They remain unchanged during acquisition and data analysis. Similarly, the sequences in the folder Chem32\1\sequence serve as sequence templates that can be used to rerun (but not reprocess) a sequence several times. NOTE Report Templates in the folder Chem32\repstyle serve as a starting point for developing your own report templates. If your data is not in this format, Agilent recommends changing your configuration now, to be ready to migrate easily in the future. See Step 1 Verify Containers are in Use. on page 6, for more details on this. 5 Reusing B.04.03 ChemStation Data in OpenLAB CDS

Reusing Your Data in OpenLAB CDS ChemStation Edition with OpenLAB Data Store or OpenLAB ECM Transferring ChemStation Data to OpenLAB Data Store or OpenLAB ECM Requirements The user who will carry out this transfer must be part of the Local Administrator group. The user should have administrative privileges in ChemStation and in OpenLAB Shared Services (the Everything privilege in OpenLAB Control Panel) so he can edit the method and sequence data path, select the ECM or Data Store path in the transfer settings, and create and configure instruments in OpenLAB Shared Services. The data to be transferred must be stored in containers (result sets). Step 1 Verify Containers are in Use. Only data stored in a container (result set) will transfer to Data Store or ECM. NOTE Before continuing, verify that the data being transferred is in a container. Data in containers will look similar to the screen capture below. Notice that all the data files, the sequence file, and the methods used in the sequence are grouped in a single folder. This folder, known as the container in ChemStation B.04.03, is now called the result set. If you see the data is not in this format, Agilent recommends changing your configuration now, to be ready to migrate easily in the future. For old data that is not in a container, create one as described in step 2. Result Set for the sequence named My Sequence Reusing B.04.03 ChemStation Data in OpenLAB CDS 6

Reusing Your Data in OpenLAB CDS ChemStation Edition with OpenLAB Data Store or OpenLAB ECM For more details on ChemStation data Structure please refer to the OpenLAB CDS ChemStation Edition Concepts and Workflows guide (M8301-90016). Step 2 Create a Result Set for Results that are not in a Container. Use the Result Set Migration screen in ChemStation to make containers (result sets) for the data to be uploaded to Data Store or ECM. NOTE Only use this procedure if you are certain about the sequence and method that was used to produce the data. 1 From the Data Analysis view of the OpenLAB ChemStation, select Sequence > Result Set Migration to open the Result Set Migration dialog. 2 Navigate to, and select the sequence template from the ChemStation B.04.03 backup data acquired for that instrument folder. If you do not know which sequence was used, please refer to *.log in data folder. This figure highlights the log file (Test3.log) in the Test3 data folder: 7 Reusing B.04.03 ChemStation Data in OpenLAB CDS

Reusing Your Data in OpenLAB CDS ChemStation Edition with OpenLAB Data Store or OpenLAB ECM This figure shows the Test3.log file opened in Notepad, with the name of the sequence file highlighted: Test3.LOG Sequence used 3 Select the Method folder from the ChemStation B.04.03 backup location. 4 Select the source folder from the ChemStation B.04.03 backup location. Reusing B.04.03 ChemStation Data in OpenLAB CDS 8

Reusing Your Data in OpenLAB CDS ChemStation Edition with OpenLAB Data Store or OpenLAB ECM 5 Select the destination folder. Create a new subfolder within the data folder structure of the upgraded location and select it as the destination. 6 Click Start. 7 If the result set migration was successful, an appropriate message will be displayed as highlighted in the figure below. For more information on result sets refer to ChemStation documentation. 9 Reusing B.04.03 ChemStation Data in OpenLAB CDS

Reusing Your Data in OpenLAB CDS ChemStation Edition with OpenLAB Data Store or OpenLAB ECM Step 3 Manually Transfer Data Into OpenLAB Data Store or OpenLAB ECM. 1 Setup a client PC with a Data Store or ECM connection. NOTE For ECM, please refer to the ECM Installation Guide. For Data Store, please refer to the Data Store Installation Guide. 2 Create folders for your data, methods, and sequences in Data Store or ECM. 3 In the ChemStation Method and Run Control view, browse to Data Store or ECM > Preferences. In the Preferences dialog: a Click the Paths tab and enter the paths for Sequence, Data, and Methods that were used with the ChemStation file system. b Click the Transfer Settings tab and select the Import After Reprocessing check box. Verify that the data transfer path is set to the correct path. If the Import After Reprocessing check box is cleared and grayed out in the Preferences, this option needs to be enabled for the entire workstation in the ChemStation Administration Tool. This tool is accessible to administrators (under Start Menu > Programs > Agilent Technologies> OpenLAB CDS ChemStation Edition). Add Methods from a ChemStation File System to Data Store or ECM 1 From ChemStation Explorer, in the Method and Run Control view, click the Methods tab and then double- click a method to load it. 2 Click Data Store or ECM > Save Method. 3 Browse to a folder created in Data Store or ECM and save the method. 4 The method icon in the ChemStation Navigation Pane will change from to indicating that the method has been saved to Data Store or ECM. 5 If the instrument configuration of the method being saved does not match the current instrument configuration, the configuration may need to be resolved prior to saving. Reusing B.04.03 ChemStation Data in OpenLAB CDS 10

Reusing Your Data in OpenLAB CDS ChemStation Edition with OpenLAB Data Store or OpenLAB ECM Add Sequence Templates from a ChemStation File System to Data Store or ECM 1 From ChemStation Explorer, in the Method and Run Control view, click the Sequence Templates tab and then double- click a sequence template to load it. 2 Click Data Store or ECM > Save Sequence Template. 3 Browse to a folder created in Data Store or ECM and save the sequence template. 4 The icon for the sequence template will change from to indicating the sequence template has been saved to Data Store or ECM. Add Data from a ChemStation File System to a Data Store or ECM System NOTE For this way of importing data, the Import After Reprocessing check box must be selected in the Preferences > Transfer Settings dialog or in the ChemStation Administration Tool. 1 From ChemStation Explorer, in the Data Analysis view, click the Data tab. 2 Double- click data that you want to add to Data Store or ECM. Please note that only data stored in a container or result set will be transferred. 3 Reprocess the data by choosing the Reprocessing Mode and clicking (Start Sequence Reprocessing) in the sequence reprocessing toolset. 4 Data from the file system will appear in Data Store or ECM. The sequence icon in the ChemStation Navigation Pane will change from to indicating that the sequence has been saved to Data Store or ECM. Add Other Files from a ChemStation File System to a Data Store or ECM System 1 In the Method and Run Control view or in the Data Analysis view, Click Data Store or ECM > Upload Files. 2 In the Upload file dialog, select the file to upload and the target folder in Data Store or ECM. You can add UV- libraries (*.uvl), column databases (*.mdb), Easy Sequence templates (*.est) or classic report templates (*.frp). 11 Reusing B.04.03 ChemStation Data in OpenLAB CDS

Agilent OpenLAB Chromatography Data System (CDS) Reusing ChemStation Data 2 Reusing Your Data in a Standalone Open LAB CDS ChemStation Edition System Steps to Migrate 13 Facts to Know for Data Migration 15 Estimated Time to Upgrade 15 List of Detailed Documents to Reference 16 This chapter describes how to move methods, sequence and data files from a standalone ChemStation Workstation, version B.04.03 SP1 and SP2, to an OpenLAB CDS ChemStation Edition Workstation when the data is stored in the container mode. Also included in this chapter is a list of documents that contain more details on reusing data. Agilent Technologies 12

Reusing Your Data in a Standalone Open LAB CDS ChemStation Edition System Steps to Migrate 1 Manually backup data acquired for all ChemStation B.04.03 SP1 instruments. 2 Run the Configuration Editor and record the following details of each configured instrument. You need these details to reconfigure your instruments in OpenLAB CDS ChemStation Edition. a Instrument number b Instrument name c Instrument type d Connection settings (for example, IP address or GPIB address) 3 Uninstall all Add- On Solutions. Refer to the Add- On Solution manual for specific uninstallation instructions. 4 Install OpenLAB CDS ChemStation Edition. During the installation, the Master Installer either uninstalls the previous ChemStation or moves it to a different folder before installing OpenLAB CDS ChemStation Edition. If you choose to keep the existing ChemStation folder, the installed ChemStation files are removed, and all user- created files are moved to a backup folder, for example, Chem32_001. If you choose to create a new folder, the existing folder is retained with its original name. 5 To move data which was previously saved in a container mode, add the path from the ChemStation B.04.03 version to the new directory/machine by using the Preferences > Path > Add function. a In the Data Analysis view, select View > Preferences to open the Preferences dialog box. b Click the Paths tab. c Press Add and navigate to the location of the sequence templates, data, and master methods, that were created by the ChemStation B.04.03 system. (This could be from the backup folder of the ChemStation B.04.03 system, which was prepared before upgrading, or the backup folder Chem32_001 generated by the Master Installer.) 13 Reusing B.04.03 ChemStation Data in OpenLAB CDS

Reusing Your Data in a Standalone Open LAB CDS ChemStation Edition System d Click OK. The selected paths and all the sequence templates, data, and master methods stored in them are now displayed in the ChemStation Explorer. 6 Double- click each sequence, one at a time, to load the associated data files into ChemStation memory, then click the Start Reprocessing icon to reprocess the data and generate a ChemStation result set. Please see the Checksum.ini and Sequence.acaml file for the time stamp to confirm that the data was reprocessed. Start Reprocessing icon Path identified in step 5 Reusing B.04.03 ChemStation Data in OpenLAB CDS 14

Reusing Your Data in a Standalone Open LAB CDS ChemStation Edition System Facts to Know for Data Migration Compatibility of ChemStation Entities In general, forward compatibility is guaranteed. This means that it is possible to load methods, sequence templates and data from previous versions in newer versions. This is especially true for loading files from any ChemStation rev. B.xx.xx version into OpenLAB CDS ChemStation Edition rev. C.xx.xx. But there is no backward compatibility. Once a method or sequence template has been stored in OpenLAB CDS ChemStation Edition rev. C.xx.xx, it can no longer be used in a ChemStation rev. B.xx.xx. The same is true for data. Loading data files from OpenLAB CDS ChemStation Edition rev. C.xx.xx in ChemStation rev. B.xx.xx is not supported and could lead to serious issues with the data files creating wrong or incomplete results. Therefore Agilent recommends clearly separating ChemStation rev. B.xx.xx files from OpenLAB CDS ChemStation Edition rev. C.xx.xx files within ECM to make sure that files are not loaded in an older version by accident. Migration of Reporting Templates Currently there is no migration for old FRP report templates to the new RDL report template format. Old FRP templates will continue to work in OpenLAB CDS ChemStation Edition rev. C.xx.xx, but new RDL templates have to be created from scratch. Migration of Classic Methods to RC.net Methods Estimated Time to Upgrade RC.net methods were introduced in ChemStation rev. B.04.02. The method migration (migrating classic methods to RC.net methods) will still work the same way in OpenLAB CDS ChemStation Edition rev. C.xx.xx. An RC.net method cannot be converted back to a classic method. The estimated time to upgrade from ChemStation B.04.03 SP1 to OpenLAB CDS ChemStation Edition rev. C.xx.xx is approximately 30 minutes for software upgrade. 15 Reusing B.04.03 ChemStation Data in OpenLAB CDS

Reusing Your Data in a Standalone Open LAB CDS ChemStation Edition System List of Detailed Documents to Reference 1 Overview of Upgrade procedures: Please refer to the chapter Overview of the Upgrade Procedure in the OpenLAB CDS ChemStation Edition Upgrade Preparation Guide, (M8301-90033, CDS_CS-Upgrade.pdf on disc 2) 2 Result Set Migration and more details on ChemStation data structure: Please refer to the chapters Result Set Migration and ChemStation Data Structure in the OpenLAB CDS ChemStation Edition Concepts and Workflows Guide (M8301-90016, CDS_CS_Concepts.pdf on disc 2) 3 Upload and reprocess workflows: Please refer to the chapter Working with ChemStation and Central Data Storage in the OpenLAB CDS ChemStation Edition with Central Data Storage User's Guide (M8301-90084, CDS_CS-with-DataStorage.pdf on disc 2) Reusing B.04.03 ChemStation Data in OpenLAB CDS 16

Agilent Technologies Agilent Technologies Printed in Germany, September 2014 *M8301-90162* M8301-90162