ATV212HD30N4 variable speed drive ATV212-30kW - 40hp - 480V - 3ph - EMC - IP21

Similar documents
ATV212HD18N4 variable speed drive ATV kW - 25hp - 480V - 3ph - EMC - IP21

ATV212HD11N4 variable speed drive ATV212-11kW - 15hp - 480V - 3ph - EMC - IP21

ATV212WU40N4 variable speed drive ATV212-4kW - 5hp - 480V - 3ph - EMC class C2 - IP55

ATV212HD15N4 variable speed drive ATV212-15kW - 20hp - 480V - 3ph - EMC - IP21

ATV212WU55N4 variable speed drive ATV kW - 7.5hp - 480V - 3ph - EMC class C2 - IP55

ATV212HD15N4 variable speed drive ATV212-15kW - 20hp - 480V - 3ph - EMC - IP21

ATV212WD30N4 variable speed drive ATV212-30kW - 40hp - 480V - 3ph - EMC class C2 - IP55

ATV212HU55N4 variable speed drive ATV kW - 7.5hp - 480V - 3ph - EMC - IP21

ATV212HD75N4. Main. Range of product Altivar 212. Device short name. Motor power hp 160 A 460 V khz with derating factor

ATV212HU55N4 variable speed drive ATV kW - 7.5hp - 480V - 3ph - EMC - IP21

ATV212HU15N4. Main. Range of product Altivar 212. Device short name 3.7 A 460 V khz adjustable

ATV212HD11M3X variable speed drive ATV212-11kW - 15hp - 240V - 3ph -wo EMC - IP21

ATV212HU75N4 variable speed drive ATV kW - 10hp - 480V - 3ph - EMC - IP21

ATV212HD30N4 variable speed drive ATV212-30kW - 40hp - 480V - 3ph - EMC - IP21

ATV212HD22N4 variable speed drive ATV212-22kW - 30hp - 480V - 3ph - EMC - IP21

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV61HC11N4 SPEED DRIVE 150 HP 460 V ATV61

ATV61HU55M3 ATV61 5,5 kw 7,5HP 240V single phase EMC IP20

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV320U06N4C variable speed drive ATV kW V - 3 phase - compact

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATV61QC31N4 variable speed drive ATV61Q - 315kW / 500HP V - IP20

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATV32H055N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320U30N4B variable speed drive ATV320-3kW V - 3 phase - book

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

ATV71QC16N4 variable speed drive ATV71Q - 160kW / 250HP V - IP20

ATV61HC31N4 variable speed drive ATV61-315kW 500HP - 500V - EMC filter - IP20

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV32HU40N4 variable speed drive ATV32-4 kw V - 3 phase - with heat sink

ATV61HC22N4 Altivar 61 drive 350hp 400/480 3ph

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

ATV32H018M2 variable speed drive ATV32-0,18 kw V - 1 phase - with heat sink

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

ATV340D18N4E variable speed drive - 18kW- 400V - 3 phases - ATV340 Ethernet

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATV71EXA2C71N4 enclosed variable speed drive ATV71 Plus kw - 400V - IP23

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATV61HD11Y variable speed drive ATV61-11kW / 690V - 10HP / 575V - IP20

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ATV630D11N4 variable speed drive ATV630-11kW/15HP V - IP21/UL type 1

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

ATV630D15N4 variable speed drive ATV630-15kW/20HP V - IP21/UL type 1

ATV650D22N4 variable speed drive ATV650-22kW/30HP V - IP55

ATV630D90N4 variable speed drive ATV630-90kW/125HP V - IP21/UL type 1

ATV930U07M3 variable speed drive - ATV930-0,75kW - 200/240V- with braking unit - IP21

ATV61HC22N4 Altivar 61 drive 350hp 400/480 3ph

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV61HU30N4 SPEED DRIVE, 4HP,460V,ATV61

ATV61HC22N4 variable speed drive ATV61-220kW 350HP - 500V - EMC filter - IP20

ATV61HC16N4 variable speed drive ATV61-160kW 250HP V - IP20

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ATV61HC80Y variable speed drive ATV61-800kW / 690V - 800HP / 575V - IP20

ATV61HU15N4 variable speed drive ATV61-1.5kW 2HP V - IP20

ATV320U15N4C. Product datasheet Characteristics. Main. Complementary 1 / 7. Device short name Format of the drive

ATV320U11N4C. Product datasheet Characteristics. Main. Complementary 1 / 7. Device short name Format of the drive

ATV320U22M2C. Product datasheet Characteristics. Main. Complementary 1 / 7. Device short name Format of the drive

ATV61HD75N4 variable speed drive ATV61-75kW 100HP V - IP20

ATV71HC31N4 variable speed drive ATV71-315kW-500HP - 480V - EMC filter-graphic terminal

ATV320D11N4B. Product datasheet Characteristics. Main. Complementary 1 / 8. Device short name Format of the drive

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

ATV61WD18N4C variable speed drive ATV kW 25HP V - EMC filter - IP54

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

ATV71HC11Y variable speed drive ATV71-110kW - 690V - EMC filter-graphic terminal

LXM32AD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

ATV71HD18N4 variable speed drive ATV kW-25HP - 480V - EMC filter-graphic terminal

ATV320D15M3C variable speed drive ATV320-15kW - 200V - 3phase - compact

ATV71HD30N4Z variable speed drive ATV71-30kW-40HP - 480V - EMC filter-w/o graphic terminal

250 kw at V 3 phases. 400 hp at V 3 phases

ATV71HC28N4D variable speed drive ATV71-280kW-450HP - 480V - EMC filter-graphic terminal

ATV71HU22N4Z variable speed drive ATV71-2.2kW-3HP - 480V - EMC filter-w/o graphic terminal

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATV71HD37M3X variable speed drive ATV71-37kW-50HP - 240V - w/o EMC filter-graphic terminal

Transcription:

Product datasheet Characteristics ATV212HD30N4 variable speed drive ATV212-30kW - 40hp - 480V - 3ph - EMC - IP21 Complementary Apparent power Prospective line Isc Continuous output current Maximum transient current Speed drive output frequency Nominal switching frequency Switching frequency Main Range of product Altivar 212 Product or component type Device short name Product destination Product specific application Assembly style Network number of phases Motor power kw Motor power hp Variable speed drive ATV212 Asynchronous motors Pumps and fans in HVAC With heat sink 3 phases 30 kw 40 hp [Us] rated supply voltage 380...480 V - 15...10 % Supply voltage limits 323...528 V Supply frequency 50...60 Hz - 5...5 % Network frequency EMC filter Line current 44.6 kva 380 V 22 ka 58.5 A 380 V 58.5 A 460 V 64.4 A 60 s 0.5...200 Hz 8 khz Speed range 1...10 Speed accuracy Torque accuracy +/- 15 % Transient overtorque Asynchronous motor control profile Regulation loop Motor slip compensation Local signalling Output voltage Isolation Type of cable Electrical connection Tightening torque 6...16 khz adjustable 8...16 khz with derating factor +/- 10 % of nominal slip 0.2 Tn to Tn 47.5...63 Hz Class C2 EMC filter integrated 44.7 A 480 V 56.7 A 380 V 120 % of nominal motor torque +/- 10 % 60 s Voltage/frequency ratio, 2 points Voltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Adjustable PI regulator Adjustable Automatic whatever the load Not available in voltage/frequency ratio motor control 1 LED red DC bus energized <= power supply voltage Electrical between power and control IEC cable without mounting kit 1 45 C copper 90 C XLPE/EPR IEC cable without mounting kit 1 45 C copper 70 C PVC UL 508 cable with UL Type 1 kit 3 40 C copper 75 C PVC Terminal 2.5 mm² AWG 14 VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES Terminal 50 mm² AWG 1/0 L1/R, L2/S, L3/T 24 N.m 212 lb.in L1/R, L2/S, L3/T The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. 1 / 9

Supply Analogue input number 2 Analogue input type Sampling duration Response time 0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES Internal supply for reference potentiometer (1 to 10 kohm) 10.5 V DC +/- 5 % <= 10 A overload and short-circuit protection Internal supply 24 V DC 21...27 V <= 200 A overload and short-circuit protection Switch-configurable voltage VIA 0...10 V DC 24 V max 30000 Ohm 10 bits Configurable voltage VIB 0...10 V DC 24 V max 30000 Ohm 10 bits Configurable PTC probe VIB 0...6 probes 1500 Ohm Switch-configurable current VIA 0...20 ma 250 Ohm 10 bits 2 ms +/- 0.5 ms F discrete 2 ms +/- 0.5 ms R discrete 2 ms +/- 0.5 ms RES discrete 3.5 ms +/- 0.5 ms VIA analog 22 ms +/- 0.5 ms VIB analog 2 ms +/- 0.5 ms FM analog 7 ms +/- 0.5 ms FLA, FLC discrete 7 ms +/- 0.5 ms FLB, FLC discrete 7 ms +/- 0.5 ms RY, RC discrete Accuracy +/- 0.6 % VIA for a temperature variation 60 C +/- 0.6 % VIB for a temperature variation 60 C +/- 1 % FM for a temperature variation 60 C Linearity error Analogue output number 1 Analogue output type Discrete output number 2 Discrete output type Minimum switching current Maximum switching current Discrete input type Discrete input logic Acceleration and deceleration ramps Braking to standstill Protection type Dielectric strength Insulation resistance Frequency resolution Communication port protocol Connector type +/- 0.15 % of maximum value input VIA +/- 0.15 % of maximum value input VIB +/- 0.2 % output FM Switch-configurable voltage FM 0...10 V DC 7620 Ohm 10 bits Switch-configurable current FM 0...20 ma 970 Ohm 10 bits Configurable relay logic FLA, FLC NO 100000 cycles Configurable relay logic FLB, FLC NC 100000 cycles Configurable relay logic RY, RC NO 100000 cycles 3 ma 24 V DC configurable relay logic 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R Programmable F 24 V DC level 1 PLC 4700 Ohm Programmable R 24 V DC level 1 PLC 4700 Ohm Programmable RES 24 V DC level 1 PLC 4700 Ohm Positive logic (source) F, R, RES <= 5 V >= 11 V Negative logic (sink) F, R, RES >= 16 V <= 10 V Automatic based on the load Linear adjustable separately from 0.01 to 3200 s By DC injection Input phase breaks drive Line supply overvoltage and undervoltage drive Line supply undervoltage drive Overcurrent between output phases and earth drive Overheating protection drive Short-circuit between motor phases drive Thermal protection motor Motor phase break motor Break on the control circuit drive Thermal power stage drive Overvoltages on the DC bus drive Against exceeding limit speed drive Against input phase loss drive With PTC probes motor 3535 V DC between earth and power terminals 5092 V DC between control and power terminals >= 1 MOhm 500 V DC for 1 minute 0.1 Hz display unit 0.024/50 Hz analog input APOGEE FLN BACnet LonWorks METASYS N2 Modbus 1 RJ45 2 / 9

1 open style Physical interface 2-wire RS 485 Transmission frame Transmission rate Data format Type of polarization RTU Number of addresses 1...247 Communication service Option card Operating position Width Height Depth Product weight Power dissipation in W Air flow Functionality Specific application IP degree of protection Discrete and process manufacturing Power range Motor starter type 9600 bps or 19200 bps 8 bits, 1 stop, odd even or no configurable parity No impedance Monitoring inhibitable Read device identification (43) Read holding registers (03) 2 words maximum Time out setting from 0.1 to 100 s Write multiple registers (16) 2 words maximum Write single register (06) Communication card LonWorks Vertical +/- 10 degree 240 mm 420 mm 214 mm 26.4 kg 847 W 290 m3/h Mid HVAC IP21 Building - HVAC : compressor for scroll Building - HVAC : fan Building - HVAC : pump 30...50 kw at 380...440 V 3 phases 30...50 kw at 480...500 V 3 phases Variable speed drive Environment electromagnetic compatibility 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 Electrical fast transient/burst immunity test level 4 IEC 61000-4-4 Electrostatic discharge immunity test level 3 IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 Conducted radio-frequency immunity test level 3 IEC 61000-4-6 Voltage dips and interruptions immunity test IEC 61000-4-11 pollution degree 3 IEC 61800-5-1 IP degree of protection IP20 on upper part without blanking plate on cover EN/IEC 61800-5-1 IP20 on upper part without blanking plate on cover EN/IEC 60529 IP21 EN/IEC 61800-5-1 IP21 EN/IEC 60529 IP41 on upper part EN/IEC 61800-5-1 IP41 on upper part EN/IEC 60529 vibration resistance 1.5 mm 3...13 Hz EN/IEC 60068-2-6 1 gn 13...200 Hz EN/IEC 60068-2-8 shock resistance 15 gn 11 ms IEC 60068-2-27 environmental characteristic Classes 3C1 IEC 60721-3-3 Classes 3S2 IEC 60721-3-3 noise level operating altitude 59.9 db 86/188/EEC <= 1000 m without derating 1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m relative humidity 5...95 % without condensation IEC 60068-2-3 5...95 % without dripping water IEC 60068-2-3 ambient air temperature for operation ambient air temperature for storage -25...70 C -10...40 C without derating > 40...50 C with derating factor standards EN 55011 class A group 1 EN 61800-3 EN 61800-3 category C2 EN 61800-3 category C3 3 / 9

product certifications marking EN 61800-3 environments 1 category C1 EN 61800-3 environments 1 category C2 EN 61800-3 environments 1 category C3 EN 61800-3 environments 2 category C1 EN 61800-3 environments 2 category C2 EN 61800-3 environments 2 category C3 EN 61800-5-1 IEC 61800-3 IEC 61800-3 category C2 IEC 61800-3 category C3 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C1 IEC 61800-3 environments 2 category C2 IEC 61800-3 environments 2 category C3 IEC 61800-5-1 UL Type 1 CSA C-Tick NOM 117 UL CE Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Green Premium product Compliant - since 1050 - Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Available Available Contractual warranty Warranty period 18 months Dimensions Dimensions in mm ATV212H a b c G H K Ø D22M3X D22N4, D30N4 240 420 214 206 403 10 6 D37N4, D45N4 240 550 244 206 529 10 6 Dimensions in in. ATV212H a b c G H K Ø D22M3X D22N4, D30N4 9.45 16.54 8.43 8.11 15.87 0.39 0.24 D37N4, D45N4 9.45 21.65 9.60 8.11 20.83 0.39 0.24 EMC mounting plate (supplied with drive) 4 / 9

Dimensions in mm ATV212H b1 c1 D22M3X D22N4, D30N4 122 120 D37N4, D45N4 113 127 Dimensions in in. ATV212H b1 c1 D22M3X D22N4, D30N4 4.80 4.72 D37N4, D45N4 4.45 5.00 Mounting Recommendations Clearance Depending on the conditions in which the drive is to be used, its installation will require certain precautions and the use of appropriate accessories. Install the unit vertically: Do not place it close to heating elements. Leave sufficient free space to ensure that the air required for cooling purposes can circulate from bottom to the top of the unit. Mounting Types Type A mounting Type B mounting Type C mounting 5 / 9

By removing the protective blanking cover from the top of the drive, the degree of protection for the drive becomes IP21. The protective blanking cover may vary according to the drive model, see opposite. Specific Recommendations for Mounting in an Enclosure To help ensure proper air circulation in the drive: Fit ventilation grilles. Check that there is sufficient ventilation. If there is not, install a forced ventilation unit with a filter. The openings and/or fans must provide a flow rate at least equal to that of the drive fans (refer to the product characteristics). Use special filters with UL Type 12/IP54 protection. Remove the blanking cover from the top of the drive. Sealed Metal Enclosure (IP54 Degree of Protection) The drive must be mounted in a dust and damp proof enclosure in certain environmental conditions, such as dust, corrosive gases, high humidity with risk of condensation and dripping water, splashing liquid, etc.this enables the drive to be used in an enclosure where the maximum internal temperature reaches 50 C. Recommended Wiring Diagram 3-Phase Power Supply A1: ATV 212 drive KM1:Contactor Q1: Circuit breaker Q2: GV2 L rated at twice the nominal primary current of T1 Q3: GB2CB05 S1, S2: XB4 B or XB5 A pushbuttons T1: 100 VA transformer 220 V secondary (1) Fault relay contacts for remote signalling of the drive status (2) Connection of the common for the logic inputs depends on the positioning of the switch (Source, PLC, Sink) (3) Reference potentiometer SZ1RV1202 All terminals are located at the bottom of the drive. Install interference suppressors on all inductive circuits near the drive or connected 6 / 9

on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc. Switches (Factory Settings) Voltage/current selection for analog I/O (VIA and VIB) Voltage/current selection for analog I/O (FM) Selection of logic type (1) negative logic (2) positive logic Other Possible Wiring Diagrams Logic Inputs According to the Position of the Logic Type Switch Source position Sink position PLC position with PLC transistor outputs (1) PLC (1) PLC 2-wire control F: Forward R: Preset speed 3-wire control F: Forward R: Stop RES:Reverse PTC probe 7 / 9

(3) Motor Analog Inputs Voltage analog inputs External +10 V (4) Speed reference potentiometer 2.2 to 10 kω Analog input configured for current: 0-20 ma, 4-20 ma, X-Y ma (5) Source 0-20 ma, 4-20 ma, X-Y ma Analog input VIA configured as positive logic input ( Source position) Analog input VIA configured as negative logic input ( Sink position) Derating Curves The derating curves for the drive nominal current (In) depend on the temperature, the switching frequency and the mounting type (A, B or C). For intermediate temperatures (45 C for example), interpolate between 2 curves. 8 / 9

X Switching frequency Our Proposal: Circuit Breaker + Contactor + Drive for Motor Power 30 kw and 380 VAC Motor Power (kw) Icu (ka) Breaker Contactor (*) Motor Starter 30 50 Non contractual pictures. GV3L65 LC1D40AP7 ATV212HD30N4 (*) You can select the contactor proposed or variants. Please consider examples hereafter or follow the link to the complete offer. Motor Power kw Coil voltage VAC - 50/60 Hz 24 48 110 115 220 230 400 Other 30 LC1D40A.. B7 E7 F7 FE7 M7 P7 V7 Complete Offer Motor Power kw Coil voltage VDC - U 0.75 1.25 Uc 24 48 Other 30 LC1D40A.. BD ED Complete Offer 9 / 9