Ground Monitoring Device Series 8485

Similar documents
Grounding Monitoring Device Series 8485

Grounding Monitoring Device Series 8485

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Micro Limit Switch Series 8064

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

Linear Luminaire with LED Series 6012/5

Control Switches for Panel Mounting Series 8003

Linear Luminaire with LED Series 6412/5

Terminal Boxes Series 8118

Position Switches Series 8070

Tubular Light Fitting with LED Series 6036

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Control Buttons / Switches for Panel Mounting Series 8003

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Miniature Circuit-Breaker IEC Series 8562

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Load Disconnect Switches and Motor Switches

CPU module for zone 2 Series 9442/35

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

5 Fieldbus Technology

PI-EX-ME-2NAM/COC-24VDC

Cable End Boxes Series 8146

PI-EX-ME-2NAM/COC-120VAC

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

PHOENIX CONTACT - 12/2007

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Reed sensor For bypass level indicators Model BLR

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Installation Equipments

DR7100 SERIES Supplementary instructions

Threaded resistance thermometer Miniature design Model TR10-D

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Resistance thermometer With spring-loaded tip Model TR55

Continuous level measurement Radar transmitters

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

Operating and monitoring systems Thin Client SERIES 500 Device platform EAGLE PM ET-556-TX

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX

PHOENIX CONTACT - 01/2008

Overfill Prevention Controller EUS-2

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30

Capacitance level switches LS 210 LS 220

2.3. Ex-Linear light fittings for fluorescent lamps. ellk W 58 W / ellm W 36 W (Zone 1, 2, 21, 22)

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM ET-436-TX

Operating Instructions

GRP Flameproof Visual Signal Xenon or Steady LED

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

FLEX Ex Spring Clamp Terminal Base

ATX JBEA and ECEA Series Aluminum Enclosures Increased Safety

Loads and Motor Switchgears

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

RT2Y Compact temperature switch intrinsic safety

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Absolute Rotary Encoder EXAG Explosion Proof. Profibus-DP

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE PM MT-336-FX

8WH5 Combination Plug-In Terminals

Gas-actuated thermometer Stainless steel version Model 73

Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Flow Measurement SITRANS F C

Float switch For the process industry, lateral installation with external chamber Model ELS

Technical Information Promonitor NRF560

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Magnetic float switch For vertical installation Model FLS

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

Threaded thermocouple Miniature design Model TC10-D

SMARTLINE RM76 Supplementary instructions

Product manual plug, sockets and coupler 16 A.- Z0251

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Technical Data. General specifications. Rated operating distance s n 3 mm

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Standard enclosure for Remote I/O Series 8150

PowerDRIVE-Box GEL 6505 Interface for controlling up to 5 positioning drives

2900 Float & Tape Transmitter

Continuous level measuring system NB 3000 Selection list

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

2910 Float & Tape Transmitter

Ultrasonic level meters ULM 53

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Features. Sensing range 50 mm mm... Type of light. Light source 3) Wave length. Adjustment 2) PL80A.

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Micro Motion, Inc. Page 1 of 6

ATX MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

Inductive sensor with analog output BI15-M30-LI-EXI

Safety switches with separate actuator

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

Level Measurement. Continuous level measurement - Ultrasonic controllers. SITRANS LU01 and LU02. 5/156 Siemens FI Overview.

FOR LIQUIDS AND SOLIDS

SolConeX extra-low voltage flange socket

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Transcription:

www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with road tankers) > Water jet protected aluminium enclosure IP65 > Two potential-free change-over contacts per channel for signalling > Insulated point of suspension for clamps > Ambient temperature - 50... + 60 C 12723E00 The ground monitoring device ensures the electrostatic grounding of road tankers and rail cars while loading flammable liquids and powder. The device provides a conductive connection to the ground and monitors in parallel the quality of the electrostatic grounding. This guarantees that the electrostatic charge remains at a safe level and that no explosion hazard is generated by uncontrolled energy discharge. The following recommendation requires grounding during loading and recommends interrupting loading in case of incorrect grounding: > CENELEC LC/TR 50404 recommendation for avoiding ignition hazards due to electrostatic charges. > BGR 132 - BG rules for avoiding ignition hazards as a result of electrostatic charges ATEX / GOST Zone 0 1 2 20 21 22 Ex i interface x x For use in x x WebCode 8485A Control Devices /1

Selection Table Version Description Order number Weight kg Single-channel grounding system Single-channel ground monitoring device, without cable 8485/111-31 12.900 12635E00 Ground Monitoring Device 10 m ÖLFLEX with cable gland *); - 50... + 60 C 202500 2.900 Clamp with cable 12638E00 10 m ÖLFLEX with cable gland *); - 30... + 60 C 202502 4.000 Clamp with spiral cable 12640E00 12715E00 Grounding clamp with automatic cable winder Configuration set 12643E00 Automatic winder with 15 m of insulated cable and robust ergonomic grounding clamp, stainless steel, and fast-action plug - II 1 GD T6. Self retracting reel with 15 m Hytrel isolated cable Configuration set consisting of infrared adapter with USB port and CD-ROM with configuration software 105544 16.000 202511 0.500 /2 Control Devices

Selection Table Version Description Order number Weight kg Dual-channel grounding system Dual-channel ground monitoring device, without cable 8485/112-31 13.600 12633E00 Ground Monitoring Device Clamp with cable 12639E00 2 x 10 m ÖLFLEX and cable glands. Marked in yellow and black for correct correlation to indicating lamps. *); - 50... + 60 C 202501 4.800 Clamp with spiral cable 12641E00 2 x 10 m ÖLFLEX and cable glands. Marked in yellow and black for correct correlation to indicating lamps. *); - 50... + 60 C 202503 7.000 12715E00 Grounding clamp with automatic cable winder Automatic winder with 15 m of insulated cable and robust ergonomic grounding clamp, stainless steel, and fast-action plug - II 1 GD T6. Self retracting reel with 15 m Hytrel isolated cable 105544 16.000 Configuration set consisting of infrared adapter with USB port and CD-ROM with configuration software 202511 0.500 Configuration set 12643E00 *) Special cable length possible on request (max. 20 m). Price and date of delivery differ from the standard. Control Devices /3

Explosion Protection Explosion protection Europe (ATEX) Gas FTZÚ 09 ATEX 0059X E II 2 G Ex d [ib] IIB T4 Installation in Zones 1, 2 Certificates and approvals Certificates ATEX, Russia (GOST R), Belarus (GOST-B) Technical Data Electrical data Power supply Rated voltage Rated current Power consumption Output Signalling contact Minimum load Maximum load DC Maximum load AC Operating mode selection per channel LED display 230 +/- 10 % V AC 50 ma 10 VA two floating change-over contacts per channel 10 V DC / 100 ma 230 V DC / 0.25 A 40 V DC / 3 A 230 V AC / 3 A Road tanker and rail car recognition by means of DIP switch Selection via DIP switch Operating principle: LED display Grounding condition Reaction of the with road tanker grounding monitoring device Clamp is not connected, Grounding incorrect grounding equipment not in use Red indicating lamp ON Green indicating lamp OFF Contacts OPEN 10736E00 Clamp is directly grounded, e.g. via the loading platform Grounding incorrect Red indicating lamp ON Green indicating lamp OFF Contacts OPEN 10737E00 Clamps connected to tank vehicle. Grounding ok Red indicating lamp OFF Green indicating lamp ON Contacts CLOSED 10738E00 Clamps connected to tank vehicle. Tank vehicle is grounded subsequently (e.g. via the loading arm). Grounding ok Red indicating lamp OFF Green indicating lamp ON Contacts CLOSED 10739E00 /4 Control Devices

Technical Data Mechanical data Enclosure version Flameproof enclosure (Ex d) Degree of protection IP65 Material Enclosure Aluminium Grounding clamp Galvanised steel, contact point: copper Weight 8485/111-31 10.2 kg 8485/112-31 10.9 kg Ambient conditions Ambient temperature - 50... + 60 C Storage temperature - 50... + 60 C Assembly / Installation Cable glands Cable diameter range 6 12 mm Connection Maximum diameter, single-wire - rigid 2.5 mm 2 Accessories and Spare Parts Designation Illustration Art. no. Weight Key-operated switch - flexible 2.5 mm 2 - flexible, cable end sleeves with plastic cover 1.5 mm 2 - flexible, cable end sleeves without plastic cover 2.5 mm 2 Key-operated switch Series 8040 2 switching positions Key removable in 0 + 1 For use in Zones 1, 2, 21, 22 kg 130902 0.450 Flashlight and permanent light 12801E00 For manual by-pass of the signalling contactby authorised staff Flashlight and permanent light Series 6161 230 V AC, red For use in Zones 1, 2, 21, 22 120655 1.370 Additional signalling of the grounding condition Horn 12802E00 Horn Series 8491/1 with horn and connection lead 230 V AC For use in Zones 1 and 2 145280 1.450 Additional signalling of the grounding condition Flat horn 00446E00 10614E00 Flat horn 8491/2 with terminal compartment and cable gland 230 V AC For use in Zones 1, 2, 21, 22 Additional signalling of the grounding condition Further signalling and monitoring equipment can be found in the main catalogue. 145285 1.500 Control Devices /5

Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations 225 mm / 8.86 " 351 mm / 13.82 " 318 mm / 12.52 " 6 mm 0.24 " 126 mm / 4.96 " 98 mm / 3.86 " ø 11,5 mm ø 0.45 " 6 mm 0.24 " 225 mm / 8.86 " 180 mm / 7.09 " 351 mm / 13.82 " 318 mm / 12.52 " 126 mm / 4.96 " 98 mm / 3.86 " ø 11,5 mm ø 0.45 " 180 mm / 7.09 " 272 mm / 10.71 " 325 mm / 12.79 " 272 mm / 10.71 " 325 mm / 12.79 " 12758E00 Single-channel ground monitoring device 8485/111-31 Dual-channel ground monitoring device 8485/112-31 12759E00 380 mm / 14.96 " 192 mm / 7.56 " ø 10 mm ø 0.39 " 112 mm / 4.41 " 75 mm / 2.95 " Cable drum with automatic cable winder 04878E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /6 Control Devices