Installation & Operation Guide

Similar documents
Installation & Operation Guide

Installation & Operation Guide

Installation and Operation Guide

Installation and Operation Guide. KMD 5559 CommTalk

Installation and Operation Guide

EP/2 Installation Instructions

Quick Start Installation Guide

Installation and Operation Guide. BAC-5841/5842 UFAD and BAC / VAV Advanced Application Controllers, 8 x 8

BACnet Building Controller

THE CTB08D LIGHT CONTOLLER

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

XT-9100 Technical Bulletin

TPE 1464 Series Pressure Transducer

6222 Two Door Module Technical Operations Manual

Installation OVERVIEW

EX-RC1 Remote I/O Adapter

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Rev Cutler-Hammer Smart Breaker Panel Control Manual

NCH-1000 (Multiple Breaker Types) Installation Instructions

Suprex RS-485 SPX-7500 Wired Reader-Extender

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

BAC-9000 Series VAV Controller Installation Guide

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

PLCADD1616 User Guide 3/29/10. Overview

Digital Lighting Systems, Inc.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

EasyIO FC20 User Reference v1.3. EasyIO FC 20 DDC User Reference V1.3

Vorne Industries. 87/001 RS-485 Communications Board User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Resolver to Digital Expansion Board

ADDJOG User Guide 7/30/10. Overview

ETM-2050/ETM-2051 Service Manual

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note

Digital Lighting Systems, Inc.

2Installation CHAPTER TWO IN THIS CHAPTER. Checking Your Shipment Express Setup. Chapter 2 Installation 11

LCI AUXILIARY I/O TERMINAL BOARD DS200DDTBG_A

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision:

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT

SmartLock Controller INSTALLATION MANUAL

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

Custom Controller Installation Instructions

BA/BS4S Temperature Sensor Installation & Operating Instructions

Introduction. General Ratings

Seven Channel Remote Control

Ethernet Adapter Installation Instructions

PCL451. Manual Preset Indexer. User s Guide E Landon Drive, Anaheim, CA

TRC-190 User s Manual

SCD96 DMX Output Interface. Installation guide

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Vorne Industries. 87/415 Rate Monitor Display User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

Rev CH Breaker Gateway Installation and Operation Manual

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Stellar Instruments. SC1 Controller & Display System. General User s Manual. Copyright 2013 Stellar Instruments 1

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

OilCop Component Wiring Installation Manual

SPX-7400_SPX-7410_MAN_161028

LTEC Heat Pump DDC Controller

NETRONICS HS3500 CONTROLLER

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

rcc.1081 Installation Instructions

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

H704-42(H)(E), H704-42/1(H)(E)

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration

ETC Installation Guide

CA-A480-A Elevator Controller. Reference & Installation Manual

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

Accessories IC690ACC900

PWRguard PLUS Spring City Drive Waukesha, WI

POWERWISE INDAC SETUP MANUAL

V E2B Snap-in I/O Module

Vision OPLC V TR6/V350-J-TR6

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

OPLC Installation Guide

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

NSD/M1 Installation Instructions

PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer

Vorne Industries. 87/708 Master Clock Display User's Manual

Single Phase Systems-North American PC125/PC420 Series

TRC-190 User s Manual

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

User Interface Terminal for nvent RAYCHEM NGC Systems Installation Instructions DESCRIPTION TOOLS REQUIRED. Nonhazardous Locations LR67275

Channel Switch CS. General Operating, Maintenance and Installation Manual

Moxa TCC-100 Series Hardware Installation Guide

Transcription:

Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1

Introduction This section provides a brief overview of the KMD-5831 Programmable Loop Controller PLC-28 and the KMD-5821 Programmable Loop Controller PLC-16 + Direct Digital Controllers. Review this material before you attempt to install the controller. For clarity we will focus on the KMD-5831 but all installation and operating instructions apply equally to the KMD-5821. Illustration 1 shows the major controller components and their locations. The KMD-5821has fewer inputs and outputs. Input Pull-Up Switches Override Board Cover 1 2 3 4 5 6 Output Terminal Blocks 7 Input Terminal Blocks 8 Grounds Blank Cover AC Power Input RJ 12 Connector Isolation Lamps RS 485 Connector Status LEDs Illustration 1. Controller Components Note: Additional components are located under the blank cover. We will cover these in detail later in this document. 2

Installation This section provides important instructions and guidelines for installing the KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller. Carefully review this information prior to attempting installation. Mounting Use the four mounting holes to securely mount the controller using #6 hardware inside a UL-approved Enclosed Energy Management Equipment Panel or other suitable protective enclosure. Refer to Illustration 2. 1 2 3 4 5 6 7 8 6.00" 6.00" Illustration 2. Connector Detail Input Connections Universal Inputs Wiring connections are made depending on the intended application. Sixteen Universal Inputs are provided on the controller. Observe the following guidelines. (Refer to Illustration 2.) Connect device inputs to the input terminal connections (+). Connect input grounds to the associated ground terminal (-). 3

Installation KMD-5831 PLC-28 Direct Digital Controller Installation & Operation Guide Connecting Outputs Network Connections RJ-12 RS-485 Inputs If input pull-ups are required, refer to Configuration later in this section. Wiring terminals are suitable for up to two 12 22 AWG wires. If more than two wires are required, use an external terminal strip for additional connections. Note: Pulse inputs may be used under the following conditions: If the pulse input does not use a voltage variation, then leave the input pull-up in the On position. If the pulse produces voltage peaks (up to +5 VDC max.), then the input pullup must be set to the Off position. The maximum pulse rate is 8 HZ (8 pulse/sec). Twelve Universal Outputs are available for output connections labeled as 1 12 on the output terminal blocks. The outputs are grouped into three groups of four outputs each with a shared grounds (labeled SC ) in each block.. Each output can produce 50 ma at +12 VDC. If a greater current is required, KMC recommends the use of Override Boards discussed later in this section. A separate ground block provides six additional ground connections. The controller provides connections for two types of RS 485 circuits. The RJ 12 connector provides a six-wire RS-485 connection to a modem or PC using the KMD-5559 CommTalk Data Exchange Module. Simply connect a suitable RJ-12 cable between the devices. A RS 485 terminal is available for connections to a network of controllers If the Controller is at the End-of-Line, refer to Configuration after connections are completed. Detail The End-of-Line connection will have only one wire attached to the A and B terminals. For reliable operation, use Belden cable model #82760 or equivalent (18 gauge, twisted, shielded, 50 picofarads or less) for all network terminal block connections. Connect the nodes of the network in a daisy-chain arrangement. This means: Connect the A terminal in parallel with all other A terminals. Connect the B terminal in parallel with all other B terminals. Connect the shields of the cable together at each controller. 4

KMD-5831 PLC-28 Direct Digital Controller Installation & Operation Guide Installation Connect the shields to an earth ground (DO NOT use a chassis ground) only at one end of the segment; tape back the shield ground at the other end. Wiring Notes Use approved shielded cable and the following principles when connecting a controller to a network: Connect no more than 124 Tier 2 KMC addressable controllers or devices to the RS-485 network. Connect the nodes of the network in a daisy-chain arrangement. This means: Connect the A terminal in parallel with all other A terminals. Connect the B terminal in parallel with all other B terminals. Connect the shields of the cable together at each controller. Connect the shields to an earth ground at only one end of the segment; tape back the shield ground at the other end. Use a KMD 5575 repeater between every 32 Tier 2 controllers or if the cable length of the Tier 2 network exceeds 4000 feet (1220 meters). Use no more than seven repeaters per network. Place a KMD 5567 surge suppressor in the cable where it exits a building. Refer to Illustration 3 for an example of typical RS-485 connections. Wiring Shield Wiring Shield OR Wiring Shield KMC Controller Connections Illustration 3. Typical RS-485 Wiring Configuration 5

Installation KMD-5831 PLC-28 Direct Digital Controller Installation & Operation Guide Override Cards For large relays or devices that cannot be powered directly from a standard output, you will need to install an output override card. Override cards provide: a wide choice of output signals. a slide switch for automatic or manual control. an LED for assessment of the output state. The following Override Cards are available from KMC Controls. Model Number HPO-6701 HPO-6702 HPO-6703 HPO-6704 HPO-6705 Output Type Triac Relay - used for switching AC voltages of 1 Amp or less. Analog Override - Used for applications requiring manual adjustment of an analog control device. N.O. Mechanical Relay (Form A) - used to switch loads of up to 2 Amps, when switching DC circuits or when a dry contact is required and the device must be OFF when power is removed. 4-20 ma - used for applications requiring manual adjustment of an analog control device. N.C. Mechanical Relay (Form A) - used to switch loads of up to 2 Amps, when switching DC circuits or when a dry contact is required and the device must be ON when power is removed. Note Output cards must be powered with 24 VAC to enable the manual override (HAND) function. However, this connection must not be made until the default analog output jumper is removed. Installing Override Boards Table 1. KMD-5831 Override Board Options To install an Override Board: 1. Remove the appropriate cover from the module. The upper cover is for outputs 1 8 the lower for outputs 9 12. 2. Remove the jumper from the mounting header. 3. Press the override board onto the header pins. The Hand-Off-Auto selection switch is always positioned toward the output connections. (Refer to Illustration 4.) 4. If required, set the selection switch on the Override Board. 6

KMD-5831 PLC-28 Direct Digital Controller Installation & Operation Guide Installation Caution DO NOT connect active 24 VAC circuits to the output block unless the associated jumper is removed first. Doing so will result in damage to the output and prevent it from working. If the associated output will be an analog output, leave the jumper in place. 5. Connect output devices to the module. 6. Connect required power to the input module. Illustration 4 gives an example of a typical output module configuration. LED Selection Switch Remove jumper before installing board OR Remove jumper prior to connecting active 24 VAC circuits to the associated output terminals Illustration 4. Override Board Instalaltion Using Separate Banks The outputs are grouped into three banks that share a common switched-terminal. This connection is marked as SC on the output block. If you connect a circuit to this connector it then becomes common to all outputs in that bank. Configuration Configuration settings may be required for the inputs or the RS-485 connection. If you must activate or deactivate pull-ups on the inputs or set the end-of-line termination for the RS-485 connection, refer to Illustration 1 to locate the input switches and Illustration 6 for the End-of-Line switches. 7

Installation KMD-5831 PLC-28 Direct Digital Controller Installation & Operation Guide Input Pull-ups A 10K ohm resistor is available as a pull-up to a +5 VDC source voltage for passive or dry inputs on each input circuit. The resistor is switched On or Off using the two dip-switches at the top of the controller. The top switch is associated with the first 8 inputs and the lower switch is associated with the last 8 inputs. Illustration 5 shows on of these switches in greater detail. OFF OFF ON ON Illustration 5. Typical Input Pull-Up Switch (1 of 2) End-of-Line Switches The default setting for each input is the On position. In this position, the controller will provide +5 VDC to the input device. If the input is an active input, that is it has it s own current source, the pull-up for that input must be switched to the Off position. Illustration 6 shows the position of the End-of-Line switches associated with the RS 485 terminal. You must remove the lower blank cover to gain access to these switches End-of-Line Switches 8 Illustration 6. RS 485 End-of-Line Switches

KMD-5831 PLC-28 Direct Digital Controller Installation & Operation Guide Installation Illustration 7 shows the switch in greater detail ON OFF ON OFF Illustration 7. RS-485 End-of-Line Switch Detail Power Connection Configuration Programming If the controller is located at the end of the network segment the switches must both be placed in the default ON position. Otherwise, place the switches in the OFF position. Connect the 24 VAC supply voltage to the power connectors above the RJ 11 connector on the output side of the controller. Power is applied to the controller when the power supply (or transformer) is plugged in, as long as the Power jumper is in place. Illustration 6 shows a typical connection diagram for the controller. Note: The following guidelines apply. In general, use a separate Class 2 24 VAC transformer with the smallest VA rating that matches the specification. If several controllers are mounted in the same cabinet, you can share a transformer between them PROVIDED the transformer does not exceed 100 VA Prior to operating the controller, it must be configured using the Hardware Configuration Manager (HCM) application supplied with WinControl. Refer to the WinControl XL User s Manual for additional information. Note: All controllers on the same network must be configured for the same baud rate. Refer to the KMC Digital Applications Manual for information on how to program the controller. 9

Operation Controls and Indicators Status LEDs Isolation Lamps Power Jumper Resetting the Controller Once configured, programmed and powered up, the controller requires very little user intervention. The following sections describe the controls and indicators found on the card. Alternately, you may remove the RS-485 terminal block from the card to isolate the card from the network without disrupting network communications to other controllers. Two Status LEDs are located on the bottom left side of the controller. They are used to indicate the following: Communications This yellow LED flashes whenever the controller is communicating with other controllers over the RS-485 network connection. Ready This green LED indicates the controller has power and is operating normally. The LED will flash on and off at one second intervals. Two Isolation Lamps are located below the RJ 12 connector on the right side of the controller. These lamps serve three functions: Removing the lamps will open the RS-485 circuit and isolate the controller from the network. If one, or both, lamps are lit, it indicates the network is improperly phased. This means that the ground potential of the controller is not the same as other controllers on the network If the voltage or current on the network exceeds safe levels, the lamps operate as fuses to protect the controller from damage. The power jumper, shown in Illustration 8, can be used to remove power from the controller. This should be done anytime connections are made or changed on the controller. Removing the jumper opens the 24 VAC supply circuit. If the controller appears to be operating incorrectly, or is not responding to commands, you may need to reset the controller. 10

KMD-5831 PLC-28 Direct Digital Controller Installation & Operation Guide Operation Note Resetting the controller will restore the factory default configuration. If the devices cannot communite with the controller, or the controller cannot commnicate with other controllers, it may be necessary to re-configure the controller with HCM to establish normal communications and operation. Reprogramming may also be required. To reset the controller, proceed as follows. 1. Remove the lower Override Board cover on the controller. 2. Locate the Reset button (see Illustration 8). Watch Dog Jumper Power Jumper Reset Button Illustration 8. RS-485 End-of-Line Switch Detail 3. Locate and remove the Power Jumper from the current position. 4. Depress and hold the Reset button. 6. Reinstall the Power Jumper. (DO NOT release the Reset button.) 7. Continue to hold the Reset Button until the Communications LED flashes rapidly. 8. Release the Reset Button. This completes the reset sequence for the controller. 11

Disclaimer The material in this document is provided for information purposes only. The contents and the product(s) described herein are subject to change without notice. KMC Controls, Inc. makes no representations or warranties with respect to this document. In no event shall KMC Controls, Inc. be liable for any damages, direct or incidental, arising out of or related to the use of this document. Important Notices The KMC logo is a trademark of KMC Controls, Inc. 2003, KMC Controls, Inc. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form by any means without the written permission of KMC Controls, Inc.Printed in U.S.A. Technical Support If you have any questions about this technical document or need additional details, please call KMC Controls technical services at 574-831-5250 or e- mail us at techs@kmccontrols.com. KMC Controls P.O. Box 497 19476 Industrial Drive New Paris, IN 46553 U.S.A. TEL: 574.831.5250 FAX: 574.831.5252 E-mail: info@kmccontrols.com 12 902-019-04B