Liebert 80-eXL from 100 to 1200 kw. Enhanced Design and Improved Efficiency

Similar documents
Liebert 80-eXL from 160 to 500 kw. Enhanced Design and Improved Efficiency

Liebert EXL TM S kw to 1200 kw. Enhanced Design and Improved Efficiency

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes

Liebert NXC from 10 to 200 kva

Liebert. EXL S1 from 100 to 1200 kw. Enhanced Design and Improved Efficiency

Liebert. EXS from 10 to 20 kw. Optimized and integrated three-phase UPS solution with high efficiency power protection

Liebert. NXC from 10 to 200 kw. Compact and Reliable Power in a Fully Integrated Packaged Solution

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

Liebert NX from 30 to 60 kw. AC Power for Business-Critical Continuity

Chloride Trinergy from 200 to 1200 kw

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

Liebert SX TM. 60kVA to 200kVA UPS Three Phase Input, Three Phase Output

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

Liebert NXC from 10 to 60kVA

Tel: AC Power for Business-Critical Continuity TM

exm UPS 80kW - 200kW Efficient, Flexible Power Optimized For Medium Size UPS Applications

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

VERTIV SERVICE CAPABILITY

Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency

Hipulse-U UPS 80kVA - 500kVA Utmost Reliable Power Solution for Critical Business Applications

ITA2 UPS 5-20kVA Compact, Efficient & Robust UPS For Critical Applications

ITA2 UPS 5-20kVA Compact, Efficient & Robust UPS For Critical Applications

Chloride CROSS Rack 16 A, 32 A and 63 A

CRITICAL INFRASTRUCTURE ASSESSMENTS

Liebert APM. The Compact Row-Based UPS With FlexPower Technology TM. AC Power for Business-Critical Continuity

Liebert APM. The Compact, Row-Based UPS with Flexpower Technology 30kW - 300kW

Liebert PDX from 15 to 120 kw

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

UPS PRO MODERNÍ DATOVÁ CENTRA. Rastislav Smatana AC Power Sales Manager CZ&SK

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

Liebert PDX from 15 to 120 kw

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

The Power of Modularity

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

Liebert NXr Series 15KVA to 90KVA (208V/220V) AC Power for Business-Critical Continuity

Liebert. ITA2 TM UPS 5-20kVA Compact, Efficient & Robust UPS For Critical Applications

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

Liebert exm, 80kW - 200kW

Liebert NX - Next Generation UPS for protecting your Business Critical Systems. AC Power Systems for Business-Critical Continuity

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups

Liebert exm TM. 80kW - 200kW Efficient, Flexible Power Optimized For Medium Size UPS Applications

Liebert exm UPS kva/kw Efficient, Flexible Power Optimized for Midsize Applications FLEXIBLE. ECONOMICAL. INTELLIGENT

LEVELUPS T3 3 UPS. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability with Embedded Isolation Transformer

MGE Galaxy /900 kva

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM

Liebert GXT MT kva

Liebert APM UPS The Industry s Highest Energy Efficiency In A Row-Based, On-line UPS. AC Power For Business-Critical Continuity

PowerWAVE 9250DPA. ( N+1 kva/kw) Parallelable up to 1.5 MVA/MW

the Centric 300 An advanced modular UPS up to 1800kVA/kW

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Liebert APM. The Compact Row-Based UPS With Flexpower Technology TM. AC Power for Business-Critical Continuity

Est FlexiPower Maxi. Modular UPS kw

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

TME Modular Series UPS System kva/kw - 208/220 VAC

Liebert NX Series. 30kVA to 200kVA. AC Power for Business-Critical Continuity TM

Liebert. EXL UPS 800 and 1200kVA Single Module and Multi-Module Systems

SmartCabinet Intelligent, Integrated Containment for IT Infrastructure

ARCHIMOD HE 240/480 HIGH POWER MODULAR UPS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

Chloride. FP-60z 5 160kVA 1ph / 3ph Industrial AC UPS System

Est ComPower Mini. Compact UPS kva

Eaton 9EHD Industrial UPS

Managed Rack PDU MPH2 More efficient Simpler Better

3-L Green Conversion. Compact footprint

Liebert NX Series. 30kVA to 200kVA. AC Power For Business-Critical Continuity

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

LP 33 Series UPS. Digital Energy. GE Digital Energy

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

Galaxy VX. From 500 kw to1500 kw N+1 Parallel solutions up to 4000 kw 480 V. schneider-electric.com

Socomec Netys PR RT U P S TOWER / RACK MOUNT

Modular UPS S KVA

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

Multi Power x 42 kw up to 1 MW + redundancy 3:3 VFI TYPE. Utmost Availability Ultimate Scalability Unmatching Power Density

Liebert. PDX from 15 to 165 kw. Direct Expansion Solution for Small and Medium Data Centers

Liebert NX, kva/kw UPS Maximum Efficiency in a transformer-free, High Efficiency, Scalable On-line UPS EFFICIENCY. AVAILABILITY.

MGE Galaxy /30/40/60/80/100/120 kva. The recommended power protection for all critical applications.

Modular three-phase UPS system. Conceptpower DPA kva True modular UPS system for critical applications

VERTIV LIFE SERVICES. Remote Diagnostic and Preventive Monitoring

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Schneider Electric Easy UPS 3S

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

THOR Modular. Modular UPS system. Online double-conversion Scalable Decentralized Parallel. Modular. 10, 20, 30, 40kVA modules kVA systems

Single phase UPS. Applications. Highlights. 1ph from 450 VA to 10 kva. Home Office Computers and peripherals Networks and servers Small data centers

Critical Power 2017 Catalogue

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Est FlexiPower Maxi UPS FPX Maxi kVA

Maximum Efficiency UPS Protection in an Intelligent, Low TCO Design Liebert exl UPS kVA, Single Module and Multi-Module Systems

Rack & Enclosure Systems

Liebert. PCW from 25 to 220 kw. Chilled Water Units Optimizing Data Center Efficiency

UPS TRIFASE kVA Rev. 8 Serie TPH IGBT

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity

SmartMod Intelligent, Integrated Infrastructure for the Data Center

Eaton 9EHD Industrial UPS

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application

Transcription:

Liebert 80-eXL from 100 to 1200 kw Enhanced Design and Improved Efficiency

Emerson Network Power, a division of Emerson, is a global company that combines technology with design to supply innovative solutions for the benefit of its customers. Emerson Network Power protects and optimizes critical infrastructure for data centers, communications networks, healthcare and industrial facilities. Emerson Network Power s broad technology base and global expertise support a full spectrum of enterprise-wide solutions for today s vital business needs. Regardless of your size, you can t afford for your critical business systems to go down and you can t waste time recovering your IT infrastructure after a disruption. Leave that to us, the experts in grid to chip solutions, from the biggest to the smallest data centers, we are ready to serve your needs. More standardization, so you don t need further budget allocations to install it. More simplification so you don t need to be a specialist to get the best for your business. More support, so while you are enjoying doing business, we are protecting you. 2

3

#DataCenter Liebert 80-eXL The New T-free Monolithic UPS Generation Delivering Secure Power and Maximized Energy Saving Highlights Extraordinary double conversion efficiency up to 97% Intelligent ECO mode efficiency above 99% Intelligent paralleling feature optimizes efficiency at partial load Maximized active power at unity power factor Liebert 80-eXL, the new generation of 80-NET UPS, delivers unsurpassed performance to mediumlarge data centers as a result of proven track record, successes, a reliable large installed base and more than 10 years of acquired experience with the 80-NET technology. The new Liebert 80-eXL is a monolithic product that features a transformer-free design with a full IGBT three-level topology, providing extraordinary features including a double conversion efficiency of up to 97% plus intelligent paralleling to optimize efficiency at partial load, thus achieving superior running cost savings as well as reduced TCO and CO 2 emissions. Furthermore, its higher power density in a minimum footprint optimizes the availability of IT space and reduces related costs. Liebert 80-eXL, available from 100 to 1200 kw, delivers secure power while providing first class load protection and maximum energy saving for mission critical applications. Compact footprint for optimum space utilization Backward compatibility with previous 80-NET generation >2.5 GW worldwide 4

Capacity & Installation Flexibility from 100 kw up to 9.6 MW Liebert 80-eXL features a transformer-free design with full IGBT three-level double conversion technology, providing extraordinary savings on installation and running costs, while at the same time delivering first class load protection. Liebert 80-eXL also features a full IGBT three-level rectifier allowing for electrical infrastructure cost saving, reducing the size of gensets, circuit protection, cabling and transformers. Flexibility and Compatibility Liebert 80-eXL can be fully adapted to meet diverse system requirements in terms of power capacity and redundancy allowing for different system designs, thus ensuring maximum flexibility: Output Power Factor up to 1 Output Power Factor diagram symmetrical respect to zero Permanent 100% kva - no derating with any load (lagging or leading) Optimum space/power ratio. kvar % 100 80 60 40 20 0 20 40 60 80 100 100% KVA 100% KVA Leading Cosφ 0.5 25 50 75 Cosφ 0.5 Lagging Cosφ 0.8 Cosφ 0.9 100% KVA 100% KVA Cosφ 1 100% kw Cosφ 0.9 Cosφ 0.8 Maximized active power, high efficiency and complete compatibility for modern, mission critical IT loads. Features and Performance Transformer-free design Full IGBT three-level NPC2 topology Excellent input performances: - PF > 0.99 - THDi < 3% Automatic output power upgrade of up to +10% Output PF diagram symmetrical respect to zero Three and four wire electrical compatibility Centralized and distributed parallel capabilities Seismic compliance 5

Improved Efficiency Liebert 80-eXL delivers an outstanding double conversion efficiency of up to 97%, consequently reducing operating costs and energy dissipation (kw) to a minimum. This significantly minimizes the consumption of the cooling system, providing an overall TCO reduction and rapid payback time. Furthermore, through its intelligent ECO mode efficiency and the intelligent paralleling feature Liebert 80-eXL can optimize efficiency even at partial load achieving additional superior cost savings. Liebert 80-eXL levels of efficiency and consequent electricity cost savings can be attribuited to: Latest generation IGBT Adoption of a three-level NPC2 topology for both rectifier and inverter DC controlled fan speed Intelligent paralleling mode Advanced digital technology and fast transfer The seamless activation of Liebert 80-eXL s functioning modes ensures the highest level of efficiency without compromising power quality and availability. Fast transfer technology ensures the quickest response time under various conditions: Network fault (voltage variation, high/low impedance mains failures) Load fault (short circuit downstream of the UPS) Type of load connected (PDU transformer) Double Conversion Mode (VFI) provides the highest level of power conditioning and protects the load from all electrical network disturbances. Intelligent ECO Mode (VFD) detects when conditioning is not required and allows the energy flow to pass through the bypass line. The unit is able to discriminate between various types of interferences and rapidly respond, while at the same time ensuring compatibility with downstream equipment such as servers, transformers, STS or mechanical loads. Static Bypass Rectifier Static Bypass Rectifier Manual Bypass Batteries Manual Bypass Batteries Inverter Inverter Output LOAD Output LOAD 6

#EnergyEfficiency Intelligent Paralleling Liebert 80-eXL Intelligent Paralleling Feature Activating the intelligent paralleling feature optimizes efficiency at partial load, thus achieving superior running cost savings. Enabling this feature allows the system to automatically adapt capacity to meet immediate load requirements by switching excess units to standby mode, while ensuring continued system availability. Furthermore, the Intelligent Paralleling feature allows each Liebert 80-eXL unit to operate in standby mode for the same amount of time, ensuring an equal life-span of module components. This intelligent paralleling feature further maximizes Liebert 80-eXL s double conversion efficiency at partial load and allows for an overall energy dissipation and TCO reduction. 33% Four units at 33% load each = 96% efficiency. 65% Liebert 80-eXL Intelligent Paralleling: two units at 65% load each = 96.8% efficiency Efficiency (%) 100% 95% 90% 85% 80% 0 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Liebert 80-eXL / efficiency with Intelligent Paralleling feature Load (%) 7

#UPSsystems Parallel Configurations The Liebert 80-eXL can be connected with up to 8 units in parallel, where single units can be serviced while the remaining units continue to power the load. A Liebert 80-eXL unit continues to operate even while it s being upgraded to a parallel system due to the upgrade occurring via software settings. Furthermore, Liebert 80-eXL is backward compatible with the previous 80-NET generation, so as to facilitate any legacy system power upgrade. Liebert 80-eXL can support both distributed and centralized parallel configurations providing maximum energy saving via double conversion and intelligent ECO mode, allowing to operate with a system efficiency of up to 99%. Distributed Parallel Configuration Paralleling single Liebert 80-eXL units offers advanced scalability. In a distributed parallel configuration, each unit has a dedicated static bypass switch, providing parallel operation without the need for a system control cabinet, thus reducing initial installation costs. Bypass Load Liebert 80-eXL distributed parallel configuration, with 8 UPS units in parallel Centralized Parallel Configuration With the Liebert 80-eXL s centralized parallel configuration, the internal static bypass switch of each unit is disabled and an external Main Static Switch (MSS) rated for the desired maximum capacity, is installed. Therefore, the reserve supply to the loads operates via one central piece of equipment (MSS). The MSS can easily be integrated into any switchgear, thus simplifying cabling and installation. System level commands are given to the MSS via its integrated touch screen display. Bypass MSS Load Liebert 80-eXL centralized parallel configuration, with MSS plus 8 UPS units in parallel 8

User Interface and Advanced Diagnostic Liebert 80-eXL makes your mission critical space a peaceful place through its advanced diagnostic capability, measuring and logging, enhanced event analysis as well as an intelligent colored multi-language touch screen display. 1 2 9 80-eXL Liebert 80-eXL advanced DSP control platform together with the patented Vector Control technology enables increased performance of three-level power converters and real time control of output power quality, guaranteeing continuous operation and premium protection for your customer s business. 3 4 5 6 7 8 1. Bypass Input Voltage and frequency measurements. 2. Input Current, voltage and frequency values of the three input phases. 3. Warning/fault Alerts of anomalies on bypass, rectifier, inverter, booster/charger, battery and load. 4. Events log Date and time of important UPS events, alarms and other warnings. 5. Measurements Voltage, current and frequency values of each internal functional block. 6. Battery Status/values including temperature, cell voltage, capacity run time and testing. 7. LIFE Status of LIFE connections and calls. 8. Tools LCD settings and language selection. 9. Output Voltage, current, frequency, and battery measurements. 9

Reduced TCO Neutral Carbon Footprint Liebert 80-eXL s new generation architecture has been designed to reduce energy and heat dissipation, consequently minimizing the demand and consumption of air conditioning systems. The combination of these factors, coupled with a double conversion efficiency of up to 97%, reduces CO 2 emissions to a minimum. This contributes to ensuring that your customers data centers are a step closer to meeting the industry s environmental and efficiency compliance standards. Advanced control diagnostic, excellent operating efficiency, intelligent paralleling feature, minimum footprint and high energy density make Liebert 80-eXL the perfect UPS to deliver secure power to all mission critical applications, maximum energy saving and rapid return on investment. Liebert 80-eXL provides system capacity from 100 kw up to 9.6 MW which can be adapted according to diverse design requirements in terms of flexibility, redundancy and system reliability. 97% Double Conversion Efficiency Furthermore, its high power density in a minimum space allows customers to maximize the number of racks and servers housed in their data center, thus granting more space for IT equipment. The Liebert 80-eXL technology, has brought extraordinary benefits in terms of: Zero impact on upstream infrastructure Perfect compatibility with modern mission critical loads Enhanced performances for maximum energy saving CO 2 emission reduction Maximum system flexibility for all installations Reduced TCO. CO 2 950 tons of CO 2 saved every year 10

Thermal Management Unit Servers Normal UPS Unit Data Collection Critical Customer Engineer On-site Visit #LIFERemoteService YOUR FILITY LIFE 24/7 SERVICE CENTER LIFE TM Remote Diagnostic and Preventive Monitoring Service Emerson Network Power s service program is designed to ensure that your critical power protection system is maintained in an optimum state of readiness at all times. The LIFE remote diagnostic and preventive monitoring service provides early warning of UPS conditions and out of tolerances. This allows effective proactive maintenance, fast incident response and remote trouble shooting, giving customers complete security and peace of mind. With LIFE services you will benefit from: Uptime Assurance Constant monitoring of UPS parameters, thus maximizing the system availability. First Time Fix Rate Proactive monitoring and data measuring ensure that when our customer engineers are dispatched on-site, they arrive prepared for first time resolution. Proactive Analysis From LIFE service centers, our experts proactively analyze the data and trends of your equipment, to recommend actions ensure their best performance. Minimized Total Cost of Ownership of Your Equipment The continuous monitoring of all relevant parameters maximizes unit performance, reduces onsite maintenance and extends the life of your equipment. Fast Incident Response LIFE allows for immediate definition of the best course of action, as a result of the regular communication between your Liebert 80-eXL system and our LIFE service centers. Reporting You will receive a comprehensive report detailing the working order of your equipment and its operational performance. 11

Customer Monitoring Interfaces Trellis Platform Emerson Network Power s Trellis platform is a real-time infrastructure optimization platform that enables the unified management of data centre IT and facilities infrastructure. The Trellis platform software can manage capacity, track inventory, plan changes, visualize configurations, analyze and calculate energy usage, and optimize cooling and power equipment. The Trellis platform monitors the data center, providing a thorough understanding of system dependencies to help IT and facilities organizations keep the data center running at peak performance. This unified and complete solution, delivers the power to see the real situation in your data center, make the right decision and take action with confidence. LCD Touch Screen Features High security access with separate password levels for users and service engineers User-friendly graphical interface Single-line mimic diagram showing system status Dedicated warning/fault and event log page used to monitor USP status and important events Dedicated measurements page for all UPS internal functional blocks Hardware Connectivity Liebert 80-eXL allows for the monitoring and control of networked UPS, through different protocol options: The integration of UPS with Building Monitoring and Automation Systems via MODBUS RTU, MODBUS/TCP or JBUS protocols The integration of UPS in Network Management Systems through SNMP protocol Two slots for additional connectivity cards are available for specific protocol requirements. Software Connectivity Liebert Nform will monitor the Liebert 80-eXL via SNMP protocol. Authenticated alarm management, trend analysis and event notification delivers a comprehensive monitoring solution. Available in a variety of versions to suit anything from small computer rooms to multiple location distributed IT networks, Liebert Nform enables: Condition based system state recording Alarm event exporting to disk SMTP email Execution of external program Shut down clients Liebert SiteScan is a centralized site monitoring system which ensures maximum visibility and availability of critical operations. Liebert SiteScan Web allows users to virtually monitor and control any piece of critical support equipment. Its features include real-time monitoring and control, data analysis, trend reporting, and event management. 12

#CustomerExperienceCenter Customer Experience Center Emerson Network Power s state-of-the-art Customer Experience Center located in Castel Guelfo (Bologna - Italy), enables our customers to experience first-hand a wide variety of data center technologies, supported by constant consultation from R&D and engineering specialists. Customers visiting the center will be able to witness pre-installation demonstrations, covering the technical performance, interoperability and efficiency of Emerson UPS systems under real field conditions. These processes can be experienced from the facility s control room, where real-time performance measurements and reporting will be available while providing full visibility of the demonstration area. The center can host simultaneous tests at full load of up to 4000 A. The customer validation area specifically dedicated to UPS consists of four testing stations, each one providing up to 1.2 MVA of capacity. Testing includes individual modules, as well as complete power systems, with the added possibility of the customer s switchgear support systems being connected, thus guaranteeing smooth, rapid installation and commissioning of large power systems. Testing is also customized based on the complexity, size and number of UPS components in the configuration. Our Customer Experience Center offers three validation experiences: Demo - carried out on new products to demonstrate UPS performance Standard - validation test showing UPS standard technical performances in compliance with UPS catalogue and IEC 62040-3 standards Customized - session tailored to validating customer s specific technical performance needs. 13

Liebert 80-eXL Specifications Technical Specifications UPS Rating (kva) 100 120 160 200 300 400 500 600 800 1000 1200 Output active power at 35 C*(kW) 100 120 160 200 300 400 500 600 800 1000 1200 Output active power at 40 C (kw) 90 108 144 180 270 360 450 540 720 900 1080 Input Nominal mains input voltage / voltage range* (V) 400 (200 to 460), 3Ph or 3Ph + N Nominal bypass input voltage / voltage range* (V) 400 (380/415 selectable), 3Ph or 3Ph + N Nominal frequency / frequency tolerance (Hz) 50±10%(60 selectable) Input Power Factor 0.99 Input current distortion (THDi) (%) 3 Output Nominal output voltage (V) 400 (380/415 selectable), 3Ph or 3Ph + N Nominal output frequency (Hz) 50 (60 selectable) Output voltage stability by load variation 0-100% (%) - static ±1 Complies with IEC/EN 62040-3, Class 1 - dynamic Output frequency stability - synchronized with bypass mains (%) ±2 (2, 3, 4, 5 selectable) ±0.1 - synchronized with internal clock (%) Inverter Overload Capacity* 110% continuous, 125% for 10mins, 150% for 1min Short circuit current for 200 ms 2.2 In Load crest factor handled without derating the ups (Ipk/Irms) 3:1 Compatibility with loads Any power factor (leading or lagging) up to 1 Battery Permissible battery voltage range (V) 396 to 700 Float voltage for VRLA @ 20 C (V/cell) 2,27 End cell voltage for VRLA (V/cell) 1.65 Float Voltage stability in steady state condition (%) 1 DC ripple voltage without battery (%) 1 Battery Switch Not included Bypass Manual Maintenance Bypass Included 100-500 kw Not included 600-1200 kw General and System Data Classification according to IEC/EN 62040-3 VFI-SS-111 Operating Temperature ( C) 0-40 Maximum relative humidity @ 20 C (non condensing) (%) Protection degree with open doors IP 20 Frame colour (RAL scale) 7021 Noise @ 1 metre as per ISO 3746 (dba ± 2dBA) 65 67 69 71 76 78 64 dba @partial load 65 dba @partial load 70 dba @partial load 72 dba @partial load Parallel configuration up to 8 units in parallel Access Front and Top (no rear access required) / efficiency: - VFI according to IEC/EN 62040 definition (%) up to 97% - VFD according to IEC/EN 62040 definition (%) up to 99% Dimension and Weight Height (mm) 1950 Width (mm) 500 750 1000 1250 2000 2650 Depth (mm) 900 Net Weight (kg) 370 510 725 990 1550 2275 *Conditions apply up to 95 14

Emerson Network Power Data Center Infrastructure for Large Applications 4 4 6 4 7 1 3 1 7 5 UPS Trinergy Cube 3.4 MW Highest average operating efficiency in the industry: 98.5% Unprecedented levels of installation flexibility Hot scalability up to 3.4 MW Liebert 80-eXL 1200 kw Three-level Double conversion efficiency of up to 97% plus intelligent paralleling Intelligent ECO mode (VFD) efficiency above 99% Enhanced energy density and compact footprint Parallel system configuration up to 8 units with both centralized and distributed parallel capabilities 4 2 Remote Diagnostics LIFE Remote Diagnostic and Preventive Monitoring Service With LIFE Service you will benefit from: Uptime assurance First time fix rate Proactive analysis Minimized total cost of ownership of your equipment Fast incident response Reporting Liebert NXL 800 kva UPS for critical high power applications Provides greater power capacity along with superior reliability Meets power requirements and energy efficiency in high availability data centers Static Transfer Switch Chloride CROSS Ensures redundant power for critical loads, switching between two independent power sources Solid-state transfer switch available as 2/3/4P versions with full PF range to guarantee compatibility with all load types Extremely reliable and flexible architecture 1 Power 2 Infrastructure Management & Monitoring 3 Power Switching & Controls 7 DC Power Thermal 4 Management 5 Racks & Integrated Cabinets 6 Surge Protection

Ensuring The High Availability Of Mission-Critical Data And Applications. About Emerson Network Power Emerson Network Power, a business of Emerson (NYSE:EMR), is the world s leading provider of critical infrastructure technologies and life cycle services for information and communications technology systems. With an expansive portfolio of intelligent, rapidly deployable hardware and software solutions for power, thermal and infrastructure management, Emerson Network Power enables efficient, highly-available networks. Learn more at www.emersonnetworkpower.eu Locations Emerson Network Power Global Headquarters 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229, USA Tel: +1 614 8880246 Emerson Network Power Power Europe Middle East and Africa Via Fornace, 30 40023 Castel Guelfo (BO) Italy Tel: +39 0542 632 111 Fax: +39 0542 632 120 power.networkpower.emea@emerson.com Emerson Network Power United Kingdom George Curl Way Southampton SO18 2RY, UK Tel: +44 (0)23 8061 0311 Fax: +44 (0)23 8061 0852 While every precaution has been taken to ensure accuracy and completeness herein, Emerson assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice. MKA4L0UK80EXL Rev.3-05/2016 Globe Park Fourth Avenue Marlow Bucks SL7 1YG Tel: +44 1628 403200 Fax: +44 1628 403203 UK.Enquiries@Emerson.com EmersonNetworkPower.eu Follow us on Social Media: Emerson. Consider it Solved, Liebert, LIFE, Trellis, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. or one of its affiliated companies 2016 Emerson Electric Co. All rights reserved.