Some Joules Are More Precious Than Others: Managing Renewable Energy in the Datacenter

Similar documents
GreenSlot: Scheduling Energy Consumption in Green Datacenters

Geographical Load Balancing for Sustainable Cloud Data Centers

Concentrating Renewable Energy in Grid-Tied Datacenters

Peter X. Gao, Andrew R. Curtis, Bernard Wong, S. Keshav. Cheriton School of Computer Science University of Waterloo

Last Time. Making correct concurrent programs. Maintaining invariants Avoiding deadlocks

Distributed Pervasive Systems

Data centers & energy: Did we get it backwards? Adam Wierman, Caltech

The current state of the electrical grid And the technologies that will enable its transformation

Sustainability: It s not just for tree-huggers. Nicole Peill-Moelter Director of Environmental Sustainability

A Computer Scientist Looks at the Energy Problem

A More Sustainable Approach to Enterprise Data Storage: Reducing Power Consumption with InfiniBox. Executive Brief

MindSphere meets energy

Integrated Resource Planning April 20, 2010

Demand Management from an Aggregator's Perspective

TriStar MPPT (150V and 600V) Wind Charging Control Info

Christian PAYERL, Poznan, 20 th May, 2009 ABB FACTS Grid connection of Wind Farms. ABB Group May 22, 2009 Slide 1

Assessing Opportunities to Exploit Stranded Power

PSL. Power Quality & Energy Monitoring. PQube power quality & energy analyzer. Low-Cost, High-Precision

One (1) acoustic and three (3) seismic channels. Three (3) component velocity output. All units are interchangeable with accuracy within two percent.

An End2End (E2E) Operationalized Pipeline for Predictive Analysis for the Intelligent Grid

Energy Management of MapReduce Clusters. Jan Pohland

Pros and Cons of Various DC Distribution Architectures

ENERGY STAR for Data Center Products: UPS plus Servers, Storage, and more April 24, 2012

Chris Hickman President, Energy Services

CHAPTER 6 STATISTICAL MODELING OF REAL WORLD CLOUD ENVIRONMENT FOR RELIABILITY AND ITS EFFECT ON ENERGY AND PERFORMANCE

Power Attack Defense: Securing Battery-Backed Data Centers

Ft Worth Data Center Power Metering for Real Time PUE Calculation. Scope of Work

EP s approach to Power & Energy efficiency in DCs & paradigms

A First Look at Colocation Demand Response

Newave s approach for protecting mission critical application

AN ADVANCED ENERGY EFFICIENT RACK SERVER DESIGN WITH DISTRIBUTED BATTERY SUBSYSTEM BAIDU: SUN XIAOGUANG

BATTERY STORAGE SOLUTIONS

Addressing Data Center Efficiency Lessons Learned From Process Evaluations of Utility Energy Efficiency Programs

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Towards Energy-Proportional Datacenter Memory with Mobile DRAM

Consolidating Complementary VMs with Spatial/Temporalawareness

Leveraging Energy Storage Towards Cost Effective Datacenters Di Wang

Case Study: Energy Systems Integration Facility (ESIF)

Energy Efficiency for Exascale. High Performance Computing, Grids and Clouds International Workshop Cetraro Italy June 27, 2012 Natalie Bates

Impact of Distributed Generation on the Cost Effectiveness of Large Power Plants

A Distributed Framework for Carbon and Cost Aware Geographical Job Scheduling in a Hybrid Data Center Infrastructure

From Wires. To a Platform based Electricity System. Nikos Chatziargyriou Chairman and CEO of HEDNO

SIX Trends in our World

Data centers control: challenges and opportunities

Shen, Tang, Yang, and Chu

Power and Locality Aware Request Distribution Technical Report Heungki Lee, Gopinath Vageesan and Eun Jung Kim Texas A&M University College Station

ENERGY-EFFICIENT VISUALIZATION PIPELINES A CASE STUDY IN CLIMATE SIMULATION

Converged Power Solutions. Data center power reinvented


E f f i c i e n c y b e y o n d t h e A C b a s e d d a t a c e n t e r d e s i g n s ; V D C p o w e r f e e d s o l u t i o n

Automated load balancing in the ATLAS high-performance storage software

aentron Energy System 1 to 900 Vdc

DATA CENTER COLOCATION BUILD VS. BUY

POWERLINE SIGNAL COUPLERS xx for Intellon INT6300/INT6400 Designs

Energy Efficient in Cloud Computing

Virtual Melting Temperature: Managing Server Load to Minimize Cooling Overhead with Phase Change Materials

SharePoint Migration Cleanup and Pre-Migration Checklist for Success

A data model for supplying a Data Center with several energy sources. 18 juillet Inès de Courchelle IRIT/LAAS

ITU-T L Energy efficiency metrics of a base station site

power quality Models 8230 & 8220

Project DINAR Pooled BEMI (Bidirectional Energy Management Interface), Germany

Energy Storage Integration

How green is green? The environmental benefits of using Diesel Rotary UPS systems to support critical loads in the datacenter. Summary.

Capturing the benefits of Distributed Energy Resources through a holistic and integrated data and automation/control based approach.

IT Optimization Under Renewable Energy Constraint

Wireless Irrigation Control System

An Approach to Addressing QoE for Effective Video Streaming

Measurement and Management Technologies (MMT)

Why Scale Matters & How the Cloud Really is Different

VP and Chief Technology Officer

A Dell Technical White Paper Dell

Wind Plant Systems Grid Integration Plant and Turbine Controls SCADA

Lab Test Report DR100401D. Cisco Nexus 5010 and Arista 7124S

Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group

Data Centers: The Case For Energy Risk Management and Energy Reliability

Efficiency Works Business: 2017 Rebates & Goals. January 17, 2017

Power Control in Virtualized Data Centers

Rack Centric - High Voltage Distribution

DIgSILENT Grid Code v1.0

System Acceptance Testing & Performance Evaluation of Battery Energy Storage Systems

Power Provisioning for Diverse Datacenter Workloads

Expanding Transmission Capacity: Options and Implications. What role does renewable energy play in driving transmission expansion?

Hitachi s experience in developing Smart Grids Shin-ichi INAGE Renewable Energy & Smart Grid Division, Hitachi Ltd.

Southern California Edison. Leading the Way in Electricity TM

Energy efficient optimization method for green data center based on cloud computing

Session 6: Data Center Energy Management Strategies

Data Center Power and Cooling (and More)

Designing Power-Aware Collective Communication Algorithms for InfiniBand Clusters

2017 DCMME The Future Of Manufacturing for Energy and IoT Is Happening Today in Indiana!

How to Conduct an Energy Audit Using the Energy Platform EP1

I/O Systems (4): Power Management. CSE 2431: Introduction to Operating Systems

IFR 6000 Transponder/DME Ramp Test Set

Systems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development

Utility Interconnection. Highlights of the New Fast Track Process Proposed by FERC and Changes to IEEE 1547

Towards Deploying Decommissioned Mobile Devices as Cheap Energy-Efficient Compute Nodes

Innovative Data Center Efficiency Techniques. Michael K Patterson, PhD PE Eco-technology Program Office Intel Corporation

DC Power Distribution System Standards Next Generation Net Zero Energy Commercial Buildings

Power Supplies. Chapter The McGraw-Hill Companies, Inc. All rights reserved. Mike Meyers CompTIA A+ Guide to Managing and Troubleshooting PCs

JouleSort: A Balanced Energy-Efficiency Benchmark

Powering Progress: Smarter, Sustainable, More Secure, and Resilient Energy Infrastructure

Transcription:

Some Joules Are More Precious Than Others: Managing Renewable Energy in the Datacenter Christopher Stewart The Ohio State University cstewart@cse.ohio-state.edu Kai Shen University of Rochester kshen@cs.rochester.edu

Clean, Green Renewable Energy Benefits: Green and Green Reduce carbon footprint compared to Grid (now) Green House Data 10,000 sq. ft. in WY Wind powered Similar datacenter plans in CA, TX, MA, NY & NE The Grid's future is uncertain, but a long way from being mostly clean Coal still 2X in 2030 [EIA, 2009] Slide 2

Profitable, Green Renewable Energy Benefits: Green and Green Equipment produces a lot of energy; low maintenance & human costs AISO.net Solar-powered datatcenter in CA Competitive monthly hosting $9.95-$50 Profitable Energy storage not as important as in Grid Incremental growth [Google's Solar Panel Project] Buy equp. or pay as a service Amortize cost over equip. lifetime Slide 3

The Intermittency Problem Applications in the datacenter must be available 24x7 But wind and solar energy are intermittent Datacenters powered by renewable energy need backups Primary options: Grid, generator, battery Alternatives are either dirty and/or costly Renewables are precious! renewable = joule converted from solar/wind The preferred energy source Available only sometimes and costly to store Slide 4

Position Statement 1. Datacenter design and management should strive to increase the use of renewables Opportunities Capacity planning Load balancing Compute power should fluctuate with intermittent outages i.e., turn machines off Route requests to datacenters with unused renewables [K. Le-HotPower-2009] [A. Hopper-2008] Migrate services to datacenters with renewables 2. Need mechanisms for renewable-aware management Slide 5

Intermittent Renewables are More Precious Every Joule is Precious[Vahdat, 2000], right? Energy efficiency alone may not be enough Consider the architecture of a storage device Low power write buffer Power hungry perm. writes Policy w/ Energy Efficient Management: 1. Put the disk to sleep 2. Fill the low power write buffer 3. Dump write buffer all at once, in a bursty fashion What if renewables are available during the sleep? A Renewable-Aware Policy 1. Put the disk to sleep 2. Fill the low power write buffer 3. Dump write buffer whenever renewable energy is available If write buffer fills and no renewables are available, do we fall back to energy efficiency? Slide 6

Outline Studying the Impact of Intermittency Model of a wind-powered datacenter Effect on wind energy production Use of renewable energy in the datacenter Managing Renewables at the Request Level Conclusion Slide 7

Intermittency 1. Datacenter Model 2. Wind Intermittency 3. Renewables in the DC Approach Understand the flow of power through a datacenter Power sources, e.g., the Grid or a renewable energy Power-transfer devices, e.g.,, PDU Power consuming equipment Identify parameters that affect the use of intermittent power from renewable sources Assess the impact of these parameters Slide 8

Intermittency 1. Datacenter Model 2. Wind Intermittency 3. Renewables in the DC Battery Backup Power Transfer System Grid Energy Off-grid renewables STS/ UPS 1 MW Primary Secondary Output 1 MW peak Power transfer system: Input: K High voltage, turbulent AC streams Output: N high-quality power streams to N compute devices Slide 9

Intermittency 1. Datacenter Model 2. Wind Intermittency 3. Renewables in the DC Automatic transfer switch () Input 2 power sources, Outputs 1 power source Prevents dangerous backfeed between sources Only one source is active at a time Here's how it works Primary Secondary Output 1.Monitors power from the primary source 2.When power from primary dips below K, switches (with no detectable delay) to secondary 3.When primary exhibits K power for K' seconds, switches back to primary Slide 10

Intermittency 1. Datacenter Model 2. Wind Intermittency 3. Renewables in the DC Key parameters related to the Power-transfer threshold Power level where switches to the secondary source For dependability, threshold equals peak consumption For high use of renewables, set the threshold low Average power consumption of the datacenter When renewables are available In relation to the power-transfer threshold Research challenges: Usefully increase power density (i.e., do more work) without degrading performance Slide 11

Intermittency 1. Datacenter Model 2. Wind Intermittency 3. Renewables in the DC Goal: Understand impact of 1. power-transfer threshold 2. power consumption Battery Backup Power Transfer System Approach: Simulate the behavior of the under different datacenter consumption scenarios Grid Energy STS/ UPS Challenge: Intermittency Renewable Sources We used traces from National Renewable Energy Lab Off-grid renewables 1 MW Primary Secondary Output 1 MW peak 10 min. snapshots of power production at turbines in MT and CA Normalized to a 1MW turbine Site Time Avg. Power(MW) MT 12:10am 3.0 MT 12:20am 2.9 Slide 12

Intermittency 1. Datacenter Model 2. Wind Intermittency 3. Renewables in the DC How precious are renewables? Plot intermittent outages and continuous power Battery backup too costly But enough continuous supply for renewable-aware management Some power production 42% of the time for MT turbine Peak power 25% of the time Peak renewables are 40% percent more precious Prob. for 10 min-width bins Prob. for 10 min-width bins 50% 25% 8 MWh / 200 Wh/kg LI = 40000 kg LI or ~$3mil [wikipedia, Lithium Ion] 0% 10 100 300 >500 50% 25% MT Turbine- No Production (outages) Duration (minutes) MT Turbine- Cont. Power Production 0% 10 100 300 >500 Duration (minutes) Slide 13

Intermittency 1. Datacenter Model 2. Wind Intermittency 3. Renewables in the DC NREL data provided input to our datacenter model Metric: Renewable energy used MT produced 3.5M KW-hours of renewables and CA produced 2.3M KW-hours (black line) Power-transfer threshold = peak power KWh x 10 6 4 Powered by the MT wind turbine 3 2 1 0 100 KW 400 KW 700 KW Average Power Consumption Power-transfer threshold = zero 1MW Power-transfer threshold caused up to 65% drop Zero power-transfer threshold complicates the benefits of increased consumption KWh x 10 6 3 Powered by the CA wind turbine 2 1 0 100 KW 400 KW 700 KW Slide 14

Intermittency 1. Datacenter Model 2. Wind Intermittency 3. Renewables in the DC Metric: Cost per KW-hour Average price for commercial electricity $0.10 KW-hour $2.4M to erect a wind turbine that is connected (directly) to a datacenter [European Wind Energy Assc.] $1.6M installation 2% annual maintenance fees Lifetime of turbine: 20 years Datacenter at CA or MT could use 24M KWh Either high power consumption or zero threshold Wind-powered datacenter in MT: $0.04 KWh Slide 15

Outline Studying the Impact of Intermittency Managing Renewables at the Request Level Request-Level event profiling [shen-asplos-2008] Event-driven power modeling [bellosa-ew-2000] Energy and Power Characteristics of Requests Load balancing scenario Conclusion Slide 16

Managing Renewables 1. Request Characteristics 2. Scenario 3. Future Work Prev. section: MT wind-powered Datacenter with high average power consumption (when renewables are available) can potentially reduce costs to $0.04 Kwh Idea: Use request-level management to increase power consumption when only renewables are avaialable Route more requests to datacenters with unused renewables Delay long-running Map-Reduce requests Need mechanism to predict power/energy consumption of a request Slide 17

Managing Renewables 1. Request Characteristics 2. Scenario 3. Future Work Request workloads executed in isolation WattUp power meter measures watts and joules Processor was not adjusted during tests Disk accounted for as static consumption Another case for energy proportional servers Slide 18

Managing Renewables 1. Request Characteristics 2. Scenario 3. Future Work Consider 2 futuristic datacenters Power Transfer System Server power is energy proportional 1 datacenter uses renewable energy Power monitoring system notifies when precious renewables are available STS/ UPS STS/ UPS 50% peak power util. 0.5 0.5 Load Balancer Load balancer increases the renewablepowered datacenter's workload Challenges Uses request power models as guidance DCs connected by hard-to-change DNS Need optimization procedures [K. Le-HotPower-2009] Power Transfer System STS/ UPS STS/ UPS 50% peak power util. 40% peak power util. 70% peak power util. 0.2 0.8 Load Balancer Slide 19

Managing Renewables 1. Request Characteristics 2. Scenario 3. Future Work Our ongoing research is on the design, management, and mechanisms that will increase the use of precious renewables in the datacenter 1. Study trade offs in the configuration of the power-transfer system, i.e. s, PDUs, and UPSs Amount of precious renewables transferred to compute equip. Brownouts Practicality space, cost, and increment-ability 2. Study load balancing policies with renewable-aware mechanisms e.g., per-request vs. per-session round robin, feedback based Redirection speed for intra- and inter-datacenter workload Slide 20