ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Similar documents
MC 11 EB-2 Power supply cabinet with external bus, AC version

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

User Guide Automatic Transfer Switch (ATS)

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

Pulsar EXtreme 2000/3000 VA

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Installation Manual for D1800 Series High Power PoE Midspan Power Supply

ALPHA Automated Transfer Switch Operating Manual. Rev 1.21 The original of this document is drawn up in English language

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

Uninterruptible Power Supplies

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

TECHNICAL DESCRIPTION

RT4F-120V/20A-WAC RECTIFIER

MODEL 805 USER MANUAL

MAJOR VA Power Inverter

Hardened PoE Ethernet Switch

Installation Job Aid for Ethernet Routing Switch 3600 Series

VFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative

UPS Emergency Bed Power Unit

Chloride CROSS Rack 16 A, 32 A and 63 A

RECTIFIER PSR380 (48V VERSION) USER MANUAL UM_PSR380_48V_E_R1.0

RT4F-110V/25A RECTIFIER

CompactPCI SYSTEM POWER SUPPLIES. CPCI SERIES 150 to 350 Watts, Ac Input with PFC DPCI SERIES 150 to 350 Watts, 48 Vdc Input FEATURES:

Broadband Automatic Disconnect Switch. User Manual

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

Product Specifications

OV-MCR116. Media Converter Chassis System. User s Manual

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

QUINT-BUFFER/24DC/24DC/40

External level devices for conductive point level switch

PowerValue 31/11 T 10/20 kva User Manual

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

icore Kiosk system Installation Guide

THOR Modular. Modular UPS system. Online double-conversion Scalable Decentralized Parallel. Modular. 10, 20, 30, 40kVA modules kVA systems

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

AC-DC Converter REC K10

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

Switched Mode Power Supply Operating manual PAP800

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

High Power over Ethernet Midspans PD Port Model PD Port Model

Auto-Transfer Rack Power Distribution Unit

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Table of Contents. Safety. Attention. Warnings

A0750 AC-DC POWER MODULE

PCT2000. User Manual. Precision current transducer 2000 A

RT4B-110V/12A RECTIFIER

TRC-190 User s Manual

Model 7705 Control Module

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

BS 217 DUAL CHANNEL MASTER STATION USER MANUAL

Laboratory Switch Mode Power Supply Series. Instruction Manual

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity

CAN enabled The retifier can be monitored and controlled through analogue signals. It is also equipped with a CAN signal bus.

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

Hardened Media Converter

DMC-1000 Chassis-Based Media Converter

USER MANUAL. Frequency Converter 15kVA 3x200V 400Hz Type AC/AC Frequency Converter

SLI 15 INVERTER SERIES, 1500 W

The TSL Tally and UMD Configuring Program. Power Supply PSU-22 this section is intended to be read in conjunction with the Introduction

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

Safegard V4 Panel. Installation Datasheet. Safegard V4 Panel Installation Instructions and Datasheet release 1.7 August 2016

MINI-PS AC/10-15DC/8

EMC1600 Series Media Converter and Ethernet Extender Chassis

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

Premium Online Series

SFP450-12BG AC-DC Front-End Data Sheet 12V Output, 450 Watts

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Technical Manual Nova: Cabinet Security Management System (CSMS)

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER

SoundwebTM. Installation Guide

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ALL PSU Ltd ROTATION+ 6kVA - 10kVA PARALLEL ON LINE DOUBLE CONVERSION

RT4F-48V/50A-WAC RECTIFIER

Eaton 9PX PowerPass Distribution Modules and Transformers 9PXTFMR5, 9PXPPDM2, 9PXTFMR11, and 9PXPPDM1 User's Guide

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

BIPOLAR OPERATIONAL POWER SUPPLY

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

CUS150M1 Instruction Manual

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

Transcription:

ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318

SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16 HV can be operated in the 1 phase mains. The device is in compliance with all relevant safety regulations concerning information technology equipment, including electronic machines for use in an office environment. Warning The User or Operator may intervene in the operation of the ATS-16 HV provided that the instructions laid out on below connection. The Installation of the ATS-16 HV may only be carried out by qualified technical personnel. Even when all switches and interrupters are open, hazardous voltages are present within the ATS-16 HV; any operation that requires cases to be opened and/or removed may be carried out by authorized technical personnel only. ATS-16 HV User Manual 2

Safety notices Danger Carefully read the following safety notices! Failure to observe the instructions may danger your life, your health, the reliability of your device or the security of your data. Transport the unit only in suitable packaging. If the equipment is moved from a cold environment to the operating room, condensation may occur. Before you switch on the equipment it must be absolutely dry. The equipment must be installed in accordance with the environment conditions specified as, Operating temperature: 0 to 40, Operation humidity: 20% to 85% (no condensing). ATS-16 HV devices are not intended to operate with isolated neutral. Neutral connector must be present. Lay all cables so that nobody can stand on them or trip over them. For pluggable equipment, the socket-outlet shall be installed near the equipment and shall be easily accessible. The plug on the power supply cord is intended to serve as the disconnecting device. Make sure that no objects get inside the device. Do NOT connect equipment that will overload the ATS-16 HV. (for example: laser printers). The sum of the leakage currents of the ATS-16 HV does not exceed 3.5mA. Earth connection is essential for ATS-16 HV before connection supply. Data transmission lines should NOT be connected or disconnected during a thunderstorm. Emergency Danger The supply to the load may be interrupted by opening all the switches. DO NOT use WATER to extinguish any fires that may occur in the area in which the ATS-16 HV is installed. Radio Interference The ATS-16 HV is a Radio Interference Class C1 product (IEC62310-2). The device may cause radio interference. DO NOT place it near devices which are especially susceptible to electromagnetically interference. Repackaging DO NOT remove air from the packaging. ATS-16 HV User Manual 3

OPERATING INSTRUCTIONS Introduction This manual contains information regarding the installation, operation and use of the ATS-16 HV. It is advised that this User Manual be consulted before installation of the equipment, which operation shall only be carried out by qualified personnel. Device Overview The ATS-16 HV is available voltage level 220/230/240Vac, Nominal current: 16Amp. PREPARATION FOR USE Delivery and Storage The goods have been checked thoroughly before dispatch. On receipt check the packaging and ensure that the contents are undamaged. Any damage or missing parts must be reported to the supplier as soon as possible. Inventory List ATS-16 HV module 2 pluggable input power cable (p/n: 108-00140-xx) Bracket kits (for rack mounting and vertical mounting) NOTE: 1. An approved power cord greater or equal to H05VV-F, 3G, 0.75 mm 2 must be used. 2. User Manual will be file sending only, not make printing and put it in accessory kit. Storage Storage temperature:-25 to 70, Storage humidity: from 10% to 90%. Handling The equipment must be handled with care, damage may be caused if dropped or subjected to severe impact. Environmental Conditions The ATS-16 HV must be installed as rack mount or on a level and even surface and in an area protected from extremes of temperature, water and humidity and the presence of conductive powder or dust. DO NOT stack units and do not place any objects on top of a unit. ATS-16 HV User Manual 4

Rack Mounting Taking into consideration to mount the ATS-16 HV into a cabinet, it is necessary that chosen cabinet be capable of supporting the unit with corresponding rails or angels. ATS-16 HV scope of supply contains two angels for fixing the ATS-16 HV into a 19 inch rack or into a cabinet with 19 inch inner design. Also ATS-16 HV vertical mounting is possible. Dimensions of area It is necessary to leave a minimum space of a few centimeters around right side, left side and rear side to allow a flow of air and to provide access to interface. ATS-16 HV User Manual 5

INSTALLATION Configuration of the ATS-16 HV system The ATS-16 HV provides high reliability supply by switching the load to one of two possible power suppliers. Primarily these two supplies are UPS devices with sinusoidal output only. These UPS must operate with double conversion principle. Technical Data Block Diagram ATS-16 HV User Manual 6

ATS-16 HV Technical Data Input features Item Specification Remark Nominal input voltages 230 Volts Default: 230Vac (220/230/240 selectable) Working range 160 ~ 290Vac Input voltage acceptance window Nominal voltage +/- 12% ~ +/- 20% Input voltage low comeback Input voltage low loss volts +10V Input voltage high comeback Input voltage high loss volts -10V Adjustable (Default: +/- 12%) Nominal current 16 Amp Nominal frequency 50/60Hz selectable Input frequency range Nominal frequency +/- 15%. Output features Items Specifications Remark Output voltage Same as input voltage Output frequency Same as input (50 /60 Hz) Output current 16 Amps Max. transfer time 15m second Interface Items Specifications Remark Inlet IEC 320-C20x 2 Power Cord: p/n 108-00140-xx Outlet IEC 320-C19 x 1 IEC 320-C13-3 x2 EPO active Output NOT supplied. ATS-16 HV User Manual 7

Communications: A. RS232 (DB-9, pin type) PIN No. PIN 2: PIN 3: PIN 5: Definition RX TX GND B. Dry Contact (DB-9, pin type) Pin No. Description Open State Close State Pin 1 Over temperature signal Normal Over Temperature Pin 2 Not used Pin 3 Not used Pin 4 Source 1 status signal Source 1 is fail Source 1 is ok Pin 5 Common Pin 6 Not used Pin 7 Over load signal Normal Over load Pin 8 Source 2 status signal Source 2 is fail Source 2 is ok Pin 9 Summary alarm signal Normal Alarm occurred Mechanical Features Items Specification Remark Dimension W = 430mm D = 315mm H = 44mm (1U) Weight Approx. 8kg Packaging sizes W = 585mm D = 425mm H = 184mm Color Silver RAL 9006 Material Structure Metallic Case Rack Mount Unit (1U) Vertical mount (0U) ATS-16 HV User Manual 8

Environment Items Specifications Comments Operating temperature 0 to 40 C Storage temperature -25 C to 70 C Continuous Storage humidity 10% to 90% Operation humidity 20%to 85% No condensing Operation Altitude 1000m Audible noise 25dBA (max.) Buzzer OFF Cooling Natural Cooling IP Protection IP 30 Safety Standards Meet IEC60950-1. EMC Standard: EMI IEC62310-2, C1 IEC61000-4-2 level 3 IEC61000-4-3 level 2 (Lab.) IEC61000-4-4 level 2 EMS IEC61000-4-5 level 3 IEC 61000-2-2 LF Immunity IEC61000-4-6 level 2 (Lab.) IEC61000-3-2 Harmonic (Lab.) IEC61000-3-3 Flicks ATS-16 HV User Manual 9

Overload Capability: External Protection and Isolation Devices External devices for the protection of cables and for isolating the ATS-16 HV and UPS external to the devices shall be installed upstream and downstream of the equipment. Select and configure the isolating device upstream according with ATS-16 HV MCB input 16Amp breakers. Disconnecting devices must be provided in building installations and other locations. All protection devices (circuit breakers and fuses) placed upstream of the ATS-16 HV input and downstream to ATS-16 HV output line have to be installed by the personnel for the protection of both the cables and the equipment and in coordination with both ATS-16 HV input protection (fuses) and ATS-16 HV overload capacities. WARNING If ATS-16 HV overload capacities are overcome the unit will unsupplied the output load. Depending on overload characteristic the ATS-16 HV either will trip the input fuses or drive only internal power relays to the open position. ATS-16 HV User Manual 10

Front Panel The following figure shows the front of the ATS-16 HV with its LED display, interfaces. Rear Panel The following figure shows the back of the ATS-16 HV with its connectors, terminals and interfaces. ATS-16 HV User Manual 11

Operating Panel In the following figure you can see the front panel of the ATS-16 HV. Most functions of the ATS-16 HV are driven by an internal control. From the operating panel a priority setting can be made to prefer a mains source. The state of the relay group is displayed with several LEDs. Please see more detail operation information in following table. ATS-16 HV User Manual 12

Description of the system The 2-pole ATS-16 HV is a two ways, single phase automatic switch powered by two independent synchronous or asynchronous AC power supply sources. The ATS-16 HV makes a rapid switch from one source to the other in the event of a fault to the power supply used to power the load. One of the two sources can be designated as the preferred power supply, to which the ATS-16 HV will transfer the load. It remains there until different designations or faults require it to be switched to the other source. The ATS-16 HV is fitted with a block diagram with LED indicators, capable of providing all information concerning equipment operation status, together with the power source priority selection button BP2 enable trained operators to make full use of the apparatus. Features: - Break Before Make transfer mode. - Back feed protection (according EN62310-1). - Complete protection for overload and short-circuit. (With FUSE Holder Accessible). - Redundant power supply. (From input Source 1 and Source 2). - AC source detection (voltage and current detection). - Output detection (current detection). - LED display. - EPO contact is integrated - Different setting to adjust the voltage failure sensing level (+/- 12% ~ +/- 20%). (Default setting: Nominal voltage +/- 12%). - Protection: IP30. - ON/OFF for Buzzer - Selectable Nominal Frequency - RPO active (open): output not supplied. ATS-16 HV User Manual 13

Manual Switch ON Procedures First Switch on from Source A Check that all switches are OFF and check the EPO status. Input the mains for source A. Wait for several seconds until the logic is enabled and the LEDs on the display are switched ON. - Priority LED PS1 or PS2 depending on the default setting. - LED S1 - LED SW1 Input the mains for source B. The following LEDs are illuminated: - Priority LED PS1 or PS2 depending on the default setting. - LED S1 - LED S2 - LED SW1 or SW2 according to the primary source First Switch on from Source B Check that all switches are OFF and check the EPO status. Input the mains for source B. Wait for several seconds until the logic is enabled and the LEDs on the display are switched ON. - Priority LED PS1 or PS2 depending on the default setting. - LED S2 - LED SW2 Input the mains for source A. The following LEDs are illuminated: - Priority LED PS1 or PS2 depending on the default setting. - LED S1 - LED S2 - LED SW1 or SW2 according to the primary source Switch OFF Warning When this procedure is carried out the load is no longer supplied by the ATS-16 HV. ATS-16 HV User Manual 14

Troubleshooting If problems should occur, please check the following points before contacting the responsible customer service representative: Is the mains voltage present at the ATS-16 HV input? Has one of the two input fuses tripped or open? If you contact the responsible customer service representative, please have the following information ready: Device information (model name and serial number) An exact description of the problem (what loads are being operated, does the problem occur regularly or sporadically, etc.) Rectification of errors: Problem Possible Cause Measure No display, no alarm. Both mains indicator S1 and S2 do not illuminate, when mains voltage present. Alarm indicator F1 illuminates, acoustic alarm active with 0.5 second sequence. Mains or feeding UPS units switched off. No mains voltage present. Input fuses tripped. Both input fuses tripped. ATS-16 HV Fault. EPO Overheating Switch on the mains or feeding UPS units. Have mains inspected by qualified electrician. Check and make sure the load capacity within the specification, then replace a good fuse. If the problem persists, contact the responsible customer service representative. Check and make sure the load capacity within the specification, then replace a good fuse. If the problem persists, contact the responsible customer service representative. Contact the responsible customer service representative. Check all loads and solve (clear) the problem that caused the EPO. Check and make sure the load capacity within the specification, or decrease ambient temperature (less than 40 ). ATS-16 HV User Manual 15

Service Address ATS-16 HV User Manual 16