Automatic Subthalamic Nucleus Targeting for Deep Brain Stimulation. A Validation Study

Similar documents
IMAGE registration has become a common and useful tool

Leksell SurgiPlan Overview. Powerful planning for surgical success

Image Registration I

Leksell SurgiPlan. Powerful planning for success

Nonrigid Registration using Free-Form Deformations

Segmentation of 3D CT Volume Images Using a Single 2D Atlas

Non-rigid Image Registration

ECSE 626 Project Report Multimodality Image Registration by Maximization of Mutual Information

Distance Transforms in Multi Channel MR Image Registration

Medical Image Analysis

OnDemand3D Fusion Technology

Non-Rigid Registration of Medical Images: Theory, Methods and Applications

Advanced Visual Medicine: Techniques for Visual Exploration & Analysis

Non-Rigid Registration of Medical Images: Theory, Methods and Applications

A Method to Correct for Brain Shift When Building Electrophysiological Atlases for Deep Brain Stimulation (DBS) Surgery

Non linear Registration of Pre and Intraoperative Volume Data Based On Piecewise Linear Transformations

Atlas Based Segmentation of the prostate in MR images

Whole Body MRI Intensity Standardization

Efficient population registration of 3D data

2D-3D Registration using Gradient-based MI for Image Guided Surgery Systems

Non-rigid Image Registration using Electric Current Flow

Multi-Modal Volume Registration Using Joint Intensity Distributions

Spatio-Temporal Registration of Biomedical Images by Computational Methods

3D Surface Reconstruction of the Brain based on Level Set Method

Neurosurgery for functional disorders guided by multimodality imaging

Basic principles of MR image analysis. Basic principles of MR image analysis. Basic principles of MR image analysis

A Generic Framework for Non-rigid Registration Based on Non-uniform Multi-level Free-Form Deformations

Intraoperative Prostate Tracking with Slice-to-Volume Registration in MR

Adaptive Local Multi-Atlas Segmentation: Application to Heart Segmentation in Chest CT Scans

Assessing Accuracy Factors in Deformable 2D/3D Medical Image Registration Using a Statistical Pelvis Model

PROSTATE CANCER DETECTION USING LABEL IMAGE CONSTRAINED MULTIATLAS SELECTION

Automatic MS Lesion Segmentation by Outlier Detection and Information Theoretic Region Partitioning Release 0.00

Imaging protocols for navigated procedures

Anomaly Detection through Registration

Non-Rigid Multimodal Medical Image Registration using Optical Flow and Gradient Orientation

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

2 Michael E. Leventon and Sarah F. F. Gibson a b c d Fig. 1. (a, b) Two MR scans of a person's knee. Both images have high resolution in-plane, but ha

Image Registration. Prof. Dr. Lucas Ferrari de Oliveira UFPR Informatics Department

Automatic Construction of 3D Statistical Deformation Models Using Non-rigid Registration

Rigid and Deformable Vasculature-to-Image Registration : a Hierarchical Approach

Biomedical Image Analysis based on Computational Registration Methods. João Manuel R. S. Tavares

Department of ECE, SCSVMV University, Kanchipuram

Hybrid Spline-based Multimodal Registration using a Local Measure for Mutual Information

FROM IMAGE RECONSTRUCTION TO CONNECTIVITY ANALYSIS: A JOURNEY THROUGH THE BRAIN'S WIRING. Francesca Pizzorni Ferrarese

Transforming Datasets to Talairach-Tournoux Coordinates

Supplementary methods

Chapter 3 Set Redundancy in Magnetic Resonance Brain Images

Fast Free-Form Deformation using the Normalised Mutual Information gradient and Graphics Processing Units

Automatic Generation of Shape Models Using Nonrigid Registration with a Single Segmented Template Mesh

A Study of Medical Image Analysis System

Computational Medical Imaging Analysis Chapter 4: Image Visualization

Coupled Bayesian Framework for Dual Energy Image Registration

Medical Image Registration by Maximization of Mutual Information

Atelier 2 : Calcul Haute Performance et Sciences du Vivant Forum er juillet, Paris, France

Ischemic Stroke Lesion Segmentation Proceedings 5th October 2015 Munich, Germany

Quantitative Study of Brain Anatomy

Reproducibility of interactive registration of 3D CT and MR pediatric treatment planning head images

Using K-means Clustering and MI for Non-rigid Registration of MRI and CT

Non-rigid registration methods assessment of 3D CT images for head-neck radiotherapy

Deformable Registration Using Scale Space Keypoints

A Review on Label Image Constrained Multiatlas Selection

Integrating spatially resolved 3D MALDI imaging mass spectrometry with in vivo MRI

Parallel Non-Rigid Registration on a Cluster of Workstations

MR-Guided Mixed Reality for Breast Conserving Surgical Planning

Fiber Selection from Diffusion Tensor Data based on Boolean Operators

Annales UMCS Informatica AI 1 (2003) UMCS. Registration of CT and MRI brain images. Karol Kuczyński, Paweł Mikołajczak

Automated Segmentation and Reconstruction of the Subthalamic Nucleus in Parkinson s Disease Patients

Correspondence Detection Using Wavelet-Based Attribute Vectors

HST.582J / 6.555J / J Biomedical Signal and Image Processing Spring 2007

Automatic Vascular Tree Formation Using the Mahalanobis Distance

Medicale Image Analysis

Medical Image Registration

Nonrigid Registration with Adaptive, Content-Based Filtering of the Deformation Field

Retrospective Evaluation of Inter-subject Brain Registration

Automatic Registration-Based Segmentation for Neonatal Brains Using ANTs and Atropos

Retrospective evaluation of inter-subject brain registration

The Insight Toolkit. Image Registration Algorithms & Frameworks

Interactive Deformable Registration Visualization and Analysis of 4D Computed Tomography

Cortical Surface Registration Using Texture Mapped Point Clouds and Mutual Information

A Pyramid Approach For Multimodality Image Registration Based On Mutual Information

Supplementary Information

Automatic Segmentation of Parotids from CT Scans Using Multiple Atlases

A Binary Entropy Measure to Assess Nonrigid Registration Algorithms

An Introduction to Statistical Methods of Medical Image Registration

THE geometric alignment or registration of multimodality

Transitive and Symmetric Nonrigid Image Registration. Yi-Yu Chou

Attribute Similarity and Mutual-Saliency Weighting for Registration and Label Fusion

Automatic segmentation of the cortical grey and white matter in MRI using a Region Growing approach based on anatomical knowledge

VETOT, Volume Estimation and Tracking Over Time: Framework and Validation

Knowledge-Based Deformable Matching for Pathology Detection

Lucy Phantom MR Grid Evaluation

QuickNII Workflow/User guide

Machine Learning for Medical Image Analysis. A. Criminisi

Prototype of Silver Corpus Merging Framework

An independent component analysis based tool for exploring functional connections in the brain

Free Form Deformations Guided by Gradient Vector Flow: a Surface Registration Method in Thoracic and Abdominal PET-CT Applications

Role of Parallel Imaging in High Field Functional MRI

Multi-Atlas Segmentation of the Cardiac MR Right Ventricle

Utilizing Salient Region Features for 3D Multi-Modality Medical Image Registration

A Method of Automated Landmark Generation for Automated 3D PDM Construction

Transcription:

Automatic Subthalamic Nucleus Targeting for Deep Brain Stimulation. A Validation Study F. Javier Sánchez Castro a, Claudio Pollo a,b, Jean-Guy Villemure b, Jean-Philippe Thiran a a École Polytechnique Fédérale de Lausanne (EPFL), Signal Processing Institute, Lausanne, Switzerland b Department of Neurosurgery, Centre Hospitalier Universitaire Vaudois (CHUV), Lausanne, Switzerland Abstract In functional stereotactic neurosurgery, one of the cornerstones upon which the success and the operating time depends is an accurate targeting. The subthalamic nucleus (STN) is the usual target involved when applying Deep Brain Stimulation (DBS) for the Parkinson s disease (PD). Unfortunately, STN is usually not clearly visible in common medical imaging modalities, which justifies the use of atlas-based segmentation techniques to infer the STN location. We propose a scheme that allows both, to perform a comparison between different non-rigid atlas registration algorithms and to evaluate their usability to locate the STN automatically. Using our validationevaluation scheme and accurate registration algorithms we demonstrate that automatic STN localization is possible and accurate. Key words: targeting Non-rigid registration, atlas-based segmentation, deep brain stimulation, surgical planning, pre-operative 1. Introduction A typical DBS procedure starts with the placement of the stereotactic head frame, fixed to the patients skull, that will be used as a coordinate reference. Next an imaging study is taken in order to select the target to stimulate and to plan the trajectories for introducing the electrodes. Usually two kinds of images are taken to be able to visualize different tissues, MR T1-weighted and MR T2-weighted images. The localization of the STN target is performed on coronal T2-weighted images acquired perpendicularly to AC-PC axis and crossing the anterior limit of the Red Nucleus. A study of STN targeting using visible anatomical landmarks can be found in [1]. Then the target coordinates are reported to the T1-weighted image where trajectories are planned. Once in the operating room the head frame is fixed to the operating Email address: francisco.sanchezcastro@epfl.ch (F. Javier Sánchez Castro). Preprint submitted to Elsevier Science 17 March 2005

table, a small hole is drilled into the patient s skull according to pre-operative trajectories. Because of the difficulty to see the STN directly from medical images, the pre-operative target is only an estimation of the real location. The electrode s location has to be adjusted intra-operatively using electrophysiological recordings and from stimulation tests. The goal of the study reported in this paper is to sound the possibility of automatically locate the STN using existing registration techniques and to compare their performance and usability. Knowing the location of the STN for all our patient s database, a patient is chosen as atlas and each individual patient mapped back to the atlas using the registration methods considered in this study to obtain an estimation of the STN which is compared to the real location given by the expert. 2. Material and Methods 2.1. Data For each patient of our bilaterally implanted parkinsonian patient s database two kinds of images were taken pre-operatively: a 3D T1-weighted magnetization-prepared rapid acquisition gradient echo (MPRAGE) MRI sequence (Siemens Vision R, 1.5T, Erlangen, Germany) TR 9.7 ms, TE 4 ms, number of slices/slice thickness: 164/1.40 mm, FOV 280x280, matrix 256x256, pixel size 1.09x1.09 mm, and few coronal slices (due to the time taken for this kind of imaging sequence) of an inversion recovery (IR) T2- weighted, TR 2,560 ms, TE 4 ms,number of slices/slice thickness: 7/3 mm, FOV 300x300, matrix 512x512, pixel size 0.59x0.59 mm. Taking profit from the fact that in some rare cases the STN is visible in MR T2-weighted images, a reference can be constructed and used as a ground truth. To do this neurosurgeon experts have been asked to select patients with clearly visible STN in MR T2-weighted images amongst our patient s database. After exhaustive inspection 8 patients were selected (16 STNs). 2.2. Validation Scheme An experimented neurosurgeon with wide experience in PD surgery and targeting has been asked to click the target point (2 STN) for each selected T2 series. This process has been repeated 5 times for each patient at different days to avoid that the expert be influenced by previous targeting choices. With this data we were able to compute a statistical mean target point coordinates which we call the real targets. Amongst the 8 subjects selected, the one with the most clearly visible STN has been selected as a reference subject, both for the right and left sides. Intra-expert variability statistics can also be extracted. Using these data we can consider our reference subjects as an atlas. Then, by non-rigidly registering the atlas with the patient image, we obtain an estimation of the STN position in the patient. The procedure is as follows. The first step is, for each patient, to report its MR T2 coordinates to MR T1 coordinates to obtain the location of the real targets in the T1 domain. To do this a rigid registration between the two modalities (6 degrees of freedom: translation and rotation) has been performed [2]. The next step consists in applying each of the registration algorithms under study to get an estimation of the position of the STN. This estimation is obtained by registering the MR T1-weighted image of the atlas with the MR T1-weighted image of the patient under study. In this work four methods were considered (see section 2.3). Finally, repeating this for the 7 datasets (14 STNs) involved in this study, Euclidean distances from estimated to real targets (seen as the mean target point given by the expert) for each STN are calculated and statistics are extracted to evaluate the performance of the different methods. 2

2.3. AC-PC Targeting and Registration Algorithms To face up to image registration the following methods have been tested: Atlas-based (AC-PC) targeting. AC-PC referential together with brain atlases is one of the methods used to target the STN in medical environment, mainly when STN is not clearly visible in MR T2-weighted images which is the usual case. Neurosurgeons have to locate the anterior and posterior commissures (AC-PC points). Then, using a stereotaxic atlas and taking as the origin the midcommissural point (MCP), we can estimate that the STNs are located at coordinates (following Schaltenbrand-Wahren [3]): anteroposterior (AP) 3mm, lateral (LAT) ±12mm (left and right side) and vertical (VERT) 4mm. Affine registration. It is an independent implementation based on the work of Maes et al. [2]. The 12 parameters are optimized in order to maximize the mutual information between the images to be registered [4]. Affine registration is also used as a pre-alignment step for non-rigid transformations described below. Demons algorithm. It is an independent implementation of the intensity-based algorithm developed by Thirion which uses the Maxwell s demons concept [5]. B-splines algorithm. It is a mutual-information-based free-form deformation algorithm which displacement field is modelled as a linear combination of B-splines lying in a regular grid (uniformly spaced control points). See [6] as a reference of registration using splines. 3. Results 3.1. Target Selection and Surgeon Variability Two main statistics can be extracted from the data given by the expert: intra-surgeon variability and the mean target point coordinates for each STN which will be used as a real target coordinates. In order to evaluate the repeatability of the neurosurgeon targeting we have proceeded in different manners. First we have computed, for each STN, the Euclidean distance between each couple of neurosurgeon s clicks (5 clicks per STN, 10 distances per STN, 160 distances for the eight selected patients from the database) and we obtain a mean and a standard deviation (using the unbiased estimator) of 1.67 ± 0.98mm, which we call paired variability. The same information can be extracted computing the centroid for each STN and calculating the Euclidean distances to each click. This gives a mean and unbiased standard deviation of 1.06 ± 0.61mm, which we call centroid variability. These quantities allow us to get an idea of the surgeon variability and its accuracy when clicking over the pre-operative target. If we only consider to the STNs used as a reference we obtain a paired variability of 1.64 ± 0.88mm and 1.18 ± 0.52mm, a centroid variability of 1.10 ± 0.32mm and 0.75 ± 0.38mm and a mean distance to the MCP of 12.38 ± 0.61mm and 13.63 ± 0.54mm for the left and right sides respectively. In figure 1 the points targeted by the expert for the left (figures 1(a), 1(b), 1(c)) and right (figures 1(d), 1(e), 1(f)) STNs chosen as a reference can be seen. For visualization purposes, each point is projected onto the three orthogonal planes passing through the centroid and showed using a circle (radius of 1mm). We can also decompose these distances in anteroposterior (AP), lateral (LAT) and vertical (VERT) coordinates which allows comparing directly the mean STN location for our database with usual STN coordinates from the atlases (e.g. [3]). In table 1 we show the mean and standard deviation of the coordinates referred to the MCP for the 16 STNs used in this study as well as their mean distance to the MCP. 3

(a) L-STN Coronal. (b) L-STN Sagital. (c) L-STN Axial. (d) R-STN Coronal. (e) R-STN Sagital. (f) R-STN Axial. Fig. 1. Reference STN expert targeting. Coordinates AP LAT VERT mean ± std 3.29 ± 1.36mm ±12.57 ± 1.39mm 3.16 ± 0.89mm MCP-distance 13.47 ± 1.37mm Table 1 Mean STN coordinates referred to the MCP. 3.2. Target Estimation and Assessment of the Methods The statistics (mean and unbiased standard deviation) of the errors committed when applying these algorithms and methods to locate the STN as described in 2.3 are shown in table 2. In order to compare the results statistical tests have been done. In figure 2 a statistical box plot for the different methods tested is showed. A paired T-test of the hypothesis that the errors come from distributions with equal means has been performed over each pair of methods at a 5% significance level. We obtain that the errors committed with B-splines, demons and AC-PC based methods are not significantly different. However the results show that affine registration is significantly different from the other methods (p values of 0.0469, 0.0270, and 0.0329 for the B-splines, demons and AC-PC methods respectively). In figure 3 we show the projection of each STN estimation (in white) onto the reference subject (in red) using the B-splines registration algorithm. Each point is represented by a circle of 1mm of radius whose coordinates are projected onto the reference subject point coordinates (in red) in order to visualize the points in each view and referred to the reference subject point. The estimated targets are located very close to the real target and forming tight clouds of points showing that this kind of automatic estimation 4

Table 2 Estimation Errors Methods mean ± std Affine 2.65 ± 1.25mm Demons 1.97 ± 0.85mm B-Splines 1.80 ± 0.62mm AC-PC 1.98 ± 0.81mm Fig. 2. Statistical box plot of the errors committed using different methods. is reliable and well suited for this application. (a) L-STN Coronal. (b) L-STN Sagital. (c) L-STN Axial. (d) R-STN Coronal. (e) R-STN Sagital. (f) R-STN Axial. Fig. 3. STN estimation using B-splines. 5

4. Discussion and Conclusions The main conclusion one can extract from the results we have obtained from this evaluation-validation work is that automatic STN location is possible and accurate. As we can see, by simple inspection of the numerical results, the B-splines method shows the best performance with the smallest mean error and adjusted (unbiased) standard deviation but closely followed by demons and AC-PC methods. The points project on tight clusters showing the robustness of this kind of estimation method. The statistical tests have shown that global affine registration is not enough for our application and that there are not significant differences between the errors committed using the B-splines, Demons or AC-PC referential-based techniques. Although AC-PC referential-based method shows an acceptable performance its estimation needs AC and PC point s identification by an expert and does not take into account inter-patient variability, which is very important at a single patient level. The fact that AC-PC shows such a good behavior can be explained because the selected patients follow well the average brain defined by the atlas. But what about patients with abnormal anatomy or damaged brains? Although the choice of the STN of reference can influence the results, the methods have been tested using 6 different combinations of STN-pairs (left and right references) and the results were similar. The automatic estimation of the STN can be also used as a first and fast pre-operative target estimation that can be refined by the neurosurgeon criterion. As our patient s database increases and more experts included in the study, we will be able to establish stronger assessments and conclusions. Acknowledgements This work is supported by the Swiss National Science Foundation under grant number 205320-101621. References [1] C. Pollo, R. Meuli, P. Maeder, F. Vingerhoets, J. Ghika, J-G. Villemure, Subthalamic Nucleus Deep Brain Stimulation for Parkinson s Disease: Magnetic Resonance Imaging Targeting Using Visible Anatomical Landmarks, Proceedings of the Meeting of the American Society for Stereotactic and Functional Surgery, New York, vol. 80, no. 1-4, 2003. [2] F. Maes, A. Collignon, D. Vandermeulen, G. Marchal, P. Suetens, Multimodality image registration by maximization of mutual information, IEEE transactions on Medical Imaging, vol. 16, no. 2, pp. 187-198, April 1997. [3] G. Schaltenbrand, W. Wahren, Atlas for Stereotaxy of the Human Brain, ed. 2, Stuttgart, Thieme, 1977. [4] P. Viola, Alignment by maximization of Mutual Information, M.I.T. Artificial Intelligence Technical Report, no. 1548, June 1995. [5] J.-P. Thirion, Image matching as a diffusion process: an analogy with Maxwells demons, Medical Image Analysis, vol. 2, no. 3, pp. 243-260, 1998. [6] D. Rueckert, L. I. Sonoda, C. Hayes, D. L. G. Hill, M. O. Leach, D. J. Hawkes, Nonrigid registration using Free-Form Deformations: Application to breast MR images, IEEE Transactions on Medical Imaging, vol. 18, no. 8, pp. 712-721, 1999. 6