ED-T7. External touch display, 7 inch. Function. Installation The display can be mounted, for example, on the operation panel of the control cabinet.

Similar documents
EXOcompact. Third generation freely programmable controllers

OP10. Pre-programmed, configurable controller for simple applications

EC-PU4. Processor unit with 4 communication ports

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

Pre-programmed room controller with display and communication

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

EXOcompact. Freely programmable controller

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

Corrigo E. Version 3.0 (ventilation), 3.0 (heating), 1.1 (boiler). Controllers for heating, boiler and ventilation applications in buildings.

DESIGO 30 Remote operator terminal. for more then one HVAC systems en. menu + esc

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Evolution TH. Pre-configured controller with display, clock and communication. Evolution. Applications. TH version. Sensors

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Room controller STRA-17

RWD32S Software Tool. Operating Instructions. CE1U3344en Building Technologies

Master room unit for RRV controllers

Room unit with PPS2 interface

RCF-230CTD. Built-in or external sensor The controller has a built-in sensor. Alternatively, the input for an external PT1000-sensor can be used.

7-day room temperature controller

Protocol interface AK-PI 200 REFRIGERATION AND AIR CONDITIONING. Manual

Room Temperature Controller

AIAS. Technical description

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

Room Temperature Controllers

Room Temperature Controller

Pre-programmed room controller with display and communication

ECL Comfort V a.c. and 24 V a.c.

7-day room temperature controller

Pneumatic precision pressure controller Model CPC6000

Electromotoric actuators

Semi flush-mounted room temperature controllers with LCD

UCU Room Display. Operation Modes. Features. Applications DATASHEET

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

Communication module to connect M-bus devices to POL6xx.xxx controllers.

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Product and Application Description

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

Electrical Actuators

MCX06C Programmable controller

Room unit with PPS2 interface

Mobile Data Collector

Semi flush-mounted room temperature controllers with LCD

ECL Comfort 296 controller and Remote Control Unit ECA 30 / 31

MAXDTC-BT Family User Manual

Network node WTT56.. A6V _en--_c Building Technologies

Zenith DS9000 Dispensing System

Electrical Actuators

AUTOMATION.CROUZET.COM 7 CROUZET TOUCH HMI AUTOMATION & CONTROL. New HMI. for & automation.crouzet.com

RТTH DUAL ROOM SWITCH

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

Touch screen operator unit

Electronic timer CT-ERD.12

Weekday / weekend room temperature controller

RXTP ROOM TEMPERATURE

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

BIOC3 V1 USER S MANUAL. Biometric Reader v. b1

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

Semi Flush-mount Room Temperature Controllers with LCD

Twinkler USB Interface User Guide & Reference

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

Temperature controller Ducted systems

Colour Touch Panel 3.5

Portable low-pressure controller Model CPC2000

Evo2. Free programmable room controller. Summary

RCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater

RXTH DUAL ROOM SENSOR / SWITCH

Local Control Network

1 PoolManager 5 Software Releases Overview

Priva Blue ID Relay output module DOR4/DOR8

Electromotive actuators for combi valves

HMIPWC7D0E01 Panel PC Optimum - Compact Flash - 15'' - DC - Fanless

Sauter Systems

Priva Blue ID Communication module RS232 SC22

Weekday / weekend room temperature controller

High-speed peumatic pressure controller Model CPC3000

Electromotoric actuator

Pneumatic precision pressure controller Model CPC6000

Features. Applications and Benefits TRC ELECTRONICS, INC

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

High Accuracy, Easy Operation for 2D Code Reading

GV-RK1352 and GV-R1352 Card Reader

GV-AS Controller. Installation Guide

8 10/100TX w/ 8 Booster PoE at/af Injector Industrial Switch

SmartX Living Space Sensors

M-Bus Central Unit. Use

Priva Blue ID Communication module RS485 SC44

DECS 2.0 Danfoss Energy Control System

Operation Guide CT100

Book ; Book TOC Page 1 Black Wednesday, 20 September :21. A publication of CDS electronics bv, Maassluis, The Netherlands

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

Allows detailed and easy monitoring and operation of VRV systems (maximum 2 x 64 groups / indoor units)

STRA-17 Room controller. Installation and maintenance manual. Content

TECHNICAL DESCRIPTION

Pneumatic precision pressure controller Model CPC6000

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

Air data test indicator Model CPA2501

Electronic timer CT-AHD.22

Transcription:

hto Revision 2017-11-01 External touch display, 7 inch is a touch screen display and configuration unit intended for connection to a controller. The display offers full control of controllers that are, for example, mounted inside of a cabinet. Capacitive touch display with high resolution Easy to use Connects to the display port on the controller Up to 8 rows of information can be displayed on the screen for some applications Display adapts automatically to the program Function can be used as an external touch display for various controllers. The display will automatically detect the controller s programming and display the correct information. It has a 7 inch, capacitive touch display with a resolution of 1024 x 600. Installation The display can be mounted, for example, on the operation panel of the control cabinet. It connnects to the controller by using Regin s cable EDSP-K3 or EDSP-K10. The display cable is connected to the controller using a 4P4C modular contact (see the diagram below, Wiring). Ignore all changes and go to next variable Erase the digit at the cursor. The cursor will move to next value when the current value is empty. In edit mode Blinking: Possible to edit Nothing on the screen is editable The alarm bell works as a button that will take you to the alarm list. No alarm buttons and icons There are some common touch buttons for all controller programs. Blinking: There are one or more unacknowledged alarm(s) There are one or more acknowledged alarm(s) E-Mail: info@regincontrols.com 1

For use with with Regin s EXOproducts The display can be used together with Regin s controllers EXOcompact, EXOclever and EXOdos, and the software tool EXOdesigner. Note: The controller must have the functions Display 6.0, Controller Handler 4.1 and Time Channels Display 1.2 (included in EXO 2017, ed. 1 or newer) in order to work with. When configuring the display in EXOdesigner, you can choose a large or a small program display size in the design tool. The large display can display 8 x 32 characters of data and the small 4 x 20 characters, for compatibility with existing display programs. Both display sizes have the same functionality and configuration. The buttons and interface are also the same, see above in buttons and icons. Note: We do not recommend to use the large program display size for together with controller models without TCP/IP (EXOcompact especially). Doing so will make the display menu very slow. with large program display with small program display E-Mail: info@regincontrols.com 2

For use with Regin s Exigo The display can be used together with Regin s controllers with the Exigo software. When the display is connected to a controller with Exigo 4.1 or higher, it will start up on the Exigo main page. A swipe to the left or right will change the screen to a controller display emulator. Revision 2017-11-01 Main page Depending on the configuration of the controller, the display shows up to 4 heating systems, 2 hot water systems, district heating system, boiler control, buffer tank and solar panel system. Mode - menu At the bottom on the main page there are five Mode buttons. When the button text is green, it means that the mode is activated. System Mode Heating system Domestic hot water system District heating / Boiler / Buffer / Solar Automatic mode, control function depending on timer and other settings Normal operation with setpoint Automatic mode, working on demand Same as Automatic mode No heating, which means switch off operation if in heating mode, and automatic operation in cooling mode Same as Automatic mode Same as Automatic mode Holiday operation with setpoint Holiday Same as Automatic mode No control function, valves closed, pumps off. Not accessible from the display. The flag symbol in the bottom right corner is for changing the language on the display. Selectable languages are English, Swedish, German, French and Italian. E-Mail: info@regincontrols.com 3

Symbols and icons on the Exigo Main page Settings: jumps to the setting page Hot water system Day mode District heating system Night mode Boiler control Increase / decrease setpoints in the heating system by 0.5 C Buffer tank Solar panel Settings page Example: 12 C 28 C 21 C 23 C 00.00 01.00 02.00 03.00 04.00 05.00 06.00 07.00 08.00 09.00 10.00 11.00 12.00 13.00 14.00 15.00 16.00 17.00 18.00 19.00 20.00 21.00 22.00 23.00 24.00 CT2 CT2 CT2 CT2 CT3 CT3 CT3 CT3 CT4 CT4 CT4 CT2 CT3 CT4 CT4 CT2 CT3 CT4 COMFORT TIME 1 COMFORT TIME 2 COMFORT TIME 3 COMFORT TIME 4 The text in the headline can be changed by pressing the pen. This will open a pop-up window where you can define a short-text (15 characters), used as name in the main-page, and a long-text, used as headline in the sub-page (40 characters). Shows the main temperatures of the system The setpoints of the 4 different comfort periods can be changed separately, the valid period will be highlighted The picture shows the start and stop of the timer, a press on the picture / diagram opens the page Timer settings E-Mail: info@regincontrols.com 4

Revision 2017-11-01 Timer settings COMFORT TIME 1 COMFORT TIME 2 COMFORT TIME 3 COMFORT TIME 4 The start and stop times can be changed for four periods in the selected day. Technical data Power supply Power consumption Dimensions, front (H x W x D) Touch panel Working temperature Ambient humidity Protection class, front Protection class, back 24 V DC, range 9 28 V DC < 6W 131.1 x 185,1x 7.3 mm Glass front panel with capacitive multi-touch interface -10 +60 C Max. 90% RH (non condensing) IP65 IP20 CE EMC emissions & immunity standards: This product conforms to the requirements of the EMC Directive 2014/30/EU through product standards EN 61000-6-2 and EN 61000-6-4 +A11. RoHS: This product conforms to the Directive 2011/65/EU of the European Parliament and of the Council through product standard EN 50581:2012. E-Mail: info@regincontrols.com 5

Dimensions 185.1 7.3 30.0 11 131.1 124.4 174.9 ( mm ) Accessories Article X1111 EDSP-K3 EDSP-K10 Description Power supply unit 3 m cable for connection to controller 10 m cable for connection to controller Wiring Wiring with EDSP-K3/K10 4 1 PIN OUT: 4P4C Black 1 White 2 Yellow 3 Brown 4 COM2 Not used (24 V) GND B- A+ PerProduct documentation Document Instruction Description Instruction for installation and connection of The product documentation can be downloaded from www.regincontrols.com E-Mail: info@regincontrols.com 6