RM4TA32 three-phase network control relay RM4-T - range V

RM4JA31M current measurement relay RM4-J - range ma V AC

RM4LA32M liquid level control relay RM4-L V AC

RM4JA01F current measurement relay RM4-J - range ma V AC

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

RM4JA32MW current measurement relay RM4-J - range A V AC DC

RM4UA33M voltage measurement relay RM4-U - range V V AC

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RE9RA21MW7 off-delay timing relay s V AC -

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RMCN22BD Analog Converter ma - for Zelio Analog

RSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RXM4AB1BD miniature plug-in relay - Zelio RXM - 4 C/O - 24 V DC - 6 A

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RM35TF V AC

RM35LM33MW liquid level control relay RM35-L V AC/DC

RM35LM33MW liquid level control relay RM35-L V AC/DC

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RPM13F7 power plug-in relay - Zelio RPM - 1 C/O V AC - 15 A - with LED

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

ABR1S102B. Main. Contacts type and composition [Uc] control circuit voltage Control circuit type

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

TM3DI16G module TM3-16 inputs spring

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR2B121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - display

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

RM17UB3. Price* : USD

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

TM3TI4 module TM3-4 inputs temperature

XCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

K1F006ALH cam switch - 6-pole A - screw mounting

ABS2EC01EB input interface module mm - solid state - 24 V DC

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

XPSMC32Z safety controller XPS-MC - 24 V DC - 32 input - 46 LEDs signalling

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

SR2B202BD compact smart relay Zelio Logic - 20 I O - 24 V DC - clock - display

SR2D101BD compact smart relay Zelio Logic - 10 I O - 24 V DC - no clock - no display

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

XCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

XB7EV07BP round pilot light Ø 22 - clear - integral LED - 24 V - screw clamp terminals

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

SR3B261BD modular smart relay Zelio Logic - 26 I O - 24 V DC - clock - display

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

XUX9ARCNT16 photo-electric sensor - XUX - polarised - Sn 11m VAC/DC - terminals

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

SR2A201BD. Main. <= 0.5 ma for IB...IG used as discrete input circuit. <= 5 Vfor IB...IG used as discrete input circuit V

RE Product data sheet Characteristics. time delay relay for star-delta starter ms - 230/380 V AC - 1 contact. Main.

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

XCMN2102L2 limit switch XCMN - steel roller plunger - 1NC +1NO - snap - 2 m

ABL8MEM24006 regulated SMPS - 1 or 2-phase V AC - 24 V A

TM3SAF. Main. Device short name

SR3XT43BD analogue I/O extension module - 4 I O - 24 V DC - for Zelio Logic

SR3XT101BD discrete I/O extension module - 10 I O - 24 V DC - for Zelio Logic

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

XACA2074 pendant station XAC-A pistol grip - 2 push buttons 1 Emergency stop

SR2E121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - no display

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

XB4BW73731B5 green flush/red projecting illuminated double-headed pushbutton Ø22 1NO+1NC 24V

Transcription:

Characteristics three-phase network control relay RM4-T - range 160..220 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Output contacts Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay Measurement range Contacts type and composition Poles description 220...240 V 50/60 Hz 160...220 V 220...300 V 2 C/O Setting accuracy of the switching threshold +/-3 % Switching threshold drift Setting accuracy of time delay Time delay drift Hysteresis Delay at power up Measuring cycle Marking Zelio Control Industrial measurement and control relays Control relay For 3-phase supply RM4-T Overvoltage and undervoltage detection Phase failure detection Phase sequence Adjustable 0.1...10 s 160...300 V 2 C/O 3P <= 0.5 % within the measuring range <= 0.06 % per degree centigrade depending permissible ambient air temperature 10 P <= 0.5 % within the measuring range <= 0.07 % per degree centigrade depending on the rated operational temperature 5 % fixed of de-energisation threshold < 650 ms <= 80 ms CE : EMC 89/336/EEC CE : LVD 73/23/EEC Overvoltage category III conforming to IEC 60664-1 [Ui] rated insulation voltage 500 V conforming to IEC Supply frequency 50/60 Hz +/- 5 % Operating position Any position without Electrical connection 2 conductors cable 2.5 mm² flexible without cable end conforming to IEC 60947-1 2 conductors cable 1.5 mm² flexible with cable end conforming to IEC 60947-1 Tightening torque Mechanical durability [Ith] conventional free air thermal current 0.6...1.1 N.m <= 30000000 cycles 8 A [Ie] rated operational current 0.3 A at 70 C 115 V DC-13 conforming to VDE 0660 0.3 A at 70 C 115 V DC-13 conforming to IEC 60947-5-1/1991 0.1 A at 70 C 250 V DC-13 conforming to VDE 0660 0.1 A at 70 C 250 V DC-13 conforming to IEC 60947-5-1/1991 3 A at 70 C 250 V AC-15 conforming to VDE 0660 3 A at 70 C 250 V AC-15 conforming to IEC 60947-5-1/1991 3 A at 70 C 24 V AC-15 conforming to VDE 0660 3 A at 70 C 24 V AC-15 conforming to IEC 60947-5-1/1991 3 A at 70 C 115 V AC-15 conforming to VDE 0660 3 A at 70 C 115 V AC-15 conforming to IEC 60947-5-1/1991 2 A at 70 C 24 V DC-13 conforming to VDE 0660 2 A at 70 C 24 V DC-13 conforming to IEC 60947-5-1/1991 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Mar 9, 2013 1

Switching capacity in ma Switching voltage Contacts material Number of cables 2 Height Width Depth Terminals description ISO n 1 Output relay state 9 mm pitches 2.5 Product weight 10 ma at 12 V 250 V AC <= 440 V AC 90/10 silver nickel contacts 78 mm 22.5 mm 80 mm (15-16-18)OC (25-26-28)OC (L1-L2-L3)CO Tripped, fault present 0.11 kg Environment Standards EN/IEC 60255-6 Product certifications CSA GL UL Ambient air temperature for storage -40...85 C Ambient air temperature for operation -20...65 C Relative humidity 15...85 % 3K3 conforming to IEC 60721-3-3 Vibration resistance 0.35 ms (f = 10...55 Hz) conforming to IEC 60068-2-6 Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27 IP degree of protection IP50 (casing) conforming to IEC 60529 IP20 (terminals) conforming to IEC 60529 Pollution degree 3 conforming to IEC 60664-1 Dielectric test voltage Non-dissipating shock wave 2.5 kv 4.8 kv Resistance to electrostatic discharge 8 kv air conforming to IEC 61000-4-2 level 3 6 kv contact conforming to IEC 61000-4-2 level 3 Resistance to electromagnetic fields 10 V/m conforming to IEC 61000-4-3 level 3 Resistance to fast transients 2 kv conforming to IEC 61000-4-4 level 3 Protection against electric shocks 2 kv conforming to IEC 61000-4-5 level 3 Disturbance radiated/conducted CISPR 11 group 1 - class A CISPR 22 - class A Contractual warranty Period 18 months 2

Dimensions Drawings 3-phase Supply Control Relays Dimensions 3

Mounting and Clearance 3-phase Supply Control Relays Rail mounting Screw fixing 4

Connections and Schema 3-Phase Supply Control Relays Wiring Diagram L1, Supply to be monitored L2, L3 15-18, 1st C/O contact of the output relay 15-16 25-28, 2nd C/O contact of the output relay 25-26 Application Scheme Example (1) Fault 5

Performance Curves Electrical Durability and Load Limit Curves AC Load Curve 1: Electrical durability of contacts on resistive load in millions of operating cycles X Current broken in A Y Millions of operating cycles Curve 2: Reduction factor k for inductive loads (applies to values taken from durability Curve 1) X Power factor on breaking (cos φ) Y Reduction factor K Example: An LC1-F185 contactor supplied with 115 V/50 Hz for a consumption of 55 VA or a current consumption equal to 0.5 A and cos φ = 0.3. For 0.5 A, curve 1 indicates a durability of approximately 1.5 million operating cycles. As the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles as indicated by curve 2. For cos φ = 0.3: k = 0.6 The electrical durability therefore becomes: 1.5 x 10 6 operating cycles x 0.6 = 900 000 operating cycles DC Load Load limit curve X Current in A Y Voltage in V 1 L/R = 20 ms 2 L/R with load protection diode 3 Resistive load 6

Technical Description Function Diagram Overvoltage and Undervoltage Detection Functions "Fault detection delayed" or "Fault detection extended (by switch selector) t Time delay (adjustable from 0.1 s to 10 s with a selector switch) U 3-phase supply voltage monitored (between terminals L1, L2 and L3) S Overvoltage or undervoltage setting 15/18, Output relays connections (refer to Connections and Schema) 15/16; 25/28, 25/26 Relay status: black color = energized. NOTE: In order to be detected, the duration of the overvoltage or undervoltage must be greater than the measuring cycle time (80 ms). 7