Residential air leakage measurement system comparison: Retrotec Blower Door & Minneapolis Blower Door

Similar documents
Comparison between Retrotec and Minneapolis Gauges

Speed Control Adapter

Minneapolis Blower Door Building Air tightness Testing Systems

Price List. System Description List Price Image DE V/50Hz DucTester 2, case, 20 ft (6m) umbilical and hard panel

Retrotec Model DM-2A mark II Dual Channel Pressure Gauge. User Guide

Field Calibration Check Procedure Minneapolis Duct Blaster System (with DG-700)

Please send completed forms by to: Shipping Address (if different than Billing Address): Contact Name: Company Name: Street Address:

rev Operation Manual Software FanTestic (Duct Testing)

Heavy Duty Pitot Tube Anemometer and Differential Pressure Manometer

FlowBlaster. Operation Manual. Attachment for the Minneapolis Duct Blaster Fan and DG-700 Pressure and Flow Gauge

itec-700 for PC (The itec-700 App is also available for both ios and Android devices.)

Model R3001. Instruction Manual. Anemometer/Manometer. reedinstruments. www. com

H Manual Stretch Wrap Machine uline.com FILM ROLL CAPACITY TECHNICAL DATA ELECTRICAL SPECIFICATIONS TURNTABLE SPECIFICATIONS

vlocdm2 Rx & Loc-150Tx Data Sheet V1.6

BlowerDoor. Standard. Minneapolis BlowerDoor Modell 4.1 with DG-1000 TECTITE Express version 5.1

What is new at The Energy Conservatory?

RE 4 Fan Owner s Manual

CONSERVATORY. The ENERGY. TECTITE (Ver. 4.0) Software User s Guide. (Building Airtightness Test Analysis Program)

Manual Anemometer PCE-423

Thunderbolt Docking Station for Laptops - Includes TB Cable

Product End-of-Life Disassembly Instructions

Minneapolis BlowerDoor Measurement Systems

[ Air Velocity Measurement Techniques from Alnor

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

rev Operation Manual Software FanTestic (ASTM)

Operating Manual. for HXOC Page 1 of 5

Operation Manual. rev Software. FanTestic (ATTMA) Retrotec Inc.

Large Vane CFM/CMM Thermo-Anemometer

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

Manual. C500B LCD Instructions

TEC WiFi Link and Updated itec-700 ios App

Vacuum Tubes Power Supply Unit. for WA7 and WA7d Fireflies. Owner s Manual. Please review this manual before operating your WOO AUDIO product.

User's Manual. VA893 Thermo Anemometer

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

ANEMOMETER OPERATION MANUAL. metal vane + air flow. Model : AM-4206M

ST1016 INSTRUMENTATION FOR RENEWABLE ENERGIES

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

Large Vane CFM/CMM Anemometer / Psychrometer

SCOREBOARD SPECIFICATIONS FOR

HELSINKI, FINLAND, 2018 STARDEX 0304 COMMON RAIL PUMP AND INJECTORS TESTER

[ Capture Hoods. What is a capture hood?

vlocml2 Rx Data Sheet V1.6

1450 First Ave. Page 1 of 7 Chippewa Falls, WI (800) or (715) Fax: (715)

Product End-of-Life Disassembly Instructions

C500B-LCD Instructions

Dual Monitor USB-C Dock - 60W Power Delivery - 4K

Heavy Duty CFM Thermo-Anemometer Model

Product End-of-Life Disassembly Instructions Product Category: Desktops

IL-885 Inline Cabinets

DVI Dual-Monitor Docking Station for USB-C Laptops - Includes USB-C to A Adapter, HDMI, and VGA Adapters

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS. Wall or window extract fans HV-STYLVENT. Elegant design harmonising with any environment

Model 6812 VOLUME FLOW ANEMOMETER. User Manual. Kanomax USA, Inc. 219 Route 206 PO Box 372. Andover, NJ USA. (800) Fax: (973)

Model 6812 VOLUME FLOW ANEMOMETER. User Manual. 219 Route 206 Phone: PO Box 372 Fax: (973)

Operation Manual. FreeStyle 31/21 LED LED-151X

HELSINKI, FINLAND, 2018 STARDEX 0306 COMMON RAIL PUMP AND INJECTOR TESTER WITH EMBEDDED FLOWMETER

Docking through USB-C is simple

HDAF800 HD 1080p Digital Microscope USB drive for Image Capture

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

Product End-of-Life Disassembly Instructions

NETRONICS HS3500 CONTROLLER

Heavy Duty Mini Vane CFM Thermo Anemometer

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

GA-12. madur Polska sp. z o.o.

SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

DC-AC Inverter Pure Sine Wave 120 Watt. Please read this manual before installing your Inverter. Manual PST

Vaisala HUMICAP Structural Humidity Measurement Kit SHM40. Full SHM40 product presentation and introduction to the borehole method

Product End-of-Life Disassembly Instructions Product Category: Personal Computers

User's Manual. CFM/CMM Thermo Anemometer + InfraRed Thermometer. Model : BST-AFM05

Anemometer SD Card Datalogger. Instruction Manual

Product End-of-Life Disassembly Instructions

Host Controller: HST-4002

Multi-Range Programmable DC Power Supplies 9115 Series

CLEVELAND CONTROLS MODEL 6650 DIGITAL MANOMETER INSTRUCTION MANUAL DM

Heavy Duty Hot Wire CFM Thermo-Anemometer

Omni LCD 650VA Tower Line-Interactive 120V UPS with LCD display and USB port

Dual-Monitor USB-C Dock for Windows - 4x USB 3.0 Ports

Model 6813 THERMO-ANEMOMETER. User Manual. Kanomax USA, Inc. 219 Route 206 PO Box 372. Andover, NJ USA. (800) Fax: (973)

Wireless (WiGig) or USB-C Dual-Monitor Docking Station for Laptops - Power Delivery

USB-C Docking Station for Laptops - 4K HDMI - 85W Power Delivery - USB 3.0

SigmaCheck. Fully Featured Eddy Current Conductivity Meter ET NDE

HELSINKI, FINLAND, 2018 STARDEX MASTER ULTIMA COMMON RAIL, UIS/UPS, HEUI PUMP AND INJECTOR TESTER WITH EMBEDDED FLOWMETER

SmartPro 230V 1.5kVA 900W Line-Interactive UPS, 2U Rack/Tower, LCD, USB, DB9, 8 Outlets

1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

EMPowered Motorized Touchscreen Smart Keypad Lock

Product End-of-Life Disassembly Instructions Product Category: Personal Computers

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS HV-STYLVENT. Wall or window extract fans. Elegant design harmonising with any environment

Description Front View of SSC-0025 Rear View of SSC-0025

USER GUIDE. For more information visit

VRX & VR12. GrainVac

FG-7000L Digital Force Gauge Operation Manual

kena Instruction Manual T-1050

Accutrol, LLC Product Sheet AVC5000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

HDMI to CAT5 Extender W/ Optional Repeater Functionality and Audio 1080p / 1920x1080

GROMMETS. Kitchens. Doors. Kitchen Accessories. Hinges. Drawer Slides. Plywood Melamine. Veneer Edgebanding. Laminate. Solid Surface.

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT

Display Flexibility. DVI Dual-Monitor Docking Station for Laptops - HDMI and VGA Adapters - USB 3.0. StarTech ID: USB3SDOCKDD

Product End-of-Life Disassembly Instructions

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired

Transcription:

Residential air leakage measurement system comparison: Retrotec Blower Door & Minneapolis Blower Door Use this guide to compare features of the two top US manufacturers. Retrotec Model 1000 Blower Door Minneapolis Model 3 Blower Door Page 1 of 8

Retrotec The Companies Company founded: 1980 1981 CEO: Colin Genge Gary Nelson The Energy Conservatory Manufactured in: Everson, WA, USA Minneapolis, MN, USA US employees About 60 About 30 Primary applications: Large notable customers: Residential audits and inspections Residential marketing Commercial Industrial Fire-suppressant containment Smoke containment Industrial such as Siemens & Tyco Community Action Programs Warranty Two years on system 10 years on shell Residential audits and inspections Community Action Programs Low Income weatherization agencies in most States. Two years on system 5 years on shell Retrotec Everson, WA, USA The Energy Conservatory Minneapolis, MN, USA Page 2 of 8

Both have: * extruded aluminum frame * nylon cloth * Velcro tabs * rubber gaskets The Door Panels Doorway Widths: Large frame: Doorway Heights: Large frame: Cam lever and knobs: Numbered frame pieces Red anodized 29.5 43 in (75 109 cm) 32 50 in (81 127 cm) 53 97 in (135 246 cm) 60 109 in (152 278 cm) Black anodized 28 in. to 40 in. (61 cm to 101 cm) 52 96 in (131 242 cm) Molded plastic cam lever and rubber covered knob Molded plastic cam lever and knob Page 3 of 8

The Retrotec DM- 2A design has been around since 2006 with a built in automatic controller. Its firmware can be easily updated over the Internet to take on new improvements like the larger display shown. Retrotec DM-2 digital gauge The Digital Gauges Minneapolis DG-700 digital gauge The Minneapolis DG-700 gauge has been around since 2000 and is widely used. Its display size and content is fixed. A built in automatic controller was added in 2010. Gauge to fan distance: Accuracy: Speed control built into fan top. TV clicker style control in gauge will adjust fan speed by Jogging up or down, setting speed or setting pressure. Courtesy of the Retrotec Everson, WA, USA 6 feet standard. Unlimited using Ethernet cable or optional umbilical extensions. 1% of pressure reading or 0.15 Pa, whichever is greater. Result Modes: Speed control knob in separate box. Gauge will adjust fan speed by setting pressure. Courtesy of the Energy Conservatory, Minneapolis, MN, USA 1 foot from gauge to control. Control to fan limited by (120 or 240V) power cord. 1% of pressure reading or 0.15 Pa, whichever is greater. Channel A: Pressure in: Pa, in.wc., PSF Pressure in: Pa, in.wc. Channel B: Flow in: Pressure in: Pa, in.wc., PSF Flow in: cfm, l/s, m 3 /s, m 3 /h Flow @ (any pressure) Calculates flow at ANY desired pressure configured in Setup menu or from the Set Pressure Pressure in: Pa, in.wc. Flow in: cfm, l/s, m 3 /h Flow at 25 and 50 Pa Calculates flow at two pressures. Channel B: EqLA (Canadian), EfLA (US) in: cm 2, in 2, ft 2 Leakage Area EqLA (Canadian) in cm 2, in 2 Leakage Area: Leakage Area @ (any pressure) calculates EqLA at ANY desired pressure configured in Setup Menu Leakage Area @ (25 and 50 Pa) calculates EqLA at two pressures. Page 4 of 8

Channel B: Air-changes per hour Calculated according to volume entered on keypad Permeability, normalized flow. Flow per unit area in CFM/ft 2, liters/s/m 2, CFM/100 ft 2, m 3 /h/m 2 according to area entered on keypad Normalized Leakage Area Velocity EqLA and EfLA per unit area in, in 2 /100ft 2, cm 2 /m 2 according to area entered on keypad m/s, km/h, ft/s, ft/min, mph Velocity-Flow in cfm, l/s, m 3 /s, m 3 /h according to cross-sectional area entered on keypad. m/s, ft/s Flow Devices that can also be calculated by the gauge: Remembers settings?: Display: Retrotec: DU-100 & DU-200 Duc-Tester fans Retrotec: 600, 700, 800, 900, 2000, 3000 & 3000 SR fans Minneapolis: Duct-Blaster, Model 3(120V), Model 3(240V) and Model 4(240V) fans, Tru-Flow Grid, Fan Flow Meter Infiltec: Model E3 Pitot tube Yes, goes back to last settings. Minneapolis: Duct-Blaster, Model 3(120V), Model 3(240V) and Model 4(240V) fans, Tru-Flow Grid, Fan Flow Meter Pitot tube No, goes to default settings Batteries: 4-NiMH AA rechargeable batteries, supplied Time averaging: AC power adapter included Batteries rated for two years and can be recharged weekly or from the fan top. Off, 1, 2, 4, 8, 10, 20, 60, 120 seconds, rolling average Auto zero: Every 8 seconds Every 10 seconds Backlight: yes yes Auto shut down: Adjustable from Menu Two hours 6 - AA alkaline batteries, supplied AC power adapter optional Batteries rates for over 100 hours continuous use 1, 5, 10 seconds, and Long-Term, block average Page 5 of 8

Connections: Color coded tapered connections Mini USB to computer Fan control by Ethernet style cable. Reset switch AC Power Brass connections Serial and mini USB port to computer Fan Control port Speed control from gauge: Set to any pressure from -1200 to 0 to +1200 Pa Set to a pressure of 0, 25, 50 or 75 Pa Set to % TV remote style jog keys Cruise control: Set to 0 or any pressure Extrapolation pressure: Laptop stand: Set to zero control, automatic Adjustable to any pressure for any result in set up menu To any Set Pressure Adjustable slope, n =0.5 to 1 Set to 0, 25, 50 or 75 set to zero control, one direction To 25 and 50 Pa Fixed Slope, n =0.65 Optional case can be used as laptop table. Optional laptop stand Page 6 of 8

Fan shell: The Fans Model 1000 Model 3 Flow at 50Hz: 5600 CFM in free air Flow at 60Hz, USA Actual flows may vary 5100 CFM at 50Pa 4800 CFM at 75Pa 6700 CFM in free air 6100 CFM at 50Pa 5800 CFM at 75 Pa Weight: 34 lb with Ring A&B 35 lb with 7 flow ranges Dimensions: Fan Height: 25 in (66 cm) Fan Inlet Diameter: 22 in (56 cm) Fan Depth: 10 in (24 cm) Fan blades: 8 6 5300 CFM in free air 4350 CFM at 50Pa 4000 CFM at 75Pa 6300 CFM in free air 5350 CFM at 50Pa 5000 CFM at 75 Pa 33 lb with Ring A&B Fan Height: 24 in (61 cm) Fan Inlet Diameter: 20 in (50 cm) Fan Depth: 10.25 in (26 cm) GE Motor: 3/4hp, 1625 RPM @60Hz 3/4hp, 1625 RPM @60Hz Input power: 110 V 50Hz, 120V 60 Hz, 240 V 50 Hz Maximum current: 110 V 50Hz, 120V 60 Hz, 240 V 50 Hz 9.4 amps at 120 V 60Hz 10.5 amps at 120 V 60Hz Page 7 of 8

Flow ranges: 7 flow ranges, included 3 flow ranges included 3 additional ranges optional Fan cross-section: Fan top: Flexible homogenous 2 piece injection molding held together with 7 rivets on flange. Fiber reinforced 2 piece injection molding held together with 4 rivets on flange. Flow connections: Fan control: On board speed control allows speed to be controlled using a knob on the fan top or use the 6 ft umbilical to connect to the digital gauge. An optional remote will control the fan up to 100 ft away. Gauge connection status light. Power connection status light. Run up to 24 fans together with daisy chain Ethernet connectors. Tapered fan pressure fitting, color coded to match tubes. Power (120 or 240V) using computer style power plug. Ethernet cable supplies speed signal to on-board speed controller. External speed control allows speed to be controlled using a knob on the control box up to 6 ft away or a computer. Reversing switch. Barbed fan pressure fitting, brass. Variable power (120 or 240V) using computer style power plug from remote speed controller attached to gauge. Page 8 of 8

Speed control design: Triac circuit for speed control on power cord. Manual speed control attached to power cord. Regulated Triac circuit for steady speed control in fan top. Remote optional will connect to any length of Ethernet cable to control fan from a distance. Computer control: Automatic, semi-automatic or manual control using a computer and Retrotec FanTestic software. Automatic control using a computer and EC Tectite software. Page 9 of 8