CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

FTK5 PROXIMITY KEYPAD

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

W3-H Waterproof Keypad/Reader/Controller

VIS-3200 / VIS-3201 User Manual

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

Single Door Standalone Access Control User Manual

-DTZ001- Stand-Alone Proximity Access Control. User Manual

Stand-alone Proximity Access Control

EL-ST100 KEYPAD CONTROLLER

User Manual. PCKeypad Wireless Keypad

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

RFID/Digital Access Control Keypad

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

Metal Standalone Keypad Access Control S100

VIDI-AC-2CS Access Controller/ Reader

RBR-SB-KTZ001 LAR 2. User Manual

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

W3-M. Metal waterproof standalone access control/reader. User Manual

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

BC Digital Keypad. User Manual

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

CM-500 SK 500 USER CODES KEYPAD

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

Digital Keypad Introduction

2000 Series e/em Style Keypad Installation and Programming Manual

User Manual. Split access control with intelligent secured power supply.

Waterproof Exit Button x40x30/44mm - IP68, 304 Stainless Steel - Voltage: DC12V, DC9-24V (-W402N)

Two Door Controller GEN-045

KP2000E/EM Series Style Keypad

Outdoor Stand-Alone Weatherproof Keypads

Fingerprint Access Control F1. User Manual

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

7612 Programming Instructions

IBA-7612 Programming Instructions

1. Product Specification

INSTALLATION INSTRUCTIONS 923P EntryCheck TM

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions

AK-21. Digital Keyless Entry System. Installation and Programming Instructions

REX F-0-9 Standalone or Access Controller

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

Proximity Card and Pin Reader Installation Manual

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

180 Series Keypad. Handbook. Revision 2.1

FEATURES AND PROGRAMMING GUIDE SELF-CONTAINED ACCESS CONTROL SYSTEMS:

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

Enter a new user. code. Enter. Enter a 2-digit user ID. Enter a user code. (from 00~09) (from 00~09) Enter

Specifications: Features:

ACTsmart2 Product Range Operating and Installation Instructions

Fingerprint Door Lock OPERATOR S MANUAL

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

PAC2 Dual Door Access Controller

SK-1011-SQ Digital Access Keypad with 5A Relay Output

Fingerprint Door Lock User MANUAL

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

BACK-LIT KEYS KEYPAD 100 USER CODES FLUSH MOUNT

ACCESS CONTROL SYSTEM

HSY-S209 EM Metal waterproof access control system User Manual

RFID PRODUCT AND SYSTEM

AC-Q4x Family Anti-Vandal Standalone Controllers Installation and Programming Manual

PAC1 Door Access Controller

PAC1 Door Access Controller

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

TOUCHLOCK compact. Ins-182 Date code:

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD

CP150B Vandal & Weather Resistant Keypad Security Systems

212iL Rev. 1.1

ACTentry A5 Kit. ACTentry A5 Entry Panel. Audio Door Entry with Access Control. Audio Door Entry & Access Control Kit Features

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

MANUAL PIN CODE KEYPAD February 2013

EX8. User Manual. Ver 1.0

GV-AS Controller. Installation Guide

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

ENFORCER SK-1131-SQ. Digital Access Keypad with 5A Relay Output MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

232iLM Keypad Installation and Programming Instructions

Installing Keypad and Backplate

Access control panel U-Prox IC E (Elevator control)

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

Transcription:

DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity Card (default setting) b. PIN or Proximity Card c. PIN + Proximity Card 3. Logical memory prevents duplicated card setting. 4. Lockout Function: The controller will lockout for 60 seconds after entering 5 times invalid codes or cards. (The keypad doesn t beep during the period of time). 5. Controller with keypad sound avoids incorrect key-in. 6. Additional input for anti-tailgating function ensures high security access control. 7. Built-in tamper switch. 8. Non-volatile memory stores all code settings for a long time, even in the event of total power failure. 9. Dual relays to control door lock and other security devices. 10. Aluminum alloy case designed with vandal resistant screws for enhanced safety and durability. 11. Epoxy sealed for waterproof grade IP65. Page: - 1 -/ 8

II. Specification Operating Voltage 12 VDC Current Draw Pull-In: 60mA/12 VDC, Holding: 30mA/12 VDC RF Frequency EM 125kHz Read Range 5 cm (In noise-free environment) Keypad Backlight 12 digits (0~9, *, #) 2 contacts for Request-To-Exit button Input 1 contact for door reed switch Output 2 relays (N.O./N.C./Com. Dry Contact) LED indicator 2 LED indicators display (Red/Green) Memory Volume 1000+10 proximity cards/tokens and PINs Relay Electric Current Max. 2A/30 VDC, 0.6A/120 VAC Relay Strike Time 01~99 seconds or Toggle Mode(00) Ambient Humidity 5%~95% (Non-condensing) Operating Temperature -20 C~70 C Page: - 2 -/ 8

III. Indicator Status & Default Setting Parameters Beep & LED Indication: Mode Signal Status Standby Right Green Stay On Green On Red On Power on, Standby First relay active Second relay active LED Yellow Stay On Green Stay On Programming Red Stay On Green Stay On Red Stay On Enter programming mode The slot position of first relay is available. The slot position of first relay is unavailable. The slot position of second relay is available. The slot position of second relay is unavailable. Beep 1 Beep Valid card, key press, enter programming mode Standby 3 Beeps Invalid card, incorrect PIN 1 Beep Correct input data, exit programming mode Programming Incorrect input data, other incorrect operation, 3 Beeps duplicated card setting Factory Default Setting: Access Mode Format Card Storage (MAX. 1000+10 pcs) Master Code Alarm Function (All) Relay Strike Time (Time Delay Setting) Pressed Key Time Delay PIN Code Input Waiting Time Programming Mode Time Delay Proximity Card Only All Bits None 12345 (5 digits) Function disabled 5 seconds 5 seconds (Fixed) 5 seconds 25 seconds (Fixed) Page: - 3 -/ 8

IV. Wiring Diagram Door Status For DC use only For AC/DC Note: 1. It is suggested to use a linear power supply unit to prevent reading range reduction at the card reader. 2. It is suggested to use #22~26 AWG insulation wire. 3. Exit button is at N.O. contact. 4. With CE qualification EMC specification. 5. The door strike or relay must have a varistor or a diode across the door strike terminals to suppress the back EMF of the strike failure to do so will damage the relay contacts and electronic components, or even burn the controller. Page: - 4 -/ 8

V. Operation Instruction 1. Master Code The master code comprises a five-digit number and is used to perform programming functions of the digital keypad and cannot be used for access i.e. it cannot be the same as other PINs. The default master code is set as 12345. Under normal operation the keypad is used for entering PIN to gain access. In the programming mode the keypad can be used to add/delete PINs, set relay strike time and other operation functions. 2. Entering Programming Mode Enter the master code twice (12345 12345) to enter programming mode (1 long beep, Right Yellow LED stay on). 3. Setting the Access Mode The dual authentication feature allows the keypad to be programmed to grant access with either Proximity Card only, PIN or Proximity Card, Proximity card and PIN. 2. Press*0 (Right Yellow LED rapid flash) 3. Press 00 (1 beep, Right Yellow LED stay on) for Proximity Card Only Press 01 (1 beep, Right Yellow LED stay on) for Proximity Card or PIN Press 02 (1 beep, Right Yellow LED stay on) for Proximity Card + PIN 4. Setting the Relay Strike Time The relay strike time determines the amount of time that the door remains unlocked after a valid proximity card or PIN is entered. *NOTE: For both Relay 1 & Relay 2, enter 00 will set the relay strike time to 0 second (relay set to toggle mode). 2. Press*1 for Relay 1 (Right Yellow LED rapid flash Press*5 for Relay 2 (Right Yellow LED rapid flash) 3. Press 00~99 (1 beep, Right Yellow LED stay on) 4. Press # (1 beep Right Green LED stay on) back to standby mode Page: - 5 -/ 8

5. Clearing Memory of All Proximity Cards and PINs 2. Press*8 (Right Yellow LED rapid flash) 3. Press 88 (Right Yellow LED stay on, 1 long beep) 6. Resetting Controller Parameter to Default Value 2. Enter*8 (Right Yellow LED rapid flash) 3. Enter 99 (Both left & right Yellow LED stay on, 1 beep) 7. Adding a Proximity Card and PIN to Relay 1 a. to select slot position 000~999 (Left Green LED stay on, Right Yellow LED rapid flash to indicate the slot position is available) 2. Read new card (1 beep), then press 5-digit PIN 99999(1 beep, Right Yellow LED stay on). 3. Press # (1 beep Right Green LED stay on) back to standby mode NOTE: Master codes must NOT be the same as PIN codes. b. to select slot position 000~999 (Left Red LED stay on, Right Yellow LED rapid flash to indicate the slot position is unavailable) 2. Press**(1 beep), delete the data from the slot position (Left Green LED stay on, Right Yellow LED rapid flash) 3. Repeat the steps of 7-a to add new card. 8. Adding a Proximity Card and PIN to Relay 2 Page: - 6 -/ 8

a. b. 2. Press *4 to select slot position 00~09 (Left Green LED stay on, Right Yellow LED rapid flash to indicate the slot position is available) 3. Read new card (1 beep, Right Yellow LED stay on) 2. Press*4 to select slot position 00~09 (Left Red LED stay on, Right Yellow LED rapid flash to indicate the slot position is unavailable) 3. Press**(1 beep, Left Green LED stay on, Right Yellow LED rapid flash) 4. Repeat the steps of 8-a to add new card. 9. Changing Master Code 2. Press*3 (Right Yellow LED rapid flash) 3. Enter 5-digit master code twice e.g. 45678 45678 (1 beep, Right Yellow LED stay on) 10. Adding a New Master Card to Relay 1 a. 2. Press*7 (Left Green LED rapid flash, Right Yellow LED rapid flash to indicate the slot position is available) 3. Read new card to set as Master Card (1 beep, Right Yellow LED stay on) b. 2. Press*7 (Left Green LED stay on, Right Yellow LED rapid flash to indicate the Master Card had been stored) 3. Press**(1 beep, Left Green LED rapid flash, Right Yellow LED rapid flash) 4. Repeat the steps of 10-a to add new master card. Page: - 7 -/ 8

11. Adding New Cards by Master Card a. 1. Read master card once (1 beep, Right Yellow LED stay on) 2. Enter slot position 001~999 (Left Green LED stay on, Right Yellow LED rapid flash to indicate the slot position is available 3. Read new card (1 beep), then enter 5-digit PIN 99999 (1 beep, Right Yellow LED stay on) b. 1. Read master card once (1 beep, Right Yellow LED stay on) 2. Enter slot position 001~999 (Left Red LED stay on, Right Yellow LED rapid flash to indicate the slot position is unavailable) 3. Press**(1 beep, Left Green LED stay on, Right Yellow LED rapid flash) 4. Repeat the steps of 11-a to add new card. 12. Turning Anti-Tamper Alarm Function ON/OFF 2. Press*6 (Right Yellow LED rapid flash) 3. Press 01 (1 beep, Right Yellow LED stay on) function OFF Press 02 (1 beep, Right Yellow LED stay on) function ON 13. Turning Doorbell Alarm Function ON/OFF 2. Press*2 (Right Yellow LED rapid flash) 3. Press 01 (1 beep, Right Yellow LED stay on) function OFF Press 02 (1 beep, Right Yellow LED stay on) function ON 14. Reseting the Master Code to Default Value Turn off the power Press # continuously, and energized (1 beep) the master code is reset to default value. Page: - 8 -/ 8