USER MANUAL. WBI414F21 AC current transducer

Similar documents
USER MANUAL. WBI412F41 AC current transducer

USER MANUAL. WBV412U01 AC voltage transducer

Operating Instructions Differential Pressure Transducer PS27

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

TM3TM3 module TM3-2 temperature inputs and 1 analog output

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

TM3AI4 module TM3-4 analog inputs

VM-11 SERIES MODEL VM-11B ACCELERATION INPUT VIBRATION SIGNAL CONDITIONER INSTRUCTION MANUAL. MANUAL No E1.8. Revised in Mar.

OPERATOR S MANUAL 9000U ISOLATOR

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

TM3TI4 module TM3-4 inputs temperature

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 42000

TM3TI4 module TM3-4 inputs temperature

PHOENIX CONTACT - 07/2006

CUS150M1 Instruction Manual

I/O SIGNAL CONDITIONER

Operating instructions. Switching amplifier DN0210 DN / / 2015

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Electronic Temperature Controller. Instruction Manual Version

ELV12 Series. Instruction Manual

AC/DC Current Probe Model SL206 USER MANUAL

Installation Instructions for the ISSUE 3 RDS-DIN1 Series Single Channel Interface Module PK 80103

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

AS-i Safety Relay Output Module with Diagnostic Slave

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

7032 Digital-Analog Multimeter

TM3TI8T module TM3-8 inputs temperature

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

LCI User Manual mantracourt.com

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

LCI Load Cell Junction Box with Fault Monitor

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

MINI MCR-SL-PT100-UI(-SP)(-NC)

Operating instructions. Standstill monitor A / / 2011

Ultra Slim Relays 24

Instruction Manual. T3110 T3110L T3110Ex

PRODUCT SPECIFICATION. PC Board Relays. Series.

Standard-Signal Isolation Amplifiers. VariTrans A 21000

Setpoint Isolators. Technical Manual. HA Issue Parker SSD Drives, a division of Parker Hannifin Ltd. WARRANTY

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

Transducers for Pt-100/1000, Resistors

VariTrans P Standard-Signal Isolators

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

EX-RC1 Remote I/O Adapter

MINI MCR-SL-PT100-UI-200

Zener Barriers Bulletin 937Z

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

MDM 011-Z1 Regen Resistor

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

User's Guide. Phase Sequence and Motor Rotation Tester Model

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

DINALOG A 144 x 36 A1400 Light-Strip Indicator

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

AC/DC Current Probe Model SL201

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

IELR Rail-Mount Series Magnetic Circuit Protectors

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

INSTALLATION, OPERATION, CONFIGURATION AND MAINTENANCE MANUAL September/2016 VTT10-PH. HART TEMPERATURE TRANSMITTER panel model

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

UTAH-100/XHDA SERIES

I/O Expansion Box Installation & Operator s Instruction Manual

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

User's Guide. Extech AM A AC Analog Clamp Meter

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing.

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Model 7705 Control Module

Tempco Instruction Manual

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

CSMIO-MPG. 6-axis Manual Pulse Generator (MPG) Module. Rev copyright 2014 CS-Lab s.c.

HI ma Simulator

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

MT8050iE series. Installation Instruction (1) (2)

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

Product and functional description

Transcription:

1 Designing, Manufacturing and Supplying WB Series Electric Isolated Sensor and Digital Electrical Transducer since 1989 USER MANUAL WBI1F21 AC current transducer www.wb-my.com wblch@wbdz.cn Technical Service: 86 816 2778271 Quality Complain: 86 816 227827 Fax Line: 86 816 22819 ISO9001 ISO1000 ISO18000 Certified Quality Warranty Any quality problem found in WB series products, we offer Three years free charge of repair the products, and six months guaranteed free charge of change and return the products. 1

2 WBI1F21 AC Current Transducer Safety claim The information in the safety claim of the equipment documentation is intended to ensure that equipment is properly installed in order to maintain it in a condition. It is assumed that everyone who would be associated with the equipment should be familiar with the contents of that safety section, or this safety guide. When electrical equipment is in operation, dangerous voltages will be present in certain parts of the equipment (e.g. the input terminal). Failure to obverse warning notices, incorrect use, or improper use may endanger personnel and equipment and course personal injury or physical damage. Before working in the terminal strip area, the equipment must be isolated. Proper and safe operation of the equipment depends on appropriate shipping and handling, proper storage, installation and commissioning, and on careful operation, maintenance and servicing. The operating manual for the equipment gives instructions for its installation, commissioning, and operation. However, the manual cannot cover all conceivable circumstances or include detailed information on all topics. In the event of questions or specific problem, do not take any action without proper authorization. Contact the appropriate WB technical sales office and request the necessary information. Standard application 1. Accuracy Accurate degree is conformed to IEC688:1992 2. Safety 2.1 Overload capability Overload capability is conformed to IEC688:1992 2.2 Isolation voltage Can be endured testing voltage is conformed to Q/7208558-0.1-200 2. Insulation impedance The insulation impedance is no less than 20M Ohm, is conformed to Q/7208558-0.1-200. Electromagnetic Capability.1 Electromagnetic field immunity test according to IEC 61000--:1995.2 Power frequency magnetic field immunity test according to IEC 61000--8:199 Product Description and Application WBI1F21 converts AC input current into a load independent output signal DC -20mA.,It has adopted electromagnetic isolation principle for real time measurement of AC current (sine wave form) from electric net or electric circuit. 2

The product has certain advantages of total galvanic isolation between input/output and auxiliary power, high accuracy, low drifting by temperature, and wide temperature bearable range, etc. Function realization schematic drawing + In 1 +E G Out Product Dimensional Drawing (unit: mm) Input Current Direction Indicator light Output Terminal DIN Mounting Rail Spring Clasp Product Terminal Identification Drawing 1 2 Auxiliary Power(+E) Auxiliary Power and Ground(GND) Output(I Z ) Measuring current input (through window) Non-identified terminals cannot be used! Key Technical Data:

1. Input: 0A 00A; 2. Output: -20mA. Frequency range: 25Hz~5kHz. Accuracy : 0.5% 5. Input Impedance (R): approximate zero 6. Linear Range:0-120% of nominal input 7. Responding Time: 00ms 8. Over Load Capacity: 0 times of nominal input, for 5 seconds; 9. Maximum Load: 6V 10. Static current: 6.8mA(mA-20mA) 11. Auxiliary Power: +12V/+15V/+2V,dc 12. Current consumption for static status:17ma 1. Isolation Voltage: 2500Vdc, for 1 minute 1. Output Ripple: <6mV (root-mean-square value, output load is 250Ohm) 15. Drifting by Temperature:.5 10 - / Ambient Temperature: 0 ~+50 (Commercial Grade) 16. Mounting : DIN Rail 5mm Mounting Instruction of Installation and Use 1. The product has adopted structure compliance with EN50022; suitable for DIN rail mounting NS5/7.5, NS5/15. Installation steps are as following (please reference to dimensional drawing): Step 1: Immobilize one side of product s mounting trough to the DIN mounting rail; Step 2: Pull out the spring clasp; Step : Place whole mounting trough to the DIN mounting rail properly; Step : Release spring clasp to make sure the installation. 2. The product has calibrated before out of factory. After correctly wiring, it can be powered and used immediately. But for further precise signal sampling, user needs to warm-up the product for minutes before use. a) The auxiliary power requires isolation voltage 2000V AC, DC current output ripple <10mV, and multiple converters can share with one set auxiliary power together. b) Output signal (Iz) is designed to follow the impedance load value of 250Ω; When Resistance (R1 ) is less than 100Ω, the user must add output current circuit a power reduced resistance load R0 to keep the summation of total impedance value is between 100Ω~250Ω

5 Transducer R0 IZ RL User system. The Maximum volume of line for the transducer terminal is 2.5mm 2 ; the insulation layer of the line should be peeled off about 8mm~10mm and tightly twisted to connect with the transducer terminals.. For the less than 10A AC current measurement, it may adopt ampere-turn method for input and for this time, the resolution of the transducer increases and measuring range narrows, but other technical index may not be affected. 5. Basic testing method for accuracy (1) According to the terminal definition table to connect the testing circuit; (2) The testing must to be done by under the following conditions; Auxiliary power: 2V±0.5%,ripple 5mV Ambient temperature: 25 ±5 Relative humidity: RH(5~75)% Accuracy for Signal Power Source instrument: 0.05 Auxiliary Power + V1-1 + Power Source R R V2 Transducer - () Warming up the transducer for minutes () Using output monitoring meter V1 to measuring the output of signal power source instrument, set any input value which is within the measuring range of the transducer Ir. (e.g. if input value is 50A, the output is -20Ma, the expected output value Iz should be calculated as: Iz = (20mA-mA) Ir/50A+mA ) 5

6 (5) Using output monitoring meter V2 to measuring the output voltage V0 of the transducer, the basic introduced errorγof the transducer should be calculated as: γ= (Vo-Iz 250Ω)/[(20mA-mA) 250Ω] 100 (6) Repeating step () (5), if calculated absolute value is less than the given accuracy value of the transducer, it shows the transducer s accurate grade is qualified. Caution: 1. Pay attention to the auxiliary power information, especially the auxiliary power grade, and polarity, other wise will damage the product. 2. Pay attention to the wire connection; wrong terminal connection will cause malfunction of the product and even damage the product;. Don t dismantle the product, and carry with care to avoiding bump and fall of the product;. If the product has been using under the environment with strong magnetic field interference, please pay attention to the shield of input wire, and the output signal wire should be as short as possible. For product intensive installation, the space between each product should not be smaller than 10mm. 5. Only use identified terminals. 6. There is no lightening strike prevention circuit design in this product. For out door and hazardous environment using, please add protective alternatives. 7. This product uses fire prevent ABS crust, its temperature withstand is only limited as +85, higher than this limitation will cause the product deformation. Please use and store carefully. Warranty: (a) Product Warranty: Seller warrants that upon Delivery the Product to be supplied by Weibo shall be completely new and shall comply in all respects with the Technical Specification confirmed with Buyer. (b) Warranty Period: Three-year warranty of free charge of repairing the product, and any purchase made in six months, Weibo will provide free charge of change and return the product if damage and problem caused by product quality. Note: Transportation fee of repaired and returned product will be borne by Buyer 6

7 Product Input-Output characteristic curve Output (ma) 2.2 20 Input (%) 0 100 120 ma~20ma Input-Output characteristic curve 7