USER MANUAL. WBI412F41 AC current transducer

Similar documents
USER MANUAL. WBI414F21 AC current transducer

USER MANUAL. WBV412U01 AC voltage transducer

Operating Instructions Differential Pressure Transducer PS27

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

OPERATOR S MANUAL 9000U ISOLATOR

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

TM3TM3 module TM3-2 temperature inputs and 1 analog output

I/O SIGNAL CONDITIONER

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 42000

VM-11 SERIES MODEL VM-11B ACCELERATION INPUT VIBRATION SIGNAL CONDITIONER INSTRUCTION MANUAL. MANUAL No E1.8. Revised in Mar.

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

TM3AI4 module TM3-4 analog inputs

CUS150M1 Instruction Manual

Installation Instructions for the ISSUE 3 RDS-DIN1 Series Single Channel Interface Module PK 80103

AS-i Safety Relay Output Module with Diagnostic Slave

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

PHOENIX CONTACT - 07/2006

AC/DC Current Probe Model SL206 USER MANUAL

TM3TI4 module TM3-4 inputs temperature

ELV12 Series. Instruction Manual

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

TM3TI4 module TM3-4 inputs temperature

Operating instructions. Switching amplifier DN0210 DN / / 2015

7032 Digital-Analog Multimeter

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Electronic Temperature Controller. Instruction Manual Version

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

LCI User Manual mantracourt.com

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Instruction Manual. T3110 T3110L T3110Ex

Setpoint Isolators. Technical Manual. HA Issue Parker SSD Drives, a division of Parker Hannifin Ltd. WARRANTY

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

I/O Expansion Box Installation & Operator s Instruction Manual

UTAH-100/XHDA SERIES

TM3TI8T module TM3-8 inputs temperature

MDM 011-Z1 Regen Resistor

Zener Barriers Bulletin 937Z

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

User's Guide. Phase Sequence and Motor Rotation Tester Model

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Operating instructions. Standstill monitor A / / 2011

AC/DC Current Probe Model SL201

BMF400 Input/output module

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

LCI Load Cell Junction Box with Fault Monitor

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Ultra Slim Relays 24

PRODUCT SPECIFICATION. PC Board Relays. Series.

Standard-Signal Isolation Amplifiers. VariTrans A 21000

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

IELR Rail-Mount Series Magnetic Circuit Protectors

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

PROGRAMMER WITH A USB LINK PD14 USER S MANUAL

INSTALLATION, OPERATION, CONFIGURATION AND MAINTENANCE MANUAL September/2016 VTT10-PH. HART TEMPERATURE TRANSMITTER panel model

EX-RC1 Remote I/O Adapter

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL

PCT2000. User Manual. Precision current transducer 2000 A

VariTrans P Standard-Signal Isolators

Transducers for Pt-100/1000, Resistors

User's Guide. Extech AM A AC Analog Clamp Meter

VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing.

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

User Manual. Stoltzen SHSP14 HDMI Splitter 1x4. 4K HDMI Splitter 1x4. All Rights Reserved. Version: SHSP14_2016V2

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

ISG Isolated DIN Rail Mount Signal Conditioner Issue: Revision A Technical User Manual

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Model 7705 Control Module

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

User s Manual Model PBL250 Logic Probe IM E. 3rd Edition

MT8050iE series. Installation Instruction (1) (2)

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

High Precision Quad Output DC Power Supply

Series 8000 RF Signal Switch Solution

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Interface and Supply module. IPC 3x0i / PSC 3x0i

PM Series Power Meter

Model CR103J. DC Current and Voltage Calibrator/Standard ±0.01µA to ± mA ±0.1µV to ± V. Operating Manual

USER MANUAL. Longo programmable controller LPC-2.ID2 RFID Card holder. Version 8

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

AS-i Safety Relay Output Module with Diagnostic Slave

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

OBSOLETE. CanWorks itrax Two-Channel Control Unit Installation. Instruction Sheet P/N A

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Transcription:

Designing, Manufacturing and Supplying WB Series Electric Isolated Sensor and Digital Electrical Transducer since 989 USER MANUAL WBI2F AC current transducer www.wb-my.com wblch@wbdz.cn Technical Service: 86 86 277827 Quality Complain: 86 86 227827 Fax Line: 86 86 2289 ISO900 ISO000 ISO8000 Certified Quality Warranty Any quality problem found in WB series products, we offer Three years free charge of repair the products, and six months guaranteed free charge of change and return the products.

2 WBI2FAC Current Transducer Safety claim The information in the safety claim of the equipment documentation is intended to ensure that equipment is properly installed in order to maintain it in a condition. It is assumed that everyone who will be associated with the equipment will be familiar with the contents of that safety section, or this safety guide. When electrical equipment is in operation, dangerous voltages will be present in certain parts of the equipment (e.g. the input terminal). Failure to obverse warning notices, incorrect use, or improper use may endanger personnel and equipment and course personal injury or physical damage. Before working in the terminal strip area, the equipment must be isolated. Proper and safe operation of the equipment depends on appropriate shipping and handling, proper storage, installation and commissioning, and on careful operation, maintenance and servicing. The operating manual for the equipment gives instructions for its installation, commissioning, and operation. However, the manual cannot cover all conceivable circumstances or include detailed information on all topics. In the event of questions or specific problem, do not take any action without proper authorization. Contact the appropriate WB technical sales office and request the necessary information. Standard application. Accuracy Accurate degree is conformed to IEC688:992 2. Safety 2. Overload capability Overload capability is conformed to IEC688:992 2.2 Isolation voltage Can be endured testing voltage is conformed to Q/7208558-0.-200 2. Insulation impedance The insulation impedance is no less than 20M Ohm, is conformed to Q/7208558-0.-200. Electromagnetic Capability. Electromagnetic field immunity test according to IEC 6000--:995.2 Power frequency magnetic field immunity test according to IEC 6000--8:99 Product Description and Application WBI2F converts AC input current into a load independent output signal DC voltage 0-5V or -5V. It has adopted electromagnetic isolation principle for real time measurement of AC current (sine wave) from electric net or electric circuit. 2

The product has certain advantages of total galvanic isolation between input/output and auxiliary power, high accuracy, low drifting by temperature, and wide temperature bearable range, etc. Function realization schematic drawing + In Out _ +E G Product Dimensional Drawing (unit: mm) Input Current Direction Output Terminal DIN Mounting Rail Spring Clasp Product Terminal Identification Drawing 2 Auxiliary Power(+E) Auxiliary Power and Ground(GND) Output(V Z ) Measuring current input (through window) Non-identified terminals cannot be used!

Key Technical Data:. Input: 50 600A; 2. Output: 0-5V,or -5V. Accuracy : 0.2%. frequency range: 25Hz~5kHz 5. Input Impedance (R): Measuring current<00ma, input impedance 200Ω; Measuring current 00mA, input impedance approximate zero 6. Linear Range:0-20% of nominal input 7. Responding Time: 00ms 8. Over Load Capacity: 0 times of nominal input, for 5 seconds; 9. Maximum Load: 5mA 0. static current: ma(0-5v); 7mA(-5V). Auxiliary Power:+2V/+5V/+2V,dc 2. Isolation Voltage: 2500Vdc, for minute. Output Ripple: <6mV(root-mean-square value, output load is 250Ohm). Drifting by Temperature:.5 0 - / (0-5V);.0 0 - / (-5V) 5. Ambient Temperature: 0 ~+50 (Commercial Grade) -25 ~+70 (Industrial Grade) 6. Mounting : DIN Rail 5mm Mounting Instruction of Installation and Use. The product has adopted structure compliance with EN50022; suitable for DIN rail mounting NS5/7.5, NS5/5. Installation steps are as following (please reference to dimensional drawing): Step : Immobilize one side of product s mounting trough to the DIN mounting rail; Step 2: Pull out the spring clasp; Step : Place whole mounting trough to the DIN mounting rail properly; Step : Release spring clasp to make sure the installation. 2. The product has calibrated before out of factory. After correctly wiring, it can be powered and used immediately. But for further precise signal sampling, user needs to warm-up the product for minutes before use. a) the auxiliary power requires isolation voltage 2000V AC, DC current output ripple <0mV, and multiple converters can share with one set auxiliary power together.. The Maximum volume of line for the transducer terminal is 2.5mm 2 ; the insulation layer of the line should be peeled off about 8mm~0mm and tightly twisted to connect with the transducer terminals.. For less than 0A AC current measurement, it may adopt ampere-turn method for input and for this time, the resolution of the transducer increases and measuring range narrows, but other technical index may not be affected. 5. Basic testing method for accuracy

5 () According to the terminal definition table to connect the testing circuit; (2) The testing must to be done by under the following conditions; Auxiliary power: ±0.5%,ripple 5mV Ambient temperature: 25 ±2 Relative humidity: RH(5~75)% Accuracy for Signal Power Source instrument: 0.05 Auxiliary Power + V - + Power Source R V2 Transducer - Caution: () Warming up the transducer for minutes () Using output monitoring meter V to measuring the output of signal power source instrument, set any input value which is within the measuring range of the transducer Ir. (e.g. if input value is 50A, the output is 0V~5V, the expected output value Vz should be calculated as: Vz = 5V Ir/50A) (5) Using output monitoring meter V2 to measuring the output voltage V0 of the transducer, the basic introduced errorγof the transducer should be calculated as:γ= (Vo-Vz)/5V 00 (6) Repeating step () (5), if calculated absolute value is less than the given accuracy value of the transducer, it shows the transducer s accurate grade is qualified.. Pay attention to the auxiliary power information, especially the auxiliary power grade, and polarity, other wise will damage the product. 2. Pay attention to the wire connection; wrong terminal connection will cause malfunction of the product and even damage the product; 5

6. Don t dismantle the product, and carry with care to avoiding bump and fall of the product;. If the product has been using under the environment with strong magnetic field interference, please pay attention to the shield of input wire, and the output signal wire should be as short as possible. For product intensive installation, the space between each product should not be smaller than 0mm. 5. Only use identified terminals. 6. There is no lightening strike prevention circuit design in this product. For out door and hazardous environment using, please add protective alternatives. 7. This product uses fire prevent ABS crust, its temperature withstand is only limited as +85, higher than this limitation will cause the product deformation. Please use and store carefully. Warranty: (a) Product Warranty: Seller warrants that upon Delivery the Product to be supplied by Weibo shall be completely new and shall comply in all respects with the Technical Specification confirmed with Buyer. (b) Warranty Period: Three-year warranty of free charge of repairing the product, and any purchase made in six months, Weibo will provide free charge of change and return the product if damage and problem caused by product quality. Note: Transportation fee of repaired and returned product will be borne by Buyer Product Input-Output characteristic curve 6 5 Output (V) Output (V) 5.8 5 Input (%) Input (%) 0 00 20 0 00 20 0V~5V output V~5V output 6