Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Similar documents
Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

OPERATION MANUAL TOS5052 DANGER

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

HV-CS kv Edge Mount Triaxial Jack

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Model 7705 Control Module

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

POCKET MULTIMETER Model No: MM18

User Guide True RMS Multimeter Extech EX205T

AutoRanging Digital MultiMeter

ETHOS Auto Ranging Digital Multimeter

Model A Mini AC/DC Clamp Meter. User's Guide

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

DM3058/DM3058E Digital Multimeter

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Model 2657A-LIM-3 LO Interconnect Module

OPERATING INSTRUCTION

User's Guide. MiniTec TM Series Model MN25 MultiMeter

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

Model R5010. TRMS Digital Multimeter. Instruction Manual

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

Digital Clamp Meter User Manual

80W (16V/5A) Power Supply with USB Output. User Manual

Model 2380 Rack-Mount Kit

9040/9040UK. Users Manual. Phase Rotation Indicator

User's Guide. Extech AM A AC Analog Clamp Meter

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Autoranging True RMS Multimeter User Manual

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

2260B-RMK-Series Rack Mount Kit

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

Autoranging Mini Multimeter

Mini Digital Multimeter

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

Digital Multimeter User's Manual

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

User's Guide. Digital Multimeter. Model MN42

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL

ELV12 Series. Instruction Manual

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

User s Guide. 600A AC Clamp Meter. Model 38387

PCT2000. User Manual. Precision current transducer 2000 A

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

Mini Digital Multimeter

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

Model 2380 Rack-Mount Kit

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Single Kernel Grain Moisture Tester PQ-520. (type PQ ) Operating Instructions

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

AC Power Meter GPM-8212 USER MANUAL

HI-POT TESTER User Manual

HI-POT TESTER. User s Manual

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Mini Digital Multimeter Model MN15. User's Guide

High Precision Quad Output DC Power Supply

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

USER'S MANUAL DCL-650

Operating Instructions

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Mini Digital Multimeter

EC Series. Safety Guide

700 Series 200 Amp Clamp Meters

Operating Instructions

User's Guide. Phase Sequence and Motor Rotation Tester Model

User s Manual Power Supply IM E. 5th Edition

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

PRO-1250D CT MID DIN rail three phase four wire energy meter.

3700 SERIES USER MANUAL

Demonstration Case BENNING DB 1

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Operating instructions. Speed monitor D / / 2014

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

DC POWER SUPPLY. Model: PW-3063R / PW-4063R

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

PRO-75 SERIES. User manual

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

2016 SIGLENT TECHNOLOGIES CO.,LTD

User's Guide. Model W 3-in-1 Switching DC Power Supply

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

Laboratory Switch Mode Power Supply Series. Instruction Manual

Transcription:

Part No. Z1-109-820, IA001705 Jul. 2016 OPERATION MANUAL High Voltage Digitalmeter 149-10A

Use of Operation Manual Please read through and understand this Operation Manual before operating the product. After reading, always keep the manual nearby so that you may refer to it as needed. When moving the product to another location, be sure to bring the manual as well. If you find any incorrectly arranged or missing pages in this manual, they will be replaced. If the manual gets lost or soiled, a new copy can be provided for a fee. In either case, please contact Kikusui distributor/agent, and provide the "Kikusui Part No." given on the cover. This manual has been prepared with the utmost care; however, if you have any questions, or note any errors or omissions, please contact Kikusui distributor/ agent. Reproduction and reprinting of this operation manual, whole or partially, without our permission is prohibited. Both unit specifications and manual contents are subject to change without notice. Copyright 1994 Kikusui Electronics Corporation.

Power Requirements of this Product Power requirements of this product have been changed and relevant sections of the Operation Manual should be revised accordingly. (Revision should be applied to items indicated by a check mark.) Input voltage The input voltage of this product is Vac, and the voltage range is to Vac. Use the product within this range only. Input fuse The rating of this product's input fuse is A, Vac, and. WARNING To avoid electrical shock, always disconnect the power cord or turn off the switchboard before attempting to check or replace the fuse. Use a fuse element having a shape, rating, and characteristics suitable for this product. The use of a fuse with a different rating or one that short circuits the fuse holder may result in fire, electric shock, or irreparable damage. 149-10A 1

Power Requirements of this Product (cont'd) Power cord The product is provided with power cords described below. If the power cord has no plug, attach a plug or crimp -style terminals to the power cord in accordance with the wire colors specified in the drawing. WARNING The attachment of a plug of power cord or crimp-style terminals must be carried out by qualified personnel. Without a plug Blue (NEUTRAL ) Brown (LIVE) Without a plug White (NEUTRAL) Black (LIVE) Green/Yellow (GND) Green or Green/Yellow (GND) Plug for USA Plug for Europe Plug for China Provided by Kikusui distributor/agent Kikusui agents can provide you with suitable power cord. For further information, contact Kikusui distributor/agent. 2 149-10A

Safety Precautions The following safety precautions must be observed to avoid fire hazard, electrical shock, accidents, and other failures. Keep them in mind and make sure that all of them are observed properly. Operation Manual Users This product must be used only by qualified personnel who understand the contents of this operation manual. If it is handled by disqualified personnel, personal injury may result. Be sure to handle it under supervision of qualified personnel (those who have electrical knowledge.) This product is not designed or manufactured for general home or consumer use. Purposes of use Do not use the product for purposes other than those described in the operation manual. Line Voltage Input power Use the product with the specified input power voltage. For applying power, use the power cord provided. Note that the provided power cord is not use with some products that can switch among different input power voltages or use 100 V and 200 V without switching between them. In such a case, use an appropriate power cord. For details, see the relevant page of this operation manual. 149-10A 3

Fuse With products with a fuse holder on the exterior surface, the fuse can be replaced with a new one. When replacing a fuse, use the one which has appropriate shape, ratings, and specifications. Cover There are parts inside the product which may cause physical hazards. Do not remove the external cover. L N G Installation To avoid electrical shock, connect the protective conductor terminal to electrical ground (safety ground). When installing products with casters, be sure to lock the casters. Relocation Turn off the power switch and then disconnect all cables when relocating the product. Use two or more persons when relocating the product which weights more than 18 kg. The weight of the products can be found on the rear panel of the product and/or in this operation manual. Use extra precautions such as using more people when relocating into or out of present locations including inclines or steps. Also handle carefully when relocating tall products as they can fall over easily. Be sure the operation manual be included when the product is relocated. 4 149-10A

Check? Operation Check that the AC input voltage setting and the fuse rating are satisfied and that there is no abnormality on the surface of the power cord. Be sure to unplug the power cord or stop applying power before checking. If any abnormality or failure is detected in the products, stop using it immediately. Unplug the power cord or disconnect the power cord from the switchboard. Be careful not to allow the product to be used before it is completely repaired. For output wiring or load cables, use connection cables with larger current capacity. Do not disassemble or modify the product. If it must be modified, contact Kikusui distributor/agent. Maintenance and checking To avoid electrical shock, be absolutely sure to unplug the power cord or stop applying power before performing maintenance or checking. To maintain performance and safe operation of the product, it is recommended that periodic maintenance, checking, cleaning, and calibration be performed. Service Internal service is to be done by Kikusui service engineers. If the product must be adjusted or repaired, contact Kikusui distributor/agent. 149-10A 5

Safety Symbols This operation manual and this product use the following safety symbols. Note the meaning of each of the symbols to ensure safe use of the product. (As using symbols depend on the product, all of symbols may not be used.) or WARNING CAUTION NOTE Description Indicates the presence of 1000V or higher. Inadvertently touching such a part may cause electrical shock resulting in death. If it is necessary to touch such a part to conduct work, first make sure no voltage is being supplied. Indicates the possibility of personal injury or death. Never fail to follow the operating procedure. Do not proceed beyond a WARNING sign until the noted conditions are fully understood and met. Indicates the existence of damage to the product or connected equipment. Always follow the operating procedure. Do not proceed beyond a CAUTION sign until the indicted conditions are fully understood and met. Indicates additional information such as operating procedure. Describes technical terms used in this manual. Indicates action prohibited. Indicates general warning, caution, risk of danger. When this mark is indicated on the product, refer the relevant section of the Operation Manual. Indicates a protective conductor terminal. Indicates a chassis (frame) terminal. 6 149-10A

Contents Power Requirements of this Product 1 Safety Precautions 3 Safety Symbols 6 Chapter 1 General Description 8 Chapter 2 Preparation 9 2.1 Receiving Inspection 9 2.2 AC Line Requirements 9 2.3 Connecting the Power Cord 10 Chapter 3 Operation Method 11 3.1 Part Names and Functions 11 3.2 Measuring Method 12 3.2.1 Measuring Procedure 12 3.2.2 To Correct the Meter Reading for High Impedance Measured Object 14 3.2.3 Measured Object's Polarity and Ground 14 Chapter 4 Specifications 16 Chapter 5 Calibration 17 5.1 Calibration of Digitalmeter 17 5.2 Replacing the Fuse 18 Chapter 6 Block Diagram 19 149-10A 7

Chapter 1 General Description Kikusui Model 149-10A High Voltage Digitalmeter measures AC and DC voltages of up to 10 kv, with a high accuracy. As the meter input impedance is as high as 1000MΩ, the meter is best suited for measurement of voltages of high source impedance circuits. The meter is compact and light (approx.3kg), but its measuring accuracy is high. Thus the meter can also be used conveniently as a portable calibration instrument or to calibrate the voltage of a withstanding voltage tester. 8 149-10A

Chapter 2 Preparation 2.1 Receiving Inspection Immediately upon receipt of the product, inspect it for any damage which might have been sustained while in transportation. If any signs of damage are found, contact Kikusui distributor/agent. 2.2 AC Line Requirements Before turning on the POWER switch of the tester, be sure that your AC line voltage. The AC line requirements of the tester are as follows: Nominal voltage: 100 V Voltage tolerance: ±10 % of nominal voltage Nominal frequency: 50/60 Hz Testers that operate on other AC line voltages as shown below also are available as factory-modification options. 110 V, 120 V, 220 V, 230 V, or 240 V The following table is printed on the rear panel of the tester. If nothing is marked in the "LINE VOLTAGE" column, the nominal voltage is 100 V. If a change has been made, a mark is indicated to the left of the corresponding voltage. LINE VOLTAGE STANDARD 100 V 110 V 120 V 220 V 230 V 240 V FUSE 250V 0.5A 250V 0.3A 149-10A 9

2.3 Connecting the Power Cord This product is designed as an equipment of IEC Overvoltage Category II (energy-consuming equipment supplied from a fixed installation). WARNING Risk of electric shock. This product is IEC Safety Class I equipment (equipment with a protective conductor terminal). To prevent electric shock, be sure to connect the protective conductor terminal of the product to electrical ground (safety ground). The product is grounded through the power cord ground wire. Connect the protective conductor terminal to earth ground. NOTE Use the supplied power cord to connect to the AC line. Do not use the supplied power cord with other instruments. The power cord with a plug can be used to disconnect the product from the AC line in an emergency. Connect the plug to an easily accessible power outlet so that the plug can be removed from the outlet at any time. Secure adequate space around the power plug. Do not insert the power plug to an outlet where accessibility to the plug is poor. And, do not place objects near the outlet that would result in poor accessibility to the plug. 1. Turn off the POWER switch. 2. Check whether or not the AC line is compatible with the input rating of the the tester. See section 2.2, "AC Line Requirements." 3. Connect the power cord to the AC inlet (AC LINE) on the rearpanel. 4. Connect the power cord plug to an outlet with a ground terminal. 10 149-10A

Chapter 3 Operation Method 3.1 Part Names and Functions Plastic screw Fixes the test lead (red). Voltmeter Indicates the measured voltage. AC/DC Mode selection switcch LEDs indicate selected mode. CALIBRATION (AC/DC) Semi-fixed resistors for calibration Do not touch these resistors except when calibrating the meter. POWER AC power switch LOW Terminal for ground line of measured input voltage INPUT Terminal for high potential line of measured input voltage LINE VOLTAGE/FUSE Indicates the AC line voltage and fuse rating of the meter. FUSE Input power fuse Protective conductor terminal AC LINE Connect the supplied power cord here. Fig.3.1 Front panel/rear panel 149-10A 11

3.2 Measuring Method 3.2.1 Measuring Procedure WARNING For measurement of 5 kv or higher voltage, be sure to use the HTL2.5DH high voltage test lead. Be sure to connect securely between the 149-10A and the measured object with the supplied high voltage test leads. Note that, if the low voltage test lead is accidentally disconnected while the high voltage is being input, electric shock hazards may be caused or the meter may be seriously damaged. NOTE To measure with highest accuracy, warm up the 149-10A for at least 15 minutes. If the 149-10A is used in dusty atmosphere or the meter is used continuously for a long time with a high voltage being input, dust may be collected on the INPUT terminal section. Because input resistance degradation or voltage dividing ratio disturbance, clean at appropriate intervals the INPUT terminal and the internal insulators using a clean, dry cloth. The AC/DC converter of the 149-10A is a mean-value response system and is calibrated with the rms value of sine wave. Therefore, that errors may be caused if the measured voltage waveform is largely different from sine wave. 1. Turn on ( ) the POWER swich. 2. Connect the supplied high voltage test lead (black) to the LOW terminal of the tester as shown in Fig. 3.2. LOW terminal Put the test lead clamp like this. High voltage test lead (black) Fig. 3.2 Low terminal connection 12 149-10A

3. Connect the supplied high voltage test lead (black) to the low voltage side (GND side) of the measured object. If the low voltage side (GND side) of the measured object is unknown, see section 3.2.3, "Measured Object's Polarity and Ground." 4. Insert the end of the supplied high voltage test lead (red) for a sufficient length in the INPUT terminal of thr tester, and fix the lead with the plastic screw. 5. Set the AC/DC switch in accordance with the output of the measured object. 6. Connect the supplied high voltage test lead (red) to the high voltage side of the measured object. 7. Check that the 149-10A and measured object are connected as shown in Fig. 3.3. 8. Turn on the power of the measured object. 149-10A A B Measured object Ground Ground Ground the low voltage side. High voltage test lead TL05-TOS or HTL2.5DH (5 kv or more) Fig. 3.3 Connection for measuring 149-10A 13

3.2.2 To Correct the Meter Reading for High Impedance Measured Object The 149-10A input impedance is very high (1000MΩ). When the internal impedance of the measured object is substantially high, however, errors can be caused. In such a case, make correction calculation as follows: E = Eo ( 1+ γo 1000M ) where, E : True voltage Eo : Meter reading γo : Internal impedance of measured object In most cases the value of internal impedance (γo) is unknown. In such cases, use the above equation as follows: When γo 10 MΩ for example, Eo < E 1.01 x Eo As above, when the internal impedance is lower than 10MΩ, the error caused impedance-wise is less than 1%. Measurement can be done with an accuracy of this error plus meter accuracy. 3.2.3 Measured Object's Polarity and Ground Be sure to connect the power cord of the 149-10A to a properly grounded outlet. If grounding is not possible through the power cord, ground the (protective conductor terminal) on the rear panel. As shown in Fig. 3.4, if the 149-10A is not grounded and the low and high voltage sides of the measured object are connected in reverse, the applied high voltage may damage the inside of the meter. 149-10A No ground A B Measured object A: High voltage side B: Low voltage side Ground High voltage test lead Fig. 3.4 Improper connection 14 149-10A

If the 149-10A is grounded in Fig.3.4, terminals A and B of the measured object are shorted through the ground and the measured object is adversely affected. As such, if the low voltage side (GND side) of the measured object is unknown, determine it by following the procedure below, and connect properly. How to determine the polarity of the measured object As shown in Fig. 3.5, connect a high voltage test lead to terminal A or B, and assume the side with the higher voltage reading to be the high voltage side. 149-10A Ground A B Measured object High voltage test lead Fig. 3.5 Polarity check 149-10A 15

Chapter 4 Specifications Item Power requirements Measuring ranges Measuring accurancies Maximum allowable input voltages Display Type of voltmeter Input resistance Ambient temperature and humidity: Overall Dimentions 100V±10%, 50/60 Hz AC, approx. 10VA 0.500 to 10.000 kv AC/DC AC: ±(1% of rdg + 0.05% of range) DC: ±(0.5% of rdg + 0.03% of range) at 23 C±10 C *(for sine wave, at 50 to 60 Hz) AC : 11kV rms (sine wave, 50 to 60 Hz) DC : ±14 kv Pulse : 15 kv peak 7-segment LEDs Double integration type. For AC measurement, mean value response, sine wave rms value calibration. 3 samples/sec 0 C to 35 C (32 F to 95 F), 80% RH External dimensions : Maximum dimension Specification Weight Accessories Approx. 3 kg (6.6 lbs) Power cord 1 TL05-TOS High voltage test leads 1 set HTL2.5DH High voltage test lead 1 Operation manual 1 16 149-10A

Chapter 5 Calibration 5.1 Calibration of Digitalmeter Calibrate the 149-10A once a year or more frequently. Instruments required for calibration To calibrate the 149-10A covering its all measuring ranges, a standard voltage generator which will provide the following voltages is required. AC: 10 kv ± 0.1% DC: 10 kv ± 0.05% If you cannot prepare an above standard voltage generator, calibrate the 149-10A with a calibrator which can generate the voltage range which you use, or order Kikusui distributor/agent for calibration. Notes before calibration As a high voltage of 10 kv is dealt with when calibrating the 149-10A, pay full attention for safety. Before calibration, warm up the 149-10A for at least 60 minutes. Calibration Set the 149-10A in the DC mode, apply a calibration voltage of 10 kv DC to the input terminal of the meter, and so adjust CALIBRATION (DC) semi-fixed resistor on the side panel of the 149-10A that it displays 10.000. Next, set the 149-10A in the AC mode, apply a calibration voltage of 10 kv AC, and so adjust the CALIBRATION (AC) semi-fixed resistor that the 149-10A displays 10.000. When doing this, the displayed value may change by about three digits. For calibration, use the center value. When adjustment for DC measurement is done, the voltage dividing ratio of the input circuit varies. Be sure to perform the DC calibration first. 149-10A 17

5.2 Replacing the Fuse WARNING To avoid electric shock, always turn off the POWER switch and unplug the power cord from an outlet before replacing the fuse. Make sure that the replacement fuse is of the correct shape, and rating for mater specifications. Never use a fuse having a different rating; never short-circuit the fuse holder. 1. Turn off the POWER switch and unplug the power cord from the outlet. 2. Disconnect the power cord from the AC inlet on the rear panel. 3. Use a screwdriver to remove the fuse holder, as shown in Fig. 5.1. Fuse Fig. 5.1 Fuse holder 18 149-10A

Chapter 5 Block Diagram 149-10A 19

KIKUSUI ELECTRONICS CORP. 1-1-3 Higashiyamata, Tsuzuki-ku, Yokohama, 224-0023, Japan Tel: +81-45-593-7570 Fax: +81-45-593-7571 Website http://www.kikusui.co.jp/en