Smart and simple cabling solutions Patchcords & preterminated links Accurate solutions for tailored cabling
MMC, INNOVATION background for many years Since 1993, Multimedia Connect has been a structured cabling system manufacturer designing and producing communication solutions for intelligent buildings, that enhances IP convergence. Quality & innovation are the directions chosen by Multimedia Connect to offer accurate cabling from Enterprise to Datacenter. Headquarter Bare fiber factory MMC s tailored preterminated patchcords and fiber links are assembled in our dedicated production line, using MMC s selected components and production process This ensures a maximum continuity in quality standard, checking & follow-up. Installers and users are confident because our tailored production is also included into the Multimedia Connect 25 years warranty. Services provided by our production line: Wide range of cables & connectors combinations Customized length and connections Customized jacket marking Wide range of fan out kits (epoxy less) Several types of pulling eyes according to pulling conditions 3 degrees of inspections (db meter, OTDR, Interferometer test report) 25 years warranty on factory preassembled items* MTP TM cassettes and MTP TM trunks Other types of preterms Loaded panels (splice tray, pigtails, adapters, labels ) *If installed by a MMC certified company 3
GOOD TO KNOW to select your fiber link CHOICE A large range with combinations of cables, connectors and pulling protections dedicated to every type of pulling environments. MMC aluminum pulling protection SERVICE A short lead time thanks to a wide stock of available components for an optimum reactivity and lean production process for the highest productivity. P/N : P06I10SCSCOS2 Indoor OS2 6FO 10m SC/SC preterm Tracking by S/N stickers QUALITY A tailored industrial process allows the best possible repeatability for the most stable quality. Fiber link must be choosen considering many different properties but the main point is application environment and location. Knowing where the cable is installed helps to define mechanical or environmental properties which then will determine the cable design & protection. MECHANICAL CRUSH RESISTANCE PULLING RESISTANCE TWISTING BENDING RADIUS RODENT RESISTANCE ENVIRONMENTAL WATERPROOFNESS FLAME BEHAVIOR U.V. RESISTANCE OPERATING TEMPERATURE As far as performances are concerned, bit rate flow and lengh of the link give a matrix to choose fiber type that will answer your need. A new parameter is becoming more and more important, especially for datacenter or in-building installation. It is called "Flexibility", the bending immunity is the key for short space installation. TRANSMISSIONS BENDING PERF. 100MB 1GB 10GB 40GB 100GB 850nm 1300nm 1550nm OM1 62.5/125µm 2000m 220m 32m - - - - - SINGLEMODE MULTIMODE OM2 OM3 OM3 OM4 OM4 OS2 50/125µm 50/125µm 50/125µm Low bending 50/125µm 50/125µm Low bending 9/125µm G652D G657A1 9/125µm Low bending G657A2 9/125µm Not compatible OS2 G657B3 9/125µm Not compatible OS2 2000m 550m 86m - - 2000m 550m 300m 100m - 2000m 550m 300m 100m - 2000m 550m 550m 125m - 2000m 550m 550m 125m - - - - 10 000m 10 000m - - - 10 000m 10 000m - - - 10 000m 10 000m - - - 10 000m 10 000m - - - - - - < 0,1dB (15mm Ø) < 0,3dB (15mm Ø) - - - < 0,2dB (7.5mm Ø) < 0,4dB (7.5mm Ø) - - - - - - - < 0,25dB (15mm Ø) < 0,1dB (10mm Ø) - - < 0,15dB (5mm Ø) - - 4
Fiber links are used in many different configurations: indoor, outdoor or in/out of the building. Installation method helps choosing a cable with enough protection or with the right fire behavior. The main fiber links are illustrated in the below drawing. : Local Area Network MAN : Metropolitan Area Network : Storage Area Network WAN : Wide Area Network indoor BUILDING ENTERPRISE DATACENTER IN/OUT PARKING WAREHOUSE PRODUCTION PT OUTDOOR & MAN CAMPUS MAN & WAN TELECOM CITY NETWORKS 5
db 0 10 20 30 40 50 60 km 0,00 0,05 0,10 0,15 0,20 0,25 0,30 0,35 0,40 0,45 0,50 A B PRETERMS SELECTION GUIDE AVAILABLE TYPES OF TEST REPORTS INCLUDED WITH THE PRETERMS OPTIONAL db meter (under 100 m) OTDR (beyond 100 m) Interferometer MMC 51400643 1300 006.SOR 1.0 km/0,050 m A: 0,2979 km B: 0,4058 km A -> B: 0,1080 km Indice: 1.491000 Perte 2-Points: 0,358 db Réflectance: -52.35 db [H] 10ns / 1.0m Moy: Rapide 5120 /1300 nm/mm Minimum criterias for short lenght with no detailed events (without reflectance) -------------------- Page 1 -------------------- Language: FR ] [ [ Cable ID: P06S100SCSCOM2 ] [ Fiber ID: 6 ] [ Wavelength: 1300 ] [ Org. Loc: ] [ Term. Loc: ] [ Cable Code: 14280123 ] [ Condition: OT ] [ Operator: ] [ Comment: ] [ Supplier: Anritsu ] [ OTDR Model: MT9083A-063 ] [ S/N: 6200899403 ] [ Mod: ] Optics [ S/N: ] [ Rev.: ] S/W 5.30 [ Other: ] -------------------------------------------------- The precise test to locate every event occuring all along the link. The high class test of connector polished surface and geometry for top performance insurance. race Primaire: MMC 51400643 1300 006.SOR Date: 07/09/14 Calibre: 1.0 km Heure: 03:19 PM Résolution: 0,050 m Type Appareil: MT9083A-06 L. Impulsion: 10 ns 1.491000 Module opt.: Indice: Type Fibre: d'onde: 1300 Multimode L. nm Seuils FAS: Offset Horz.: 0.0000 km Perte: Offset Vert.: 0.00 db 0.10 db Réflectance: -65.00 db Balayages: 5120 Rupture Fibre: 3.00 db Rétrodiff.: -74.00 vertissements: Analyse ORL: N/D CABLING SPECIFICATIONS Type de Trace: Anr SR4731 Résultats d'analyse -- MMC 51400643 1300 006.SOR Evén. Position Entre Evén. Perte Réfl #/Type (km) (db) (db/km) (db) (db) 1/R 0.0978 0.20 2.025 0.06(2P) -48.90 2/R 0.2976 0.12 0.617 0.19(2P) -52.35 3/R 0.3987 0.22 2.199 0.05(2P) -52.56 ENVIRONMENT Networks 4/E 0.6005 0.17 0.841 >3.00-14.75 Atténuation totale: 1.01 db PULLING / INSTALLATION preterms Structure & jacket INDOOR Uncoiling medium distances Horizontal/vertical I (Indoor) Mini break-out Tight buffered LSZH (MULTI IE) IN/OUT Easy pulling Campus aerial Horizontal Campus in duct Tough pulling conditions S (Standard) P (Premium) Loose tube LSZH (INTEX) Loose tube LSZH (INTEX) OUTDOOR, MAN & INDUSTRY, MAN & INDUSTRY Campus in duct or aerial Tough pulling conditions Campus in duct or buried Mechanical risks E (Outdoor) A (Armoured) Loose tube PEHD (EXT/CT) Loose tube steel tape armoured PEHD (EXTAL) & Easy pulling and/or uncoiling Risk of data loss M (Micro) Micro break out Tight buffered LSZH (MICRO 3mm) Easy pulling and/or uncoiling Between 2 cabinets N (Nano) Rigid PA12 LSZH (NANO 2mm) INDOOR Uncoiling on short distances Between 2 cabinets MTP TRUNK (Standard MTP TM ) Micro break out tight buffered simple jacket (LSZH) Uncoiling on medium distances Between 2 cabinets MTP RUG (Ruggedized MTP TM ) Micro break out tight buffered double jacket (MICRO 3mm) Patching Direct patching MTP FAN (Distribution MTP TM ) Micro break out tight buffered double jacket (MICRO 3mm) 6
WHich CONNECTIVITY FOR EACH SIDE MAIN UPC (Ultra Polished Connector) CONNECTOR TYPES The ST connector has a bayonet insertion process ST (2,5mm ferule) The FC connector has a screwable insertion process FC (2,5mm ferule) The SC connector has a push-pull insertion process The LC connector has a latch insertion process LC (1,25mm ferule) SC (2,5mm ferule) SFF (Small Form Factor) MAIN APC (Angled Polished Connector) CONNECTOR TYPES The APC connectors are the same has PC, SPC and UPC above but the polished surface is made with 8 angle ST-APC FC-APC SC-APC LC-APC PRETERM SOLUTIONS Pictures of cables Fan out Pulling eye / protection Pulling force max. Crush NONE 400N 2000N CORRUGATED PVC 800N 2000N STANDARD EPOXYLESS CORRUGATED PVC 1500N 2000N PREMIUM EPOXYLESS ARMOURED CLEAR PVC 1500N 4000N PREMIUM EPOXYLESS ARMOURED CLEAR PVC 1500N 5000N PREMIUM EPOXYLESS ARMOURED CLEAR PVC 200N 1000N MICRO EPOXYLESS FLEXIBLE POLYAMIDE STANDARD ABS + EPOXY NONE (UNCOILED) 160N 950N (12FO) 700N (24FO) NONE 150N 1000N FLEXIBLE POLYAMIDE NONE 400N 1000N FLEXIBLE POLYAMIDE STANDARD ABS + EPOXY NONE (UNCOILED) 150N 1000N 7
PATCHCORDS SELECTION GUIDE ENVIRONMENT NETWORK PULING / INSTALLATION LENGTHS RESISTANCE PATCHCORDS PATCHING From 1M to 10M S (Simplex) D (Zipcord duplex) INDOOR BACKBONE From 10M to 50M FD (Flat duplex) BACKBONE AND/OR DISTRIBUTION BETWEEN 2 CABINETS From 50M to 100M RRD (Reinforced INDUSTRIAL TACTICAL LINKS MECHANICAL RISKS 100M & more ARD (Armoured IN/OUT INDUSTRIAL & TACTICAL LINKS MECHANICAL RISKS 100M & more AURD (Armoured uniboot TACTICAL LINKS BETWEEN 2 OVERLOADED CABINETS From 1M to 15M URD (Uniboot OVERLOADED CABINETS LINKS BETWEEN 2 CABINETS From 1M to 20M LED (LED patchcords) INDOOR OVERLOADED CABINETS From 1M to 15M LBSB (Low bending short boot) STRATEGIC LINKS BETWEEN 2 CABINETS OVERLOADED MECHANICAL RISKS From 1M to 25M LBUD (Low bending uniboot duplex) WAN PATCHING INTO TELECOM, BROADBAND & GSM CABINETS From 1M to 15M SHG (Simplex High grade) DHG (Duplex High grade) FLEXIBILITY PULLING FORCE CRUSH RESISTANCE 8
CABLES PICTURES OF CABLES PICTURES OF PATCHCORDS AVAILABLE FIBERS COLORS AVAILABLE CONNECTORS ZIPCORD DUPLEX Ø 3 mm OM1 ORANGE OM2 ORANGE OM3 AQUA OM4 ERICA VIOLET OS2 YELLOW ALL TYPES OF CONNECTORS FLAT DUPLEX 2.8 mm x 5.6 mm OM1 ORANGE OM2 ORANGE OM3 AQUA OM4 ERICA VIOLET OS2 YELLOW ALL TYPES OF CONNECTORS REINFORCED ROUND DUPLEX Ø 5.6 mm MOQ ALL TYPES OF CONNECTORS ARMOURED ROUND DUPLEX Ø 3.2 mm OM2 GREY OM3 AQUA OM4 ERICA VIOLET OS2 BLUE ALL TYPES OF CONNECTORS ARMOURED ROUND DUPLEX Ø 3.2 mm OM2 GREY OM3 AQUA OM4 ERICA VIOLET OS2 BLUE LC ONLY ROUND DUPLEX Ø 3 mm MOQ LC ONLY EXCLUSIVE FLAT DUPLEX 3 mm x 5.2 mm OM3 AQUA OM4 ERICA VIOLET OS2 YELLOW LC AVAILABLE. MOQ FOR ST & SC LOW BENDING ZIPCORD DUPLEX Ø 2 mm OM3 AQUA OM4 ERICA VIOLET LC 1 OR 2 SIDES LOW BENDING ROUND DUPLEX Ø 3 mm MOQ LC ONLY LOW BENDING ZIPCORD DUPLEX Ø 1.6mm G657 A1, A2, B3 YELLOW SC, SC-APC, FC, FC-APC, LC, LC-APC 9
ORDERING INFORMATION CLASSICAL PRETERMS PRETERMS NUMBER OF FIBER TYPES OF PRETERMS LENGTH (M) END A END B PERFORMANCES P XX X XXXX XXX XXX XXX 4 6 8 12 24 I (Indoor) S (Standard) P (Premium) E (Outdoor) A (Armoured) M (Micro) N (Nano) 1 to... ST ST OM1 FC FC OM2 SC SC OM3 LC LC OM4 SCA (SC-APC) FCA (FC-APC) LCA (LC-APC) E2 (E2000) E2A (E2000-APC) SCA (SC-APC) FCA (FC-APC) LCA (LC-APC) E2 (E2000) E2A (E2000-APC) OS2 (G652D) 7A1 (G657 A1) 7A2 (G657 A2) 7B3 (G657 B3) MULTIMODE SINGLEMODE MU MU MTP PRETERMS MTP TM LINK (END A) TYPES OF PRETERMS NUMBER OF FIBER LENGTH (M) END B (Only for FAN & FAN C) MTP XXXXX XX XXX XXX XXX PERF. TRUNK (single jacket micro cable) RUG (double jacket micro cable) C (Corrugated armour) FAN (MTP 12 fo /12-24 LC double jacket micro cable) FAN C (MTP 12 fo / 12-24 LC corrugated armour) 12 Less than 10m ST OM1 24 More than 10m SC OM2 LC SCA (SC-APC) LCA (LC-APC) E2 (E2000) E2A (E2000-APC) OM3 OM4 OS2 (G652D) 7A1 (G657 A1) 7A2 (G657 A2) 7B3 (G657 B3) MULTIMODE SINGLEMODE 10
PATCHCORDS PATCHCORDS TYPE OF END A END B LENGTH (M) PERFORMANCES PATCHCORDS J XXX XXX XXX XXXX XXX ST ST 1 to 999 FC SC LC SCA (SC-APC) FCA (FC-APC) LCA (LC-APC) E2 (E2000) E2A (E2000-APC) MU FC SC LC SCA (SC-APC) FCA (FC-APC) LCA (LC-APC) E2 (E2000) E2A (E2000-APC) MU S (Simplex) D (Duplex) FD (Flat duplex) RRD (Reinforced AD (Armoured duplex zipcord) ARD (Armoured AURD (Armoured uniboot URD (Uniboot LED (With led ID) LBSB (Low bending short boot) LBUD (Low bending uniboot duplex) SHG or DHG (High grade) OM1 (62.5/125µm) OM2 (50/125µm) OM3 (50/125µm) OM4 (50/125µm) OS2 (G652D) 7A1 (G657 A1) 7A2 (G657 A2) 7B3 (G657 B3) MULTIMODE SINGLEMODE ORDERING FORM (to be copied, filled, scanned and sent with your purchase orders) PRETERMS P NUMBER OF FIBER TYPES OF PRETERMS LENGTH (M) END A END B PERFORMANCES Quantity x... MTP TM LINK (END A) MTP TYPES OF PRETERMS NUMBER OF FIBER LENGTH (M) END B (Only for FAN & FAN C) PERF. x... PATCHCORDS J TYPE OF END A END B LENGTH (M) PERFORMANCES PATCHCORDS x... Company name... Address... Contact person... Tel... Position... Email... 11
www.multimedia-connect.fr ED 08/2014