User Manual. PCKeypad Wireless Keypad

Similar documents
Waterproof. Keypad/Reader/Controller

CM-110SK Standalone Keypad Installation Instructions

W3-H Waterproof Keypad/Reader/Controller

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

W3-M. Metal waterproof standalone access control/reader. User Manual

BC Digital Keypad. User Manual

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Single Door Standalone Access Control User Manual

DOLXFD1000B. Waterproof Access Control/Reader

Fingerprint Access Control F1. User Manual

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

VIDI-AC-2CS Access Controller/ Reader

Stand-alone Proximity Access Control

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

RBR-SB-KTZ001 LAR 2. User Manual

-DTZ001- Stand-Alone Proximity Access Control. User Manual

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Installation and User Manual

EL-ST100 KEYPAD CONTROLLER

DG-800 Stand-Alone Proximity Reader Instruction Manual

PCR43304R, PCR43304RE 4-Channel, 433MHz Penta Receiver with Frequency Hopping

Digital Keypad Introduction

User Manual. Split access control with intelligent secured power supply.

Metal Standalone Keypad Access Control S100

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

PCR43304R, PCR43304RE 4-Channel, 433MHz Penta Receiver with Frequency Hopping

CC Series metal access control Manual

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

ACCESS CONTROL SYSTEM

Installing Keypad and Backplate

VIS-3200 / VIS-3201 User Manual

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

KP2000E/EM Series Style Keypad

ACTsmart2 Product Range Operating and Installation Instructions

PCR43301RE 1-Channel, 433MHz Penta Receiver with Frequency Hopping

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

CP150B Vandal & Weather Resistant Keypad Security Systems

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

PCR43301RE ELSEMA. . and anywhere else you need a wireless signal to transmit a contact closure. Description

GV-Card Reader. User s Manual

AS Keypad User Manual

PCR43302RE, PCR43302R 2-Channel, 433MHz Penta Receiver with Relay outputs

PCR R 2 Channel, 433MHz Penta Receiver with Frequency Hopping

Wireless Key fob, Key pad & Receiver Range

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

PCR R, PCR RE 2 Channel, 433MHz Penta Receiver with Frequency Hopping

RFID/Digital Access Control Keypad

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

HSY-S209 EM Metal waterproof access control system User Manual

FTK5 PROXIMITY KEYPAD

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

ACTentry A5 Kit. ACTentry A5 Entry Panel. Audio Door Entry with Access Control. Audio Door Entry & Access Control Kit Features

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions

GV-RK1352 and GV-R1352 Card Reader

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

2000 Series e/em Style Keypad Installation and Programming Manual

_ Access control SISTEMAS DE SEGURIDAD

1. Product Specification

180 Series Keypad. Handbook. Revision 2.1

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

Revision Date: 02 Mar 2018

SP1 MP1 WP2 WP1. 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes:

4 Channel DMX Driver Instruction Manual

MiR Bluetooth Box. Technical Documentation

K44 Code lock. Technical manual

INSTALLATION INSTRUCTIONS 923P EntryCheck TM

CV-945 Stand-Alone Biometric Reader. Installation Instructions

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL


Intelligent Security & Fire Ltd

Two Door Controller GEN-045

Wireless Digital Video Doorbell

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

THE BRIDGE. Make any Wiegand device wireless with the Sure-fi Bridge FEATURES. Technology

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

REX F-0-9 Standalone or Access Controller

605 D E C T G I n t e r c o m

Fingerprint Identification Proximity Reader. Quick Installation Guide

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

SK-1011-SQ Digital Access Keypad with 5A Relay Output

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Waterproof Exit Button x40x30/44mm - IP68, 304 Stainless Steel - Voltage: DC12V, DC9-24V (-W402N)

AC-015 Single-Door Access Control Programmer Hardware Installation and Programming Manual

ENFORCER SK-1131-SQ. Digital Access Keypad with 5A Relay Output MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

Specifications: Features:

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

7612 Programming Instructions

Installation Instructions

Transcription:

User Manual PCKeypad Wireless Keypad

Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option to use the classic 12-way dip switch coding or one of over 17 billion encrypted codes. (Please refer to the programming instructions) The PCKeypad is suitable for mounting either indoor or outdoor environments. It is housed in a strong vandal proof zinc alloy electroplated case. The PCKeypad conforms to Ingress Protection 65. The PCKeypad supports up to 2000 users with 4 to 8 digit PIN. These features make PCKeypad an ideal choice for gate and door access for homes, shops, factories, warehouses, laboratories, banks and prisons. Features Built-in PentaCODE transmitter Easy programming 12-24 VDC or 12-18 VAC Long operating range Strong zinc alloy electroplated anti-vandal case All programming is done from the keypad 2,000 users, PIN length 4 to 8 digits Adjustable transmission time Keypad has a backlight Built in light dependent resistor (LDR) for anti-tamper Built in buzzer Red, yellow and green LED display the working status

Installation Remove the back cover from the keypad using the supplied security screwdriver Code the transmitter to the receiver prior to mounting the Keypad Drill 4 holes on the wall for the screws and 1 hole for the cable Fix the back firmly on the wall with 4 flat head screws Thread the cable though the cable hole Attach the keypad to the back cover Specifications Operating Voltage 12 to 24 VDC or 12 to 18 VAC User Capacity 2,000 Active Current 92mA Idle Current 58mA Operating -5 C - +50 C Temperature Operating Humidity 10 % - 90% RH Adjustable 1-90 seconds Transmission Time Operating Range Up to 50 metres with line of sight Dimensions 128 x 82 X 28mm Weight 700g Wiring Wire Colour Red Black Green White Blue Function AC or DC Supply, + for DC AC or DC Supply, - for DC Wiegand 26 Bit Output D0 Wiegand 26 Bit Output D1 Wiegand Ground GND

Anti-Tamper Alarm The PCKeypad uses a built-in LDR (light dependent resistor) as an anti-tamper alarm. If the keypad is removed from the cover then the internal buzzer starts beeping for 1 minute. Reset to the Factory Default To reset the Keypad to the factory default follow the steps below: 1. Disconnect the power of the unit 2. Press and hold the * key 3. Reconnect power to the unit 4. Release the key after you hear 2 beeps The LED will turn amber for a few seconds and then change to flashing red with one beep. This indicates a successful reset. Programmed user ID and user PIN is retained even after factory reset. Transmission time The transmission time of the built-in PentaCODE transmitter is adjustable from 1 to 90 seconds. Factory default is 5 sec. See Programming Guide to change. Sound and Light Indication Operation Status Red Light Green Light Yellow Light Buzzer Power on Bright - - Short Ring Stand by Bright - - - Press keypad - - - Short Ring Operation successful - Bright - Short Ring Operation failed - - - 3 Short Ring Enter into programming - - Bright Short Ring mode In programming mode - - - Short Ring Exist from the Bright - - Short Ring programming mode Open the door - Bright - Short Ring

Alarm Bright Short Ring Programming Guide Enter Programming Mode (One beep, green light flashes once, red light On to confirm you are in programming mode.) Exist from the programming mode * Master code # 888888 is the factory default master code After 1min with no button pressed keypad will exit programming mode * Exit is confirmed with flashing red light. Note: The below changes can only be done while in programming mode. Change the master code (Orange light confirms you are in change mode) Add a user (Orange light confirms you are in adding mode. Green light flash indicates a user has been added.) Delete a user (Orange light confirms you are in delete mode. Green light flash indicates a user has been deleted.) Delete All users Warning : This option will delete all user s 0 New code # New code # The master code must be 6 digits long. 1 user ID number # PIN # ID number can be between 1-2000. The PIN is any 4-8 digits with the exception of 1234 which is reserved. Users can be added continuously without existing from programming mode as follows: 1 User ID No # PIN # User ID No 2 # PIN # Press # * to Exit. 2 User ID number # Users can be deleted continuously without existing programming mode. Press # * to Exit. 2 0000 # (Orange light confirms you are in delete mode. Green light flash indicates all users have been deleted.) Change transmission time 4 1 90 # Press * to Exit. Default is 5 sec (Orange light confirms you are in time change mode. Green light flash indicates that time has been changed.) Note: The below changes can only be done while out of programming mode. To activate the built-in PentaCODE transmitter Change a user s PIN (Red light ON confirms you are in User Change mode) PIN # (Green light comes ON for the transmission time.) * ID Number # Old PIN # New PIN # New PIN # (Green light comes ON when the pin has been changed.)

Sound and Light Settings Light and Sound Setting (Note: The below changes can only be done while in programming mode.) To set keypad backlight To set top light To set keypad tone 7 4 # To disable keypad backlight 7 5 # To enable keypad backlight (Factory default) Press * to Exit. 7 6 # To disable the red light 7 7 # To enable the red led light (Factory default) Press * to Exit. 7 8 # To disable the keypad tone 7 9 # To enable the keypad tone (Factory default) Press * to Exit. Keypad Lockout (Note: The below changes can only be done while in programming mode.) If there are 10 incorrect Pin entered in a 10 minute period, the keypad will go into a lock out mode for 120 minutes. This feature is disabled by factory default. Keypad Lockout 7 0 # To disable keypad lockout (Factory default) 7 1 # To enable keypad lockout Press * to Exit.

Programming to Penta Receiver The PCKeypad will work with all of Elsema s Penta series receivers. There are 2 methods of programming the Keypad to the receiver. 12- Way Dip Switch Coding 1. Remove the back cover of the keypad using the supplied screwdriver. 2. Match the 12-way dip switch to the receivers 12-way dip switch. (DO NOT USE THE DEFAULT FACTORY SETTING FOR THE 12-WAY DIP SWITCH AS THIS IS A COMMON CODE). 3. Test the keypad by typing in a valid user pin code. Encrypted Coding - (All 12-Way Dip Switches must be "Off") 1. Make sure that all 12-way dip switches are Off. 2. Type in a valid user code. ( the transmitter will transmit for 5 second (default)) 3. With-in the 5 second (or while the transmitter is transmitting) press the program 1 button on the receiver for 1 second.

Keep records of who is using the ID Numbers and Pins. This makes future additions and maintained easy. Keep this document in a secure and safe place. User ID Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Name of User Pin Use Microsoft Excel to create a longer list. 2000 User ID numbers can be added. Visit www.elsema.com to see our full range of Gate and Door Automation Products