FLP-PS DC Power Supply Model. Portable Sound System Mixer Amp/ Pre Amp/ Power Amp

Similar documents
OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

INFORMATION AMPLIFIER TA-102 OPERATING INSTRUCTIONS TABLE OF CONTENTS

T-60FP/T-120FP Mixer Amplifier

PUBLIC ADDRESS SYSTEM

TABLE OF CONTENTS 1. SAFETY PRECAUTIONS GENERAL DESCRIPTION FEATURES AND FUNCTIONS 4. CONNECTIONS 6. APPLICATIONS...

A120 A W/240W PA Mixer-Amplifier 70V/100V

OPERATION MANUAL ADS W rms Mixer Amplifier

4120A 4-CHANNEL AMPLIFIER PROTECT POWER CLIP TEMP SIGNAL CH 2 CH 1 OFF

FLP-MA-120U / MA-240U

OPERATING INSTRUCTIONS PA AMPLIFIER A-1706 A-1712 A-1724

4 ZONE AMPLIFIER MIXER MZ4120S OPERATION MANUAL

OPERATING INSTRUCTIONS

REMOTE CONTROLLER RESET HOLD GROUP

ZONE1 ZONE2 ZONE3 ZONE4 ZONE5 MODE BASS BASS BASS BASS BASS BASS MIC1 MIC2 MIC3 MIC4 LINE1 LINE2 TREBLE TREBLE TREBLE TREBLE TREBLE TREBLE

INTEGRATED VOICE EVACUATION SYSTEM VX-2000 series

TS-780 (CENTRAL UNIT) TS-781 (CHAIRMAN UNIT) TS-782 (DELEGATE UNIT)

IP INTERCOM SUBSTATION INTERFACE UNIT N-8010RS INSTALLATION MANUAL

A-2060D/ DD SERIES A-2120D/ DD/ DT SERIES A-2240D/ DD/ DT SERIES

User Manual MODEL: QM 450A

ETA-PD8A AC Power Conditioner & Distribution Unit

POWER AMPLIFIER OPERATING INSTRUCTIONS TABLE OFCONTENTS

SOUND REPEATER EV-20R

AL-MAGPIE Wireless Infrared Microphone

OPERATING INSTRUCTIONS

AP-S20 AC Power Distribution Unit & Surge Suppressor

Installation Manual. 65 Interactive LED/LCD. Model: HILF65101 (64.56 )

AP-S15HR AC Power Conditioner & Distribution Unit

C-CV24-2 NTSC INSTRUCTION MANUAL TABLE OF CONTENTS

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

OWNER S MANUAL GEQ 131/ 131LF GEQ 215/ 215LF GEQ 231. Single Channel 31 Band Graphic Equalizer. 2 Channel 15 Band Graphic Equalizer

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

TPC25 active crossover. user manual

AM1200 Soung Masking System

PNP415/417 POP 'N PLUG WITH CUSTOM TABLETOP SURFACE USER'S GUIDE

ETA-PD8 Power Conditioner & Distribution Unit

OPERATING INSTRUCTIONS

Amplified subwoofer - 12" - 400W RMS

Owner s Manual. F6-AMIX Multi-Function Analog Mixer Card Accessory Module for F6-MF. F6-AMIX Multi-Function Analog Mixer Card. AtlasSound.

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

DM25, DM40. Compact 100V mixer-amplifiers with Bluetooth. Item ref: UK, UK User Manual

INSTALLATION MANUAL. Infared Transmitter/ Receiver. Central unit. Bridge unit (1-Conference unit connection type)

PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS

NX-50 FEATURES. Powered Speaker OWNER S MANUAL

SWA watt Subwoofer Amplifier with DSP and Presets

TWISTED PAIR DISTRIBUTOR KE 0108CH-DW. Instruction Manual. Thank you for your purchase of this product

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Installation Manual. Model: HILU Ultra HD Interactive Flat Panel Display

PR3400 Series 1.4Mp USB Cameras Hardware Guide

DS-1H05 Ethernet-over-Coax Extender. User Manual

R Band Parametric Equalizer (6 Center Frequencies)

IMPORTANT SAFETY INSTRUCTIONS

APT20. User Manual.

TA18 active subwoofer. user manual

PS8 - II. Professional Power Sequencer. User s Manual

TA12 full-rangespeaker. user manual

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

Tabletop Paper Collator FC-10

R-503 Parametric Equalizer + 2 Shelf Baxandall (BAX) bands

MA100 full-range speaker. user manual

SUBWOOFER SYSTEM YST-MSW10

12X3W UV LEDS PROJECTOR LED- 12 USER GUIDE

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

Konica Minolta s industrial instruments. Safety Precautions

VMC-8114P VMC-8414P INSTRUCTION MANUAL. Colour Video Monitor

User Manual VIDEO DOOR PHONE

ISDN 8510T Voice Terminal Instructions for Changing the EPROM

Important Information KX-NTV150. Communication IP Camera. IP Video Doorphone. Model No. Model No. KX-NTV160

User s Guide. for Echo Express SEL 10GbE. 10 Gigabit Ethernet Thunderbolt 2 Adapter

HP4 headphone amplifier. user manual

DMX Splitter 4 MKIII 19" DMX splitter. user manual

D1210H dimmer pack. user manual

PRE116/126. User Manual.

User Manual DUO BEAM/RG

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

FUSION 400. User s Guide. 4-Bay Serial ATA Hot-Swap Drive Enclosure. For Windows

Pyrit 212 Sub A active subwoofer. user manual

FUTURE CALL. Future Call Model FC-1204 Totally Hands Free Voice Activated Dialing and Answering Telephone OWNER S MANUAL AND OPERATING INSTRUCTIONS

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

High Precision Quad Output DC Power Supply

aframe electrorganic percussion Quick Start Guide

PCM60A 100W MAX P.A. AMPLIFIER.

SB 115A active subwoofer. user manual

TABLE OF CONTENTS ADJUSTING YOUR LCD MONITOR

OWNER S INSTRUCTION MANUAL

Achat 110 MA active full-range speaker. user manual

User manual. BookDrive. Automatic Page-turning Scanner

Model HM-535 Power Supply Installation and Service Instructions

SPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE

B&W RearView Camera Installation & Operation

OWNER'S MANUAL. Model:PSV Amp SWITCHING DC POWER SUPPLY.

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

18" 600W self-powered subwoofer USER GUIDE

VENU-80A INSTRUCTION MANUAL. Portable PA Amplifier System PRODUCT REGISTRATION

Owner s Manual EA-300

MSR100 POWERED SPEAKER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciones ENGLISH FRANÇAIS DEUTSCH ESPAÑOL

CM E FUJITSU SEMICONDUCTOR CONTROLLER MANUAL F 2 MC-16L/16LX EMULATION POD MB HARDWARE MANUAL

INTELLIGENT SERVER. Model: BMS-LSV6E

REPLACEMENT OF BATTERY 5. POWER AND VOLUME IDENTIFICATION UHF PLL Non-Diversity receiver module 7

Transcription:

FLP-PS-9024 DC Power Supply Model The PS 9024 functions as a power supply unit that provides 24V DC to a maximum of 4A output voltage for PA system range of rack-mounted equipment. During power outage, this equipment also acts as a changeover unit to back up equipment with 24V DC inputs, providing an assurance of continuous and uninterrupted power supply even with unexpected events on hand. When deployed for PA system, the PS 9024 converts any AC power supply to a DC power output to any equipment with 24V DC input such as a volume controller. Each unit of PS 9024 occupies only 1U rack space. Product Features Back-up battery of 24V DC SLA LED interface to indicate status Short-circuit protection Overload protection Self-healing protection Over-voltage protection Portable Sound System Mixer Amp/ Pre Amp/ Power Amp Specifications Connectors Power Requirement Rating Output Voltage Dimension Weight Finish DC and AC power interface 220-240 VAC 50-60Hz, 24V DC 24V DC 484 X 154 X 88 mm 3 kg Black Paging Microphone & Zone selector Equipments with 24V DC inputs 12 VOLT 12 VOLT BATTERY BATTERY DC 24V SLA battery Rack mount equipment 27

TM TM PROFESSIONAL PUBLIC ADDRESS SYSTEM 24V DC POWER SUPPLY ON OFF AC MAIN BATTERY IN DC OUT FLP-PS9024 24V DC POWER SUPPLY FLP-PS9024 OPERATION MANUAL Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.

TABLE OF CONTENTS 1. SAFETY PRECAUTIONS...3 2. GENERAL DESCRIPTION...5 3. FEATURES...5 4. NOMENCLATURE AND FUNCTIONS 4.1 Front Panel...6 4.2 Rear Panel... 7 5. MACHINE OPERATION...8 6. APPLICATIONS...9 7.SPECIFICATIONS... 10 8.DIMENSIONAL DIAGRAM...11 2

1. SAFETY PRECAUTIONS Be sure to read the instructions in this section carefully before use. Make sure to observe the instructions in this manual as the conventions of safety symbols and messages regarded as very important precautions are included. We also recommend you keep this instruction manual handy for future reference. Safety Symbol and Message Conventions Safety symbols and messages described below are used in this manual to prevent bodily injury and property damage which could result from mishandling. Before operating your product, read this manual first and understand the safety symbols and messages so you are thoroughly aware of the potential safety Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury. Indicates a potentially hazardous situation which, if mishandled, could result in moderate or minor personal injury, and/or property damage. When Installing the Unit Do not expose the unit to rain or an environment where it may be splashed by water or other liquids, as doing so may result in fire or electric shock. Use the unit only with the voltage specified on the unit. Using a voltage higher than that which is specified may result in fire or electric shock. Do not cut, kink, otherwise damage nor modify the power supply cord. In addition, avoid using the power cord in close proximity to heaters, and never place heavy objects -- including the unit itself -- on the power cord, as doing so may result in fire or electric shock. Be sure to replace the unit's terminal cover after connection completion. Because high voltage is applied to the speaker terminals, never touch these terminals to avoid electric shock. Be sure to ground to the safety ground (earth) terminal to avoid electric shock. Never ground to a gas pipe as a catastrophic disaster may result. Avoid installing or mounting the unit in unstable locations, such as on a rickety table or a slanted surface. Doing so may result in the unit falling down, causing personal injury and/or property damage. When the Unit is in Use Should the following irregularity be found during use, immediately switch off the power, disconnect the power supply plug from the AC outlet and contact your nearest dealer. Make no further attempt to operate the unit in this condition as this may cause fire or electric shock. If you detect smoke or a strange smell coming from the unit. If water or any metallic object gets into the unit If the unit falls, or the unit case breaks If the power supply cord is damaged (exposure of the core, disconnection, etc.) If it is malfunctioning (no tone sounds.) To prevent a fire or electric shock, never open nor remove the unit case as there are high voltage components inside the unit. Refer all servicing to your nearest dealer. Do not place cups, bowls, or other containers of liquid or metallic objects on top of the unit. If they accidentally spill into the unit, this may cause a fire or electric shock. Do not insert nor drop metallic objects or flammable materials in the ventilation slots of the unit's cover, as this may result in fire or electric shock. 3

1. SAFETY PRECAUTIONS When Installing the Unit Never plug in nor remove the power supply plug with wet hands, as doing so may cause electric shock. When unplugging the power supply cord, be sure to grasp the power supply plug; never pull on the cord itself. Operating the unit with a damaged power supply cord may cause a fire or electric shock. When moving the unit, be sure to remove its power supply cord from the wall outlet. Moving the unit with the power cord connected to the outlet may cause damage to the power cord, resulting in fire or electric shock. When removing the power cord, be sure to hold its plug to pull. Do not block the ventilation slots in the unit's cover. Doing so may cause heat to build up inside the unit and result in fire. Avoid installing the unit in humid or dusty locations, in locations exposed to the direct sunlight, near the heaters, or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric shock. When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and/or property damage. In addition, the object itself may fall off and cause injury and/or damage. Make sure that the volume control is set to minimum position before power is switched on. Loud noise produced at high volume when power is switched on can impair hearing. Do not operate the unit for an extended period of time with the sound distorting. This is an indication of a malfunction, which in turn can cause heat to generate and result in a fire. Contact your dealer as to the cleaning. If dust is allowed to accumulate in the unit over a long period of time, a fire or damage to the unit may result. If dust accumulates on the power supply plug or in the wall AC outlet, a fire may result. Clean it periodically. In addition, insert the plug in the wall outlet securely. Switch off the power, and unplug the power supply plug from the AC outlet for safety purposes when cleaning or leaving the unit unused for 10 days or more. Doing otherwise may cause a fire or electric shock. An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in the electrical installation of the building. 4

2. GENERAL DESCRIPTION The FLP-PS9024 is 24V DC power supply because the main power supply failure power outage automatically switch to standby power. 3. FEATURES 1. AC 240 V / 24V DC power supply. 2. Indications includes AC MAIN, BATTERY IN, DC OUT. 5

TM 4. NOMENCLATURE AND FUNCTIONS 4.1 FRONT PANEL ON OFF AC MAIN BATTERY IN DC OUT FLP-PS9024 24V DC POWER SUPPLY 1 2 3 4 1. POWER SWITCH On top of the opening Power Press the end, power shut down 2. AC MAIN Power indicator 3. DC OUT 24V DC battery output 4. BATTERY IN 24V DC batterty input 6

USE ONLY WITHA 250W FUSE NOMENCLATURE AND FUCTIONS 4.2 REAR PANEL +BATT -BATT +24V -24V ~240V 50Hz T2AL 250V IN OUT 5 6 5. 24V DC POWER INTERFACE 6. ~240V 50Hz AC POWER INPUT 7

5. MACHINE OPERATION 1. In the machine's power switch in the ON position, 240VAC power supply to stop when automatically switch to 24VDC IN 24VDC OUT of the power supply. 2. In the machine's power switch in the ON position, 240VAC and electricity, the after the transformer 24VDC OUT 240VAC power supply. 3. 24VDC OUT with a short circuit (overload), selfhealing protection. 8

- + - + - + - + - + - + - + - + - + - + 6. APPLICATIONS REAR PANEL CONNECTIONS +BATT -BATT +24V -24V IN OUT CH 1 CH 2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 ~240V 50Hz T2AL 250V USE ONLY WITHA 250W FUSE DC SUPPLY 24V,1A + - MONITOR PANEL 9

7.SPECIFICATIONS MONITOR PANEL MODEL CONTROL INDICATORS POWER SUPPLY DIMENSIONS(mm) NET WEIGHT GROSS WEIGHT FLP-PS9024 Power Switch AC MAIN, BATTERY IN, DC OUT. 24V DC 484X206X44 2.1Kg 3Kg 10

ON OFF AC MAIN BATTERY IN DC OUT TM TM FLP-PS9024 24V DC POWER SUPPLY +BATT -BATT +24V -24V ~240V 50Hz T2AL 250V USE ONLY WITHA 250W FUSE 8. DIMENSIONAL DIAGRAM UNIT :mm 484 ON OFF AC MAIN BATTERY IN DC OUT FLP-PS9024 24V DC POWER SUPPLY 6 UNIT :mm Over100 44 44 50 436 IN OUT 42 222 206 Over 100 Over 100 11

TM VersionV0.3