Version V2.2.9 Release date 217-9-6 Copyright 217, Builder: 2.5.3.9, Time: 1:29:48 SM Vendor ID Device ID Vendor name Vendor text Vendor URL 31 / x136 - s: 1 54 / x1 x36 59 / x1fd - s: 1 253 / x x1 xfd ifm electnic gmbh www.ifm.com http://www.ifm.com/ifmgb/web/io-link-download.htm Communication IO-Link revision Bit rate Minimum cycle time SIO mode supported Features Block parametrization Data storage V1.1 COM2 5. ms Yes Yes Yes Device variant SM51 Magnetic-inductive flow meter, 5...9, G 2 Page 1
Pcess data (Pcess data input) Total bit length = 64 Bit offset Bit length Totalizer Quantity meter which continuously totals the volumetric flow since the last reset Float32T 32-1999 to 9999 1 l Flow Current flow 16 16 (931) Err 92 to 93 (OL) -9199 to 9199-93 to -92 (UL) (-931) Err.1 Temperature Current temperature 2 14 (112) Err 1 to 11 (OL) -399 to 999-5 to -4 (UL) (-52) Err.1 OUT2 Status depends on [OU2] BooleanT 1 (false) inactive (true) active OUT1 Status depends on [OU1] BooleanT (false) inactive (true) active Page 2
Page 3
Standard Command 2 wo (13) Restore Factory Settings (161) Reset [HI.F] and [LO.F] memory (162) Reset [LO.F] memory (163) Reset [HI.F] memory (164) Reset Totalizer (165) Reset [HI.T] and [LO.T] memory (166) Reset [LO.T] memory (167) Reset [HI.T] memory (176) Start simulation (177) Stop simulation (24) IO-Link 1.1 system test command 24, Event 8DFE appears (241) IO-Link 1.1 system test command 241, Event 8DFE disappears (242) IO-Link 1.1 system test command 242, Event 8DFF appears Page 4
Standard Command 2 wo (243) IO-Link 1.1 system test command 243, Event 8DFF disappears (255) Command without effect, for internal use only Device Locks 12 RecordT Data Storage Unlocked: Parameter are saved in IO-Link masters memory. Locked: Saving of parameters in the IO-Link master is not possible. [INFO] Concerning this parameter, IO-Link master and device have to be configured the same way. An activated DataStorage within the masters configuration, indicates the devices DataStorageLock to be 'Unlocked'. bitoffs 1 BooleanT 1 Bit (false) (false) Unlocked (true) Locked Local User Interface Unlocked: Parameter can be changed via the devices keys. Locked: Parameter changes via the devices keys are prevented bitoffs 3 BooleanT 1 Bit (false) (false) Unlocked (true) Locked Vendor of the vendor of the device. 16 max 19 ifm electnic gmbh Vendor Text Additional information of the devices vendor. 17 max 11 www.ifm.com Page 5
Pduct 18 max 6 SM51 Pduct ID 19 max 6 SM51 Pduct Text 2 max 29 Magnetic- inductive flow meter Serial Number 21 max 11 Hardware Version 22 max 2 Firmware Version 23 max 3 Application Specific Tag A freely defined text can be assigned. 24 max 16 Detailed Device Status 37 21 h SP1_FLOW Switch point 1 / Flow, [SP1] 7 must be greater than [rp1]. Please take into account the current [rp1] value. [SP1] will be refused if below [rp1] 18 1 to 9.1 rp1_flow Reset point 1 / Flow, [rp1] 71 must be smaller than [SP1]. Please take into account the current [SP1] value. [rp1] will be refused if above [SP1] 175 5 to 895.1 ImPS Pulse value 78 Float32T.1.1 to 9 1 l ImPR Pulse repetition active (= pulse output) or not active (= function preset meter) 79 (1) YES Page 6
ImPR Pulse repetition active (= pulse output) or not active (= function preset meter) 79 (1) YES (1) YES () no FEP Frequency output of the end point of the flow value 8 9 2 to 9.1 FrEP Frequency End Point. Frequency at the Flow End Point 81 1 1 to 1.1 khz OU1 Output configuration [OUT 1] 84 (3) Hno / Hysteresis fct normally open (3) Hno / Hysteresis fct normally open (4) Hnc / Hysteresis fct normally closed (5) Fno / Window fct normally open (6) Fnc / Window fct normally closed (9) ImP / Impulse output (12) dou / Diagnostic output (17) FRQ / Frequency output OU2 Output configuration [OUT 2] 85 (1) I / Analog signal 4 2 ma (1) I / Analog signal 4 2 ma Page 7
OU2 Output configuration [OUT 2] 85 (1) I / Analog signal 4 2 ma (2) U / Analog signal...1 V (3) Hno / Hysteresis fct normally open (4) Hnc / Hysteresis fct normally closed (5) Fno / Window fct normally open (6) Fnc / Window fct normally closed (12) dou / Diagnostic output (14) In.D / Digital input SP2_FLOW Switch point 2 / Flow, [SP2] 86 must be greater than [rp2]. Please take into account the current [rp2] value. [SP2] will be refused if below [rp2] 36 1 to 9.1 rp2_flow Reset point 2 / Flow, [rp2] 87 must be smaller than [SP2]. Please take into account the current [SP2] value. [rp2] will be refused if above [SP2] 355 5 to 895.1 SP2_TEMP Switch point 2 / Temperature, 88 [SP2] must be greater than [rp2]. Please take into account the current [rp2] value. [SP2] will be refused if below [rp2] 2-192 to 8.1 Page 8
rp2_temp Reset point 2 / Temperature, [rp2] must be smaller than [SP2]. Please take into account the current [SP2] value. [rp2] will be refused if above [SP2] 89 196-196 to 796.1 ASP2_FLOW Analogue start point 2 / Flow. [ASP2] must be smaller than [AEP2]. Please take into account the current [AEP2]. For info on the minimum hysteresis [AEP2]-[ASP2] please refer to the operating instructions 9 to 72.1 AEP2_FLOW Analogue end point 2 / Flow. 91 [AEP2] must be greater than [ASP2]. Please take into account the current [ASP2]. For info on the min hysteresis [AEP2]-[ASP2] please refer to the operating instructions 9 18 to 9.1 ASP2_TEMP Analogue start point 2 / 92 Temperature. [ASP2] must be smaller than [AEP2]. Please take into account the current [AEP2]. For info on the minimum hysteresis [AEP2]-[ASP2] please refer to the operating instructions -2-2 to 6.1 AEP2_TEMP Analogue end point 2 / 93 Temperature. [AEP2] must be greater than [ASP2]. Please take into account the current [ASP2]. For info on the min 8 to 8.1 Page 9
hysteresis [AEP2]-[ASP2] please refer to the operating instructions DIn2 Configuration of digital input (Pin 2) 94 (2) +EDG () HiGH (1) LoW (2) +EDG (3) -EDG rto Meter reset mode 99 RecordT [OFF] = Manual reset / [Time] = Time contlled reset bitoffs 15 BooleanT 1 Bit (true) OFF (false) Time (true) OFF Meter reset time: coarse adjustment bitoffs 8 3 Bit (1) hours (1) hours (2) days (4) weeks Meter reset time: fine adjustment. Allowed max values for [Time] are 23 hours or 6 days or 8 weeks bitoffs (1) 1 (1) 1 (2) 2 (3) 3 (4) 4 (5) 5 (6) 6 (7) 7 (8) 8 (9) 9 (1) 1 (11) 11 (12) 12 (13) 13 (14) 14 Page 1
rto Meter reset mode 99 RecordT (15) 15 (16) 16 (17) 17 (18) 18 (19) 19 (2) 2 (21) 21 (22) 22 (23) 23 FOU1 [OUT 1] behaviour in case of fault 11 (4) OFF (1) OU (2) On (4) OFF FOU2 [OUT 2] behaviour in case of fault 12 (4) OFF (1) OU (2) On (4) OFF dst Delay Startup 13 to 5.1 s P-n Output polarity for the switching outputs 14 () PnP () PnP (1) npn dap Damping of the measured signal 15 6 to 5.1 s Page 11
dis Display settings 16 RecordT Display On / OFF bitoffs 7 BooleanT 1 Bit (false) On (false) On (true) OFF Display orientation bitoffs 6 BooleanT 1 Bit (false) Not tated (false) Not tated (true) Rotated 18 Update rate bitoffs 6 Bit (2) d2 / medium (1) d1 / fast (2) d2 / medium (4) d3 / slow Uni Selection of the physical unit 17 () () (1) m³/h SELd Selection of measurement on the sensor display 18 RecordT Displayed measurement bitoffs 15 Bit (1) FLOW (1) FLOW (2) TEMP (4) TOTL SEL2 Selection of the measurand for the evaluation via [OUT 2] 11 (1) FLOW (1) FLOW (2) TEMP LFC Low flow cutoff 111 5 5 to 15.1 FP Totalizer counting rule 112 () -+ () -+ (1) + Fdir Preferred direction of flow 114 () + () + Page 12
Fdir Preferred direction of flow 114 () + (1) - HI.F Maximum memory value for flow 118 () (931) Err.1 92 to 93 (OL) -9199 to 9199-93 to -92 (UL) (-931) Err LO.F Minimum memory value for flow 119 () (931) Err.1 92 to 93 (OL) -9199 to 9199-93 to -92 (UL) (-931) Err HI.T Maximum memory value for temperature 12 () (112) Err.1 1 to 11 (OL) -399 to 999-5 to -4 (UL) (-52) Err LO.T Minimum memory value for temperature 121 () (112) Err.1 Page 13
LO.T Minimum memory value for temperature 121 () 1 to 11 (OL).1-399 to 999-5 to -4 (UL) (-52) Err EP.On Empty pipe detection On / Off 124 () OFF () OFF (1) On EP.SP Empty pipe detection switch point 126 75-5 to 15 1 % dep.e Delay of the empty pipe detection when the switch point [EP.SP] is underrun 127 to 3.1 s dep.f Delay of the empty pipe detection when the switch point [EP.SP] is exceeded 128 2 to 3.1 s S.FLW Simulation of flow 131 (18).1-92 to 92-93 to -921 (UL) 921 to 93 (OL) (931) Err (144) SENS S.TMP Simulation of temperature 132 (2).1-4 to 1-5 to -42 (UL) Page 14
S.TMP Simulation of temperature 132 (2) 12 to 11 (OL) (112) Err.1 S.Tim Simulation duration 133 (2) 3 min () 1 min (1) 2 min (2) 3 min (3) 4 min (4) 5 min (5) 1 min (6) 15 min (7) 2 min (8) 3 min (9) 45 min (1) 6 min S.On Simulation state 134 () OFF (1) On () OFF Loc [Loc] locks the local user interface to prevent unintentional changes, [Loc] is resettable at the device 138 (1) uloc () Loc (1) uloc TOTL_M Consumed quantity before the last reset 148 Float32T -1999 to 9999 1 l Page 15
EP.Pr Empty pipe detection pcess value 29-5 to 15 1 % Events Code Type 348 d / 77 1 h Short circuit Err Check installation 35856 d / 8C 1 h Pcess variable range over-run Warning Pcess data uncertain. [INFO] This Event will not be transmitted via IO-Link Event mechanism. It is only available by reading 37 (Detailed Device Status) or 545 (BitCoded_ActiveEvents) 35872 d / 8C 2 h Measurement range over-run Err Check application 35888 d / 8C 3 h Pcess variable range under-run Warning Pcess data uncertain. [INFO] This Event will not be transmitted via IO-Link Event mechanism. It is only available by reading 37 (Detailed Device Status) or 545 (BitCoded_ActiveEvents) 3633 d / 8C C1 h Measuring pipe not sufficiantly filled. Too low conductivity of medium. Warning Please check your application 3634 d / 8C C2 h Measurement data acquisition failure. Err Replace device 3635 d / 8C C3 h Display function failure Warning Replace device 3635 d / 8D FE h Test Event 1 Warning Event appears by setting index 2 to value 24, Event disappears by setting index 2 to value 241 36351 d / 8D FF h Test Event 2 Warning Event appears by setting index 2 to value 242, Event disappears by setting index 2 to value 243 Err types Err code 32768 d / 8 h 32785 d / 8 11 h 32786 d / 8 12 h 328 d / 8 2 h 3283 d / 8 23 h Device application err - no details not available not available Service temporarily not available denied Service has been refused by the device application and no detailed information of the incident is available occurs to a not existing index occurs to a not existing subindex Parameter is not accessible due to the current state of the device application Write access on a read-only parameter Page 16
Err types Err code 32816 d / 8 3 h 32819 d / 8 33 h 3282 d / 8 34 h 32821 d / 8 35 h 32822 d / 8 36 h 32832 d / 8 4 h 32833 d / 8 41 h 32898 d / 8 82 h Parameter value out of range Parameter length overrun Parameter length underrun Function not available Function temporarily unavailable Invalid parameter set Inconsistent parameter set Application not ready Written parameter value is outside its permitted value range Written parameter length is above its predefined length Written parameter length is below its predefined length Written command is not supported by the device application Written command is not available due to the current state of the device application Written single parameter collides with other actual parameter settings Parameter inconsistencies were found at the end of block parameter transfer, device plausibility check failed Read or write service is refused due to a temporarily unavailable application Page 17