WirelessHART Toxic & Combustible Gas Detector P/N: TCD50H1A

Similar documents
Model Ultima OPIR-5. Infrared Open Path Gas Detector HART Field Device Specification. Instruction Manual

MODEL IR5500 Infrared Open Path Gas Detector HART Field Device Specification

M30118 Rev. A IOM HART DD IOM. Instructions for copying HART DD files to 375/475 using Field Communicator Easy Upgrade Utility 3.5

HART USER GUIDE FOR GASSONIC OBSERVER-H ULTRASONIC GAS LEAK DETECTOR

Model IR4000M. HART Field Device Specification Multi-Point Monitor. Instruction Manual 07-08

Crowcon Technical Note

The following steps will allow you to install and quickly begin using DevCom:

The following steps will allow you to install and quickly begin using DevCom:

TORRIX-HART. Technical Documentation. The magnetostrictive level sensor with HART Protocol. Edition: Version: 5 Article no.

Report Title : IR-Display HART Field Device Specification

Rosemount 928 Wireless Gas Monitor

PrimaX IR. HART Specification

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

WSDA User Guide

Oldham OLCT 200 Revision 1

The following steps will allow you to install and quickly begin using DevCom2000:

AMS HART Pass-Through Reference Guide

Agenda. Charging the QRAE II

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

Draeger Polytron IR 334 Programmable Serial Interface Card Series 2

DS404. Software Installation and Operations Manual. Multi-Inlet Docking Station. (800) (734)

Installing LE History Record Reader program software.

AVR Micro Audio Video Recorder. Operating Instructions

Eagle 2 Data Logger Management Program Operator s Manual

Table of Contents. CRA-200 Analog Telephone Adapter 2 x Ethernet Port + 2 x VoIP Line. Quick Installation Guide. CRA-200 Quick Installation Guide

Intuition ReAct Content Manager PC Application

Firmware install with Windows XP

Smart Wireless THUM Adapter

Technical Bulletin, HT/HM HART Module

GX-6000 Data Logger Management Program Operator s Manual

Windows. Updating Camera Firmware. Get ready

TITAN S8. Portable Data Acquisition Logger. Product User Guide

Sentrol Cloud User s Guide Ver. 2.01

Dissolved Oxygen (DO) Transmitter SMARTPro HART Command Specification

IEC Wireless Interface Instruction Manual (for ROC800-Series and FloBoss 107)

Rosemount 2051 Wireless Pressure Transmitters

QUICK START. DevCom2000 User Manual

Cosasco Wireless Corrosion Monitoring System

RADI-CEM. User manual. MPB S.r.l. Via Giacomo Peroni 400/ Rome - Italy. Tel Fax

RST INSTRUMENTS LTD.

1 System Requirements

HART Density Gauge Datasheet

IR Link Software Quick Reference Guide:

Modbus Communications Board

TopWorx 4310 Wireless Position Monitor

Flo-Ware. Discovering. Model 260/268 Flo-Tote System Manual. Version 3.1. Instrument & Data Management System for Windows 95,98 & NT

User Manual MPPTracker

MODEL ATV 4/6 BATTERY POWERED DIGITAL VACUUM INSTRUMENT

Configuring the DX99 HART Node for HART Field Devices

STONELOCK NETWORK USER MANUAL Version

Procom PPC Software User s Manual

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A

Marsh -McBirney, Inc.

Modbus Communications Board

RM5 HD configuration software Operating Manual

Wireless Corrosion Monitoring System

FRS / HM800 Update for Allegro MX

Brooks Models MT3809G Metal Tube Variable Area Flowmeters HART Handheld DD Installation & Operation Manual

Release 14 June 2005 (Dent X Rev. 1 September 29, 2006)

NSGV Series "90DM3" Carbon Dioxide Detector

RY-IP44. Input/Output Network Adaptor. Programming Manual. For use with IX Series, IS-IP Series, and IPW-1A

HART Field Device Specification Fisher FIELDVUE DVC5000 Digital Valve Controllers

Webview Help Guide. OnSite Telemetry System. Distributed by: Chart Inc th Street NW New Prague, MN USA (800)

FREQUENTLY ASKED QUESTIONS

Waters Empower Software A1100 System Configuration Instructions for Ethernet Control

Upgrade Instructions. Note

CONTENTS I. DEVICE SETUP II. INSTALLATION III. UNINSTALL RETAIL MODE

RY-IP44. Input/Output Network Adaptor. Programming Manual. For use with IX Series, IS-IP Series, and IPW-1A

Envotech SLx 2 Update Basic Programming Tool Ver 1.9. User MANUAL

INDEX. Network Power Monitor R10 SNMP

Synergy Controller Application Note 20 April 2008, Revision P4 Tidal Engineering Corporation 2008

MODEL 320 HEATED NON-METHANE HYDROCARBON CUTTER OPERATING MANUAL

2 Product Overview. 5 User Interface. 14 Logging Data. 17 Viewing Data. 19 Managing Data. 24 Device Settings. 26 Specifications.

4-20 ma Current Data Logger

EXM Configuration Tool EXM System Configuration Instructions

Library ebooks and Your B&N Nook

SKF Wireless Machine Condition Sensor

Firmware install with Windows 7

FIELDVUE Digital Valve Controllers. Tri-Loop Signal Converter Operation with FIELDVUE Digital Valve Controllers

Alien Handheld RTU Guide Version 3.9

Rosemount 702 Wireless Discrete Transmitter

T E C H N O T E. Peer-to-Peer Communication with WirelessHART. HCF_LIT-129, Revision 1.0. Abstract:

Kurz Instruments, Inc. MFT B-Series

erequest How to apply guide

GX-2009 Data Logger Management Program Operator s Manual

N2KAnalyzer. User s Manual

SolarPower Pro. User s Manual. Management Software for Solar Inverter

DELTA CONTROLS CORPORATION

Quick Start Guide v1.0

Series 3000 User Manual and Product Features

Geo2005 Operating System New Features and Upgrade Instructions

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth.

FileMaker. Mobile 7. User s Guide. For Windows, Mac, Palm OS, and Pocket PC. Companion for Palm OS and Pocket PC

Product User Guide PR2000. PR2000 Pressure Data Logger with LCD

Model GX-2001 Data Logging Software. User s Guide

GX-2009 Data Logger Management Program Operator s Manual

DS400 / DS404. Software Installation and Operations Manual. DS400 Docking Station. (800) (734)

INSTRUCTIONS FOR UPDATING SOFTWARE ON THE i-stat PORTABLE CLINICAL ANALYZER

NotifyMDM Device Application User Guide Installation and Configuration for Android

PowerShield SNMP Adaptor

Transcription:

WirelessHART Toxic & Combustible Gas Detector P/N: TCD50H1A 475 Handheld Communicator Configuration Instructions

This page is intentionally left blank ii

United Electric Controls provides these handheld communicator configuration instructions for use with the UE Vanguard WirelessHART toxic & combustible gas detector solely. Consult the manual from the manufacturer of the handheld communicator for warnings and additional instructions for use. Instructions for operating the UE Vanguard WirelessHART toxic & combustible gas detector can be found at /vanguard United Electric Controls Co. 180 Dexter Avenue Watertown, MA 02472, USA Telephone: +1 617 926-1000 Fax: +1 617 926-2568 Email: TechSales@UEonline.com Web: www.ueonline.com iii

Table of Contents 1.0 General 1.1 Normal Operation Overview.......1 2.0 Device Description (DD) 2.1 DD Download..... 2 2.2 DD Download using Easy Upgrade Utility....2 2.3 DD Registration Note.... 7 2.4 DD Download using AMS System or HART Host System..... 7 3.0 Configuring Network Parameters 3.1 Network ID.....8 3.2 Join Key.....9 4.0 Configuring Gas Concentration....10 5.0 Configuring Burst Rate.........12 iv

1.0 GENERAL 1.1 Device Normal Operation Overview Under normal operation, the four variables (Table 1) are communicated via WirelessHART 7.2 communication protocol every 8 seconds by default, using burst message 0. The update rate is programmable from 1 second up to 3600 seconds*. Up to three burst messages (0-2) can be configured using the device description (DD). The burst message transmits a chosen HART command to publish data. HART commands that can be burst include: 1, 2, 3, 9, 33, and 48 (Table 2). The default configuration uses command 9. Device Variable Process Variable Units Accessibility Primary Variable (PV) Gas Concentration ppm or %LEL Read Secondary Variable (SV)** Temperature Degrees C Read Tertiary Variable (TV) Days Since Calibration Days Read Quaternary Variable (QV) Battery Voltage Volts Read Table 1 Command Description 1 Read Primary Variable 2 Read Loop Current and Percentage Range 3 Read Dynamic Variables and Loop Current 9 Read Device Variables with Status 33 Read Device Variables 48 Read Additional Device Status Table 2 *Recommended minimum is 8 seconds.. **Not available on Methane (CH4) sensor. 1

2.0 DEVICE DESCRIPTION (DD) 2.1 DD Download Download the latest Vanguard DD for the 475 Field Communicator at http:///vanguard/dd.html 2.2 DD Download using Easy Upgrade Utility If using an Emerson 475 Field Communicator, use the Field Communicator Easy Upgrade utility to facilitate the download of the UE Vanguard DD to the handheld. 1. Download the Vanguard DD to a computer per 2.1 DD Download and save the DD in an accessible location. 2. Launch the Field Communicator Easy Upgrade utility on the computer and click on Utilities on the left panel, shown on the screen below. 475 Field Communicator and Easy Upgrade are products of Emerson Process Management. 2

3. Click on Import DDs from a local source 4. On the pop up window, click Browse to select the folder containing the saved Vanguard DD for the 475 Field Communicator. 5. Select UNITED_ELECTRIC TCD50 Rev 1 DD 2 and click OK to proceed. 6. Return to the home interface by clicking on Upgrade on the left panel. 7. Select Connection Type before clicking Connect. Note: To connect by card reader, remove the SD card from the 475 Field Communicator and insert the SD card into the card reader attached to the computer. 3

8. Click on More Options, and then click on the DD tab. Expand the HART option by clicking on the + beside it. 4

9. Locate United Electric as shown below and check the option with TCD50 Rev 1 DD 2. 10. If the message Check an Untrusted Package appears, click YES. 11. Click on the >>> arrow button to transfer the TCD 50 DD onto the SD card. There will be acknowledgement to indicate when the download is complete. 5

12. Click Disconnect. 13. If using a card reader, reinstall the SD card back into the 475 Field Communicator. The handheld will now recognize the UE Vanguard. 6

2.3 DD HART Registration Note HART Registration of Vanguard DD is pending. When achieved, the DD can be downloaded at www.fieldcommgroup.org. Since the current Vanguard DD is not registered, the following may come up when the Vanguard is connected to the handheld communicator. This is a standard warning for any unregistered DD and should not effect Vanguard operation or data reporting. Press the CONT button to proceed with set-up. 2.4 DD Download using AMS System or HART Host System 1. Copy the DD files into the following /HCF directory on your machine: /HCF/DDL/LIBRARY/006049/XXXX Note: Where XXXX is the device type code, this would be E308 for the Vanguard TCD50. 2. The AMS program should recognize and load the DD for the transmitter with a connected device. 7

3.0 Configuring Network Parameters The Vanguard device has to be programmed in order to join the WirelessHART network. 2 parameters have to be inputted, namely the Network ID and the Join Key. The Network ID is, the Join Key. 3.1 Network ID 1. Scroll down and select Setup on the Field Communicator. Press the right arrow to proceed. 3. Select Network ID. Press the right arrow to input Network ID. 4. Input Network ID and tap ENTER. 2. Select Wireless Setup. Press the right arrow to proceed. 5. Network ID is saved into the Vanguard.. 8

3.2 Join Key 4. Select Join Key 1 of 4. Press the right arrow to input segment 1 of the Join Key. 1. Scroll down and select Setup on the Field Communicator. Press the right arrow to proceed. 5. Input the 8 character Join Key and tap ENTER. 2. Select Wireless Setup. Press the right arrow to proceed. 6. Repeat steps 4 and 5 for the rest of the segments for the Join Key. 7. Tap SEND to save Join Key into the Vanguard. 3. Ensure correct Network ID is displayed on the Field Communicator screen.. 9

4.0 Configuring Gas Concentration The Vanguard device has a default gas concentration setting of 50 (ppm or LEL). The setting is adjustable in value from 25 to 50 (integer value only). Note: This setting has to match the calibration gas concentration for accurate calibration. Changing the Gas Concentration Calibration Value 1. Scroll down and select Setup on the Field Communicator. Press the right arrow to proceed. 3. Select option 1 to set gas concentration for calibration. Press the right arrow 4. Input desired value and tap ENTER. 2. Select Gas Concentration Setup. Press the right arrow to proceed. 5. Desired gas concentration value is saved into the Vanguard device.. 10

Gas Concentration Configuration Changing the Gas Concentration Units of Measurement 1. Scroll down and select Setup on the Field Communicator. Press the right arrow to proceed. 3. Select option 2 to set units of measurement for calibration gas concentration. Press the right arrow to proceed. 2. Select Gas Concentration Setup. Press the right arrow to proceed. 4. Select desired unit and tap ENTER. 5. Desired units of measurement is saved into the Vanguard device. 11

5.0 Configuring Burst Rate Burst mode is a communication mode in Vanguard that sends data at regular intervals and from Vanguard to the host. The default burst rate is 8 seconds. If you accept the default settings from the factory, Command 9 will transmit ppm or %LEL concentration, ambient temperature, time since last calibration, and battery voltage data. 1. Scroll down and select Setup on the Field Communicator. Press the right arrow to proceed. 3. Select Burst Setup and press the right arrow to proceed. 2. Select Burst Mode Setup and press the right arrow to proceed. 4. Select Message 0 and tap ENTER to proceed. 12

9. Tap OK to proceed. 5. Input the desired burst update time (e.g. 32s seconds). The factory default is 8 seconds. This update is adjustable between 1* and 3600 seconds. 10. Select Finished and tap ENTER. 6. Tap ENTER to proceed. 7. Input the desired burst maximum update time only if using the Burst Trigger function. Otherwise, input desired burst update time from Step 5 above. 11. Select No and tap ENTER. Desired burst rate will be saved into the Vanguard device. 8. Tap ENTER to proceed. *Recommended minimum is 8 seconds. 13