SonoSelect and SonoSafe energy meters

Similar documents
SonoSelect 10 and SonoSafe 10 energy meters

SONOMETER TM 500 Ultrasonic compact energy meter

SonoMeter 30 Ultrasonic energy meter for heating and cooling applications

All it takes to measure, collect and analyze energy consumption in heating and cooling applications

EW773 Series Ultrasonic Hydronic Meters FOR HEATING AND COOLING APPLICATIONS

2 CLASS AMR READY INVONIC H DATA APPLICATION HEAT METERING. approved ULTRASOUND HEAT AND COOLING METERS DN15, DN20, DN25, DN40, DN50

SonoMeter 30 Ultrasonic energy meter for heating and cooling applications

User guide. SonoMeter 30. Ultrasonic energy meter for heating and cooling applications. Danfoss VUIGI102 1

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773

EW773 Series Ultrasonic Hydronic Meters DN FOR HEATING AND COOLING APPLICATIONS

SITRANS F flowmeters SITRANS F US. SITRANS FUE950 energy calculator. 4/240 Siemens FI

Static Heat Meter ULTRAHEAT XS 2WR6... UH f. Configuration and composition

EW500 Series Energy Calculators FOR HEATING AND CHILLED WATER ENERGY METERING

AB Axis Industries. Use

FAUN PROFESSIONAL, NEW GENERATION INDICATING CALCULATOR FOR SEPARABLE HEAT METERS

THE TOP CALCULATION/ELECTRONIC UNIT MUST NOT BE SEPARATED FROM THE BOTTOM BRASS BODY.

Entering a Whole New Dimension The ULTRAHEAT XS Heat Meter

PolluTherm. Integrator for measuring heating and cooling energy. Main characteristics. Available design.

Installation Guide DEVIlink CC Central Controller

Immersion Temperature Sensors

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

SITRANS F US Inline. SITRANS FUE950 energy calculator 4/269

DEVIwet 230V room thermostats for hydronic floor heating

EW170 Series Woltman Bulk Water Meters DN FOR COLD AND WARM POTABLE WATER APPLICATIONS

Temperature sensors and accessories for heat and cooling measurement points

EC 600 Electronic Volume Corrector

Flow Measurement SITRANS F US Inline

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

A 101 A B C. Variable flow-control valve, series DXC. Dynamic Flow Networking. Description. Content

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

living connect, Z-Wave Certified Electronic Radiator

living connect and Danfoss Link CC wireless thermostat system. Total temperature control from one central point.

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

living connect and Danfoss Link CC wireless thermostat system. Total temperature control from one central point.

Protocol interface AK-PI 300

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe

Level sensor Stainless steel version Model RLT-1000, for industrial applications

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

MCX08M2 Programmable controller

Installation Guide Solid State Meter

CI-tronic Reversing contactor Type RCI

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

AEW36.2. Pulse Adapter. Siemeca AMR

B 201 A B C. dynamx variable flow-control valves, series DXMB_C. Dynamic Flow Networking. Description. Content

Pressure control valves type B

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

MID approval no. DE-08-MI004-PTB004 Date of release

UPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps

Absolute Encoders Multiturn

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

Actuators for modulating & 3-point control

Ultrasonic Flow Meter Brochure

HEAT METER CALCULATOR QALCOMET HEAT 1

GRUNDFOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers. For conductivity measurement (conductive, inductive)

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Protocol interface AK-PI 200 REFRIGERATION AND AIR CONDITIONING. Manual

Chart recorder. DS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Modulating controlled actuator AME 11

Metering systems 0670EN February 2014 Volumetric thermal energy meters for use in a boiler room GE552-1 series

RoHS. High shaft load capacity. Shock / vibration resistant

Flow VA 500/

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

ULTRASONIC HEAT METER IFX-M4-04

SITRANS F M MAG 8000 SITRANS F. Answers for industry. Precise metering with battery powered water meters.

Thermal Mass Flowmeter Sensyflow FMT200-D

M-Bus Modules. Data sheet. for MULTICAL 403

Room controller STRA-17

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

ENERGY METER AND DATA MANAGEMENT

Designed for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections.

Temperature measurement TER8 Front-flush and low-invasive resistance thermometers

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_

IDS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

T550 (UC50 ) 1. General. 3. Installation. 2. Safety Information Translation. en Installation Instructions

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo

WATER TELEMETRY SYSTEM

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Variable Area Flowmeter DATASHEET

HERZ STRÖMAX GM/GML/GR STRÖMAX-GM/GML Circuit Control Valve with test points STRÖMAX-GR Circuit Control Valve Data sheet STRÖMAX GM/GML/GR, Issue 0215

WARNING ELECTRICAL SHOCK HAZARD

ENVIRONMENTAL MONITORING & CONTROL

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

PADPULS2 M-BUS Pulse Input Modules

RA-N Radiator Valves with Integrated Presetting

AEW36.2. Pulse Adapter. Building Technologies. Siemeca AMR

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

RESIDENTIAL WATER METERS GSD5 1/2" AF GSD5 3/4" AF ,00 GSD8 1/2" AF GSD8 3/4" AC

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

ENCODER. Profibus Multiturn. Series , Key-Features:

Flow measurement FlexFlow PF20S Flow sensor for industrial applications

DP DP2500 DP0250

Transcription:

SonoSelect and SonoSafe energy meters Description The Danfoss SonoSelect and SonoSafe are ultrasonic compact energy meters intended for measuring energy consumption in heating applications for billing purposes. The meters are designed for remote meter read-out (AMR). The energy meters consist of an ultrasonic flow sensor, a pair of PT1000 temperature sensors and a calculator with integrated circuits for temperature measurement, flow calculation and energy calculation. Feature highlights: Proven ultrasonic measuring principle designed for long operating life time No calming section or inlet/outlet restrictions Low pressure drop down to 0.03 bar at qp Large 85 x 35 mm LCD display with 8 digits (11.5 mm high), guiding menu and info panel Compact design Extensive change and error log Memory: 2 years of data, monthly values for latest 24 months (pulse input also stored) Upgradable with communication modules Battery is replacable Communication baud rate 300, 2400, 4800 and 9600 bps SonoApp usable for Android (Bluetooth LE via dongle) Special features: SonoSelect SonoSafe Battery 16 + 1 years battery life 10 + 1 years battery life Flexibility Safe SonoApp Supply and return can be configured on site Energy units can be configured on site Slot for communication upgrade 1.5 m cable PUR between calculator and flow sensor allow for flexible installation, e.g. in flat stations EN1434 class 2 + flow and energy calculated every 0.5 second Tamper monitor sets alarm if meter is opened by unauthorized personnel Diagnostic function to secure confidence in meter data IP65 calculator Reverse flow indication Installer tool (Guides and configure e.g. AMR, Pulse, units, supply/return) Commissioning tool (Link location to serial number) Operation tool (data read out and display function + diagnostic) Slot for communication upgrade 0.5 m cable PVC between calculator and flow sensor EN1434 class 2 + flow and energy calculated every 2 seconds IP54 calculator Operation tool (data read out and display function) VDIGH302 Danfoss FHH 2016.02 1

Ordering SonoSelect Meter size DN15 q p 0.6 G¾A 110 mm DN15 q p 0.6 G¾A 110 mm Communication Energy unit Installation Code no. kwh Return 014U0068 kwh Supply 014U0069 DN15 q p 0.6 G¾A 110 mm Wired M-Bus module with 2x pulse inputs kwh Return 014U0072 DN15 q p 0.6 G¾A 110 mm Wired M-Bus module with 2x pulse inputs kwh Supply 014U0073 DN15 q p 1.5 G¾A 110 mm DN15 q p 1.5 G¾A 110 mm kwh Return 014U0081 kwh Supply 014U0082 DN15 q p 1.5 G¾A 110 mm Wired M-Bus module with 2x pulse inputs kwh Return 014U0085 DN15 q p 1.5 G¾A 110 mm Wired M-Bus module with 2x pulse inputs kwh Supply 014U0086 DN20 q p 1.5 G1A 130 mm 1) Radio with 2 x pulse kwh Return 014U0094 DN20 q p 1.5 G1A 130 mm 1) Radio with 2 x pulse kwh Supply 014U0095 DN20 q p 1.5 G1A 130 mm 1) Wired M-Bus module with 2x pulse inputs kwh Return 014U0098 DN20 q p 1.5 G1A 130 mm 1) Wired M-Bus module with 2x pulse inputs kwh Supply 014U0099 DN20 q p 2.5 G1A 130 mm DN20 q p 2.5 G1A 130 mm kwh Return 014U0107 kwh Supply 014U0108 DN20 q p 2.5 G1A 130 mm Wired M-Bus module with 2x pulse inputs kwh Return 014U0111 DN20 q p 2.5 G1A 130 mm Wired M-Bus module with 2x pulse inputs kwh Supply 014U0112 DN25 q p 3.5 G1¼A 160 mm 2) DN25 q p 3.5 G1¼A 160 mm 2) kwh Return 014U0120 kwh Supply 014U0121 DN25 q p 3.5 G1¼A 160 mm 2) Wired M-Bus module with 2x pulse inputs kwh Return 014U0124 DN25 q p 3.5 G1¼A 160 mm 2) Wired M-Bus module with 2x pulse inputs kwh Supply 014U0125 DN25 q p 3.5 G1¼A 260 mm DN25 q p 3.5 G1¼A 260 mm kwh Return 014U0133 kwh Supply 014U0134 DN25 q p 3.5 G1¼A 260 mm Wired M-Bus module with 2x pulse inputs kwh Return 014U0137 DN25 q p 3.5 G1¼A 260 mm Wired M-Bus module with 2x pulse inputs kwh Supply 014U0138 DN15 q p 0.6 G¾A 110 mm With integrated M-BUS kwh Return 014U0165 DN15 q p 0.6 G¾A 110 mm With integrated M-BUS kwh Supply 014U0166 DN15 q p 1.5 G¾A 110 mm With integrated M-BUS kwh Return 014U0167 DN15 q p 1.5 G¾A 110 mm With integrated M-BUS kwh Supply 014U0168 DN20 q p 1.5 G1A 130 mm 1) With integrated M-BUS kwh Return 014U0169 DN20 q p 1.5 G1A 130 mm 1) With integrated M-BUS kwh Supply 014U0170 DN20 q p 2.5 G1A 130 mm With integrated M-BUS kwh Return 014U0171 DN20 q p 2.5 G1A 130 mm With integrated M-BUS kwh Supply 014U0172 DN25 q p 3.5 G1¼A 160 mm 2) With integrated M-BUS kwh Return 014U0173 DN25 q p 3.5 G1¼A 160 mm 2) With integrated M-BUS kwh Supply 014U0174 1) Add extension pipe 014U1957 to comply with EN1434/CJ 128-2007 length of 190 mm. 2) Add extension pipe 014U1958 to comply with EN1434 length of 260 mm. 2 Danfoss FHH 2016.02 VDIGH302

Ordering SonoSafe Meter size Communication Energy unit Installation Code no. DN15 q p 0.6 G¾A 110 mm None kwh Return 014U0001 DN15 q p 0.6 G¾A 110 mm None kwh Supply 014U0002 DN15 q p 0.6 G¾A 110 mm With integrated M-BUS kwh Return 014U0003 DN15 q p 0.6 G¾A 110 mm With integrated M-BUS kwh Supply 014U0004 DN15 q p 1.5 G¾A 110 mm None kwh Return 014U0005 DN15 q p 1.5 G¾A 110 mm None kwh Supply 014U0006 DN15 q p 1.5 G¾A 110 mm With integrated M-BUS kwh Return 014U0007 DN15 q p 1.5 G¾A 110 mm With integrated M-BUS kwh Supply 014U0008 DN20 q p 1.5 G1A 130 mm 1) None kwh Return 014U0009 DN20 q p 1.5 G1A 130 mm 1) None kwh Supply 014U0010 DN20 q p 1.5 G1A 130 mm 1) With integrated M-BUS kwh Return 014U0011 DN20 q p 1.5 G1A 130 mm 1) With integrated M-BUS kwh Supply 014U0012 DN20 q p 2.5 G1A 130 mm None kwh Return 014U0013 DN20 q p 2.5 G1A 130 mm None kwh Supply 014U0014 DN20 q p 2.5 G1A 130 mm With integrated M-BUS kwh Return 014U0015 DN20 q p 2.5 G1A 130 mm With integrated M-BUS kwh Supply 014U0016 DN25 q p 3.5 G1¼A 160 mm 2) None kwh Return 014U0017 DN25 q p 3.5 G1¼A 160 mm 2) None kwh Supply 014U0018 DN25 q p 3.5 G1¼A 160 mm 2) With integrated M-BUS kwh Return 014U0019 DN25 q p 3.5 G1¼A 160 mm 2) With integrated M-BUS kwh Supply 014U0020 DN25 q p 3.5 G1¼A 260 mm None kwh Return 014U0021 DN25 q p 3.5 G1¼A 260 mm None kwh Supply 014U0022 DN25 q p 3.5 G1¼A 260 mm With integrated M-BUS kwh Return 014U0023 DN25 q p 3.5 G1¼A 260 mm With integrated M-BUS kwh Supply 014U0024 1) Add extension pipe 014U1957 to comply with EN1434/CJ 128-2007 length of 190 mm. 2) Add extension pipe 014U1958 to comply with EN1434 length of 260 mm. VDIGH302 Danfoss Danfoss FHH 2016.02 3

Accessories Product Designation Quantity Code no. Tail piece set DN15 R½ x G¾ 1 set 087G6071 Tail piece set DN20 R¾ x G1 1 set 087G6072 Tail piece set DN25 R1 x G1¼ 1 set 087G6073 Adaptor for temperature sensor R½ x M10 x 1 1 pc. 087G6075 Adaptor for temperature sensor R½ x M10 x 1 32 pcs. 087G6076 Ball valve G½ internal thread, PT sensor connection M10 1 pc. 187F0593 Ball valve G½ internal thread, PT sensor connection M10 12 pcs. 087H0118 Ball valve G½ internal thread, PT sensor connection M10 1 pc. 187F0592 Ball valve G½ internal thread, PT sensor connection M10 12 pcs. 087H0119 Ball valve G½ internal thread, PT sensor connection M10 1 pc. 187F0591 Ball valve G½ internal thread, PT sensor connection M10 12 pcs. 087H0120 Extension pipe, L = 60 mm DN20 x G1 1 pc. 014U1957 Extension pipe, L = 100 mm DN25 x G1¼ 1 pc. 014U1958 Gasket DN15 1 set 014U1964 Gasket DN20 1 set 014U1965 Gasket DN25 1 set 014U1966 O-ring mounting kit O-ring Ø4.3 x 2.4 + assembly tool 1 set 014U1967 Battery Battery pack 1 AA cell 1 pc. 014U1968 Battery Battery pack 2 AA cell 1 pc. 014U1969 Communication module M-Bus module 1) 1 pc. 014U1998 Communication module 2) 1 pc. 014U1999 Communication module RS-485 Modbus with 1 Pulse input 3) 1 pc. 014U1996 Communication module RS-485 Modbus with 2 Pulse Output 3) 1 pc. 014U1997 Bluetooth dongle IR2BLE 1 pc. 014U1963 Sealing kit 4 x wire with + 4 x snap lock seal 1 set 014U1962 1) Wired M-Bus to EN13757-3. Baud rate of 300, 2400, 4800 and 9600 supported. The two pulse inputs can be programmed independently of each other. 2) Wireless M-Bus 868,95 MHz OMS to EN13757-4. T1 and T2 mode supported. The two pulse inputs can be programmed independently of each other. 3) Wired RS-485 Baud rate of 300, 2400, 4800 and 9600 supporting Modbus and M-bus protocol. 2 Pulse output or 1 Pulse input can be independently programmed 4 Danfoss FHH 2016.02 VDIGH302

Technical specifications, Complete energy meter Application Heating Medium Water quality with ph 7 to 9.5 VDI 2035, VdTÜV TCh 1466 Approvals Measuring cycle EN1434 class 2, MID (DK-0200-MI004-034), CPA according to JJG225-2010 Flow: 0.5 sec. (SonoSelect), 2 sec. (SonoSafe) Energy: 0.5 sec. (SonoSelect), 2 sec. (SonoSafe) Temperature: 4 sec. (SonoSelect), 10 sec. (SonoSafe) Approved meteorological range ΔΘ: 3-90K Θ: 5-95 C Temperature limits (accounting) ΔΘ: 0.25-100K Θ: 0-105 C IP Cable strain relief Ambient operating temperature Ambient storage temperature Temperature media 65 (SonoSelect), 54 (SonoSafe) Withstand more than 5 kg Class A: 5-55 C -25-60 C 5-95 C Humidity <95% Vibration EMC Class M2 Class E1 Weight DN15: 700 g DN20: 800 g DN25: 1100 g (160 mm) Technical specifications, Calculator Battery Battery life time* Display Units Memory Optical interface Communication Additional communication 3.6 V DC lithium battery (1 or 2 AA-cells depending on lifetime) 16+1 years (SonoSelect), 10+1 years (SonoSafe) 85 x 35 mm LCD display with 8 digits (11.5 mm high main characters). Menu guide and info panel. MWh - kwh - GJ - Gcal - C - K - m 3 - m 3 /h - l/h 2 years of data, monthly values for latest 12 months (pulse input also stored) Optical acc. to EN61107. Data protocol acc. to EN13757-3, supports 2400 or 4800 baud. Wired M-bus to EN13757-3, supports 300, 2400, 4800, 9600 baud. Delivered with 1 m cable (SonoSelect: PUR, SonoSafe: PVC) 1 slot for communication module (delivered from factory or later upgrade) * Battery life time measured under following preconditions: enclosure temp. 45 C, communication every 15 min. Technical specifications, Temperature sensor Type Size Nipple Cable length Accuracy Temperature range Approved temperature range to EN60751 Difference temperature EN60751 Pressure PT1000 direct short, 2 wire Diameter: Ø5.2 mm, length: 26 mm M10 x 1 mm brass, with pin lock 1.5 m Class B (EN60751) Θ: 0-105 C (SonoSelect), 5-95 C (SonoSafe) Θ: 0-105 C ΔΘ: 3-105K 25 bar VDIGH302 Danfoss Danfoss FHH 2016.02 5

Technical specifications, Flow sensor DN 15 15 20 20 25 25 Nominal flow qp [m 3 /h] 0.6 1.5 1.5 2.5 3.5 3.5 Max flow qs [m 3 /h] 1.2 3 3 5 7 7 Minimum flow (1:100) qi* [m 3 /h] 0.006 0.015 0.015 0.025 0.035 0.035 Cut off flow qc [m 3 /h] 0.0012 0.003 0.003 0.005 0.007 0.007 Overflow qss [m 3 /h] 1.26 3.15 3.15 5.25 7.35 7.35 * (1:250) qi on request DN 15 15 20 20 25 25 Connection G¾A 110 mm G1A 130 mm Pressure PN [bar] 16 G1¼A 160 mm G1¼A 260 mm Pressure drop (at qp 50 C) [mbar] 30 150 150 160 130 135 IP [EN60529] 65 Temperature limits [ C] 0 to 105 Cable length Mounting 1.5 m (SonoSelect: PUR), 0.5 m (SonoSafe: PVC) Any position, no inlet or outlet restrictions Application drawings Supply Return 6 Danfoss FHH 2016.02 VDIGH302

Accuracy Error [%] Flow sensor error Flow sensor error 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0-0.5-1.0-1.5-2.0-2.5-3.0-3.5-4.0-4.5-5.0-5.5 0 10 20 30 40 50 60 70 80 90 100 Flow rate [%] Error [%] [%] 4.0 Temperature sensor difference error 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0-0.5-1.0-1.5-2.0-2.5-3.0 Error [%] -3.5-4.0 0 10 20 30 40 50 60 70 80 90 100 Temperature difference [K] 2.0 Calculator error 1.5 1.0 0.5 Error [%] 0.0-0.5-1.0-1.5 Error [%] -2.0 0 10 20 30 40 50 60 70 80 90 100 Temperature difference [K] In accordance with EN1434. VDIGH302 Danfoss Danfoss FHH 2016.02 7

Pressure loss 1000 q p 0.6 q p 1.5 q p 2.5 q p 3.5 Pressure loss [mbar] Pressure loss [mbar] 100 10 100 1 000 10 000 100 000 Flow rate [l/h] Menu structure Display of f 120 sec. Accumulated Alarm Energy Volume Hours click LOOP 1 2 sec. Current Power Flow Supply temp. Return temp. Display test/all on 2 sec. click LOOP 2 History log 5 sec. click Accounting date Monthly date 1 >> Monthly date 12 LOOP 3 Mounting Rotation in pipe axis. Pipe position: No limitations, but avoid position where air can be collected. 8 Danfoss FHH 2016.02 VDIGH302

Dimensions Ø2 A D E max. 37.4 F B C 133 89 Dimension DN15 DN20 DN20 + extension pipe 014U1957 DN25 DN25 + extension pipe 014U1958 A G¾A G1A G1A G1¼ A G1¼ A B 12 14 14 16 16 C 110 mm 130 mm 190 mm 160 mm 260 mm D 33.5 mm 38 mm 38 mm 40.5 mm 40.5 mm E 74.5 mm 77.5 mm 77.5 mm 80.5 mm 80.5 mm F = AF 32 mm 32 mm 32 mm 41 mm 41 mm Weight 700 g 800 g 1100 g 1100 g 1600 g VDIGH302 Danfoss Danfoss FHH 2016.02 9

Danfoss A/S Energy Meters Ulvehavevej 61 DK-7100 Vejle Denmark Phone: +45 7488 8500 Fax: +45 7488 8501 heating@danfoss.com www.heating.danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 10 Danfoss Danfoss FHH 2016.02 VDIGH302