POL635.XX/XXX POL636.XX/XXX POL638.XX/XXX POL638.70/XXX

Similar documents
CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

Climatix TM Climatix Controller. For controlling, switching and monitoring functions

Communication module to connect M-bus devices to POL6xx.xxx controllers.

Climatix programmable controller

Climatix range. Climatix TM

HVAC&R controller. Climatix C600. POL648.x0, POL688.x0, POL69x.x0

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Resistance measuring module

Super universal modules

Power supply module, bus connection module

Web interface BACnet/IP

MCX08M2 Programmable controller

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Digital input modules

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

Extension module for lighting control

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

TXM1.8RB. TX-I/O Blinds module

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Island bus expansion module

Room unit with PPS2 interface

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Climatix Sales Presentation. Kurt Steiner / xxx-x-xxx

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

BACnet/IP Web Interface

IMIO100 IMIO105. DDC controllers. Summary

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Room automation station

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Universal Controller

Immersion Temperature Sensors

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Room unit with PPS2 interface

Room unit with PPS2 interface

Programmable controller MCX152V

Evo2. Free programmable room controller. Summary

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Compact universal controllers

General information. Display. Supply voltage. Input current. Encoder supply. Output current

MCX06C Programmable controller

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Programmable controller MCX06C

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

mark150s mark150/485s DDC controllers Summary

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

em4 Accessories Digital expansions

AIAS. Technical description

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

General information. Display. Supply voltage. Input current. Encoder supply. Output current

APP 700 Technical Specification

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

IntesisBox Modbus Server Panasonic

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current

Electromotoric actuators

General information. Display. Supply voltage. Input current

TF501, TF521 Terminal Bases

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Programmable controller Type MCX06C

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Logic Controller Millenium Evo

AI531 Analog Input Module

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Logic Controller Millenium Evo

General information. Display. Supply voltage. Input current

ABB i-bus KNX BCI/S Boiler/Chiller Interface

ABB i-bus KNX HCC/S Heating/cooling circuit controller

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Transcription:

s 3 230 Climatix TM Climatix Controllers For controlling, switching and monitoring functions POL635.XX/XXX POL636.XX/XXX POL638.XX/XXX POL638.70/XXX The controllers are products of the Climatix range. Also refer to Data Sheet 3900 and Mounting Instructions M3910 The POL63X controllers are designed for use in connection with compact air heating units or in ventilation, air conditioning and refrigeration plants. Controller types POL635.xx/xxx Basic version SD card, modem, battery holder POL636.xx/xxx Basic version and LON interface POL638.70/xxx Basic version with HMI and TCP / IP interface POL638.xx/xxx Basic version and TCP / IP interface CB1Q3230en_03 06.05.2010 Building Technologies

The controllers offer the following features: Freely programmable Object-oriented programming by graphic editor SAPRO Expandability via peripheral bus for local or remonte I/O extension modules Power supply AC 24 V or DC 24 V 8 universal I/Os (configurable inputs / outputs, for analog or digital signals) DC 24 V onboard power supply for active sensors 5 digital inputs (potential-free contacts) 2 analog outputs (DC 0 10 V outputs) 6 relay outputs (NO contacts) RS-485 in Modbus RTU model for third-party bus Full modem RS-232 port for remote service Process bus for connecting room units and remote HMI (DPSU) Up to 3 additional communication modules for BACS integration Local service connector for user interface (RJ45) and PC tools (USB) SD card for application and operating system upgrade LON field bus (POL636.00 only) Ethernet port for remote or local servicing using standard browsers (POL638.00 only) Operating temperature -20 60 C (without LCD -40 70 C) Communication concept 2 / 16

Overview Note Connection terminals and plugs The LON interface is installed on POL636.XX/XXX only. The Ethernet interface is installed on POL638.XX/XXX only. Power supply 4 relays outputs 2 relays outputs 8 universal inputs / outputs Process bus (KNX) RS-485 (Modbus RTU) 2 analog outputs Tool (USB) Ethernet (POL638.00 only) 5 digital inputs HMI (RS-485) LON interface (POL636.00 only) 3 / 16

Power supply 0 V, AC/DC 24 V (T1) Operating voltage AC 24 V ±20%; DC 24 V ±10% Frequency 45 65 Hz Max. AC current without extension modules 1.8 A @ 24 VAC Max. DC current without extension modules 1.0 A @ 24 VDC Max. current for extension modules 2,2 A @ 24 VAC / 3.0 A @ 24 VDC Max. external supply line fusing 10 A slow wire fuse or circuit breaker Safety transformer Mains Connecting power supply Relay outputs Q1...Q6 (T6, T7) Relay: Type, contact Monostable, NO contact Contact rating Switching voltage AC 24 230 V (-20%, +10%) Nominal current (res. / ind.) Max. AC 4 A / 3 A (cosφ 0.6) Switching current at AC 19 V Min. AC 30 ma Max. external supply line fusing 6.3 A slow wire fuse or circuit breaker Warning Do not mix (SELV / PELV) and line voltage on the same terminal Use external protection for inductive loads AC 24 V supply voltage Connecting control lamps to relay output 4 / 16

Universal I/Os X1,X2 only input X3 X8 universal (T2) Configurable Reference potential Contact voltage Overvoltage protection By software Terminals Max. DC 24 V (SELV) Up to 40 V Analog inputs (X1 X8) LG-Ni1000 Sensor current Resolution Accuracy within the range of -50 150 C Pt1000 Sensor current Resolution Accuracy within the range of -40 120 C NTC 10k 1.4 ma 0.1 K 0.5 K 1.8 ma 0.1 K 0.5 K Sensor current 140 μa Temperature range Accuracy Resolution -50-26 C 1 K 0.2 K NTC 100k -25 74 C 0.5 K 0.1 K 75 99 C 1 K 0.3 K 100 124 C 3 K 1.0 K 125 150 C 6 K 2.5 K Sensor current 140 μa Temperature range Accuracy Resolution -25-11 C 3 K 0.2 K -10 9 C 1 K 0.1 K 10 99 C 0.5 K 0.1 K 100...150 C 1 K 0.2 K 0...2,500 Ω Sensor current Resolution Accuracy 1.8 ma 1 Ω 4 Ω Ratiometric sensor Connecting a ratiometric sensor to universal I/O 5 / 16

DC 0...10 V input Resolution Accuracy at 0 V Accuracy at 5 V Accuracy at 10 V Input resistance DC 0/4 20 ma input Resolution Accuracy at 4 ma Accuracy at 12 ma Accuracy at 20 ma 1 mv 10 mv 25 mv 50 mv 100 kω 1 μa 40 μa 70 μa 120 μa Voltage source 0...10 V Current transmitter 0 20 ma Voltage input DC 0...10 V and Current input 0/4...20 ma Digital inputs (X1 X8) 0/1 digital signal (binary) For potential-free contacts Sampling voltage / current DC 24 V / 8 ma Contact resistance Max. 200 Ω (closed) Min. 50 kω (open) Delay 10 ms Pulse frequency Regulated by cycle time of the Controllertask fmax = 20 HZ for Tcycl. max <= 25 ms fmax = 1 / (2 + Tcycl. max) for Tcycl. max > 25 ms Connecting floating contacts to universal I/O 6 / 16

Analog outputs (X3 X8) DC 0 10 V output Resolution Accuracy at 0 V Accuracy at 5 V Accuracy at 10 V Output current 11 mv 66 mv 95 mv 124 mv 1 ma (short-circuit-proof) Connecting voltage output and current output to universal I/O Digital outputs (X5 X8) DC output for off board loads Switching voltage Switching capacity DC 24 V Max. 25 ma Connecting external relay to universal I/O 7 / 16

Powering sensors; active / ratiometric 2 x 2 outputs +24 V Voltage / current Reference potential Connection DC 24 V +10%, -25% / 2 x 40 ma Terminals Short-circuit-proof Pressure transmitter Connecting a sensor with AC 24 V supply voltage Digital inputs D1 D5 (T4) 0/1 digital signal (binary) For potential-free contacts Sampling voltage / current DC 24 V / 8 ma Contact resistance Max. 200 Ω (closed) Min. 50 kω (open) Delay 10 ms Pulse frequency Max. 30 Hz Connecting floating contact to digital input 8 / 16

Analog outputs Y1, Y2 (T3) DC 0 10 V output Resolution Accuracy at 0 V Accuracy at 5 V Accuracy at 10 V Output current 11 mv 66 mv 95 mv 124 mv 2 ma (short-circuit-proof) Connecting voltage outputs 0 10 V Interfaces Process bus CE+, CE- (T8) Process bus Bus connection 2-wire twisted pair Bus connection / electronics Bus load Bus cable Bus cable length between 2 KNX nodes Total length of bus KNX cable Bus power supply via Based on KNX TP1 (refer to KNX Manual) CE+, CE-, not interchangeable Galvanically isolated Max. 5 ma Must be shielded; refer to KNX Manual System Specifications Max. length is 700 m Max. length of KNX cable is 1000 m Internal DPSU with 50 ma nominal current External standard KNX power pack Connecting the process bus 9 / 16

MODBUS (RS-485 RTU) A+, B-, REF RS-485 (EIA 485) Bus connection / electronics Bus connection 2-wire twisted pair Bus termination (switched via software) Modbus RTU mode 2-wire twisted pair, shielded Not galvanic isolated A+, B-, REF 680 Ω / 120 Ω +1 nf / 680 Ω Connecting a MODBUS Local service tool interface T-SV USB device interface Cable connection Standard cable Socket type B USB receptacle, series B Length of cable <3 m Connecting a USB interface Local HMI interface T-Hi HMI (RS-485) Cable connection Cable (< 3 m) HMI-Communication HMI-Speisung RJ45 jack, 8 pins For tools use USB-Cable POL0C2 HMI cable is with POL895.51 enclosed RS485 24 V max. 100 ma LEDs LEDs for diagnostics 3 colors (green, yellow and red) BSP Run/Stop LED Mode Update mode (download active or a new BSP, application) Application not loaded Application loaded but not running Application running BSP error (software error) Hardware error LED status Every second alternating between red and green Yellow blinking: 50 ms on and 1000 ms off Yellow on Green on Red blinking at 2 Hz Red on 10 / 16

Bus LED This LED only indicates the status of the integrated modem communication. It does not indicate the status of the internal communication (to I/O or COM extension modules). This status is visible on the respective extension modules. Mode No modem connected, or LED disabled Modem connected and initialized no communication active Modem connected and communication active Modem connected but errors active (like provider missing, no initialization possible) LED status Off Yellow on Green on Red on Modem service interface Connection via plug at top right of the controller Tool and modem (full modem interface) Cable connection Supported modem types RJ45 jack, 8 pins, at top right length of cable <3 m Siemens TC65 GSM modem terminal Devolo Microlink 56k I SD card Connection via plug at top right of the controller SD card (SDHC) Slot 128 MB 2GB Data-system FAT16, FAT32 Switching on and off during read-and-write access can lead to loss of data. Warning LON interface CLA, CLB- Note Plug-in terminals Galvanically isolated 2 wires, interchangeable 2-wires, twisted pair, shielded The LON interface is installed on POL636.00/XXX only. 11 / 16

Ethernet IP service interface TCP-IP Communication Cable connection 10/100 Mbit (IEEE 802.3U) RJ45 jack, 8 pins Connecting TCP/IP Ethernet TCP/IP example Note The Ethernet interface is installed on POL638.00/XXX only. 12 / 16

Peripheral bus COM extension communication modules Connection via plug on the bottom left side of the controller. Based on SPI interface for the communication module connection. Low-voltage power supply for com module Number of COM module Voltage / current Board-to-board connector (not included) Max. 3 (self-acting module detection) DC 5 V ±10% / max. 1 A Short-circuit-proof ZEC1,0/10-LPV-3,5 GY35AUC2CI1 I/O extension I/O modules Connection via plug at bottom right of the controller. Based on RS-485 interface for the I/O module connection. Power supply in the controller Ueff = AC 24 V ± 20%, fmain = 45...65 Hz or U = DC 24 V ± 10%, no internal fuse Bus termination selectable (680 Ω / 120 Ω +1 nf / 680 Ω ) Connector (not included) Solid wire Stranded wire (twisted or with ferrule) Cable lengths Board-to-board: ZEC 1,0/4-LPV-3,5 C1 Board-to-wire: ZEC 1,0/4-ST-3,5 C1R1 0.2 1.0 mm² 0.2 1.0 mm² Max. 30 m or 13 / 16

Technical data Real-time clock Buffering with internal gold cap Buffering with additional battery Min. 3 days Min. 200 days Inbuilt HMI LCD with white backlight Navigation 144 x 64 dots Roll-and-push knob 3 function buttons Environmental conditions Operation IEC 721-3-3 Temperature Restriction HMI Restriction process bus Restriction with 1 com module Restriction with 2 com modules Humidity Atmospheric pressure -40...70 C -20 60 C -25 70 C -40 65 C -40 60 C <90% r.h. (non-condensing) Min. 700 hpa, corresponding to max. 3,000 m above sea level Transport IEC 721-3-2 Temperature -40...70 C Humidity <95% r.h. (non-condensing) Atmospheric pressure Min. 260 hpa, corresponding to max. 10,000 m above sea level Protection Degree of protection Safety class IP20 to EN 60529 with RJ45 jack at top right IP10 to EN 60529 without RJ45 jack at top right Suitable for use in safety class II plant Standards General data Product safety Automatic electrical controls EN 60730-1 Electromagnetic compatibility Suitable for residential and industrial EMC environment Immunity EN 60730-1 +A16 Emissions EN 60730-1 +A16 CE conformity EMC directive 2004/108/EEC Low-voltage directive 2006/95/EEC C-tick conformity In accordance with AU EMC framework Radio Communications Act 1992 AS/NZS CISPR11 UL approvals UL916, UL873 Signal equipment certified for Canada CSA C22.2M205 RoHs compliance 2002/95/EC (Europe) ACPEIP (China) Dimensions of controller Weight excl. packaging Controller without HMI Controller with HMI 180 x 110 x 75 mm 487 g 422 g Base Plastic, pigeon-blue RAL 5014 Housing Plastic, light-grey RAL 7035 14 / 16

Order data Basic controller ACX35 EVO Basic controller ACX36 EVO with LON interface Basic controller ACX38 EVO with TCP/IP interface Basic controller ACX38 EVO with TCP/IP interface and HMI Connector set screw type (not included) POL635.00/XXX POL636.00/XXX POL638.00/XXX POL638.70/XXX POL063.85/STD Plug set The necessary plug set (connector set) is not included with the controller Example FKCT 1 positions (Phoenix MVSTBW, FKCCW or FKCT 2,5/2-ST) Orange 3 positions (Phoenix MVSTBW, FKCCW or FKCT 2,5/2-ST) Grey 2 positions (Phoenix MVSTBW, FKCCW or FKCT 2,5/3-ST) Grey 1 positions (Phoenix MVSTBW, FKCCW or FKCT 2,5/4-ST) Grey 2 positions (Phoenix MVSTBW, FKCCW or FKCT 2,5/6-ST) Grey 2 positions (Phoenix MVSTBW, FKCCW or FKCT 2,5/8-ST) Grey Connection terminals For I/O signals For communication For power supply Solid wire Stranded wire (twisted or with ferrule) Cable lengths Plug-in terminals: Screw / clamp Color: Gray Grid: 5 mm Plug-in terminals: Screw / clamp color: Gray Grid: 5 mm Plug-in-terminals: Screw / clamp Color: Orange Grid: 5 mm 0.5 2.5 mm² 0.5 1.5 mm² In compliance with the load, local regulations and installation documents Engineering notes Warning To ensure protection against accidental contact with relay connections at voltages above 42 V eff, the device must be installed in an enclosure (preferably a control panel). It must be impossible to open the enclosure without the aid of a key or tool. AC 230 V cables must be double-insulated against safety extra low-voltage (SELV) cables. Disposal notes The controller contains electrical and electronic components and must not be disposed of together with household waste. Local and currently valid legislation must be observed! 15 / 16

Dimensions Dimensions in mm POL63X.00/XXX 16 / 16 2009 Siemens Switzerland Ltd. Subject to change