Unidrive M400 (Frame 1 to 4) Quick Start Guide

Similar documents
Unidrive M200, M201 (Frame 1 to 4) Quick Start Guide

Unidrive M Quick Start Guide. Frame sizes 1 to 4. Value drive with quality and performance for open loop applications

Quick Start Guide. Unidrive M200/201. Frame sizes 5 to 6. Flexible machine integration through communications. Part Number: Issue: 6

Quick Start Guide. Unidrive M200/201. Frame sizes 1 to 4. Flexible machine integration through communications. Part Number: Issue: 5

Quick Start Guide. Unidrive M300. Frame sizes 1 to 4. Enhance throughput with Machine Safety. Part Number: Issue: 5

Unidrive M Quick Start Guide. Frame sizes 1 to 4. Value drive with quality and performance for open loop applications

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

Quick Start Guide Cutler-Hammer SVX9000 Drives from Eaton Corporation CONTENT STEP 1 Keypad Operation Overview STEP 2 Standard Wiring Diagrams and

Firmware Manual - EC Series Drives

Unidrive M400. Control Quick Start Guide

AF-60 LP TM Micro Drive. Programming Guide

EQ5 SERIES Quick Start Guide for Constant Torque Applications

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Installation & Operating Instructions

Quick Start Guide. Unidrive M200/201. Frame sizes 1 to 4. Flexible machine integration through communications. Part Number: Issue: 6

GV3000/SE 230 VAC 1-20 HP General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.04

COMBIMASTER 411 & MICROMASTER 411

GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, HP, 230V AC

Optidrive Applications Support Library

Control Quick Start Guide. Unidrive M300. Enhance throughput with machine safety. Part Number: Issue: 2

AF-600 FP TM Fan & Pump Drive. (230V to 60HP, 460/575V to 125HP Operating Instructions

QUICK REFERENCE GUIDE

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

890 Quickstart Manual

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

Quick Start Guide For GVX9000 AF Drives

Power Connections: Basic Wiring:

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

Control Quick Start Guide. Unidrive M200/201. Flexible machine integration through communications. Part Number: Issue: 2

890 Quickstart Manual

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVLF

User Guide Regenerative & Non-Regenerative Digital DC Drives 5 to 1000 HP

AC Variable Speed Drive

1. Introduction About the Vacon 5X drive Identifying the drive by model number Drive model numbers...7

User Guide. IP20 & IP66 (NEMA 4X) AC Variable Speed Drive. Installation and Operating Instructions. 1 Quick Start Up kW (0.

Product Overview. PowerFlex 520-Series AC Drives Feature. Modular Design. Packaging and Mounting. Optimized Performance

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

IM-pAC. Getting Started Guide. AC variable speed drive for 3 phase induction motors from 0.25kW to 4kW, 0.33hp to 5hp. Model sizes A, B and C

LiquiFlo AC General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.4

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

QD:CT Plus & QD:VT Installation and Operating Instructions

LS M100 Frequency Inverter Easy Start Guide

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

Quick Start Guide RSi S Series VFD. Using the 7-segment (4 digit LED) Keypad/Display

IM-pAC. Getting Started Guide. AC variable speed drive for 3 phase induction motors from 0.25kW to 4kW, 0.33hp to 5hp. Model sizes A, B and C

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

vacon se2 user's manual

Control Quick Start Guide. Unidrive M200/201. Flexible machine integration through communications. Part Number: Issue: 3

ATV32H055N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

Commander SK. Getting Started Guide. AC variable speed drive for 3 phase induction motors from 0.25kW to 7.5kW, 0.33hp to 10hp

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

Commander SK. Getting Started Guide. AC variable speed drive for 3 phase induction motors. Model sizes 2 to 6. Part Number: Issue: 8

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

Limits and Methods of measurement of radio disturbance characteristics of industrial, scientific and medical (ISM) radio-frequency equipment (EMC)

Mitsubishi D700-SC Frequency Inverter. Easy Start Guide. The Mitsubishi D700-SC Frequency Inverter range is available to order from inverterdrive.

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

Drive Electronics \ Drive Automation \ System integration \ Services MOVITRAC LTE-B. Catalog. Edition 02/ / EN

ATV32H018M2 variable speed drive ATV32-0,18 kw V - 1 phase - with heat sink

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

Commander SK. EF Getting Started Guide

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

Instruc on Manual. Series S3. Industrial Inverter IP20 IP66

User guide. SRC Pumpdrive with SmartRun functionality, dedicated for waste water pump station

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

Commander SK. Getting Started Guide. AC variable speed drive for 3 phase induction motors from 0.25kW to 7.5kW, 0.33hp to 10hp

User Guide. IP20 & IP66 (NEMA 4X) AC Variable Speed Drive kW V

VS1ST AC Microdrive. 8/08 Installation & Operating Manual MN767

Control User Guide. Unidrive M100/101. Variable Speed AC drive for induction motors. Part Number: Issue: 3

VS mini J7 to J1000 Replacement Instructions

Getting Started Guide. Unidrive M700 Unidrive M701. Part Number: Issue: 5.

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Installation & Operating Instructions

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 2.00

ATV32HU40N4 variable speed drive ATV32-4 kw V - 3 phase - with heat sink

TECO L510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

IP20 Easy Start Up Guide

18805 Adams Ct., #110 ~ Morgan Hill, CA 95037, USA ~ ~ ~

Basic Drive Programming PowerFlex 755 Basic Start Up

IP55 Quick Start Up Guide

UNIDRIVE M200. Manufacturing Automation drives. Flexible machine integration through communications

Installation and Commissioning Instructions AC drive VersiDrive i... /E

ACS Product Overview

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Metasys N2 Instruction Manual VLT Adjustable Frequency Drive. 12/ Revision B

SENSORLESS VECTOR CONTROL

SED2 Variable Frequency Drives

Operating instructions. Speed monitor D / / 2014

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

Getting Started Guide. Unidrive M700 Unidrive M701. Model sizes 3 to 10. Part Number: Issue: 7.

Transcription:

This guide is intended to provide basic information required in order to set-up a drive to run a motor. For more detailed installation information, please refer to the Unidrive M400 User Guide which is available to download from www.controltechniques.com/userguides or www.leroy-somer.com/manuals. Safety information WARNING 2 Product information 2. Ratings Model Unidrive M400 (Frame to 4) Quick Start Guide This guide does not include safety information. Incorrect installation or operation of the drive, could cause personnel injury or equipment damage. For essential safety information, please refer to the Unidrive M400 User Guide or the safety booklet supplied with the drive. Input phases Max. cont input current Max input fuse rating Nominal cable size European USA Ph 3 Ph Input Output Input Output Max. cont output current Output current Nominal power Motor power ph A A A mm 2 mm 2 AWG AWG A kw hp 00007 8.7 0 6 6.7 0.25 0.33 000024. 6 4 6 2.4 0.37 0.5 020007 4.5 6 6 6.7 0.25 0.33 0200024 5.3 6 6 6 2.4 0.37 0.5 0200033 8.3 0 6 6 3.3 0.55 0.75 0200042 0.4 6 6 6 4.2 0.75 0200042 8.8 20 2.5 2 6 4.2 0.75 0200056 24 25 4 0 6 5.6..5 02200024 / 3 5.3/4. 6 6 6 6 2.4 0.37 0.5 02200033 / 3 8.3/6.7 0 0 6 6 3.3 0.55 0.75 02200042 / 3 0.4/7.5 6 0 6 6 4.2 0.75 02200056 / 3 4.9/.3 20 5 2.5/.5 2/4 6 5.6..5 02200075 / 3 8./3.5 20 5 2.5 2 6 7.5.5 2 0240003 3 2.4 6 6 6.3 0.37 0.5 0240008 3 2.9 6 6 6.8 0.55 0.75 02400023 3 3.5 6 6 6 2.3 0.75 02400032 3 5. 6 6 6 3.2..5 0240004 3 6.2 0 6 6 4..5 2 0320000 / 3 23.9/7.7 25 20 4.5 0/2 4 0 2.2 3 03400056 3 8.7 0 4 6 5.6 2.2 3 03400073 3 2.2 6.5 2 6 7.3 3 3 03400094 3 4.8 6 2.5.5 2 4 9.4 4 5 0420033 / 3 23.7/6.9 25 20 4/2.5 2.5 0 2 3.3 3 3 0420076 3 2.3 25 4 2.5 0 2 7.6 4 5 0440035 3 6.3 20 2.5 2.5 0 2 3.5 5.5 7.5 0440070 3 20.7 25 4 2.5 0 2 7 7.5 0 Unidrive M400 Quick Start Guide

NOTE Figure 2- The nominal cable sizes shown in the table above, are provided as a guide only. Ensure that the cables used conform to the local wiring regulations. Model number structure Derivative Electrical Specifications M400-03 4 00073 A Product line: Frame size: Voltage rating: - 00 V (00-20 ± 0 %) 2-200 V (200-240 ± 0 %) 4-400 V (380-480 ± 0 %) 5-575 V (500-575 ± 0 %) 6-690 V (500-690 ± 0 %) Drive Format : A AC inac out Current Rating : Heavy Duty current rating x0 3 Mechanical installation The drives can be panel mounted with 0 mm space between the drives. For further information on mechanical installation refer to the Unidrive M400 User Guide. A B A M2 Cover release H M B W M2 To remove the terminal cover, use a flat bladed screwdriver to rotate the terminal cover locating clip by approximately 30 in a counter clockwise direction, and then slide the cover down. Drive H W D M M2 A B Size mm in mm in mm in mm in mm in mm in mm in mm in 60 6.30 75 2.95 30 5.2 43 5.70 53 2.08 5 0.2 2 205 8.07 78 3.07 50 5.9 94 7.63 55 2.7 5 0.2 3 226 8.90 90 3.54 60 6.30 25 8.46 70.7 2.80 5 0.2 0.00 0.00 00 3.93 4 277 0.9 5 4.53 75 6.89 265 0.43 86 3.40 6 0.23 2 Unidrive M400 Quick Start Guide

Table 3- Table 3-2 Tools required Tool Location Size Size 2 Size 3 Size 4 Small terminal screwdriver Control, relay and STO terminals 3mm Flat-bladed screwdriver Power terminals 5mm Flat-bladed screwdriver Terminal cover Pozidrive screwdriver AC power terminals Pozidrive 2 screwdriver Power terminals Torx 0 driver EMC & MOV screws Torx 5 driver Fan screw Torx 20 driver Fan screw Recommended torque settings Terminal block Model size Torque settings description Control terminals 0.2 N m (0.5 Ib ft) All Relay terminals 0.5 N m (0.37 Ib ft) 0.5 N m (0.37 Ib ft) Power terminals 2, 3, 4.4 N m (.03 Ib ft) 4 Feature diagram (size 2 shown) 2 5 7 0 9 4 3 3 6 8 Key. Rating label (On side of drive) 2. Identification label 3. Option module connection 4. Relay connections 5. Control connections 6. Braking terminal 7. Internal EMC filter screw 8. DC bus + 9. DC bus - 0. Motor connections. AC supply connections 2. Ground connections 3. SAFE TORQUE OFF connections 2 Unidrive M400 Quick Start Guide 3

5 Electrical installation An overlay of the electrical connections / terminals is included on the back page of this manual. 6 Keypad and display The keypad and display provide information to the user regarding the operating status of the drive and trip codes, and provide the means for changing parameters, stopping and starting the drive, and the ability to perform a drive reset. Figure 6- Unidrive M400 keypad detail 5 2 3 4 () The Enter button is used to enter parameter view or edit mode, or to accept a parameter edit. (2) The Navigation keys can be used to select individual parameters or to edit parameter values. In keypad mode, the Up and Down keys are also used to increase or decrease the motor speed. (3) The Start key is used to start the drive in keypad mode. (4) The Stop / Reset key is used to stop and reset the drive in keypad mode. It can also be used to reset the drive in terminal mode. (5) The Escape key is used to exit from the parameter edit / view mode or disregard a parameter edit. NOTE The keypad is not supplied with the drive. 4 Unidrive M400 Quick Start Guide

7 Running the motor This section takes a new user through all the essential steps to running a motor for the first time. Section 4 provides the minimum connections required to connect and run a motor. Action Before power up Power up the drive Detail Ensure: The drive enable signal is not given, terminal 3 and 34 is open The run signal is not given, terminal 2/3 is open The motor is connected to the drive The motor connection is correct for the drive Δ or Y The correct supply voltage is connected to the drive Verify that the correct user drive mode is displayed as the drive powers up. If the mode is incorrect, Set Pr 00.079 to the correct mode, then press the stop/reset button to save the parameters. Ensure: The drive displays: Inhibit Enter minimum and maximum speeds Enter: Minimum speed Pr 00.00 (Hz) Maximum speed Pr 00.002 (Hz) Pr 02 Pr 0 t Enter accel and decel rates Enter: Acceleration rate Pr 00.003 (s/00 Hz) Deceleration rate Pr 00.004 (s/00 Hz) 00Hz Pr 03 Pr 04 t Enter motor nameplate details Enter: Motor rated current in Pr 00.006 (A) Motor rated speed in Pr 00.007 (rpm) Motor rated voltage in Pr 00.008 (V) Motor rated power factor in Pr 00.009 If the motor is not a standard 50/60 Hz motor, set Pr 00.039 accordingly Mot X XXXXXXXXX No XXXXXXXXXX kg IP55 I.cl F C 40 s S V Hz min - kw cosφ A 230 50 445 2.20 0.80 8.50 400 4.90 CN = 4.5Nm 240 50 445 2.20 0.76 8.50 45 4.90 CN = 4.4Nm CTP- VEN PHASE =0,46A P=0W R.F 32MN I.E.C 34 (87) Ready to autotune The drive is able to perform either a stationary or a rotating autotune. The motor must be at a standstill before an autotune is enabled. To perform an autotune: Set Pr 00.038 = for a stationary autotune or set Pr 00.038 = 2 for a rotating autotune Close the drive enable signal (apply +24 V to terminal 3 & 34). Autotune The drive will display Ready. Close the run signal (apply +24 V to terminal 2 or 3). The lower display will flash tuning while the drive is performing the autotune. Wait for the drive to display Inhibit and for the motor to come to a standstill. Remove the drive enable and run signal from the drive. Autotune complete When the autotune has been completed, Pr 00.038 will be set to 0 Save parameters Save parameters Ready to run Run Increasing and decreasing speed Stopping Select SAVE in Pr mm.000 (alternatively enter a value of 000) and press the Stop / Reset button to save parameters. The drive is now ready to run the motor. Turning the speed potentiometer will increase and decrease the speed of the motor. To stop the motor under ramp control, open either the run forward or run reverse terminal. If the enable terminal is opened while the motor is running, the motor will coast to a stop. R S σl S cos Unidrive M400 Quick Start Guide 5

Zero frequency Run forward Run reverse Analog input / Analog input 2 select Jog forward Digital I/O 0 V 24 V user Digital I/O Digital I/O 2 Digital input 3 Digital input 4 Digital input 5 Digital input 6 Digital input 7 24 V user 6 9 0 2 3 4 5 6 7 2 3 4 5 7 8 4 42 Analog I/O 0 V Analog input + Analog input - 0 V user Analog input 2 Analog output Analog output 2 Relay Drive ok Frequency reference Frequency reference 2 Frequency output Torque producing current output User enable / STO input User enable 2 / STO input 2 Safe Torque Off STO 0 V ST0 0 VSTO2 STO2 3 32 33 34 BR + _ DC bus/brake Thermal relay Braking resistor (optional) AC supply Motor ph/3 ph AC power supply L L2 U V L3 W NOTE The 0 V terminals on the SAFE TORQUE OFF are isolated from each other and the 0 V common. 0478-0040-02