IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Similar documents
V E2B Snap-in I/O Module

V E1B Snap-in I/O Module

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

EX-RC1 Remote I/O Adapter

Component identification

IO-LC1, IO-LC3 I/O Expansion Modules 1-3 Loadcell Inputs, 1 Digital In, 2 Out

IO-DI16, IO-DI16-L I/O Expansion Modules

EX-RC1 Remote I/O Adapter

V E1B Snap-in I/O Module

V E2B Snap-in I/O Module

EX-RC1 Remote I/O Adapter

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI8-RO4, IO-DI8-RO4-L I/O Expansion Modules 8 Inputs, 4 Outputs

V E5B Snap-in I/O Module

User safety and equipment protection guidelines

V E4XB Snap-in I/O Module

V E62B Snap-in I/O Module

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

V E3XB Snap-in I/O Module

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Micro-OPLC Installation Guide

High Speed Remote I/O Module

The identified danger could cause physical and property damage.

This guide provides basic information for Unitronics controller model V T2.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Vision OPLC. V T38 Installation Guide. General Description

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

Vision OPLC V TR6/V350-J-TR6

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

OPLC Installation Guide

UniStream HMI Panel. CPU-for-Panel

V E6B Snap-in I/O Module

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

V E3XBW Snap-in I/O Module

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

This guide provides basic information for Unitronics controllers V C30B and V T40B.

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

General Description V TR34/V130-J-TR34 V TR34/V350-J-TR34 V430J-R34 V R34/V130-J-R34 V R34/V350-J-R34

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ.

UniStream CPU-for-Panel

Vision OPLC V TR20

V E3XB Snap-in I/O Module

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

V TU24 V350-J-TU24

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ.

Vision OPLC V TR20

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes* Yes* Yes* USB device, mini-b Com Ports, separate order, user-installed

Vision OPLC. General Description.

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

High Speed Remote I/O Module

UniStream. Built-in. Installation Guide: US7-B5-B1, US7-B10-B1, US7-B5-TR22, US7-B10-TR22, US7-B5-T24, US7-B10-T24

Vision OPLC. General Description. Installation Guide V T34.

Vision OPLC V TR20/V350-J-TR20

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

No part of this document may be used for any purpose other than for the purposes specifically indicated herein nor may it be reproduced or

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

5504 Thermocouple Analog Input Module

FX1N-4EX-BD Input Expansion Board

No part of this document may be used for any purpose other than for the purposes specifically indicated herein nor may it be reproduced or

Unitronics Devices and RS485 Table Of Contents

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

FX1N-2EYT-BD Output Expansion Board

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

5521 Potentiometer Analog Input Module

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language)

UniStream Uni-I/O Modules

Conductive Level Controller

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

CPCI-PS24 24V-Power Supply

No part of this document may be used for any purpose other than for the purposes specifically indicated herein nor may it be reproduced or

X-12s Users Manual. X-12s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

PM Series Power Meter

Tempco Instruction Manual

Ultra Slim Relays 24

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

V G23 Rev: 12/04

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

X-11s Users Manual. X-11s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

5401 and 5402 Digital I/O Modules

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

Transcription:

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated outputs; functioning at 0-10V, 0-20mA, and 4-20mA. The interface between the module and the OPLC is provided by an adapter. The module may either be snap-mounted on a DIN rail, or screw-mounted onto a mounting plate. Component identification 1 Module-to-module connector 2 Communication status indicator 3 Isolated power supply indicator 4 Output connection points, AO4-AO5 5 Connection points for power supply to analog unit 6 Module-to-module connector port 7 Output connection points, AO0-AO3 7 1 6 2 3 4 5 Before using this product, it is the responsibility of the user to read and understand this document and any accompanying documentation. All examples and diagrams shown herein are intended to aid understanding, and do not guarantee operation. Unitronics accepts no responsibility for actual use of this product based on these examples. Please dispose of this product in accordance with local and national standards and regulations. Only qualified service personnel should open this device or carry out repairs. User safety and equipment protection guidelines This document is intended to aid trained and competent personnel in the installation of this equipment as defined by the European directives for machinery, low voltage, and EMC. Only a technician or engineer trained in the local and national electrical standards should perform tasks associated with the device s electrical wiring. Symbol Meaning Description Symbols are used to highlight information relating to the user s personal safety and equipment Danger protection throughout this document. When these symbols appear, the Warning associated information must be read carefully and understood fully. Caution Caution Use caution. The identified danger causes physical and property damage. The identified danger can cause physical and property damage. Failure to comply with appropriate safety guidelines can result in severe personal injury or property damage. Always exercise proper caution when working with electrical equipment. Unitronics Industrial Automation 1

IO-AO6X I/O Expansion Module 5/03 Check the user program before running it. Do not attempt to use this device with parameters that exceed permissible levels. Install an external circuit breaker and take appropriate safety measures against shortcircuiting in external wiring. To avoid damaging the system, do not connect / disconnect the device when the power is on. Environmental Considerations Do not install in areas with: excessive or conductive dust, corrosive or flammable gas, moisture or rain, excessive heat, regular impact shocks or excessive vibration. Leave a minimum of 10mm space for ventilation between the top and bottom edges of the device and the enclosure walls. Do not place in water or let water leak onto the unit. Do not allow debris to fall inside the unit during installation. Mounting the Module DIN-rail mounting Snap the device onto the DIN rail as shown below; the module will be squarely situated on the DIN rail. 3.5mm (0.137") 44.5mm (1.75") 93mm (3.66") 14mm (0.55") 60mm (2.362") 80mm (3.15") Screw-Mounting The figure on the next page is drawn to scale. It may be used as a guide for screw-mounting the module. Mounting screw type: either M3 or NC6-32. 2 Unitronics Industrial Automation

5/03 IO-AO6X I/O Expansion Module 5.8mm (0.228") 4mm (0.16") 80mm (3.15") 68.4mm (2.693") 93mm (3.66") 85mm (3.346") 4mm (x2) (0.16") Unitronics Industrial Automation 3

IO-AO6X I/O Expansion Module 5/03 Connecting Expansion Modules An adapter provides the interface between the OPLC and an expansion module. To connect the I/O module to the adapter or to another module: 1 Push the module-to-module connector into the port located on the right side of the device. Note that there is a protective cap provided with the adapter. This cap covers the port of the final I/O module in the system. To avoid damaging the system, do not connect or disconnect the device when the power is on. Component identification 1 Module-to-module connector 2 Protective cap 1 2 Wiring Do not touch live wires. Unused pins should not be connected. Ignoring this directive may damage the device. Do not connect the Neutral or Line signal of the 110/220VAC to the device s 0V pin. Double-check all wiring before turning on the power supply. Wiring Procedures Use crimp terminals for wiring; use 26-12 AWG wire (0.13 mm 2 3.31 mm 2 ) for all wiring purposes. 1. Strip the wire to a length of 7±0.5mm (0.250 0.300 inches). 2. Unscrew the terminal to its widest position before inserting a wire. 3. Insert the wire completely into the terminal to ensure that a proper connection can be made. 4. Tighten enough to keep the wire from pulling free. To avoid damaging the wire, do not exceed a maximum torque of 0.5 N m (5 kgf m). Do not use tin, solder, or any other substance on stripped wire that might cause the wire strand to break. Install at maximum distance from high-voltage cables and power equipment. 4 Unitronics Industrial Automation

5/03 IO-AO6X I/O Expansion Module I/O Wiring General Input or output cables should not be run through the same multi-core cable or share the same wire. Allow for voltage drop and noise interference with input lines used over an extended distance. Use wire that is properly sized for the load. Analog Outputs Shields should be earthed, connected to the earth of the cabinet. Do not connect unused outputs. An output can be wired to either current or voltage. Do not use current and voltage from the same source channel. The outputs COM signals are internally shorted. 0V +V Power supply + LOAD - Voltage connection + LOAD Current connection - Circuit protection device Wiring the Analog Outputs Power Supply 1. Connect the "positive" cable to the "+V" terminal, and the negative to the "0V" terminal. A non-isolated power supply can be used provided that a 0V signal is connected to the chassis. Do not connect the Neutral or Line signal of the 110/220VAC to the device s 0V pin. In the event of voltage fluctuations or non-conformity to voltage power supply specifications, connect the device to a regulated power supply. Unitronics Industrial Automation 5

IO-AO6X I/O Expansion Module 5/03 IO-AO6X Technical Specifications Max. current consumption Typical power consumption Status indicator (RUN) Isolated power indicator (ISO. PWR) Isolation Channel to bus Channel to power supply Channel to channel Analog Outputs Number of outputs 32mA maximum from the adapter s 5VDC 29mA @ 5VDC Green LED: Lit when a communication link is established between module and OPLC. Blinks when the communication link fails. Green LED: Lit when the isolated power supply is on. Yes Yes No 6 (single-ended) Output range 0-10V, 0-20mA, 4-20mA. See Note 1. Resolution (except at 4-20mA) Resolution at 4-20mA 12-bit (4096 units) 819 to 4095 (3277 units) Load impedance 1kΩ minimum voltage 500Ω maximum current. See Note 2. Conversion time 2 msec, synchronized to expansion communication. Linearity error ±0.1% Operational error limits ±0.2% Analog Power Supply 24VDC Permissible range 20.4 to 28.8VDC Max. current consumption 170mA@24VDC Environmental IP20 / NEMA1 Operating temperature 0 to 50 C (32 to 122 F) Storage temperature -20 to 60 C (-4 to 140 F) Relative Humidity (RH) 5% to 95% (non-condensing) Dimensions (WxHxD) 80mm x 93mm x 60mm (3.15 x 3.66 x 2.362 ) Weight 159g (5.6oz.) Mounting Either onto a 35mm DIN-rail or screw- mounted. Notes: 1. Note that the range of each I/O is defined both by wiring and within the controller s software. 2. When an analog output is set to use current, the output must be connected before the power is turned on. 6 Unitronics Industrial Automation

5/03 IO-AO6X I/O Expansion Module Addressing I/Os on Expansion Modules Inputs and outputs located on I/O expansion modules that are connected to an OPLC are assigned addresses that comprise a letter and a number. The letter indicates whether the I/O is an input (I) or an output (O). The number indicates the I/O s location in the system. This number relates to both the position of the expansion module in the system, and to the position of the I/O on that module. Expansion modules are numbered from 0-7 as shown in the figure below. Adapter 0 1 2 3 4 5 6 7 Expansion module identification number The formula below is used to assign addresses for I/O modules used in conjunction with the M90 OPLC. X is the number representing a specific module s location (0-7). Y is the number of the input or output on that specific module (0-15). The number that represents the I/O s location is equal to: 32 + x 16 + y Examples Input #3, located on expansion module #2 in the system, will be addressed as I 67, 67 = 32 + 2 16 + 3 Output #4, located on expansion module #3 in the system, will be addressed as O 84, 84 = 32 + 3 16 + 4. EX90-DI8-RO8 is a stand-alone I/O module. Even if it is the only module in the configuration, the EX90-DI8- RO8 is always assigned the number 7. Its I/Os are addressed accordingly. Example Input #5, located on an EX90-DI8-RO8 connected to an M90 OPLC will be addressed as I 149, 149 = 32 + 7 16 + 5 Unitronics Industrial Automation 7

IO-AO6X I/O Expansion Module 5/03 About Unitronics Unitronics Industrial Automation Systems has been producing PLCs, automation software and accessory devices since 1989. Unitronics OPLC controllers combine full-function PLCs and HMI operating panels into single, compact units. These HMI + PLC devices are programmed in a single, user-friendly environment. Our clients save I/O points, wiring, space, and programming time; elements that translate directly into cost-efficiency. Unitronics supports a global network of distributors and sales representatives, as well as a U.S. subsidiary. For more information regarding Unitronics products, contact your distributor, Unitronics headquarters via email: export@unitronics.com, or visit the Unitronics website at http://www.unitronics.com/. Under no circumstances will Unitronics be liable or responsible for any consequential damage that may arise as a result of installation or use of this equipment, and is not responsible for problems resulting from improper or irresponsible use of this device. No part of this document may be used for any purpose other than for the purposes specifically indicated herein nor may it be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and/or recording, for any purpose without written permission from Unitronics. The information appearing in this document is for general purposes only. Unitronics makes no warranty of any kind with regard to the information appearing in this document, including, but not limited to, implied warranties of merchantability and/or fitness for a particular use or purpose. Unitronics assumes no responsibility for the results, direct and/or indirect, of any misuse of the information appearing in this document nor for any use of the Unitronics products referred to herein in any manner deviating from the recommendations made in this document. Unitronics assumes no responsibility for the use of any parts, components, or other ancillary appliances including circuitry other than as recommended hereunder or other than that embodied in the Unitronics product. Unitronics retains all rights to its proprietary assets including, but not limited to its software products which are copyrighted and shall remain the property of Unitronics. Copyright protection claimed includes all Forms and matters of copyrightable materials and information legally allowed including but not limited to material generated from the software programs which are displayed on the screen of the Unitronics products such as styles, templates, icons, screen displays, looks, etc. Duplication and/or any unauthorized use thereof are strictly prohibited without prior written permission from Unitronics. All brand or product names are used for identification purpose only and may be trademarks or registered trademarks of their respective holders. Unitronics reserves the right to revise this publication from time to time and to amend its contents and related hardware and software at any time. Technical updates (if any) may be included in subsequent editions (if any). Unitronics product sold hereunder can be used with certain products of other manufacturers at the user s sole responsibility. 5408-0200-9 8 Unitronics Industrial Automation