Siemens BACnet VAV Actuator

Similar documents
BACnet Terminal Box (VAV) Controller

Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller

Siemens BACnet Programmable TEC Constant Volume

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

Siemens BACnet Programmable TEC Unit Conditioner Controller

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

Siemens BACnet Programmable TEC Unit Vent Controller

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Siemens BACnet Programmable TEC Unit Vent Controller for Smoke Control

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

BACnet Protocol Implementation Conformance (PIC) Statement

PXC Compact Series on BACnet/IP

Dual Duct Controller - One Air Velocity

oom Pressurization Con

TC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1, July 31, 2008

BACnet PTEC Controller Constant Volume - Cooling Only, Application Application Note Building Technologies

BACnet PTEC Controller Heat Pump Multi-Stage Slave Mode, Application Application Note Building Technologies

TEC Unit Conditioner Controller

TEC Terminal Box (VAV) Controller

ASHRAE s BACnet Protocol Implementation Conformance Statement (PICS)

ASHRAE s BACnet Protocol Implementation Conformance Statement (PICS)

BACnet PTEC Terminal Box (VAV) Controller. Control Applications. Product Numbers. Product Description. Warning/Caution Notation

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

NXAC-120 Area Controller

TB7300 Series Fan Coil Unit Communicating Thermostats BACnet Protocol Implementation Conformance Statement (PICS)

FXVMA Variable Air Volume (VAV) Box Controller

BACnet Protocol Implementation Conformance Statement (PICS)

NB-VAV Family Protocol Implementation Conformance Statement (PICS)

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement (PICS)

PXC Modular Series for BACnet Networks

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

BACnet Protocol Implementation Conformance Statement (PICS)

BACnet PTEC Unit Conditioner/Fan Coil P. Controller. Control Applications. Accessories. Product Description. Warning/Caution Notation

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

TALON Network Manager- 2 & 6 Express

Maverick I Commercial Packaged Rooftop Systems Unit Controller Protocol Implementation Conformance Statement (PICS) ANSI/ASHRAE , BACnet

Actuating Terminal Equipment Controller (ATEC) VAV with Reheat. Start-up Procedures Building Technologies Restricted

ECB-VAVS. Features and Benefits. Applications Cooling Only VAV Boxes Cooling with Reheat VAV Boxes Room Pressurization.

Heatronic Introduction. BAS Integration Manual. Table of Contents

Room Pressurization Controller Pneumatic Output

BACnet PTEC Heat Pump Multi-Stage Controller. Control Applications. Product Description. Product Numbers. Warning/Caution Notation

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

BACnet MS/TP-module. Data sheet. for MULTICAL 403 and 603

Actuating Terminal Equipment Controller (ATEC) VAV with Reheat - Cooling and Heating, Application Application Note

TEC VAV with 0-10V AO Heat. Modulation and CO2 Monitoring. Controller. Control Applications. Product Description. Accessories.

BACnet IP for Quantum

ASV215BF152*: VAV compact controller for laboratory and pharmaceutical applications

NS Series CO 2 Network Zone Sensors Protocol Implementation Conformance Statement

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

Room Pressurization Controller Electronic Output

Compact actuating room automation stations, BACnet/IP, AC24 V (Actuating DXR)

VZ7000 Series. BACnet Commercial Zoning System

System Controls Suggested Specification

SEZ7000 Series. Wireless Commercial Zoning System

TC Compact Series Unitary Equipment Controller

Protocol Implementation Conformance Statement (Normative) BACnet Protocol Implementation Conformance Statement

TAC Xenta 121-FC Programmable Fan Coil Application

WT-BAC-IP Gateway Protocol Implementation Conformance Statement

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

RWD68U Universal Controller

TEC Controller Extended I/O Application 2497 with Slave Mode Application Application Note Building Technologies

Zoning System TEC2647Z-2 and TEC2647Z-2+PIR Zone Controllers Protocol Implementation Conformance Statement

System-10 BTU Meter BACnet Network Interface Installation Guide

TC Modular Series for BACnet Networks

ECP-VAV Series. ECP-VAV Series. 10-Point Single Duct VAV / VVT Free Programmable Controller. Applications. Features

Sales and Engineering Data Sheet ED

ECB-VAVS and ECB-VAV Series

TAC Xenta 121-HP Programmable Heat Pump Application

NB-V3Tb Protocol Implementation Conformance Statement (PICS)

PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT (NORMATIVE) (This annex is part of this Standard and is required for its use.)

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

TEC Heat Pump Multi-Stage Controller. Control Applications. Accessories. Product Description. Product Numbers. Warning/Caution Notation

Datasheet. ECB-VAV Series. 1/8. BACnet B-ASC Single Duct VAV / VVT Controllers. Overview

clarity 3 VAV Programmable Controller

The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

Field selectable application type and room module series, via dip-switches on controller

Delta Control Unit (DCU) 3.30 BACNET PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT

BACnet VAV Actuator Start-up Guide IM 1040

BACnet. b3867 Terminal Controllers

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

Specification Sheet For electronically commutated motors

ExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet

Siemens TEC Extended I/O Controller

Underfloor Controllers

NS Series Temperature and Humidity Network Zone and Discharge Air Sensors Protocol Implementation Conformance Statement

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

BACnet Flow Controller for Fan Filter Units

Actuator Commissioning Tool

Datasheet. ECB-VAV Series. 1/8. BACnet B-ASC Single Duct VAV / VVT Controllers. Overview

Airflow Pressure Sensor

NB-ASC Family Protocol Implementation Conformance Statement (PICS)

LTEC Heat Pump DDC Controller

BACnet Integration Manual ITG-VZ7xxx-BAC-E04.doc ( _R4 Issue Date: May 31 st, 2012)

VAV compact controller KNX / PL-Link

Rotary version, three-position control

Transcription:

Technical Specification Sheet Document No. 149-481 May 30, 2012 Siemens BACnet VAV Actuator Setpoints and control parameters assigned and changed locally or remotely. Setpoints and control parameters stored in Electrically Erasable Programmable Read Only Memory (EEPROM) no battery backup required. Return from power failure without operator intervention. No calibration required, thereby reducing maintenance costs. Applications The Siemens BACnet VAV Actuator provides high performance direct digital control (DDC) of pressureindependent, variable-air-volume zone-level routines. The Siemens BACnet VAV Actuator Controller can operate stand-alone or can be networked to perform complex HVAC control, monitoring and energy management functions and is designed to reside on any BACnet control system. Features Controller integrated with actuator for ease of installation. BTL listed as a B-ASC device. Automated checkout procedure for ease of startup/commissioning and troubleshooting. PID control of HVAC systems to minimize offset and maintain tighter setpoint control. Communicates using BACnet MS/TP protocol for open communications on BACnet MS/TP networks. Siemens BACnet VAV Actuator requires only 5 VA, an advantage when sizing electrical capacity. Plenum rated controller. Slave Mode (Application 2597) VAV Cooling Only (Application 2560) VAV Cooling or Heating (Application 2561) VAV with Electric Reheat or Baseboard Radiation (Application 2562) VAV with Hot Water Reheat (Application 2563) VAV Electric Reheat with Series Fan (Application 2564) VAV Hot Water Reheat with Series Fan (Application 2565) VAV Electric Reheat with Parallel Fan (Application 2566) VAV Hot Water Reheat with Parallel Fan (Application 2567) Document No. 149-481 Page 1 of 5

Control algorithms are preprogrammed. The controller is ready to operate after selecting the application and assigning the unit s controller address. If desired, the operator may adjust the air volume setpoints in cfm (lps), room temperature setpoints and other parameters. The controller is designed for operation and modification without vendor assistance. Hardware Controller Board The Siemens BACnet VAV Actuator consists of an electronic controller, a differential pressure transducer and a damper actuator assembly. This controller provides all wiring terminations for system and local communication and power. The cable from the room sensor (purchased separately) connects to an RJ-11 jack on the controller. All other connections are removable terminal blocks. The Siemens BACnet VAV Actuator has an AI (10K Thermistor), DI (dry contact) and 4 Triac type Digital outputs. In addition to controlling the integrated damper actuator, the controller interfaces with the following external devices (purchased separately): Room temperature sensor with optional setpoint dial and night override button Service and commissioning tools Building Automation System from Siemens Building Technologies, Inc. Room Sensor The room sensor connection to the controller board consists of a quick-connect RJ-11 jack. This streamlines the installation and reduces controller start-up time. Differential Pressure Sensor VAV Actuator Specifications Controller and Actuator Power Requirements: Power Source Frequency Power Consumption Outputs Inputs Operating Temperature Range Storage Temperature Range Humidity Range Regulatory Compliance Dimensions Weight Actuator Torque Run time for 90º GDE GLB Nom. Angle of Rotation Max. Angle of Rotation Actuator Shaft Size Minimum Shaft Length 24 Vac +/- 15% 50/60 Hz 5 VA plus loads 4 Triacs, 12 VA each (requires 24 Vac source to allow switching; phase or neutral) AI (10K Ω Thermistor) DI (dry contact) +32 F to +122 F (0 C to +50 C) -20 F to +140 F (-29 C to +60 C) 10% to 95% non-condensing UL/CUL 916 PAZX/PAZX7 (Enclosed Energy Management) FCC Part 15, Class B CSA-Std. C22.2 No 205 CE Mark; C-Tick 5-9/16 H 2-15/16 W 4-3/16 D (142 mm 75 mm 106 mm) 1.26 lb (.572 kg) 550-430 44 lb-in. (5Nm) 550-431 88 lb-in (10Nm) 90 sec. at 60 Hz (108 sec. at 50 Hz) 125 sec. at 60 Hz (150 sec. at 50 Hz) 90 95 3/8" to 5/8" (8 to 16 mm) Dia 1/4" to 1/2" (6 to 13 mm) Sq. 3/4" (20 mm) Transformer Requirements and Recommended Voltages The Differential Pressure Sensor (on-board) is easily connected to the box's air-velocity sensing elements to provide measurement of the differential pressure. The measured value is converted to actual airflow in cfm (Ips) by the Siemens BACnet VAV Actuator controller. Type Class 2, 24 VAC, 50/60 Hz, SELV, PELV Page 2 of 5

Ordering Information Description Number Siemens BACnet VAV GDE Actuator 550-430 Siemens BACnet VAV GLB Actuator 550-431 Documentation Information Documentation Siemens BACnet Actuator Owner's Manual Room Temperature Sensors Technical Specification Sheet Number 125-5037 149-312P25 Page 3 of 5

s BACnet Terminal Box Controller () Date Tested: BACnet Protocol Implementation Conformance Statement Model Number Protocol Revision Software Version Firmware Version August 2005 B-ASC 550-430/ 550-431 135-2001b 1.2 BV13 1.0 Vendor Information Siemens Building Technologies 1000 Deerfield Parkway Buffalo Grove, IL 60089 www.sbt.siemens.com Description The controller is an integral part of Siemens controls system. The controller can operate stand-alone or can be networked to perform complex HVAC control, monitoring, and energy management functions. This controller communicates using BACnet MS/TP. BACnet Standardized Device Profile Device Profile Tested BACnet Application Specific Controller (B-ASC) Supported BIBBs Supported BIBBs BIBB Name Tested DS-RP-B Data Sharing-ReadProperty-B DS-RPM-B Data Sharing-ReadPropertyMultiple-B DS-WP-B Data Sharing-WriteProperty-B DM-DDB-B Device Management-DynamicDeviceBinding-B DM-DOB-B Device Management-DynamicObjectBinding-B DM-DDC-B Device Management-DeviceCommunicationControl-B Page 4 of 5

Standard Object Types Supported Object Type Creatable Deletable Analog Input No No Analog Output No No Binary Input No No Binary Output No No Device No No Data Link Layer Options Data Link Options MS/TP Master 9600, 19200, 38400, 76800 MS/TP Slave 9600, 19200, 38400, 76800 Segmentation Capability Segmentation Type Supported Able to transmit segmented messages No Able to receive segmented messages No Window Size (MS/TP product limited to 1) Device Address Binding Yes Static Binding Supported Networking Options No Static Binding Supported Character Sets Character Sets supported ANSI X3.4 Information in this document is based on specifications believed correct at the time of publication. The right is reserved to make changes as design improvements are introduced. or company names mentioned herein may be the trademarks of their respective owners. 2012 Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 Your feedback is important to us. If you have comments about this document, please send them to sbt_technical.editor.us.sbt@siemens.com. Document No. 149-481 Printed in the U.S.A. Page 5 of 5