ImproX IXP20 Controller INSTALLATION MANUAL

Similar documents
Amano Nexus Lite Controller INSTALLATION MANUAL

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

ISC GB-XX ISC GB-XX ISC GB-XX ISC GB-XX

Digital I/O Module. Impro (DIO) Digital I/O Module INSTALLATION MANUAL

MULTI-DISCIPLINE READERS. ImproX Multi-discipline Readers INSTALLATION MANUAL SPECIFICATIONS MODEL NUMBER: MDR GB-XX MDK GB-XX

Cluster Controller. Impro (CCM) Cluster Controller Module INSTALLATION MANUAL

UniScan. Impro UniScan Controller INSTALLATION MANUAL

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

C5S120 Installation and Connection Guide

6222 Two Door Module Technical Operations Manual

Quick Start Installation Guide

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

CP150B Vandal & Weather Resistant Keypad Security Systems

REX F-0-9 Standalone or Access Controller

Installation Instructions

Two Door Controller GEN-045

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

SNAP, CLICK, DONE. Getting Started Guide

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

FL MC 2000E (SM40) LC

Connecting a Cisco Input Module

Suprex RS-485 SPX-7500 Wired Reader-Extender

IEI emerge MicroNode Install and Setup Guide. Contents

PR602LCD v1.0 Installer Manual Rev. A

Installation guide for PR302 v2.0 Rev. E

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

Installing Sentor. Hardware Installation

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags

Installation Instructions (KF-2000)

GV-AS/EV Controller. User s Manual

Digital Keypad Introduction

F7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Xpass S2. Installation Guide. Intelligent IP Access Control Reader EN XPS2 V1.11.

ACCESS CONTROL SYSTEM

Access Control Technology Ltd. reserve the right to change the contents of this manual and the system it applies to without prior notice.

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

Copy Machine Reader. Installation and Setup Guide

A TCP/IP network CAT 5 cable If the network is faster than 10baseT a switching hub will be needed Static IP address

Datenblatt / Specifications. ACR880 GPRS Portable Smart Card Terminal. idvation GmbH

Cardax Prox Plus Mifare Reader

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Access control panel U-Prox IC E (Elevator control)

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

GV-EL124S Electric Strike

F1000 User's Manual. (Version: V1.01)

MR51e Reader Interface

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/09.

IPassan Installation guide

TruPortal Dual Door Interface Module Quick Reference

NS1 Connection Unit Guide

ACR880 GPRS Portable Smart Card Terminal

W3-H Waterproof Keypad/Reader/Controller

EP/2 Installation Instructions

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

PR402 v2.0 Installer Manual Rev.C

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro 1500 Single Door IP Controller

B-33. Hardware and Install Manual. (DC 12V / PoE)

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

2-Way Wireless I/O Expander Installation Guide

User Manual. PCKeypad Wireless Keypad

Wireless Key fob, Key pad & Receiver Range

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Quick Start Installation Guide

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

Nexus Lite (Web Interface)

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

GC 055. GSM Remote Monitoring. Operating and installation instructions

ACCESS CONTROL Products 2017

Fibre Modem - Single-mode

Zodiac FR100 TM INSTALLATION MANUAL

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

8 Button IP Controller Installation and Operation Manual AV-IP-C8-WH

CV5XX0A-X-XX Access Control Door Reader supports Mifare DESFire EV1 and Mifare Plus The family members are: Security Features for Mifare DESFire

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers

SPX-7400_SPX-7410_MAN_161028

W3-M. Metal waterproof standalone access control/reader. User Manual

STANDALONE INTERFACES USB-DMX 512 & 1024 CHANNELS V.1.1

Cardax FT Controller 3000

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

F11 Installation Guide. Version: 1.0 Date: Jul. 2010

EL-ST100 KEYPAD CONTROLLER

Model MUGAPLM Multi-Unit Gate Access Panel. MUGAPLM Installation & Assembly

Installation & Operation Guide

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

Suprex Ethernet SPX-7200 Ethernet Reader-Extender

GV-AS Controller. Installation Guide

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3

Installation Instructions for the AUTOcard-SA System

Transcription:

MODEL NUMBER: ISC920-0-0-GB-XX ISC921-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry) environment similar to IP40. The Controller is not sealed against water. Input Voltage... 10 V DC to 30 V DC, polarity sensitive. Power Requirements (ISC920) Current (ma) Power (W) 12 V DC with no peripherals connected and relays off... 75 0.90 24 V DC with no peripherals connected and relays off... 40 0.96 Power Requirements (ISC921) 12 V DC with no peripherals connected and relays off... 130 1.56 24 V DC with no peripherals connected and relays off... 60 1.44 Relay Power Requirements... An additional ~0.4 W per Relay in use. Real Time Clock (RTC) Backup Battery Battery Type... 1 x 3 V, CR2032, Lithium cell Battery. Battery Life... 2 Years with power OFF, 5 years with Power ON, 5 Years Storage with Battery Tab in place. Controller Communication Ethernet Port... Standard Ethernet RJ45 connector. 10/100 Base T, half or full duplex.

Terminal Communication RS485 Terminal Port Electrical Interface... RS485. Baud Rate... 38 400. RS485 Terminal Port (Continued) Data Format... Communications Protocol... Line Termination (RS485)... Reader Options 8 data bits, no parity, 1 stop bit. ImproX Secure Communications Protocol. Provision is made for line termination. Reader 1 Wiegand and Reader 2 Wiegand allow connection to the following hardware: ImproX (MDR) Multi-discipline Reader, Wiegand Readers, ImproX (IR) Infrared Receiver or the ImproX RF 4-channel UHF Receiver. The function is selectable via the DIP-switches (See Table 1). Power Output... Modes Supported... Electrical Interface... Communications Protocol... Relays Relay Output... Relay Contact Ratings... Operations... Digital Inputs 12 V DC and 5 V DC (selectable) at maximum 200 ma. Tag + PIN-code or Reason Code. TTL Full Duplex. ImproX Proprietary Protocol. 2 Relays, Form C, each with NO, COM and NC contacts. 10 A at 28 V DC, 5 A at 220 V AC, 10 A at 120 V AC. 100 000 Minimum. General Type... Detection Resistance Range... Protection Range... 4 Dry-contact inputs. < 2 kohm. +15 V continuous. Blank Space ISC304-0-0-GB-00 April 2010 Page 2

NOTE: Figure 1: End of Line (EOL) Sensing Circuit End of Line (EOL) Sensing enables the Controller to raise an alarm when somebody tampers with the circuit (that is, cutting or shorting the wires) between DOS [1] and GROUND (GND). In other words the Controller distinguishes between tampering on the circuit, and the door being in an actual Normally Open state. By placing Resistors into the circuit between DOS [1] and GROUND (GND), the Controller s Digital Input monitors a constant resistance through the circuit. When the circuit is tampered with, the Resistors are bypassed; the Controller detects the resistance change raising an alarm. Door Lock Type... Protection Range... General Frequency... Read Capability... Controller Diagnostic Indicators Buzzer Volume and Tone... Display (ISC921 Only) Type... Resolution... Colour... Back-lighting... Status LED Power On... Upgrade Mode... Incoming RS485 Data... Outgoing RS485 Data... 2 Dry-contact inputs. +15 V continuous. 125 khz and 13.56 MHz. Slim Tags, Omega Tags, Mifare Standard, Mifare Ultralite, FeliCa, Desfire, HID iclass, WriTag 128 and WriTag 2048. Single tone, with a 3-step adjustable volume. Thin Film Transistor Liquid Crystal Display (TFT-LCD). 240 x 320 Pixels. 65 K Colour Screen. Permanently on. Continuous Red. Flashing Red. Flashing Green LED. Flashing Red LED. ISC304-0-0-GB-00 April 2010 Page 3

Digital Inputs (1-4)... Relays (1 and 2)... Locked... Unlocked... Enet Act (Ethernet Activity)... Enet Spd (Ethernet Speed)... Enet Lnk (Ethernet Link)... Continuous Green on detected contact closure. Continuous Red on activation of the Relay. Continuous Green when locked. Continuous Green when unlocked. Flashing Red LED. Continuous Red for 100 Mbps (Default) Off for 10 Mbps. Continuous Red on connection to network. INSTALLATION INFORMATION Accessories Find the following when unpacking the ImproX IXP20 Controller: Either an ImproX IXP20 Twin Reader Controller with Web Interface (ISC920) supplied in a Black ABS Plastic housing. The housing consists of a Front Cover Assembly and a Mounting Plate. The Front Cover and Mounting Plate are held together with two Combi Screws (M4 x 10 mm) at the bottom of the housing. Or, an ImproX IXP20 Twin Reader Controller with Touch Screen (ISC921) supplied in a Black ABS Plastic housing. The housing consists of a Front Cover Assembly and a Mounting Plate. The Front Cover and Mounting Plate are held together with two Combi Screws (M4 x 10 mm) at the bottom of the housing. CAUTION: DO NOT use the Metal-oxide Varistors (25 Vrms, 500 A, 77 V max clamping) with mains power applications. Three Metal-Oxide Varistors, 25 Vrms, 500 A, 77 V max clamping. A 3 V, CR2032, Lithium cell Battery. NOTE: The 3 V, CR2032 Lithium cell Battery is partially installed in all models of the IXP20 Controller. An extra Fixed Address Label. General Remember the following when installing the IXP20 Controller: Communications Distance RS485 Terminal Port The RS485 communications distance between the ImproX Controller and the LAST ImproX Terminal in a cable run, MUST NOT exceed 1 km (1 090 yd). Achieve this by using good quality screened, twisted 2-pair cable, with the screen EARTHED at one end. Jumper Links Long transmission lines or multiple star connections, may cause communication problems. Placing a Jumper Link across the jumper (See Figure 3 for position) in the LAST UNIT AT THE END OF THE CABLE RUN should solve the problem. ISC304-0-0-GB-00 April 2010 Page 4

Distance between the IXP20 Controller and its Wiegand or Multi- Discipline Readers CAUTION: When implementing the 150 m (164 yd) cable distances with Impro Wiegand Readers use the 12 V power output option. For maximum, data communications distance, install the Readers no further than 150 m (164 yd) from the Controller. The cable individual conductor cross-sectional area should not be less than 0.2 mm 2 (0.0003 in 2 ). Distance between ImproX Units You can mount IXP20 Controllers directly next to each other. To avoid mutual interference, install the ImproX Readers at least 500 mm (20 in) apart. EARTH Connection Connect the IXP20 Controller to a good EARTH point. Using the RS485 Port, connect the ETH Lead to the ETH Terminal. Mains EARTH can be used, but electrical noise may exist. CAUTION: When using the IXP20 Controller with FCC approved accessories, ensure that the RS485 cable is routed through a separate grommet to the power cable. Also ensure that you use a CE approved Power Supply Unit. Arc Suppression Snubber devices are recommended for EMF Flyback and Arc Suppression when driving an inductive load with the Relay, see Figure 2. Figure 2: EMF Flyback and Arc Suppression Blank Space ISC304-0-0-GB-00 April 2010 Page 5

Installing the Real Time Clock (RTC) Backup Battery CAUTION: Remove the Battery Tab for the Real Time Clock from the Battery Holder BEFORE powering up the IXP20 Controller. First Time Use 1. Ensure that power is NOT applied to the Controller. 2. Locate the removable Battery Tab. 3. Pull the removable Battery Tab out of the Battery Holder. 4. Apply power to the Controller. Replacement NOTE: Because of the delicacy of this procedure, we recommend you contact your distributor before trying to replace the Battery. Mounting the IXP20 Controller CAUTION: Make certain that you mount the Controller on a vibration-free surface. NOTE: You can mount the IXP20 Controller onto virtually any surface including metal. Select the mounting position of the IXP20 Controller, considering accessibility, routing of wires and visibility of the Thin Film Transistor Liquid Crystal Display (TFT-LCD) and accessibility of the Keypad. Secure the enclosure to the mounting surface, using four suitable screws and wall plugs, nuts and bolts or rivets. DIP-switch Settings NOTE: Once the DIP-switch settings are modified reset the IXP20 Controller to acknowledge the new settings. Reader 1 Select and Reader 2 Select DIP-switch Settings Each of the Reader Ports has a 4-way DIP-switch to select the function of that Port. NOTE: If you set both Remote DIP-switches to the all off position then an Auto-ID will not return any Fixed Addresses. DIP-switch Position Connections 0 Advanced Wiegand Reader (ImproX Multi-discipline Readers). Full Tag codes and types. 1 ImproX (IR) Infrared Receiver. 2 Magstripe. ISC304-0-0-GB-00 April 2010 Page 6

DIP-switch Position Connections 3 Barcode (code 3 of 9) with Checksum. 4 Barcode (code 3 of 9) without Checksum. 5 Wiegand 26-bit, 44-bit, 40-bit, 37-bit and Tag + PINcode or Reason Code Mode. (Sagem MA100, MA200 or MA300). 6 Wiegand Open Format. 7 8 9 10 If the ImproX RF is connected, then Button 1 of the ImproX (QT) Quad Transmitter reports. If the ImproX RF is connected, then Button 2 of the ImproX (QT) Quad Transmitter reports. If the ImproX RF is connected, then Button 3 of the ImproX (QT) Quad Transmitter reports. If the ImproX RF is connected, then Button 4 of the ImproX (QT) Quad Transmitter reports. Table 1: Reader 1 Select and Reader 2 Select DIP-switch Settings Door Lock Select DIP-switch Settings DIP-switch Position Connections 0 No special lock control. 1 Motor Lock. 2 Pulse or Repeating Lock. 3 Fail Safe or Fail Secure with Locked or Unlocked Status (Solenoid Lock). 4 Normal Lock, no Lock or Unlock Sensors, only Emergency Mode support. ISC304-0-0-GB-00 April 2010 Page 7

DIP-switch Position Connections 5 Returns Controller to Factory Default Settings. NOTE: Return Switch 1 to the OFF position to resume normal operation. Table 2: Door Lock Select DIP-switch Settings Wiegand Modes Mode Tag Only: Tag + PIN: Tag + Reason: Terminal Action Treats all codes received as tag codes. Treats the first Wiegand code received as the tag code, and the second Wiegand code received as the PIN-code. Treats the first Wiegand code received as the tag code, and the second Wiegand code received as the Reason Code. Table 3: Wiegand Modes Wiegand Mode Rules Enter PIN-codes or Reason Codes on the Reader within 10 seconds otherwise the Controller discards the tag code. If the IXP20 Controller expects a PIN-code and receives a number greater than 65535, then the Controller assumes the number to be a tag code. The Controller discards the previously read Tag for the current one and the Controller will still expect a PIN-code. If the IXP20 Controller expects a Reason Code and receives a number greater than 65535, then the Controller assumes the number to be a tag code. The Controller discards the previously read Tag for the current one and the Controller will still expect a PIN-code or Reason Code, depending on the mode. If the Controller expects a Reason code and instead receives a number in the range 100 to 65535, the Controller assumes this is an error. The Controller discards the entire transaction, entering a new tag code starts the process again. A Wiegand Reader connected to an IXP20 Controller cannot be configured to read PAC-codes or special key codes. If using PIN-codes and Reason Codes set the IXP20 Controller switches for Wiegand 26-bit, 37-bit, 40-bit and 44-bit, not Wiegand open format. Blank Space ISC304-0-0-GB-00 April 2010 Page 8

ELECTRICAL CONNECTIONS Key Component Positions Figure 3: IXP20 Controller Key Component Positions ISC304-0-0-GB-00 April 2010 Page 9

Connecting the IXP20 Controller Figure 4 shows a typical electrical connection diagram for the IXP20 Controller. Figure 4: Typical IXP20 Controller Electrical Connections ISC304-0-0-GB-00 April 2010 Page 10

Figure 5: IXP20 Controller connected to Wiegand Reader ISC304-0-0-GB-00 April 2010 Page 11

Figure 6: Remote Port Data Connections for Third-party Devices ISC304-0-0-GB-00 April 2010 Page 12

Figure 7: Motor Lock Connection Details ISC304-0-0-GB-00 April 2010 Page 13

Figure 8: Solenoid Lock Connection Details ISC304-0-0-GB-00 April 2010 Page 14

ADVANCED SETTINGS Restoring Factory Default Settings CAUTION: The procedures below are Controller specific. Ensure that you follow the correct procedure for you model Controller. Failure to do so results in loss of the Database. Restore the Controller s factory default settings as follows: ISC920 1. Remove the Controller s Front Cover Assembly. 2. Set the Door Lock Select DIP-switch Switch 1 to the ON position (see Table 2, row 5 for details). 3. Reset the Controller by removing and then reapplying the power source. 4. With the Controller running, set the Door Lock Select DIP-switch Switch 1 back to the OFF position (see Table 2, row 5 for details). 5. Reattach the Controller s Front Cover Assembly. ISC921 CAUTION: Ensure that you return Switch 1 of the Door Lock Select DIP-switch to the OFF position. Failure to do so automatically clears the System Database on the next restart. 1. Remove the Controller s Front Cover Assembly. 2. With power applied to the Controller, toggle switch 1 of the Door Lock Select DIPswitch ON and then OFF. 3. Complete the Action textbox, by clicking the button and selecting from the following: No Change maintains user settings. Reset Admin Password restores the administrator password to factory default (12345) without resetting the System Database. Reset System Database clears the Database, restoring it to factory default settings. 4. Click the button. 5. Click the button. 6. Reattach the Controller s Front Cover Assembly. UNIT ADDRESS INFORMATION Fixed Address Once the IXP20 Controller is installed, sketch a rough site plan. Attach the loose (additional Fixed Address Label packaged with the Controller) Fixed Address Label in the position of the Controller on the sketched site plan. When the system installation is complete and all the units are represented on the site plan by their Fixed Address Labels, file the site plan for future reference. ISC304-0-0-GB-00 April 2010 Page 15

The Fixed Address Label included with the Controller is the Fixed Address for the Controller only. In addition to the Controller Fixed Address, the IXP20 Controller reports up to two Terminal Fixed Addresses. Controller s Fixed Address: 6E XX XX XX. Reader 1 s Fixed Address: 6F XX XX XX. Reader 2 s Fixed Address: 70 XX XX XX. NOTE: Where additional Terminals connect to the Controller, extra Fixed Addresses for the respective Terminals appear during the Software s Auto- ID process. MAC Address Figure 9: Sample MAC Address Label Each IXP20 Controller is supplied with a separate MAC Address Label, much like the one shown in Figure 9, which uniquely identifies each Controller. Attach the extra loose MAC Address Label, alongside the Fixed Address Label, to the Unit Location Chart enclosed (or your sketched site plan). IP Address NOTE: All ImproX IXP20 Controllers have the same IP Address (192.168.100.1). In the absence of a DHCP server, plug each Controller into the network individually and set the static IP Address. Unit Location Chart Fixed Address Label Unique Location Description ISC304-0-0-GB-00 April 2010 Page 16

Fixed Address Label Unique Location Description ISC304-0-0-GB-00 April 2010 Page 17

Fixed Address Label Unique Location Description ISC304-0-0-GB-00 April 2010 Page 18

Fixed Address Label Unique Location Description ISC304-0-0-GB-00 April 2010 Page 19

Fixed Address Label Unique Location Description Table 4: Unit Location Chart GUARANTEE OR WARRANTY CAUTION: We reserve the right to nullify the products guarantee or warranty where you have not properly installed the Metal-oxide Varistors. This product conforms to our Guarantee or Warranty details placed on our Web Site, to read further please go to www.impro.net. USER NOTES This manual is applicable to the ImproX IXP20 Controller, ISC920-0-0-GB-02 and ISC921-5-0-GB-02. (The last two digits of the Impro stock code indicate the issue status of the product). ISC304-0-0-GB-00 Issue 01 Apr 2010 IXP20\Controller\English Manuals\LATEST ISSUE\ IXP20iTR-insm-en-01.docx ISC304-0-0-GB-00 April 2010 Page 20