Xxxxx Xxxxxx OM-CP-TEMP1000IS-A. Intrinsically Safe Temperature Data Logger with Stainless Steel Enclosure INSTRUCTION SHEET MQS5096/1216

Similar documents
High Temperature Data Logger

User s Guide. OM-CP-HITEMP140-M12 High Temperature Data Logger with an M12 Probe Connector

Xxxxx Xxxxxx DC Voltage Data Logger

Xxxxx Xxxxxx Bridge / Strain Gauge Data Logger

Xxxxx Xxxxxx OM-CP-QUADVOLT. OM-CP-OCTVOLT 8-Channel Low Level DC Voltage Data Logger. 4-Channel Low Level DC Voltage Data Logger INSTRUCTION SHEET

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

User s Guide. OM-CP-HITEMP140X2 High Temperature Dual Probe Data Logger Series

User s Guide. OM-CP-SMR101A-KIT Soil Moisture Data Logger

PermaNetPlus for Pcorr+ and Permalog+ Quickstart Guide

OM-CP-THERMALERT SERIES Precision Wireless Temperature Data Loggers

1. Getting to know the gimbal

User Manual 318BT. Phantom Powered Bluetooth Audio Receiver

OM-CP-RFCURRENT2000A Wireless Current Data Logger

User s Guide RDXL6SD-USB. Temperature Data Logger with USB. Shop online at omega.com

OM-CP-RFCO2RHTEMP2000A

User s Guide TXDIN1700. Universal DIN Rail. Shop online at omega.com SM. For latest product manuals:

User s Guide. Series. Communication Manual. Shop online at omega.com SM. For latest product manuals:

FMA-7400/7500 Series Configurator

RFCO₂RHTemp2000A. Wireless CO₂, Humidity & Temperature Data Logger. Product User Guide

PowerView Motorization

User s Guide. OM-HL-SH Series. Single Channel Temperature and Humidity Data Logger, Handheld. Shop online at omega.com

User s Guide. OM-HL-SP Series. Single Channel Temperature and Humidity USB Data Logger, Pen Size. Shop online at omega.com

User s Guide OM-SGD-28-M. Shop online at omega.com. Smart Graphics Display. For latest product manuals:

Product User Guide. QuadTemp and OctTemp. QuadTemp 4-Channel Thermocouple Based Temperature Data Logger

User s Guide TSD600. Shop online at omega.com SM. For latest product manuals: omegamanual.info

Element CO2 Wireless CO2, Humidity & Temperature Data Logger

LED Bluetooth Flashlight Speaker w/ DC Hand Turbine and USB Charge, Built-in Alarm PWPBT75

RTD Probe Sold Separately. RFRTDTemp2000A. Precision RTD Based Temperature Data Logger. Product User Guide

Product User Guide CTL2000. CTL2000 Carcass Temperature Data Logger with 8 Remote Thermocouple Channels

User s Guide. OM-HL-SP Series Single Channel Temperature and Humidity USB Data Logger, Pen Size. Shop online at omega.com

User s Guide CS8DPT SERIES. Benchtop Controllers. Shop online at omega.com. For latest product manuals:

Element CO2 Wireless CO2, Humidity & Temperature Data Logger. Product User Guide

Product User Guide. RFTCTemp2000A. RFTCTemp2000A Wireless Thermocouple Temperature Data Logger. *Probe Sold Separately

THANK YOU FOR BUYING FREYA - A CLINT SPEAKER

Operating and Storage Temperature 5 General Warnings 6. Extracting Data 8 WARRANTY AND LEGAL

Product User Guide. RFRTDTemp2000A. RFRTDTemp2000A Precision RTD Based Temperature Data Logger

User s Guide HHSL-101. USB Digital Sound Level Data Logger. Shop online at omega.com SM

SAVE THIS MANUAL FOR FUTURE REFERENCE. Safety Instruction. EU Conformity Statement

Inspiry Smart Box E User Manual

Product User Guide. OctProcessV2 and QuadProcessV2. QuadProcessV2-3A 4-Channel Low Level DC Current

User s Guide. ALTA Wireless Sensors and Wireless Sensor Adapter. For Use With imonnit Online Software. . System Requirements

PowerView Motorization

User s Guide TXUN-KIT. Loop Link USB Communications Interface. Shop online at omega.com

Hyndsight Vision Systems, Inc. Instructions for Use

User s Guide OM-DAQXL. Modbus Interface. Shop online at omega.com. For latest product manuals:

MD-SPBT01 Bluetooth Speaker

OMB-DAQ-TC-RACK OMB-DAQ-2416 OM-NET-1608 OM-USB-32DIO

HiTemp140-FP-TSK High Temperature Data Logger with Flexible RTD Probe and Thermal Shield

Box Contents. 1. Balance Keyboard 2. Wireless Receiver 3. Two AAA Batteries. Balance Keyboard user manual

User s Guide. OM-HL-EH-TC Series Multi-channel Handheld Thermocouple Temperature Data Logger. Shop online at omega.com

User guide. Bluetooth Keyboard BKB10

Harris Bluetooth Remote Speaker Mic

User s Guide. OM-HL-SH Series. Single Channel Temperature and Humidity Data Logger, Handheld. Shop online at omega.com

QUICK START GUIDE EJ-UW700. Bluetooth C Pen

TASER Axon Body Camera User Manual

WASP Wireless Acceleration Sensor Puck USER MANUAL

LED Wrist Band Instruction Manual

BLACKBERRY RADAR H2 ITC100 1 ITC100 2 February 2019

User s Manual. Federal Communications Commission (FCC) and Industry Canada Statements. Trademark Information and Copyright Notice

Quick Start Guide VZ-X Wireless, HDMI & USB Document Camera

Magellan RoadMate 6630T-LM GPS Navigator & HD Dash Cam Combo. Quick Start Guide

1. Product Description

READ ME FIRST QUICK INSTALL GUIDE. Wireless Controller XWC Includes: One: XWC-1000 Wireless Controller One: Rack Mount Kit One: Power Cord

EcoView 8 DO Module Installation and Commissioning

User s Guide TX69. Universal Smart Transmitter. Shop online at. omega.com For latest product manuals: omegamanual.

Product User Guide. RFPRHTemp2000A. RFPRHTemp2000A Wireless Pressure, Humidity & Temperature Data Logger

InTemp CX500 Series Temperature Logger Manual

Avaya E169 IP Media Station Quick Reference

QUICK INSTALL GUIDE READ ME FIRST XWC Package Contents: XWC-1000 Wireless Controller. Rack Mount Kit. Power Cord. Wireless Controller

User s Guide. DPU90-CT PC COMM / Sensor Configuration Tool

Hi! Let s get started. Streaming Stick

Z-Wave Plus Smart Switch Dual Rocker. Installation Guide Ecolink Intelligent Technology Inc. PN DDLS2-ZWAVE5. A Universal Electronics Company

SynapSense 900 MHz Wireless Environmental Monitoring System Cloud User Guide Version 00

User Guide Rev for Clint ODIN - Model: ODIN We accept no liability for printing errors. Specifications are subject to change without notice -

AgileMesh Node Configuration Guide

8-Port mfi Power Strip with Ethernet and Wi-Fi. Model: mpower PRO

Contour Mouse Wireless

FT2225 Satellite M2M Terminal. Quick Start Guide

Owner Guide. Powered by by

EA_Gatekeeper model 2120

Bluetooth USB Adapter TALUS. User Guide

GETTING STARTED. Cord clip. USB charge cable. Earbud tips. Inner ear hooks. Carry case. The following items are included

Always there to help you. Register your product and get support at BT100. Question? Contact Philips.

User s Guide HHM-MG300. Wireless TRMS Multimeter and Insulation Tester. Shop online at omega.com

IP Set-top Box (STB) Model No.: SP-110. Rev

QUICK START GUIDE EO-BG950. Samsung U Flex Headphones

Product Manual. Wireless

User s Guide. DIN-190 and DIN-192 Series. Converter Boxes. Shop online at

USB 3.0 SATA HDD/SSD Dock - 1:1 Duplicator SATDOCK2REU3

AIR300 Hardware Manual for Motorola Workabout Pro-G4

We congratulate you on the purchase of a Univet illumination system - Made in Italy. To ensure safe use please observe the following notes.

Wireless Conference Microphone Bases. User Guide

User guide. Stereo Bluetooth Headset SBH80

AN-310-RT-4L2W. 310 SERIES MULTI-WAN GIGABIT VPN ROUTERS Quick Start Guide

Regulatory Information

INSTALLATION GUIDE 4- IN- ONE EMV L1 & L2 PIN PAD XPED- 8006L2-3CR, POE/USB/RS232

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course! Shop online at omega.com SM

SC SETTING UP THE CELL PHONE...3

RapidConnect ZigBee USB Stick Data Sheet

Emergency Wall Communicator

Transcription:

Xxxxx Xxxxxx Intrinsically Safe Temperature Data Logger with Stainless Steel Enclosure INSTRUCTION SHEET MQS5096/1216 Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info

Product Overview The OM-CP-TEMP1000IS-A temperature data logger is a rugged, battery powered, stand alone device which can be used to automatically record temperatures between -40 C and 80 C (-40 F to +176 F). This all in one compact, portable, easy to use device is able to measure and record data for up to 32,767 temperature readings. Intrinsically Safety Approval The OM-CP-TEMP1000IS-A has been certified by FM Approvals as Intrinsically Safe (IS) for use in Class I, Division 1, groups A, B, C, D, and Non-incendive (NI) for use in Class I, Division 2, groups A, B, C, D indoor and outdoor, Hazardous (Classified) Locations. The rating is listed as follows in the Factory Mutual approval guide: OM-CP-TEMP1000IS-A. Temperature Data Logger. IS / I / 1 / ABCD T4A Ta=80 C; NI / I / 2 / ABCD / T4A Ta=80 C These are the only safety ratings relevant to the use of this product. Use of this product in hazardous environments not specifically covered by this rating is prohibited, unless the user takes the appropriate steps to ensure the safety of the product and assumes full responsibility for its safe use. 2

Installation Guide Installing the Software Insert the Omega Software Flash Drive in an open USB port. If the autorun does not appear, locate the drive on the computer and double click on Autorun.exe. Follow the instructions provided in the Installation Wizard. Installing the Interface Cable - OM-CP-IFC400 or OM-CP-IFC406 Refer to the Quick Start Guide included in the package. Device Operation Connecting and Starting the Data Logger Once the software is installed and running, plug the interface cable into the docking station. Connect the USB end of the interface cable into an open USB port on the computer. Place the data logger into the docking station. The data logger will automatically appear under Connected Devices within the software. For most applications, select Custom Start from the menu bar and choose the desired start method, reading rate and other parameters appropriate for the data logging application and click Start. ( Quick Start applies the most recent custom start options, Batch Start is used for managing multiple loggers at once, Real Time Start stores the dataset as it records while connected to the logger.) The status of the device will change to Running, Waiting to Start or Waiting to Manual Start, depending upon your start method. Disconnect the data logger from the docking station and place it in the environment to measure. Note: The device will stop recording data when the end of memory is reached or the device is stopped, unless user selectable memory wrap is enabled. At this point the device cannot be restarted until it has been re-armed by the computer. Stopping and Downloading Data from the Data Logger Connect the data logger via the OM-CP-IFC400 or OM-CP-IFC406 docking station. Highlight the data logger in the Connected Devices list. Click Stop on the menu bar. Once the data logger is stopped, with the logger highlighted, click Download. You will be prompted to name your report. Downloading will offload and save all the recorded data to the PC. 3

Troubleshooting Tips Why is the data logger not appearing in the software? If the OM-CP-TEMP1000IS-A doesn t appear in the Connected Devices panel, or an error message is received while using either, try the following: Check that the OM-CP-IFC400 is properly connected. For more information, see Troubleshooting Interface Cable problems (below). Ensure that the battery is not discharged. For best voltage accuracy, use a voltage meter connected to the battery of the device. If possible, try switching the battery with a new OM-CP-BAT102. Ensure that no other Omega software is running in the background. Ensure that Omega Software is being used. Ensure that the Connected Devices panel is large enough to display devices. This can be verified by positioning the cursor on the edge of the Connected Devices panel until the resize cursor appears, then dragging the edge of the panel to resize it. The screen layout may also be reset in the options menu by selecting File, Options, and scrolling to the bottom. Troubleshooting Interface Cable problems Check that the software properly recognizes the connected OM-CP-IFC400 interface cable. If the data logger is not appearing in the Connected Devices list, it may be that the OM-CP-IFC400 is not properly connected. 1. In the software, click the File button, then click Options. 2. In the Options window, click Communications. 3. The Detected Interfaces box will list all of the available communication interfaces. If the OM-CP- IFC400 is listed here, then the software has correctly recognized and is ready to use it. Check that Windows recognizes the connected OM-CP-IFC400 interface cable. If the software does not recognize the OM-CP-IFC400, there may be a problem with Windows or the USB drivers. 1. In Windows, click Start, right-click Computer and choose Properties or press Windows+Break as a keyboard shortcut. 2. Click Device Manager in the left hand column. 3. Double click Universal Serial Bus Controllers. 4. Look for an entry for Data logger Interface. 5. If the entry is present, and there are no warning messages or icons, then windows has correctly recognized the connected OM-CP-IFC400. 6. If the entry is not present, or has an exclamation point icon next to it, the USB drivers may need to be installed. These are available on the software flash drive included with the OM-CP-IFC400. Ensure that the USB end of the OM-CP-IFC400 is securely connected to the computer. 1. Locate the USB-A plug of the OM-CP-IFC400. 2. If the interface cable is connected to the PC, unplug it. Wait ten seconds. 3. Reconnect the cable to the PC. 4. Check to make sure that the red LED is lit, indicating a successful connection. 4 Questions? For more details and instructions, please refer to the rest of this guide, visit us online at www.omega.com or contact us for support at 1 (800) 872-9436.

Product Maintenance Battery Replacement Materials: Replacement Battery (OM-CP-BAT102) Carefully unscrew the data logger encasement to separate the top from the bottom of the device. The battery is the purple cylinder inside the data logger. Gently slip out the old battery. Insert the new battery. Reassemble the data logger encasement by screwing the sections back together, ensuring that the fit is tightly sealed. O-Rings O-Ring maintenance is a key factor when properly caring for the OM-CP-TEMP1000IS-A. The O-Rings ensure a tight seal and prevent liquid from entering the inside of the device. Note: For more information refer to the OM-CP-TEMP1000IS-A Intrinsic Safety user notice. Recalibration Standard recalibration for the OM-CP-TEMP1000IS-A is one point, 25 C. Recalibration is recommended annually for any Omega data logger; a reminder is automatically displayed in the software when the device is due. Still need help? For more troubleshooting tips and information, refer to the built in help section visit us online at www.omega.com or contact us for support at 1 (800) 872-9436. 5

OM-CP-TEMP1000IS-A General Specifications Temperature Sensor Resistance Temperature Detector (RTD) Temperature Range -40 C to +80 C (-40 F to +176 F) Temperature Resolution 0.01 C Calibrated Accuracy ±0.5 C (0 to ±50 C) Memory 32,767 Start Modes Software programmable immediate or delay start, up to 2 years in advance Real Time Recording May be used with PC to monitor and record data in real time (PC interface not IS rated) Reading Rate 1 reading every 2 seconds up to 1 reading every 12 hours Lethality Equations Sterilization Units and Pasteurization Units are available within software with a click of a button. Calibration Digital calibration through software Calibration Date Automatically recorded within device and displayed in software Battery Type 3.6V lithium battery included, user replaceable Battery Life 2 years typical at 15 minute reading rate Data Format Date and time stamped C, F, K, R Time Accuracy +1 minute/month at +20 C Required Interface Package OM-CP-IFC400 or OM-CP-IFC406 Software XP SP3/Vista/Windows 7/Windows 8 (Omega 4 software only) Operating Environment -40 C to +80 C (-40 F to +176 F), 0%RH to 95%RH (case properly sealed) Dimensions 2.65 x.97 dia. (67.3mm x 24.6mm dia.) Weight 3oz (85g) Materials 316 Stainless Steel IP Rating Not Rated - Caution: Do not submerge this product to retain IS rating Approvals IS, CE Battery Warning WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE, FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 80 C (176 F). Specifications subject to change. See Omega s terms and conditions at www.omega.com 6

Compliance Information This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. To satisfy FCC RF Exposure requirements for mobile and base station transmission devices, a separation distance of 20cm or more should be maintained between the antenna of this device and persons during operation. To ensure compliance, operation at closer than this distance is not recommended. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence. L exploitation est autorisée aux deux conditions suivantes: (1) l appareil ne doit pas produire de brouillage, et (2) l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d en compromettre le fonctionnement. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d un type et d un gain maximal (ou inférieur) approuvé pour l émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l intention des autres utilisateurs, il faut choisir le type d antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l intensité nécessaire à l établissement d une communication satisfaisante. 7

omega.com info@omega.com U.S.A. Headquarters: Servicing North America: Omega Engineering, Inc. Toll-Free: 1-800-826-6342 (USA & Canada only) Customer Service: 1-800-622-2378 (USA & Canada only) Engineering Service: 1-800-872-9436 (USA & Canada only) Tel: (203) 359-1660 Fax: (203) 359-7700 e-mail: info@omega.com For Other Locations Visit omega.com/worldwide The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a Basic Component under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner. RETURN REQUESTS / INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA: 1. Purchase Order number to cover the COST of the repair, 2. Model and serial number of the product, and 3. Repair instructions and/or specific problems relative to the product. OMEGA s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. Copyright 2016 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.