Classic Weight Scale. Model UC-502

Similar documents
User Manual GBS-1269BT. Body Scale 4.0. version:1.0. Distributed by: Informed Clinical Sciences Corporation 1 Joy Street, Boston, USA MA 02108

Precision Health Scale UC-324NFC Instruction Manual

Please read this user manual thoroughly before using the scales to ensure correct usage. Keep a copy of the manual handy for future reference.

Congratulations. on your My Life My Shop purchase.

BLUETOOTH BATHROOM SCALE

WM+PD Digital Sphygmomanometer

Instruction Manual. PLUSCONNECT Wireless Weight Scale UC-350BLE

Precision Health Scale Model UC-321P

Jewelry Scale HT-500GD 1WMPD

POWER SUPPLY UNIT PSU-3

UC-324THW Precision Scale

Instruction Manual Manuel d instructions Manual de instrucciones Manuale di Istruzioni Bedienungsanleitung 使用手冊

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT

Activity meter. Operating Instructions. AM 1400 adevital Activity. with Bluetooth and data management in linked app

Optional Lens User s Manual

Classic Flanger effects pedal. user manual

Operating Instructions

Corded Big Button Telephone with Speakerphone

User s Manual Power Supply IM E. 5th Edition

VIS-3016 Fingerprint Recorder User Manual

Instruction Manual. Wireless Keyboard LKBWLPP13 / LKBWLPK13 / LKBWLRD13 / LKBWLBL13

User Manual. version:1.0. Thank you very much for selecting Lifesense Band 2 LS417-F.

User Manual MAX BUZZ VP-T001. version:1.0. FCC ID: 2AKPRVP-T001 Thank you very much for selecting the

SL-4700 SERIES Owner's Manual

Network Camera. Quick Guide DC-B1203X. Powered by

OWNER S MANUAL. Additional Camera Unit AC-CAM-210 Compatible with AC210 Baby Video Monitor TABLE OF CONTENTS

Card Enrollment Station. User Manual UD05870B

Operating Instructions

SAFETY PRECAUTIONS WARNING. Repairs Do not disassemble the scale. Contact your local A&D dealer if your balance needs service or repair.

Always there to help you. Register your product and get support at AEA1000. Question? Contact Philips.

POP BLUETOOTH. Руководство по эксплуатации Ögretim Kılavuzu. English. Français. Deutsch. Español. Italiano. Português العربية. Pусский.

7 Digital Photo Frame

Built-in Fanless Ionizer! BM-20. BM-22 (Smart range) BM-252. Series. Micro Analytical Balances BM-200 BM-300 BM g 0.

Powergate³ User. Instruction manual and user s guide

Operating Instructions

Auto-Cutter (JM98901) User's Manual

INSTRUCTION MANUAL CAT ecount

Multi-touch Touch-Screen. Installation Guide

V-Switch 3 User Guide

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

DSS Console and DSS Console for Attendant for Digital Super Hybrid Systems. Reference Guide ANSWER RELEASE

Powergate3+ Decoder. Instruction manual and user s guide

DS-1H05 Ethernet-over-Coax Extender. User Manual

PRECAUTIONS FOR USE. Be sure to use indoor wiring within the specified voltage requirements. For extension cord, use the specified rating or more.

For Sales + Purchasing Info, Click Page To Visit BMI Gaming (800)

DISCLAIMER: All products, logos, brand names, or companies are trademarks or registered trademarks of their respective owners!

Quick Start Guide. Gear Power Ultra Capacity Mobile Power Station GMP10K PART NO. Q1363

Quick Reference Guide

TABLE OF CONTENTS DISCLAIMER COPYRIGHT NOTICE TRADEMARK DISCLAIMER. RED Focus Operation Guide Version 1.1 August 17, 2011

Fire Fogger 1500 fog machine. user manual

DS-K1F820-F Fingerprint Recorder. User Manual UD05957B-A

BI20 OPERATING MANUAL LOCATING DEVICE TRT-BA-BI20-TC-002-EN

Manual. Polaron SMPS Watt power supply for chargers. No. S2024. Copyright Graupner/SJ GmbH

KOS-L432. WIDE TOUCH SCREEN MONITOR 7 page 2-9 INSTRUCTION MANUAL. MONITEUR ECRAN LARGE TACTILE 7 page MODE D EMPLOI

instruction manual wireless keyboard cover IMKBSBK13 (ipad Mini not included)

by A&D Pipette Management Solutions To protect research results from the threat of nonconformities Leak Tester: AD-1690

FengMi Wemax One Laser Projection TV

Instruction Manual. English Version 2.0

4P S. Wireless LAN Connecting Adapter <BRP069A42> Installation Manual

AD-4408A. Weighing Indicator for DeviceNet Interface AX-ABCC-DEVICE INSTRUCTION MANUAL 1WMPD

Video Borescope Inspection Camera

4P M. Wireless LAN Connecting Adapter <BRP069A45> Installation Manual

Hardware Manual. intelligent Touch Controller

User Manual RKD-KVM-20 / RKDS-KVM-20. WRKD-KVM-19 / WRKDS-KVM-19 Series. Series

Prestigio P371 Users manual

Auto-Cutter CL-S6621. User s Manual

QUICK START. Chromebook 2 CB30-B Series

D-SEED effects pedal. user manual

Garmin Index Smart Scale. Owner s Manual

Network Camera. Quick Guide DC-D1223WX. Powered by

Auto-Cutter. User s Manual. (For CL-S52X/53X/62X/63X, CL-S400DT,CL-E720/E730/E720DT)

V 1.0 ISSUE DATE : Feb.17, 2011

Always there to help you. Register your product and get support at CRD150. Question? Contact Philips.

To Purchase This Game, Visit BMI Gaming Or Contact International Sales at (USA)

TIBO ST-105-3HG-SB Owner s manual

Motorized Curtain Tracks Progress 50 Motor Set

U3-88c User s manual - Revision 1.2

DIGITAL TORQUE ADAPTOR

Multi-zone weather station Model: RAR501 / RAA501H USER MANUAL

LTK1100 Series Card Reader User Manual

Universal tablet keyboard case

Digital Kitchen Scale

DC-V3213XJ-4.3mm DC-V3213XJ-2.5mm

Dual Moisture Meter Pin / Pinless Moisture Meter

Instruction Manual HD-340

INSTRUCTIONS FOR USE. RECHARGEABLE System for Hearing Aids

MOVEBAND Display Quick Start Guide

Powerline Adapter Set

Quick Start Guide. GearPower 8000mAh/16,000mAh Capacity Mobile Power Station. GMP8K / GMP16K PART NO. Q1343 / Q1344

PAR-WT50R-E PAR-WR51R-E

4P Wireless LAN Connecting Adapter <BRP069B41> <BRP069B42> <BRP069B43> <BRP069B44> <BRP069B45> Installation Manual

IPCB42501 / IPCB42551

Quick Start. WS331c 300Mbps Range Extender. Step 1: Plug the WS331c into a power socket near the wireless router. Power off

POCKET MULTIMETER Model No: MM18

Network Camera. Quick Guide DC-T3243HRX. Powered by

KIP 2300 USB3. User Guide. Version QA.1

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

E8431 First Edition Model: T00CP

Transcription:

Classic Weight Scale Model UC-502 Instruction Manual Original Manuel d instructions Traduction Manual de Instrucciones Traducción Manuale di Istruzioni Traduzione ITALIANO ESPAÑOL FRANÇAIS ENGLISH 使用手冊翻譯 دليل التعليمات ترجمة 中文 عربي 1WMPD4003400

ENGLISH CONTENTS Dear Customers... Page 2 Precautions for Use... Page 2 Parts... Page 4 Accessories... Page 5 Safety and Usage Information... Page 5 Operating Instructions... Page 5 Troubleshooting... Page 7 Specifications... Page 7 Maintenance... Page 8 English 1

Dear Customers Congratulations on purchasing a state-of-the-art A&D health scale, one of the most advanced health scales available today. Designed for ease of use and accuracy, this device will facilitate your daily weight management regimen. We recommend that you read through this manual carefully before using the device for the first time. Precautions for Use The following items contain information to prevent the risk of harm or injury to yourself or other people. Please read these items carefully and be sure to use this product correctly. Danger Warning Caution This symbol indicates an immediate danger which could result in death or serious injury. This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of physical injury or damage to property. Warning Do not rely on self-diagnosis when attempting weight loss or therapeutic exercise. Follow the instructions of a physician or specialist. Do not step on the edges of the scale or jump on the scale. This may result in a fall, causing injury. The impact may also cause damage to the scale. Do not use the scale on an uneven surface. This may damage the scale. Also, the scale cannot measure accurately on uneven surfaces. Do not use the scale on a slippery surface or step on the scale with wet feet. This may result in slipping and injury. Also, the scale cannot measure accurately in these situations. English 2

Caution Do not place the scale where it is exposed to excess water or humidity such as a bathroom, where it is exposed to direct sunlight, where it is exposed directly to the air outlet of an air conditioning unit, or near fire. This may cause the scale to malfunction. This scale should only be used for weighing body weight. This scale is a precision measuring device. Do not drop the scale or expose it to vibration or powerful shocks. Do not disassemble, repair or modify the scale. This may cause malfunction or injury. Persons with disabilities should be assisted by a caregiver when using this scale. Failure to do so may result in a fall, causing injury. When installing the batteries, be sure that the + (positive) and - (negative) terminals are correct. Incorrect installation may cause overheating, battery fluid leaks or rupturing of the batteries, resulting in damage to the scale or injury. This scale is designed for personal use. Store this scale out of the reach of small children. Do not store this scale vertically. If for any reason this scale is stored vertically, be sure not to let the scale fall. Do not place any items on this scale during storage. If use of this scale is shared with a person who has an infectious disease such as a skin disease on the feet, etc., clean the scale before use. (For details on cleaning the scale, see Maintenance (P.6).) To accurately measure your weight, use the scale on a flat, hard floor. Do not use on a carpet or other soft surfaces. English 3

Parts Name/Function LCD Display UNIT key Battery Compartment Display Symbol kg Kilogram lb Pound st lb Stone Fraction stroke English 4

Accessories One CR2032 Button Cell (pre-installed with insulating sheet) User Manual If any of the accessories are missing or damaged, contact the product vendor or an A&D Sales Branch. Safety and Usage Information Your Scale and Its Environment Do not use your scale on a slippery floor or on a carpet. Do not jump onto the platform immediately after bath or with wet hands. To ensure the accuracy of the measurement, when the scale is moved or not-in-use for a long time, please place the scale on a flat surface and turn it on first. Wait until after the scale shuts off automatically to take a measurement. Do not expose the scale to extreme temperatures, humidity, moisture, direct sunlight, dust or salty air. Battery Safety When installing the battery, pay attention to the polarity indication and ensure +/- terminals are correct. Otherwise, the battery may leak, overheat or crack, and lead to injury. Remove the battery when the device is NOT in use for extended periods of time. Operating Instructions Insert the Battery Open the battery door in the back of the scale. Insert the battery (1 x CR2032 Button Cell) into the battery compartment according to the polarity indications marked on the side of the compartment. * All the digits will be shown on the LCD in full screen. Close the battery door and wait until the digits 0.0 kg are shown on the LCD. English 5

Select Measurement Unit With the battery correctly installed, press the UNIT button on the back of the scale to select measurement unit. The default measurement unit is kilogram. You may press the UNIT button to choose among kilogram, pound and stone. kg lb st lb Measure in Kilogram / Centimeter Measure in Pound / Foot Measure in Stone / Foot Start Measuring Place the scale flat on a hard surface. Step onto the platform and stand still until the numeral on the LCD stops blinking. The measuring result is displayed for about 6 seconds. Unit: kilogram Unit: Pound Unit: Stone Then the scale powers off automatically. English 6

Troubleshooting Error Description Solution The weight placed on the platform keeps fluctuating for 25 to 35 seconds. The scale will then shut off automatically. Low Battery. The scale will power off in four seconds. Overload Step off the platform for a while. Then step onto the platform and stand still until the numerals on the LCD stops blinking. Replace the battery. Please purchase the authorized battery for replacement. Stop using this scale for measurement. Specifications Product Name Bathroom Scale Dimension Scale 300mm(L) x 300mm(w) x 23.6mm(H) Net Weight Display Measurement Unit Measurement Range Division Panel 300mm(L) x 300mm(W) x 6mm(H) Approximately 1.51kg (Excluding the cells) Digital LCD, V.A. = 63mm(L) x 30mm (W) Kilogram / Pound / Stone 5kg to 180kg 0.1kg / 0.2lb Accuracy 0-50.0kg: ±0.4kg 50.1-100.0kg: ±0.5kg 100.1-150kg: ±0.6kg 150.1-180kg: ±0.7kg Working Environment Temperature 5 C to 40 C Humidity 90% RH Storage Environment Temperature -20 C to 60 C Power Source Auto-ON Auto-OFF Accessories 3V (1 x CR2032 Button Cell) SENSE ON technology 4 to 6 seconds after last operation 1. One CR2032 Button Cell (pre-installed) 2. User Manual UC-502 conforms to the requirements of the council directives on Electromagnetic Compatibility (EMC) 2004/108/EC Restriction of the use of certain Hazardous Substances (RoHS) 2011/65/EU English 7

Maintenance Do s and Don ts When carrying out general maintenance, please practice the following Do s and Don ts: DO use a dry soft cloth to wipe off dust. DO use a wet soft cloth, dipped into water or neutral detergent and wrung out, to wipe the dirt. Then use a dry soft cloth to dry up the device. DON T wash the device with water or immerse it in water. DON T use propellant, abrasive or other chemicals to wipe the dirt. This is to avoid discoloration or malfunction. DON T disassemble this device. Battery Replacement Used batteries are hazardous waste. DON T dispose of them together with the household garbage. Please refer to the local ordinances and recycling instructions regarding disposal of the used batteries. Disposal This mark Indicates this device is subject to the Waste Electrical and Electronic Equipment Directive in the European Union. To protect the environment, dispose of useless device at appropriate collection sites according to national or local regulations. English 8

A&D Company, Limited 3-23-14, Higashi-lkebukuro, Toshima-ku Takyo 170-0013 JAPAN http://www.aandd.jp A&D INSTRUMENTS LIMITED Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon, Oxfordshire OX14 1DY United Kingdom Telephone: [44] (1235) 550420 Fax: [44] (1235) 550485 A&D Australasia Pty Ltd. 32 Dew Street, Thebarton, South Australia 5031 AUSTRALIA Telephone: [61] (8) 8301-8100 Fax: [61] (8) 8352-7409 A&D Instruments India Private Limited 509 Udyog Vihar Phase V Gurgaon-122 016, Haryana, India Tel:91(124)471-5555 Fax:91(124)471-5599