Features and Benefits

Similar documents
Easy To Use OEMS Take Note

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

MOTOR STARTERS & VARIABLE SPEED DRIVES Variable speed drives

Features and Benefits

SENSORLESS VECTOR CONTROL

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

Control Mode Application and Selection Guide

Section 16. Drives AF-650GP General Purpose Drive. Standard Specifications. Environmental Conditions. Logic Controller (LC) Sequencer

A510 Heavy Duty AC Drive

SSW06. Soft Starters.

PART 1: GENERAL PART 2: PRODUCT. Phone: Fax: Web: -

F510 Fan & Pump AC Drive

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVLF

VLT 2800 DRIVE SPECIFICATIONS

SD250 VARIABLE SPEED DRIVE

Frequency Inverters WJ200 Series Compact Inverter

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF

INTRODUCING THE S V ADJUSTABLE SPEED DRIVE

ADJUSTABLE SPEED DRIVES. GX7 Series

CATALOG SELECTION / PRODUCT SELECTION

Frequency Inverters. WJ200 Series. Compact Inverter. WJ200 Series

Built-in features Built-in simplicity Built for fans & pumps

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF

SB200. VSV V/F Control Inverter. High-performance. Applications General pump & fan control HVAC Industrial motor control

60131/2 Te ESC ENT RUN ESC ENT RUN ESC ENT RUN ESC ENT RUN ESC ENT RUN. stop reset FWO REV. stop reset FWO REV. stop reset FWO REV. stop reset FWO REV

EQ5 SERIES Quick Start Guide for Constant Torque Applications

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

Specification Number: Product Name: FRENIC-Mega AC Drives for General Purpose Applications (½ - 150Hp at 230V and ½ Hp at 460V)

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter

5 MICROMASTER 420 specifications

ATV61HC11N4 SPEED DRIVE 150 HP 460 V ATV61

The SV9000. The Comprehensive Drive Solution.

A drive dedicated to variable speed control for HVAC applications

ATV61HU55M3 ATV61 5,5 kw 7,5HP 240V single phase EMC IP20

POWER ELECTRONICS / SD700 SERIES SD700 VARIABLE SPEED DRIVES

Mini Design Inverter. For applications which need tiny installation space. HNC Electric Limited

Q9 ASD LOW VOLTAGE DRIVE

The easy to use three-phase digital DC drive for regenerative and non-regenerative applications from HP

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV61QC31N4 variable speed drive ATV61Q - 315kW / 500HP V - IP20

MC Series Drives. Flexible, simple, rugged, robust!

Motor Controllers AC Variable Frequency Drives Type Variflex 3 RVLF Advance

PowerFlex 40 Sample Specification

Y07/1-01(V1.0) Goodrive20 Series Vector Control Inverter

Commander SX NEMA 4X Washdown Duty Drive

ATV71QC16N4 variable speed drive ATV71Q - 160kW / 250HP V - IP20

Motor Controllers AC Variable Frequency Drives Type Variflex 3 RVLF Advance

5 MICROMASTER 440 specifications

For additional PowerFlex 4M data and general drive information, refer to the following publications:

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

AF-600 FP AC Drive AC Adjustable Frequency Drive Guide-Form Specification

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

ATV1200A kv kva

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

ATV1200A kv kva

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

VARIABLE SPEED DRIVE

ATV71EXA2C71N4 enclosed variable speed drive ATV71 Plus kw - 400V - IP23

Technical Data and Specifications. Table 1. LCX9000 Specifications. Drive Efficiency > 95% Power Factor (Displacement).96

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

VARIABLE FREQUENCY DRIVES

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

160 AA02SF1 AF DS-D17

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

PowerFlex 400 AC Drive Guide Specification

ATV650D22N4 variable speed drive ATV650-22kW/30HP V - IP55

HVAC Products. Introducing the SED2 Variable Frequency Drives

VARIABLE SPEED DRIVES

ATV630D15N4 variable speed drive ATV630-15kW/20HP V - IP21/UL type 1

Elevator Inverter MEH426

ACH550 Product Overview

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

Commander SX Commander SX

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ATV32H055N4 variable speed drive ATV kw V - 3 phase - with heat sink

VARIABLE SPEED DRIVES

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

TR200 DRIVE STANDARD FEATURES

ATV32HU40N4 variable speed drive ATV32-4 kw V - 3 phase - with heat sink

T300MVi MEDIUM VOLTAGE DRIVES

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV32H018M2 variable speed drive ATV32-0,18 kw V - 1 phase - with heat sink

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

Important Safety Notice

TR150 DRIVE STANDARD FEATURES

ADJUSTABLE SPEED DRIVES. Q9 Series

SED2 Variable Frequency Drives

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

3 Versions CANopen fieldbus connection PROFIBUS DP fieldbus connection DeviceNet fieldbus connection Page 10/18

Transcription:

Features and Benefits s are dual rated for constant or variable torque operation. Dynamic Torque-Vector Control Dynamic torque-vector control system performs high-speed calculations to determine the required motor power for the load status. Our key technology is optimal control of voltage and current vectors for maximum output torque. z A high starting torque of 200% at 0.5 Hz.* * 180% for 40 hp or larger models. z Achieves smooth acceleration/ deceleration in the shortest time for the load condition. z Using a high-speed CPU quickly responds to an abrupt load change, detecting the regenerated power to control the deceleration time. This automatic deceleration function greatly reduces the likelihood of the inverter tripping. reduced Motor INSTABILITY at Low Speed Motor instability at low speed (1 Hz) is reduced to less than 1/2 of that achieved by conventional inverters with the dynamic torque-vector control system, in combination with a unique digital Automatic Voltage Regulator. On-Line Tuning System z On-line tuning to continuously check for variation of motor characteristics while running for high-precision speed control. z This tuning function is also available for a second motor, which allows high-precision control of the second motor after changeover of operation between two motors. Environment-Friendly Features z Provided with low-noise control power supply systems which minimize noise interference on peripheral devices such as sensors. z Equipped with terminals for connecting a DC LINK REACTOR that can suppress harmonics. z Compliant with EMC Directive (Emission) when connected to optional EMC-compliant filter. Advanced and Convenient functions z 16-step speed with timer control for conveyor applications. z Automatic energy-saving operation, PID control, cooling fan on/off control, and line/inverter changeover operation for fans and pumps. z Rotating motor pick-up control: Restarts motor without any mechanical shock by detecting motor speed where motor is coasting after momentary power failure occurs. z Automatic energy-saving operation function: Minimizes inverter and motor loss of lighter loads. Global Products and communication z Conforms to major world safety standards: UL, cul, TÜV (up to 30 hp), EN (CE marking). z Equipped with RS485 interface as standard. z Connection to field bus: Protocol options are PROFIBUS-DP, Interbus-S, DeviceNet, Modbus Plus, BACnet, and Johnson-Metasys. z Universal Digital Inputs and Outputs (DI/DO): Monitors digital I/O signal status and transmits to a host controller, helping to simplify factory automation. Intelligent Keypad Panel z Copy function: Easily copies function codes and data to duplicate inverters. z Six languages (English, French, German, Italian, Spanish, and Japanese) are available as standard. z Jogging (inching) operation from the keypad or external signal. z Remote operation using an optional extension cable up to 33 feet away. ADVANCED MONITORING AND PROGRAMMING VIA TECO LINK SOFTware z RS232/ RS485 connection via PLC or computer. z System overview screen displays drive status and up to 15 live parameters. z Keypad control simulates the operators LCD keypad right from the computer. z Meter screen provides graphical drive data for 4 parameters simultaneously. z Graphic display screen provides trend recorder: Plot and record data Store, analyze and compare trend data Function tuning

Options and Accessories The EQ5 provides users with comprehensive packages. Options include NEMA 1 conversion kits for all models at 40 hp (30 hp, constant torque) and above. REGENERATIVE BRAKING TRANSISTORS z For dynamically demanding applications z Power matched to regenerative braking resistors available as options Option i/o cards z Relay Output Card converts standard transistor outputs to relay contact outputs z Digital I/O Interface Card sets a using binary digital inputs z Analog I/O Interface Card adds an additional voltage input and an analog output at 4-20mA Fieldbus Communication Interfaces z Modbus Plus z BACnet z Profibus z Johnson-Metasys z DeviceNet z Interbus-S Remote Keypad Extension Kits z Available in lengths ranging between 2 and 10 meters (6 and 33 feet) Applications z Crushers, Grinders z Compressors z Reciprocating Machinery z Dynamometers z Water and Wastewater z Warehouse Automation z Positive Displacement Pumps z Stamping, Punch Press z Material Handling z Winders z Commercial Washing Machines z Mixers

Keypad Panel Functions and Operations led monitor In operation mode: Displays the setting, output current, voltage, motor speed, or line speed. In trip mode: Displays code indicating the cause of trip. lcd monitor In operation mode : Displays various items of information such as operation condition and function data. Operation guidance, which can be scrolled, is displayed at the bottom. In program mode : Displays functions and data. This LCD monitor has a back light future. feature. up/down keys In operation mode : Increases or decreases the or speed. In program mode : Increases or decreases function code number and data set value. unit indication Displays the unit for the information shown on the LED monitor. program key Switches the display to a menu screen or to the initial screen for operation mode or alarm mode. FwD/reV keys In operation mode : Starts the inverter with forward or reverse operation command. Pressing the FWD or REV key lights the RUN lamp. Invalid when the function code F02 (Operation method) is set at 1 (External signal operation). Shift key (column shift) In program mode : Moves the cursor horizontally at data change. Pressing this key with the UP or DOWN key, the screen changes to the next function block. Stop key In operation mode : Stops the inverter. Invalid when the function code F02 (Operation method) is set at 1 (External signal operation). reset key In program mode : Cancels the current input data and shifts the screen. In trip mode : Releases the trip-stop condition. Data Copy Keypad can be used to upload and download to duplicate drives. Function/Data Select key In operation mode : Changes the displayed values of LED monitor. In program mode : Selects the function code or stores the data.

Constant Torque EQ5 CT (Constant Torque) 230V Series Type NEMA 1 PROTECTED CHASSIS Applied Motor Nominal (HP) EQ5-2XXX-XX Output ratings Input ratings 0.25 0.5 1 2 3 5 5 7.5 10 15 20 25 30 30 40 50 60 75 100 125 0P2 0P5 001 002 003 005 007 010 015 capacity [kva] (*1) 0.6 1.2 2.0 3.2 4.4 6.8 6.8 10 13 18 24 29 35 35 46 58 72 86 113 138 current [A] (*2) 1.5 3.0 5.0 8.0 11 17 17 25 33 46 59 74 87 87 115 145 180 215 283 346 Overload capability 150% of rated output current for 1 min. 200% of rated output current for 0.5 s 150% of rated output current for 1 min. 180% of rated output current for 0.5 s Starting torque minimum 200% (torque vector control mode) minimum 180% (torque vector control mode) voltage [V] (*3) [Hz] Phases, voltage, Voltage/ variations Momentary voltage dip capability (*6) Required power supply capacity [kva] (*7) 3-phase, 200V/50Hz, 200V,220V,230V/60Hz 50,60Hz 3-phase, 200 to 230V, 50/60Hz 3-phase, 200 to 230V, 50/60Hz Voltage: +10% to -15% (Imbalance rate between phases: 2% or less) (*5), Frequency: +5% to -5% 020 Operation will continue with 165V or more. If voltage drops below 165V, operation will continue for up to 15 ms. If "Continuous operation" is selected, the output will be lowered to withstand the load until normal voltage is resumed. 025 0.4 0.7 1.3 2.2 3.1 5 5 7.2 9.7 15 20 24 29 29 38 47 56 69 93 111 030 032 040 050 060 075 100 125 150 Output ratings Input ratings Input ratings EQ5 VT (Variable Torque) 230V Series Type NEMA 1 PROTECTED CHASSIS EQ5 CT (Constant Torque) 460V Series Applied Motor 0.25 0.5 1 2 3 5 7.5 10 15 20 25 30 30 40 50 60 75 Nominal (HP) Type NEMA 1 PROTECTED CHASSIS 100 125 150 Applied Motor 0P2 0P5 001 002 003 005 007 010 015 020 025 030 032 040 050 060 075 100 125 150 0.5 1 2 3 5 5 7.5 10 15 20 25 30 30 40 50 60 75 100 125 150 200 250 300 350 350 400 450 500 600 Nominal EQ5-2XXX-XX (HP) Rated output 0P5 0.6 001 1.2 002 2.0 003 005 3.2 007 4.4 010 015 6.8 020 8.8 025 030 12 032 17 040 22 050 060 27 075 31 100 125 35 150 46 200 250 58 300 72 350 400 86 450 113 500 600 138 700 800 165 capacity EQ5-4XXX-XX [kva] (*1) Rated output current capacity [A][kVA] (*2) (*1) 1.5 1.2 2.03.02.9 5.0 4.4 7.2 8.0 7.2 1110 14 17 192224 29 31 3642 36 5548 60 68 7380 89 87 120 140 115167 202 145 242 180 300 215 331 331283 414 466 346518 590 415 Overload capability current [A] (*2) 110% 1.5 2.5 of rated 3.7 output 5.5 9 current 9 for 131 min. 18 24 30 39 45 45 60 75 91 112 150 176 210 253 304 377 415 415 520 585 650 740 Starting Overload torque 150% of rated output current for 1 min. 150% 50% of rated or more output current for 1 min. Rated capability output 200% of rated output current for 0.5 s 180% of rated output current for 0.5 s 3-phase, 200V/50Hz, 200V,220V,230V/60Hz voltage Starting [V] torque (*3) minimum 200% (torque vector control mode) minimum 180% (torque vector control mode) Rated output Voltage [V] [Hz] (*3) 50,60Hz 3-phase, 380V, 400V, 415V(440V)/50Hz, 380V, 400V, 440V, 460V/60Hz Phases, voltage, [Hz] 350,60Hz -phase, 200 to 230V, 50/60Hz 3-phase, 200 to 230V, 50/60Hz Voltage/ Phases, voltage, Voltage: 3-phase,380 +10% to to 480V,50/60Hz -15% (Imbalance rate between phases: 2% 3-phase, or less) 380 (*5), to Frequency: 440V, 50/60Hz +5% to (*5) -5% variations Momentary Voltage/ voltage Operation will continue with 165V or more. If voltage drops below 165V, operation will continue for up to 15 ms. dip Voltage: +10% to -15% (Imbalance rate between phases: 2% or less) (*5), Frequency: +5% to -5% variations capability (*6) If "Continuous operation" is selected, the output will be lowered to withstand the load until normal voltage is resumed. Required Momentary power Operation will continue with 310V or more. If voltage drops below 310V, operation will continue for up to 15 ms. supply voltage capacity dip 0.4 If "Continuous 0.7 1.3 operation" 2.2 is 3.1 selected, 5 the 7.2 output 9.7 15 will 20 be lowered 24 to 29 withstand 29 the load 38 until 47 normal 56 voltage 69 is resumed. 93 [kva] capability (*7) (*6) 111 139 Required power supply capacity 0.7 1.2 2.2 3.1 5.0 5.0 7.2 9.7 15 20 24 29 29 38 47 57 70 93 111 136 161 196 244 267 267 341 383 433 488 [kva] (*7) Output ratings *See notes 1-7 on the next pages. Notes: (*1) Indicated capacities are at the rated output voltage 230V for the 230V series and 460V for the 460V series. The rated capacity will be lowered if the supply voltage is lower. (*2) In the case of a low impedance load, such as a high- motor, the current may drop below the rated value. (*3) The output voltage cannot exceed the input supply voltage. (*4) The taps within the inverter must be changed for an input power supply rated at 380 to 398V/50 Hz or 380 to 30V/60 Hz. (*5) If the imbalance between phases exceeds 2%, use a power-factor correcting DC reactor(dcr). Please refer to the equation on the next page. (*6) The test was conducted under the standard load conditions stipulated by the JEMA committee (at the load equivalent to 85% of the nominal applied motor hp). (*7) Indicates the values required when using a power factor correcting DC reactor (DCR) with a loaded nominal applied motor (optional for inverters of 75 hp/ct, 100 hp/vt or less).

Variable Torque EQ5 VT (Variable Torque) 230V Series Type NEMA 1 PROTECTED CHASSIS Applied Motor Nominal (HP) EQ5-2XXX-XX Output ratings Input ratings capacity [kva] (*1) current [A] (*2) Overload capability Starting torque voltage [V] (*3) [Hz] Phases, voltage, Voltage/ variations Momentary voltage dip capability (*6) Required power supply capacity [kva] (*7) 0.25 0.5 1 2 3 5 7.5 10 15 20 25 30 30 40 50 60 75 100 125 150 0P2 0P5 001 002 003 005 007 010 015 020 025 0.6 1.2 2.0 3.2 4.4 6.8 8.8 12 17 22 27 31 35 46 58 72 86 113 138 165 1.5 3.0 5.0 8.0 11 17 22 29 42 55 68 80 87 115 145 180 215 283 346 415 110% of rated output current for 1 min. 3-phase, 200V/50Hz, 200V,220V,230V/60Hz 50,60Hz 50% or more 3-phase, 200 to 230V, 50/60Hz 3-phase, 200 to 230V, 50/60Hz Voltage: +10% to -15% (Imbalance rate between phases: 2% or less) (*5), Frequency: +5% to -5% Operation will continue with 165V or more. If voltage drops below 165V, operation will continue for up to 15 ms. If "Continuous operation" is selected, the output will be lowered to withstand the load until normal voltage is resumed. 0.4 0.7 1.3 2.2 3.1 5 7.2 9.7 15 20 24 29 29 38 47 56 69 93 111 139 030 032 040 050 060 075 100 125 150 *See notes 1-7 on the next pages. Applied Motor Nominal (HP) Output ratings Input ratings EQ5 VT (Variable Torque) 460V Series Type NEMA 1 PROTECTED CHASSIS EQ5-4XXX-XX capacity [kva] (*1) current [A] (*2) Overload capability Starting torque voltage [V] (*3) [Hz] Phases, voltage, Voltage/ variations Momentary voltage dip capability (*6) Required power supply capacity [kva] (*7) 0.5 1 2 3 5 7.5 10 15 20 25 30 30 40 50 60 75 100 125 150 200 250 300 350 400 450 500 600 700 800 0P5 001 002 003 005 007 010 015 020 025 030 032 040 050 060 075 100 125 150 200 250 300 350 400 450 500 600 700 800 1.2 2.0 2.9 4.4 7.2 10 13 18 24 29 35 36 48 60 73 89 120 140 167 202 242 300 331 386 414 518 590 669 765 1.5 2.5 3.7 5.5 9 12.5 16.5 23 30 37 44 45 60 75 91 112 150 176 210 253 304 377 415 485 520 650 740 840 960 110% of rated output current for 1 min. 50% or more 3-phase, 380V, 400V, 415V(440V)/50Hz, 380V, 400V, 440V, 460V/60Hz 50,60Hz 3-phase,380 to 480V,50/60Hz 3-phase, 380 to 440V, 50/60Hz (*4) Voltage: +10% to -15% (Imbalance rate between phases: 2% or less) (*5), Frequency: +5% to -5% Operation will continue with 310V or more. If voltage drops below 310V, operation will continue for up to 15 ms. If "Continuous operation" is selected, the output will be lowered to withstand the load until normal voltage is resumed. 0.7 1.2 2.2 3.1 5.0 7.2 9.7 15 20 24 29 29 38 47 57 70 93 111 136 161 196 244 267 341 383 433 488 549 610 From note (*5) on previous page: ( Max. Voltage [V] - Min. Voltage [V] ) Imbalance rate between phases [%] = 3-phase average voltage [V] x 67[%]

Common Specifications Control Operation Output Item Control method Maximum Base Starting Carrier Accuracy (stability) Setting resolution Voltage / characteristics Torque boost Accelerating / decelerating time DC injection braking Function equipped Operation method Frequency setting Explanation Sinusoidal wave PWM control (with V/F control, dynamic torque vector control) 50-120Hz variable torque setting 25-120Hz variable torque setting 0.1 to 60Hz variable setting Holding time: 0.0 to 10.0 s 0.75 to 15kHz (30 HP/CT, 40 HP/VT or less) 0.75 to 10kHz (40 to 100 HP/CT, 50 to 125 HP/VT) 0.75 to 6kHz (125 HP/CT, 150 HP/VT or more) Analog setting: +/- 0.2% of the max. @ (25 C +/- 10 C (77 F +/-18 F)) Digital setting: +/- 0.01% of the max. @ (-10 C to +50 C (14 F to 122 F)) Analog setting: 1/1000 of max. (30 HP/CT, 40 HP/VT or less), 1/3000 of max. (40 HP/CT, 50 HP/VT or more) Digital setting: 0.01Hz (99.99Hz or less), 0.1Hz (100.0Hz or more) Output voltage at base can be adjusted separately, such as 80 to 240V (230V series) or 320 to 480V (460V series). Output voltage at max. can be adjusted separately, such as 80 to 240V (230V series) or 320 to 480V (460V series). Auto: Optimum control corresponding to the load torque. Manual: 0.1 to 20.0 code setting (energy saving reduced torque, constant torque, high starting torque, etc.) 0.01 to 3600s Four accelerating and decelerating time settings are available independent of each other by selecting a combination of digital input signals. In addition to linear acceleration and deceleration, either S-shaped acceleration/ deceleration (weak/ strong) or non-linear acceleration/ deceleration can be selected. Starting : 0.0 to 60.0Hz, braking time: 0.0 to 10.0s, Braking level: 0-80% Frequency upper and lower limiter, bias, gain, jump, pick-up operation, restart after momentary power failure, switching operation from line to inverter, slip compensation control, automatic energy saving operation, regeneration avoiding control, torque limiting (2-step), PID control, second motor switching, cooling fan ON/ OFF control. Keypad panel: Run by FWD, REV keys, stop by STOP key. Terminal input: Forward/ stop command, reverse/ stop command, coast-to-stop command, alarm reset, acceleration/ deceleration selection, multistep selection, etc. RS485: Serial Commands Keypad panel: Setting by, keys. External potentiometer: POT (VR) (1 to 5kΩ, 1/2watt) Analog input: 0 to +10V (0 to +5V), 4 to 20mA, 0 to +/- 10V (FWD/ REV operation) +10 V to 0 (reverse operation), 20 to 4mA (reverse operation) Up / Down control: Frequency increases or decreases as long as the digital input signal is turned on. Multistep selection: Up to 16 steps are selectable by a combination of digital input signals. Serial Communication operation: Operation by RS 485 ModBus RTU. Program operation: Pattern operation by programming. Jogging operation: Jogging operation by FWD, REV key or digital input signals. Indication Environment Transistor outputs: Running, arrival, detection, overload early warning, etc. Operation status output signals (2) Relay outputs: Alarm output (for any fault), multi-purpose relay output signals, etc. (1) Analog: Output, output current, output voltage, output torque, power consumption, etc. 0-10V (1) Pulse output : Output, output current, output power, output torque, power consumption, etc. Digital display (LED) Output, setting, output current, output voltage, motor synchronous speed, line speed, load rotation speed, calculated torque value, power consumption, calculated PID value, PID command value, PID feedback value, and alarm code. Operation information, operational guide, functional code / name / setting data, alarm information, tester function, motor load rate Liquid crystal display (LCD) measuring function (Maximum / average current (rms) during measuring period, maintenance information (Integrated operation hours, capacitance measurement for main circuit capacitors, heat sink temperature, etc.)) Language Six languages (Japanese, English, German, French, Spanish, and Italian) Lamp display Charge indication (voltage residual). Overcurrent, short-circuit, ground fault, overvoltage, undervoltage, overload, overheating, blown fuse, motor overload, external Protective functions alarm, input open-phase, output open-phase (when tuning), braking resistor protection, CPU and memory error, keypad panel communication error, PTC thermistor protection, surge protection, stall prevention, etc. Installation location Indoor, altitude less than 3300ft (1000m), free from corrosive gas, dust, and direct sunlight (Pollution degree 2) Ambient temperature -10 (14 F) to +50 (122 F) (ventilating cover must be removed under conditions exceeding +40 (104 F) for models at 30 HP/CT, 40 HP/VT or less) Humidity 5 to 95%RH (non-condenslng) Air pressure Operation / storage : 12.5-15.4 PSI Transport : 10.2-15.4 PSI Vibration 0.12inch(3mm) from 2 to less than 9Hz, 9.8m/s 2 t from 9 to less than 20Hz, 2m/s 2 from 20 to less than 55Hz, 1m/s 2 from 55 to less than 200Hz, Storage Ambient temperature Humidity -25 (-13 F) to +65 (149 F) 5 to 95%RH (non-condensing)

Dimensions and Weights 230V and 460V Series NEMA 1 (up to 30 hp CT, 40 hp VT) EQ5-2XXX 230 V Series NEMA 1 Dimensions Inches/mm H W D a b c d e Mh Wt. Lbs./kg 0P2 & 0P5 10.24/260 4.33/110 5.12/130 0.28/7 9.69/246 0.28/7 3.78/96 0.24/6 0.24/6 4.9/2.2 001 10.24/260 4.33/110 /145 0.28/7 9.69/246 0.28/7 3.78/96 0.24/6 0.24/6 5.5/2.5 002,003 & 005 10.24/260 5.90/150 /145 0.28/7 9.69/246 0.28/7 5.35/136 0.24/6 0.24/6 8.4/3.8 007, 010 & 015 10.24/260 8.66/220 7.68/195 0.47/12 9.37/238 0.47/12 7.72/195 /10 /10 14.3/6.5 020, 025, 030 &032 15.75/400 9.84/250 7.68/195 0.47/12 14.88/378 0.47/12 8.90/226 /10 /10 23/10.5 EQ5-4XXX 460 V Series NEMA 1 Dimensions Inches/mm H W D a b c d e Mh Wt. Lbs./kg 0P5 10.24/260 4.33/110 5.12/130 0.28/7 9.69/246 0.28/7 3.78/96 0.24/6 0.24/6 4.9/2.2 001 10.24/260 4.33/110 /145 0.28/7 9.69/246 0.28/7 3.78/96 0.24/6 0.24/6 5.5/2.5 002,003 & 005 10.24/260 5.90/150 /145 0.28/7 9.69/246 0.28/7 5.35/136 0.24/6 0.24/6 8.4/3.8 007, 010 & 015 10.24/260 8.66/220 7.68/195 0.47/12 9.37/238 0.47/12 7.72/195 /10 /10 14.3/6.5 020, 025, 030 &032 15.75/400 9.84/250 7.68/195 0.47/12 14.88/378 0.47/12 8.90/226 /10 /10 23/10.5

Dimensions and Weights 230V and 460V Series Protected Chassis (30 350 hp CT and 40 450 hp VT) 8-3-2 230V and 460V Series Open Chassis (30 350HP CT and 40 450HP VT) EQ5-2XXX 40 & 50 60 75 & 100* 125* 150* 230 V Series Protected Chassis Dimensions Inches (mm) W W1 W2 W3 H H1 H2 H3 H4 H5 H6 D D1 D2 C 13.4 (340) 14.8 (375) 14.8 (375) 20.9 (530) 26.8 (680) 9.45 (240) 10.8 (275) 10.8 (275) 16.9 (430) 22.8 (580) 12.8 (326) (361) (361) 20.1 (510) 26.0 (660) N/A 11.4 (290) 21.7 (550) 24.2 (615) 29.1 (740) 29.5 (750) 34.6 (880) 20.9 (530) 23.4 (595) 28.3 (720) 28.3 (720) 33.5 (850) 19.7 (500) 22.2 (565) 27.2 (690) 27.0 (685) 32.1 (815) 20.2 (512) 22.7 (577) 27.6 (702) 27.4 (695) 32.5 (825) 0.47 (12) 0.47 (12) 0.47 (12) 0.61 (15.5) 0.61 (15.5) (25) (25 (25 1.28 (32.5) 1.28 (32.5) 0.49 (12.5) 0.49 (12.5) 10.0 (255) 10.6 (270) 10.6 (270) 11.2 (285) (360) 8.66 (220) 0.59 (15) 0.59 (15) Bolt Size M8 M8 M8 Wt. Lb (kg) 64 (29) 79 (36) 97 (44) 154 (70) 254 (115) EQ5-4XXX 40 & 50 60 75 & 100* 125* 150* & 200* 250* & 300* 350*, 400* & 450* 460 V Series Protected Chassis Dimensions Inches (mm) W W1 W2 W3 H H1 H2 H3 H4 H5 H6 D D1 D2 C 13.4 (340) 14.8 (375) 14.8 (375) 14.8 (375) 20.9 (530) 20.9 (530) 26.8 (680) 9.45 (240) 10.8 (275) 10.8 (275) 10.8 (275) 16.9 (430) 16.9 (430) 22.8 (580) 12.8 (326) (361) (361) (361) 20.1 (510) 20.1 (510) 26.0 (660) N/A 11.4 (290) 21.7 (550) 21.7 (550) 26.6 (675) 29.1 (740) 29.1 (740) 39.4 (1000) 39.4 (1000) 20.9 (530) 19.7 (500) 20.2 (512) 0.47 (12) 20.9 19.7 20.2 0.47 (530) (500) (512) (12) 25.8 24.6 25.1 0.47 (655) (625) (637) (12) 28.3 27.2 27.6 0.47 (720) (690) (702) (12) 28.0 26.6 27.0 0.61 (710) (675) (685) (15.5) 38.2 36.8 37.2 0.61 (970) (935) (945) (15.5) 38.2 36.8 37.2 0.61 (970) (935) (945) (15.5) (25) (25 (25) (25) 1.28 (32.5) 1.28 (32.5) 1.28 (32.5) 0.49 (12.5) 0.49 (12.5) 0.49 (12.5) 10.0 (255) 10.6 (270) 10.6 (270) 10.6 (270) 12.4 (315) (360) (360) 6.89 (175) 8.66 (220) 8.66 (220) 0.59 (15) 0.59 (15) 0.59 (15) Bolt Size M8 M8 M8 Wt. Lb (kg) 64 (29) 75 (34) 86 (39) 88.2 (40) 106 (48) 154 (70) 220 (100) 309 (140) EQ5 Rear Panel Cut-Out Notes: The EQ5 Protected Chassis can be mounted either by (A) Surface Mount or (B) Through Panel Mount, where the rear panel is cut out to allow the heatsink and cooling fans to protrude out of the back of the enclosure. In case B, the mounting brackets (b) are removed to the (B) position. * Ratings which have DC Choke shipped loose as standard

Dimensions and Weights 460V Series Protected Chassis (400 600 hp CT and 500 800 hp VT) Dimensions Inches (mm) EQ5-4XXX W W1 W2 W3 W4 W5 H H1 H2 H3 H4 H5 H6 H7 26.8 22.8 26 11.4 24 55.1 53.9 52.4 52.8 52.6 0.61 1.38 057 500* & 600* - (680) (580) (660) (290) (610) (1400) (1370) (1330) (1340) (1335) (15.5) (35) (14.5) 34.6 30.7 33.9 10.2 10.2 31.9 55.1 53.9 52.4 52.8 52.6 0.61 1.38 057 700* & 800* (880) (780) (860) (260) (260) (810) (1400) (1370) (1330) (1340) (1335) (15.5) (35) (14.5) Bolt Wt. Con t D D1 D2 D3 D4 D5 D6 C Size Lb (kg) 17.7 11.2 0.25 1.97 3.94 1.38 4.53 0.59 551 500* & 600* (450) (285) (6.4) (50) (100) (35) (115) (15) (250) 17.7 11.2 0.25 1.97 3.94 1.38 4.53 0.59 794 700* & 800* (450) (285) (6.4) (50) (100) (35) (115) (15) (360) EQ5 Rear Panel Cut-Out Notes: 1. The EQ5 Protected Chassis can be mounted either by (A) Surface Mount or (B) Through Panel Mount, where the rear panel is cut out to allow the heatsink and cooling fans to protrude out of the back of the enclosure. In case B, the mounting brackets (b) are moved to the (B) position. 2. When mounting the unit through the panel, an alternative method of mounting the inverter is to use a bottom (customer supplied) bracket and the bottom mounting holes would not be necessary. Also the panel cut-out dimension will be (H4). * Ratings which have DC Choke shipped loose as standard

l Basic Wiring Diagram 7 7.5) 7.5)

TECO-Westinghouse Motor Company 5100 N. IH-35 Round Rock, Texas 78681 1-800-279-4007 www.tecowestinghouse.com D-EQ5 10-10