H704-42(H)(E), H704-42/1(H)(E)

Similar documents
GE Industrial Solutions. DET-756 Installation Instructions ASPMETER Panelboard Monitoring System

ENERCEPT H8035/H8036 DANGER NOTICE CAUTION. Networked Power Transducer (Modbus RTU) INSTALLATION GUIDE QUICK INSTALL TABLE OF CONTENTS

installation Operation ADDRESS product diagram H8030/8031 INSTALLATION GUIDE

Enercept H8035/H8036 Modbus Energy Meter Networked kw/kwh Transducers

BCM2 Series Branch Circuit Monitors Quick Setup Guide

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

PM Series Power Meter

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter

PowerLogic High Density Metering System 1-Meter Enclosure

ASTAT XB/XBm Remote Operator

PowerLogic BCPM Functions and characteristics

Carbon Monoxide Sensor - ModBus

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

SEM3 - Embedded Micro Metering Module

THE CTB08D LIGHT CONTOLLER

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

Measurement Systems Datascan Installation and User Guide

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

EnerSure Installation Guide

and Network Interface Modules Installation Instructions

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

Nokeval. FD100 series. User Manual

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic

Digital ac/dc (24V) Input Module

Analog Voltage Combination Module

BCPM Series Panelboard Monitoring Systems

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

P3-SCM. General Specifications

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

SAVE THESE INSTRUCTIONS

Trident and Trident X2 Digital Process and Temperature Panel Meter

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

General Specifications. P2-SCM Serial Communications

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

MIC-2 MKII, Multi-instrument DATA SHEET

Installation and Programming Manual

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

MODEL: R2K-1 SEN TRONIC AG. R2K Series

EX-RC1 Remote I/O Adapter

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

EX-RC1 Remote I/O Adapter

SCC Inc. TS Series. Technical Instructions Document No. TS-1050 March 10, TS Serial Communication Kits for use with LMV3, LMV5, and RWF Controls

Technical Specificaions. kwh Energy Meter

PanelView Plus/VersaView CE Terminals and Display Modules

Technical Specifications. Dual Source kwh Energy Meter

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

User s manual. Easy Scan XT3 LED

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

S66 Series Electronic Fan Speed Control

Rhino PSM Power Supplies. Operating Instructions

EX-RC1 Remote I/O Adapter

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

Remote I/O Scanner. Installation Instructions. (Catalog Number 1747-SN)

IIM Warwick Court. Williamsburg VA REV 5

24 Input/8 Output AC Block I/O Module

em4 Accessories Digital expansions

EM270. Multi-channel power analyzer. Benefits. Description

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

E3xA, E3xB, E3xC, E3xE

Quick Start Installation Guide

Tempco Instruction Manual

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Features. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Output Connectors. Overvoltage Protection. Over Temperature Protection

PICO PROTECTOR PG-06 & PK-06 Series

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Installation & Operation Guide

Power Xpert Branch Circuit Monitor

MGate 5105-MB-EIP Quick Installation Guide

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

OMX-CI-RS232 Control Interface

ETM-2050/ETM-2051 Service Manual

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

DeviceNet Master (Scanner) HE800DNT450 / HE-DNT450* DeviceNet Communications * HE- denotes plastic case.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Power Supply and Fan Module Installation

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

EM49xxx Series Multi-Circuit Meters

INSTALLATION GUIDE OPERATION INSTALLATION PRODUCT DIAGRAM H8025/8026. Disconnect and lock out power before installation.

User's Guide. Model W 3-in-1 Switching DC Power Supply

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

PLC Racks IC697CHS782/783

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

INSTALLATION INSTRUCTIONS Protocol Energy Meter EM-RS485 and Current/Voltage Transducers DANGER WARNING

DC Outdoor Power Supply/Chargers

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Power Monitor Sensor User Manual

Transcription:

POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (<95% RH, non-condensing) Storage Temp. Range -40 to 70 C (-40 to 158 F) Control (Mains) Power Source 1 VAC L-N, 50/60 Hz (8/230 VAC for H704-42/1(E)) (+10/-25%) Input current < 75 ma Primary Fusing 250 VAC/100 ma, (T) 5 x mm, (if equipped) Littelfuse 218 series or equivalent Altitude of Operation 3 km max. Measured Current Inputs: Number of Channels 42 Frequency 50/60 Hz Sample Frequency 1280 Hz Update Rate 1.2 sec Accuracy ±2% from 5 A to 50 A * Overload Capability Tested to 10,000 A single-cycle Connection to Conductor Solid-core toroid Measured Currents Current range 0-50 A (max. conductor size is AWG#6 THHN) Measured Currents, H version Current range 0-100 A (max. conductor size is AWG#2 THHN) Network Communications: Type Modbus RTU Connection DIP switch-selectable 2-wire or 4-wire Address DIP switch-selectable address 1 to 247 Baud Rate DIP switch-selectable 2400, 4800, 9600, 190 Parity DIP switch-selectable NONE, ODD, EVEN Communication Format 8-data-bits, 1-start-bit, 1-stop-bit Termination 5-position depluggable connector (T+ T- SHIELD T+/R+ T-/R-) Defaults: Warning Register 60% of current sensor max. (configurable) Alarm Register 70% of current sensor max. (configurable) Breaker Size Register A * In case of a current fault above 60A (1 for the H version), all adjacent channels will report higher than actual readings. To prevent this from causing over-current warnings and alarms, configure the warning and alarm delays for a longer time period than the response time of the breaker. MODEL # H704-42(H)(E) H704-42/1(H)(E) CT SPACING 3/4" on center 1" on center quick install 1. Disconnect and lock out power. 2. Mount current sensor strips adjacent to breaker terminations. 3. Verify that serial numbers on CT and board match. 4. Mount board onto electrical/fire enclosure. 5. Connect CTs and wire the board. 6. Reconnect power. 7. Configure communication and addressing parameters. Note: Data acquisition board and CT strips are calibrated as a set. Match the serial numbered parts together. For a 400A Panel, order the H704-42Y55 Z2366-0M page 1 08 Veris Industries USA 800.354.8556 or 503.598.4564 / support@veris.com 081

8 6 4 2 H704 INSTALLATION GUIDE operation product diagram The H704-42 Branch Current Monitor is a current sensing device designed to monitor all 42 poles of a panel board. Designed for critical load monitoring such as Co-location Data Centers and lighting panels, the H704-42 provides important branch circuit amperage and capacity information. By reporting current levels and initiating capacity warnings and alarms, the H704-42 allows the management of power and eliminates open circuits caused by overloaded breakers. 38 36 34 32 30 28 26 24 22 18 16 14 12 10 42 40 The H704-42 consists of a Data Acquisition Board and two 21-unit current sensor strips. The strips are mounted on each side of the panel board along the termination points of each breaker. The conductor passes through the appropriate current sensor before terminating at the breaker. Each strip transmits the current data to the Data Acquisition Board through snap on ribbon cable. An optional hardware kit is available for mounting the H704-42. 10 11 12 13 Data is transmitted using an RS485 Modbus protocol. Each Data Acquisition Board is addressed on the modbus daisy chain network. Setup is made easy with a PC based configuration tool which allows for global or individual selection of breaker size, warning levels, and alarm levels. *For 8/230VAC Power Connection version, order H704-42(H)(E)/H704-42/1(H)(E) dimensions Circuit Board and Mounting Bracket 1. RS 485 2 or 4-Wire Connection: Daisy chain multiple H704-42's using a 2-wire or 4-wire modbus network. 2. Optical Communications Isolation: Optical isolators are used to separate 1 VAC portions of the circuit from the RS485 network. 3. Alive LED: Flashes once per second to indicate correct operation. If steadily lit or out, indicates internal failure. 4. 50-Pin Ribbon Cable Connectors (Data Acquisition Board): 18-inch (457 mm) ribbon cables are provided standard** for easy snap connection of current sensor strips to this point of the Data Acquisition Board. 5. Control (Mains) Power Connection*: Easy 2-wire 1 VAC line to neutral 50/60 Hz. 6. 250VAC 100mA Time Delay Fuse: Fused power connection for circuit protection. 7. Power Transformers: Linear power supply for reliability and low noise 8. Baud Rate & Parity Selection Switches: Field selectable RS-485 serial interface control. 9. Modbus Address Dip Switches: Each Modbus device must have a unique address. These switches must be set to assign an individual address before the device is connected to the network. 10. T LED: Indicates successful transmission of information over the Modbus network. 11. R LED: Indicates data received on the Modbus network 12. Current Sensors: Each current sensor is capable of monitoring conductors carrying up to a maximum of 50 amps. Maximum wire size capacity is #6 AWG THHN. H version can monitor up to 100 amps with a maximum wire size capacity of #2 AWG THHN 13. 50 Pin Ribbon Cable Connectors (CT Strips): 18" ribbon cables are provided standard** for easy snap connection of Data Acquisition Board strips to this point of the current sensor strips *For 8/230VAC Power Connection version, order catalog number H704-42/H704-42/1E. **Additional sizes are available for sale. Z2366-0M page 2 08 Veris Industries USA 800.354.8556 or 503.598.4564 / support@veris.com 081

safety Installation UL listed under standard 508 as an "open type device." Installation category: CAT II or CAT III Critical components evaluated to UL 1950. 1. Inspect the Mounting Bracket Kit. The acquisition and interconnection boards are mounted to the bracket at the factory. Data Acquisition Board The H704 Series must be installed in as appropriate electrical and fire enclosure per local regulations. For use in a Pollution Degree 2 or better environment only. A Pollution Degree 2 environment must control conductive pollution and the possibility of condensation or high humidity. Consideration must be given to the enclosure, the correct use of ventilation, thermal properties of the equipment and the relationship with the environment. This symbol indicates an electrical shock hazard exists. Documentation must be consulted where this symbol is used on the product. 1.12" (28 mm) 11.375" (289 mm) 5.75" (146 mm) Data Acquisition Board Mounting Bracket H704-42 50A Solid-Core CT Strips 19.5" (241 mm) 1.0" (26 mm) 0.35" opening (9 mm) 0.75" on center (19 mm) 24.0" H704-42/1 1.0" 0.35" opening 1.0" on center 100A Solid-Core CT Strip 0.75 19 19.5 495 1.0 25 H704-42(H) 0.4 opening 10.16 Side View 0.75 on center 19 Right strip shown 1.3 33.31 515 1.2 31 Z2366-0M page 3 08 Veris Industries USA 800.354.8556 or 503.598.4564 / support@veris.com 081

42 40 38 36 34 32 30 28 26 24 22 18 16 14 12 10 8 6 4 2 H704 INSTALLATION GUIDE Installation, cont. 2. Disconnect power to the electrical panel and lock it out. Connect 2-wire 1 VAC* power to power terminals. (see Product Diagram for location) Observe polarity. 3. Current Sensor Strip Installation: Locate panel board screws which are 16.50 (4 mm) apart and allow the current sensors to line up directly with breaker terminations. Loosen these two screws sufficiently for the brackets (1 & 2) to slip under screws. Do not remove screws completely. Slide the current sensor strip mounting bracket under these loosened screws. Be sure to face the inside of the bracket toward the breakers. Tighten screws. Repeat for the other side of the panel board. 4. Check that CT serial numbers and meter serial numbers match. Meter and CT sold as set with accuracy calibrated as a set. 5. Acquisition Board Installation: Find screw holes under panel board in side of PDU chassis or panel. Attach Data Acquisition Board bracket using screws and bolts provided. 6. Pass power wiring through appropriate CT's observing local code for bending radius. Current sensors accommodate for #6 THNN sized conductor. (max. diameter 0.35 /9 mm). Use insulated wire only. * For 8/230VAC Power Connection version, order H704-42E/H704-42/IE 16.50 distance between bracket screws LEFT RIGHT 4 R Mounted Data Acquisition Board Z2366-0M page 4 08 Veris Industries USA 800.354.8556 or 503.598.4564 / support@veris.com 081

wiring Power must be disconnected and locked out before making any wiring connections. 1. Connect 2-wire or 4-wire Modbus RS485 daisy chain network. Master or Slave 2-Wire T T+ SHLD R R+ T T+ SHIELD SHIELD Master (Network Display) Slave (H663 series) 4-Wire T T+ SHLD R R+ T T+ T T+ SHLD R R+ T T+ SHIELD SHIELD NOTES A. The Modbus cable should be mechanically secured where it enters the electrical panel. B. All Modbus devices should be connected together in a daisy-chain fashion, and properly terminated. C. The Modbus cable should be shielded twisted pair wire such as Belden 11A. The cable must be voltage rated for the installation. 2. Use the Software Configuration Tool to set up breaker size, warning levels, and alarm levels. This tool is available online at http://www.veris.com/modbus.asp 3. Reconnect power. WARNING: After wiring the Modbus cable, remove all scraps of wire or foil shield from the electrical panel. This could be DANGEROUS if wire scraps come into contact with high voltage conductors! Disconnect and lock out power source before making any connections. Connect 2-wire 1 VAC power to power terminals. See Product Diagram section for location. Observe polarity. Z2366-0M page 5 08 Veris Industries USA 800.354.8556 or 503.598.4564 / support@veris.com 081

configuration 1. Communications Configuration: Communications parameters for the H704 series are field selectable for your convenience. Please see Product Diagram section for selector location. The following parameters are configurable: Parity or Parity: Odd or even Wiring: Two or four Baud Rate: 2400, 4800, 9600 or 190 Baud Rate and Parity Switch Setttings 1 2 Switch # 3 4 5 6 7 8 Wiring, Baud Rate, Parity Wiring 2 wire 4 wire DESIRED RESULT Baud Rate 2400 Baud 4800 Baud 9600 Baud 190 Baud Parity None Even Odd The values of each dip switch are as follows: Example: 2-wire 9600 Baud No Parity (Default ly) 2. Address Configuration: Each Modbus device on a single network must have a unique address. The switch block must be set to assign a unique address before the device is connected to the Modbus RS485 network. If an address is selected which conflicts with another device, neither device will be able to communicate. 1=1 2=2 3=4 4=8 5=16 6=32 7=64 8=128 H704 series can be addressed as any whole number between and including 1-247. Each unit is equipped with a set of 8 dip switches for addressing. See below. = 1 To determine an address you simply add the values of any switch that is on. For example: 40 LSB MSB or O N = 1 Switch number 4 has an ON Value of 8 and switch number 6 has an ON Value of 32. (8+32 = 40) See the Communications Setup section for a pictorial listing of the first 63 switch positions. 1 2 4 8 16 32 64 128 VALUE Z2366-0M page 6 08 Veris Industries USA 800.354.8556 or 503.598.4564 / support@veris.com 081

communications setup DO NOT USE ZERO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 Z2366-0M page 7 08 Veris Industries USA 800.354.8556 or 503.598.4564 / support@veris.com 081

service Changing the Fuse 1. Disconnect and lock out power to panel. 2. Disconnect and lock out 1V Control (Mains) Power Source to Data Acquisition Board. 3. Remove old fuse. 4. Replace with new fuse, Littelfuse 218 series or equivalent. 5. Reconnect 1V to Data Acquisition Board. 6. Reconnect power to panel. 7. Check Alive LED for proper function (See Product Diagram section for location). ACCESSORIES CBL008 Cable, Ribbon, 18 in (457 mm), BCM CBL016 Cable, Ribbon, 48 in (1219 mm), BCM CBL017 Cable, Ribbon, 60 in (1524 mm), BCM CBL018 Cable, Ribbon, 72 in (1829 mm), BCM CBL019 Cable, Ribbon, 97 in (2464 mm), BCM CBL0 Cable, Ribbon, 1 in (3048 mm), BCM CBL021 Cable, Ribbon, 240 in (6096 mm), BCM Z2366-0M page 8 08 Veris Industries USA 800.354.8556 or 503.598.4564 / support@veris.com 081