THE MOST FLEXIBLE INSTRUMENTATION FOR SURVEYING AND ALIGNMENT - A HIGH PRECISION TOTAL STATION CONTROLLED BY MODERN SOFTWARE

Similar documents
HIGH PRECISION SURVEY AND ALIGNMENT OF LARGE LINEAR COLLIDERS - HORIZONTAL ALIGNMENT -

STRAIGHT LINE REFERENCE SYSTEM STATUS REPORT ON POISSON SYSTEM CALIBRATION

SURVEY AND ALIGNMENT OVERVIEW: FERMILAB MAIN INJECTOR RING

GEOMETRICAL SURVEY OF COMPACT ANTENNA TEST RANGES USING LASER TRACKER TECHNOLOGY

Leica TDRA6000 Product Brochure

1. PRECAUTIONS. Thank you for choosing RUIDE theodolite Disteo 23. Please read this manual carefully before use.

PCMM System Specifications Leica Absolute Tracker and Leica T-Products

Leica Absolute Tracker AT401 Absolutely portable

Methods and Instrumentation for the measurement of Machine Tools (according to ISO 230 and ISO 1101)

New Technologies For The Real 3D Reference Point Determination

The P P S-TBM3 Guidance System

Roll angle in 6DOF tracking. CMSC Charlotte-Concord, July 2008

PCMM System Specifications Leica Absolute Tracker and Leica T-Products

Section G. POSITIONAL ACCURACY DEFINITIONS AND PROCEDURES Approved 3/12/02

William Oren, Robert Pushor, and Robert Ruland Stanford Linear Accelerator Center Stanford University, Stanford, California ABSTRACT

Insertion Device Alignment for the Diamond Light Source

Watchmaker precision for robotic placement of automobile body parts

Softrock GeoMos Manual For AutoSlope Users

THE ALIGNMENT OF THE ADVANCED PHOTON SOURCE AT ARGONNE NATIONAL LABORATORY*

2. INITIAL ALIGNMENT 2.1 Tolerances The FFTB is composed of four straight sections as shown in fig. 1. FFTB composed of 4 Straight Sections

COMPACT RANGE CALIBRATION AND ALIGNMENT

Length, Germany, PTB (Physikalisch-Technische Bundesanstalt)

11.0 Measurement of Spindle Error Motion

Three-Dimensional Laser Scanner. Field Evaluation Specifications

Novel Magnetic Field Mapping Technology for Small and Closed Aperture Undulators

ZED Tunnel Guidance Ltd

Leica s Pinpoint EDM Technology with Modified Signal Processing and Novel Optomechanical Features

XL-80 spares list. Application note. Overview

Horizontal Positional Accuracy (HPA) How is it calculated? Gord Gamble and Peter Goodier, Practice Advisory Department

Critical Aspects when using Total Stations and Laser Scanners for Geotechnical Monitoring

Leica FlexLine TS09plus Full Precision at High Performance

Alignment Services LLC

RAILWAY PROJECT Geodetic Reference System, Geodetic Control Network and Rail Construction Measurements

COORDINATE MEASUREMENT MACHINES AS AN ALIGNMENT TOOL *

BESMAK BMT - E SERIES

Operation Manual. Autocollimator Test Wedge for quick testing of Electronic Autocollimators

good check of volumetric accuracy. However, if the mea error components. However, if the errors measured are large,

MODERN TECHNOLOGIES IN RESEARCH AND EDUCATION AT THE INSTITUTE OF GEODESY AND GEOINFORMATICS

LEICA T1800 TC1800 TCA1800

The Influence Of The Tooling Ball Reflector On The Accuracy Of Laser Tracker Measurements: Theory And Practical Tests

Alignment Software for Linear Guides

Leica Builder... Built to Build

USING A TRACKING LASER INTERFEROMETER TO CHARACTERIZE THE PLANARITY OF A PLANAR NEAR-FIELD SCANNER

Abstract. Overview of Tests

ROBOTIC TOTAL STATION PERFORMANCE IN INDUSTRIAL DEFORMATION SOLUTION

Chapter 3 Image Registration. Chapter 3 Image Registration

Study on Gear Chamfering Method based on Vision Measurement

LCLS Undulator Quadrupole Fiducialization Plan

Boosting the Efficiency of Wind Power Plants. Stringent Demands for Boosting the Efficiency of Wind Power Plants

Leica FlexLine TS06plus Top Precision meets High Efficiency

Leica Builder... Built to Build

Highly Efficient Assembly of Lenses with. OptiCentric and OptiCentric Cementing

PROCESSING OF CALIBRATION MEASUREMENTS ON EZB-3

Electronic angle measuring machine. Angle/position by means of vignetting

Aligning Parallelism of Rolls Has Never Been Faster. L-732 Precision Dual-Scan Roll Alignment System

ANTENNA ALIGNMENT IN A NEAR-FIELD FACILITY

Status report on the Survey and Alignment of the Accelerators at CERN

ALIGNMENT DESIGN AND STATUS OF TAIWAN PHOTON SOURCE WEI-YANG LAI

BEFORE YOU BUY: SEVEN CRITICAL QUESTIONS TO ASK ABOUT LASER SCANNERS. Robert Gardiner

12 Alignment. Technical Synopsis

Geometric Accuracy Investigations of the Latest Terrestrial Laser Scanning Systems

All rights reserved. The rights of DCP05 are owned by A.M.S. Accuracy Management Services Ltd., Oulu, Finland.

Patch Test & Stability Check Report

THE OPTICAL PORTABLE CMM FOR INDUSTRIAL APPLICATIONS

REMOTE SENSING OF SURFACE STRUCTURES

LED Ring Lights. LED Ring Lights

UNITEST - A new device for the static and dynamic testing of unconventional machine structures

Boosting the Efficiency of Wind Power Plants. Stringent Demands for Boosting the Efficiency of Wind Power Plants

NEW MONITORING TECHNIQUES ON THE DETERMINATION OF STRUCTURE DEFORMATIONS

CASOB Simultaneous Surveying and Drawing

ASM-IV ARGUS SURFACE METER

LEICA TPS700 Performance Series

METROLOGY SOLUTIONS THE OPTICAL PORTABLE CMM FOR INDUSTRIAL APPLICATIONS

PrismMaster. Ultra Accurate and Fully Automated Prisms and Polygons Measurement

WTS Inclinometer. All-weather radio telemetry Inclinometer system. Features. WTS Wireless Inclinometer. Dimensions

A. K. Srivastava, K.C. Sati, Satyander Kumar alaser Science and Technology Center, Metcalfe House, Civil Lines, Delhi , INDIA

Navigational Aids 1 st Semester/2007/TF 7:30 PM -9:00 PM

Chapters 1 7: Overview

In North America call toll free: Fax

SPECIFICATION FOR BLACK BODY CALIBRATION SOURCE

Version 2.0 English. Leica FlexLine TS02/TS06/TS09 Quick Guide

GeoMax Total Station Zoom30 Series

Precision Engineering

Positioning and Synchronization of Industrial Robots

Computer aided error analysis for a threedimensional precision surface mapping system

Leica NA700 Series Jobsite Tough, Clearly Precise

A U T O C O L L I M A T O R S

Provided by Xpert Survey Equipment Click Topcon GPT-8003A for Product Info and Updated Pricing GPT-8000A/GTS-810A SERIES AUTO TRACKING TOTAL STATION

Leica Geosystems Measure, align, level

ACTA TECHNICA CORVINIENSIS Bulletin of Engineering Tome X [2017] Fascicule 2 [April June] ISSN:

TERRESTRIAL LASER SYSTEM TESTING USING REFERENCE BODIES

VenScan LMS. Inline moisture measurement system for web-shaped materials (decorative papers, finish foils, overlays, underlays, laminates)

Keysight Technologies Transducer Systems. Leading the Future for Extreme Accuracy Positioning Applications

VELO Module Production - Final Module Metrology

Product information. Hi-Tech Electronics Pte Ltd

6 AXIS ROBOTIC ABRASIVEJET ADVANCEMENTS IN ACCURACY FOR QUALITY AND PRODUCTION

Industrial Measuring Technology from Carl Zeiss. Form, Contour and Surface. Measuring and Testing Precision from Carl Zeiss

Precimar. PLM and CiM Universal Length Measuring Machines

DRONACHARYA GROUP OF INSTITUTIONS, GREATER NOIDA Department of CIVIL Engineering Semester: III Branch: CIVIL Session: Subject: Surveying Lab

Alignment with the help of the alignment service

Transcription:

III/296 THE MOST FLEXIBLE INSTRUMENTATION FOR SURVEYING AND ALIGNMENT - A HIGH PRECISION TOTAL STATION CONTROLLED BY MODERN SOFTWARE Holger Wirth Metronom, Gesellschaft für Industrievermessung mbh, Mainz, Germany Gebhardt Moritz GSI, Gesellschaft für Schwerionenforschung mbh Darmstadt, Germany 1. INTRODUCTION For the surveying and alignment of the GSI beam-lines the Metronom company has developed the TASA Concept. The main aim of this development was the use of only one strategy for all accelerator alignments. The solution consists of the use of high-precision polar measurements combined with a complete assembly of new fiducial points. Furthermore, the installation of the new concept has prompted the GSI to modernize its surveying and alignment software. This paper aims to give an overview of the different sensors and the software package. The theory behind the concept is described in TASA - A New Standard Method for the Surveying and Alignment of beam-line Facilities at the GSI, published in the proceedings to this workshop. 2. TASA HARDWARE 2.1 The High-Precision Total Station Leica TC2002 The use of polar measurements is a very simple way of determining three-dimensional coordinates. It is frequently used in several geodetic applications and there have been many attempts to establish this method for industrial measurements (e.g. Total Stations, 3D-Lasertracker). The polar method has also been used for accelerator alignments, but all concepts have to take the often unsatisfying precision of the range-finder into account. LEICA offers the TC2002 as a high-precision total station in combination with reflective foils and software based on ECDS Modules as the PCMS System for industrial measurement applications. The instrument consists of a theodolite (T2000) and a concentrically integrated range-finder (D12002). In the general specifications for this total station, LEICA defines an accuracy for the distances of 1 mm + 1 ppm, but the distance sensor provides much more. LEICA is able to select tuned instruments during their fabrication and to deliver very powerful sensors with an accuracy of about ten times better than their specification. After the GSI had aquired a TC2002 in July of 1995, they commissioned the Technical University of Aachen with the calibration. The accuracy of distances between 2 m and 25 m was inspected by comparing the TC s readings to true distances (measured by a laser interferometer) at an interval of 25 cm. The test proves excellent tuning of the system. No cycle error was detectable and the only correction for the sensor/prism system was a offset. Figure 1 shows the residuals to a fitting curve. The standard deviation for the distances was calculated as 0.06 mm!

III/297 Fig. 1: TC2002 Versus Interferometer Distances To achieve the same accuracy on site as in the laboratory, it is necessary to heed the following points: Each sensor/prism constellation must be calibrated separately Variations in the atmosphere must be determined The alignment of the prism to the sensor must be within a certain limited range 2.2 Targets The indicated precision can not be obtained using reflex foils; upgraded triple prisms must be used. To simplify the prisms setup and to merge the reflectors with the centering method, they must be integrated to Taylor-Hobson spheres. This has been done by DESY and other institutes to enable measurements using the ME5000 laser range-finder. The prism is adjusted to the spherical center to eliminate the offset of the reflector. The advantage of this solution is the missing offset of the prism, but it is not possible to measure horizontal and vertical angles within the same aiming. For this a conventional Taylor-Hobson target with concentric circles (or other marks) is needed, adjusted to the exact midpoint of the sphere. To enable polar measurements on one shot, Metronom has developed a device based on a Taylor- Hobson sphere (made by Brunson) and a Leica standard prism. The installed prism is mounted on a xyzsupport to simplify the process of alignment to the spherical center. The prism provides concentrical circles on its entrance plane like the original Taylor-Hobson sphere. In contrast to the ME5000 target, the prism is adjusted without considering the offset value. The adjustment of the aiming mark to the midpoint of the sphere is more important, as an additional offset can be compensated automatically within the computation.

III/298 Fig. 2: Sideview of the Reflector Unit 2.3 Registration of the Atmosphere The atmosphere is determined using electronical sensors. Metronom has installed two sensors on a portable support to measure the temperatur, pressure and humidity of the air. The sensors are directly connected to the computer and they are queried with every distance measurement. Table 1: Atmosphere Sensors Used Sensor Temperature Air Pressure Humidity Name VAISALA HMP231 VAISALA PTB201A VAISALA PTB201A Precision 0.1 C 0.25 hpa 1 % 2.4 Inclinometers Two fiducial points (beam-in, beam-out) are mounted on every component. The components are aligned while setting the fiducial points to their nominal coordinates and by levelling, i.e. by tilt correction. The longitudinal tilt (pitch) can be evaluated from the heights of the fiducial points; the tilt rectangular to the beam (roll) must be measured separately. To improve the levelling system it is advisable to use eletronic sensors. While realising of the TASA Concept, Metronom established sensors made by Lucas Schaevitz (Switzerland) with a measuring range of ±1 (=17.45 mrad) and a precision of 0.03 mrad (depending on the absolut tilt). The advantages of the Schaevitz LSOC-inclinometers are their small size, robustness, wide working range and good precision. To determine possible twists in components the transversal tilts are measured twice. This is supported by the TASA consoles, which carry socket screws, to attach the inclinometers at equal and repeatable positions. To allow simultaneous measurements of both tilts, two sensors must be employed. In order to query the sensors electronically they are connected with the computer through a power supply.

III/299 2.5 The Sensor System To align components online it is necessary to connect all sensors to the computer. Fortunately, it is possible to address the sensors separately, so no special bus system is required. Optional it is possible to support a second screen, placed near by the component, to show the alignment staff the actual residuals and values of movement. 2.6 Computer Fig.3: Sensor Configuration No special hardware is required to operate the system. A modem PC, capable of running MS- Windows, is a standard in computing today. For TASA measurements, Metronom prefers the use of a handheld-computer like the new HUSKY-FC-486, as it is protected against humidity, dust and mechanical shocks. Furthermore, the FC-486 supports MS-Windows using PEN technology rather than a mouse or trackball. Fig.4: HUSKY FC-486

III/300 3. TASA SOFTWARE The TASA Concept is a new alignment method including hardware and software. During a complete alignment procedure a lot of data must be handled. Until the TASA Concept was realized no special software structure was used. The GSI decided to commission Metronom with the development of a new software package to come up with a solution specially designed for polar alignments based on the described hardware. The different programs should be user-friendly and able to be operated by unskilled employees, flexible and suitable for hand-in-hand work. To meet these requirements Metronom has developed programs which run under MS-Windows. The operating system allows event-driven programming and supports the design and the use of software with standard user-shells (general look and feel). Reference Network Determination Fig.5: TASA Sofware Structure Figure 5 shows the software-structure of 7 programs realised by the TASA Concept. The following descriptions give an overview of the features of the different programs.

III/301 INKLINO (Tilt Measurements) INKLINO is a program for tilt measurements with electronic inclinometers. It is possible to display online the readings of two sensors in a single or tracking mode simultaneously and to store the data into a file. The stored readings are corrected by systematic corrections (e.g. offsets, bias, etc.). For alignments a virtual analog needle can be displayed to improve the recognition of the tilt s value and sign. The tilt measurements can be analysed with the same program. For this purpose there is a module for data reduction and statistical evaluations (average value, median, standard deviation, etc.). CARRY (Transformation Program) The program CARRY has been specifically designed for the GSI. It is a transformation program for the calculation of nominal coordinates of new fiducial points. Input data is the tilt (roll) of a component (determined using INKLINO), a set of 3D coordinates for the old and new fiducial points in a horizontal coordinate system (determined using ECDS) and a set of nominal coordinates for the old fiducial points (calculated by the GSI). Output data is the nominal coordinates of the new fiducial points. PROLOG (Reference Network Measurements) This program is the most conventional one, as it supports all kinds of measurements using geodetic instrumentation. This program allows angle and distance measurements using Leica sensors (e.g. TC2002, T3000, E2, ME5000, etc.). It is possible to measure sets of angles and distances (including atmospheric parameters) and to store the readings in a file. The most important feature of PROLOG is a macro function for defining measuring macros. Normally the operator knows the exact numbers of stations and targets, so he can put them into the program before he starts working on site. The macro automatically reads the stored numbers and tells the operator which target he has to aim at. The recording of the readings can be released with a button on the instrument, so it is not necessary for the operator to interact directly with the computer. REWORK (Data Preprocessing) REWORK prepares the data, recorded with PROLOG, for the least square adjustment process. All kinds of corrections are calculated in order to eliminate systematic errors (e.g. evaluation of two-face angle measurements sets, calibration of distances, atmospherical corrections, vertical offsets, etc.). COLLATE (Approximation of Coordinates) The calculation of a least square solution needs proximate coordinates. COLLATE is able to evaluate proximate coordinates and to create a input file for the adjustment program PANDA.

III/302 HANDLE (Database Management) The database management program HANDLE is the heart of the TASA software package, as it is the central data store. The user is able to create all files necessary for the operation of other TASA programs using import and export functions. The data is stored in a relational database, so the operator has the advantages of sorting, selecting or defining special data queries to create dynasets. HANDLE supports a special user-shell to improve the data access and to allow operators with no database skills to work with a relational database without any knowledge of the internal administration procedures. ALIGN (Online Alignment) The program ALIGN combines the features of a data acquisition, preprocessing and evaluation program. This module supports functions for the tacheometric online alignment of components using a TC2002, electronic atmosphere and tilt sensors. The evaluated actual coordinates of the fiducial points of the component (beam-in, beam-out) are compared with their nominal values. Based on the coordinate differences and a set of coordinates for the alignment supports of the component, the program calculates shifts for the support screws. The program displays these values in a table, which can be transmitted to a second screen placed close by the alignment staff. The following screen shots give an overview of the design of the software. The use of standard control elements (e.g. menue structures, buttons, function keys, option boxes, list boxes, online help, etc.) enables the user to operate the programs without participating in a lengthy training course (intuitive use). Fig. 6: Screen shot of the Data Capture Module of ALIGN

III/303 Fig. 6: Screen shot of the Alignment Evaluation Module of ALIGN 4. CONCLUSION The GSI has no surveying staff of its own. Surveying and alignment tasks are carried out by service companies. With the TASA software the GSI is not dependent on special experts and individual solutions. For the operating of the programs the user must be skilled in geodetic methods, but not necessarily in accelerator alignment methods. The realisation of the TASA Concept for all of the GSI accelerators is not yet finished. The first accelerator (ESR) is momentarily being prepared for a realignment at the end of 1995. Metronom and the GSI intend developing the entire system to a commercial product as an alignment method for small and midsize accelerator facilities. REFERENCES [1] SCHMADEL, I. : Survey System for the SIS, SCIENTIFIC REPORT 1986, S.339 [2] SCHMADEL, I. : Geodetic Survey and Component Alignment of the Experimental Storage Cooler Ring ESR, Proc. 2nd. Intern. Workshop Accelerator Alignment (1990) S. 11-25. [3] PALUSZEK, H., SCHMADEL, I., WIRTH H.: TASA - A New Surveying and Alignment Concept, SCIENTIFIC REPORT 1992, S.444 [4] SCHWARZ, W. : Die Justierung von Teilchenbeschleunigern, Allg. Verm.-Nachr., Karlsruhe 101 (1990) s. 2-18