Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information

Similar documents
Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Signal conditioning instruments VEGASCAN 693. Product Information

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

Safety instructions VEGATOR 121, 122

Operating Instructions

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure

Safety instructions Overvoltage protection B81-35

VEGAMET 381 VEGAMET 624 VEGAMET 625

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Interface and Supply module. IPC 3x0i / PSC 3x0i

Product information Ultrasonic

Isolating repeater IRU 420

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

PI-EX-ME-2NAM/COC-24VDC

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

PHOENIX CONTACT - 12/2007

5 Fieldbus Technology

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

PI-EX-ME-2NAM/COC-120VAC

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

Intrinsically Safe Barriers

English. Operating Manual. Universal Isolating Amplifier TV125M / ST125M. Save for later reference. Companies / Brands of GHM

PHOENIX CONTACT - 02/2008

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

PROFIBUS-PA Positioner Type 3785

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

MACX MCR-EX-SD LP(-SP)

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

Supplementary instructions. Plug connector Harting HAN 8D. for continuously measuring sensors. Document ID: 30376

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Operating Instructions VEGAMET 381

Trendmaster* Galvanic Isolator

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Operating Instructions VEGAMET 391. Signal conditioning and display instrument for level sensors ma/hart. Document ID: 36032

PHOENIX CONTACT - 05/2007

Float Switches with Permanent Magnet For Vertical Installation Model RSM

SIMATIC Distributed I/O Product information for the ET 200iSP Operating Instructions (A5E ) 01/2010

Intrinsically Safe Explosion Proof Barriers

Product information. Radar. Level measurement in bulk solids VEGAPULS 67 VEGAPULS SR 68 VEGAPULS 68 VEGAPULS 69. Document ID: 29427

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

CPU module for zone 2 Series 9442/35

Operating Instructions VEGAMET 391. Signal conditioning and display instrument for level sensors ma/hart. Document ID: 36032

Float Switches with Permanent Magnet For Horizontal Installation Model HIF

Series 3730 Electropneumatic Positioner Type

Operating Instructions

Supplementary instructions. VEGADIS adapter. For connection of an external display and adjustment unit or a slave sensor. Document ID: 45250

VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing.

Product information. Hydrostatic. Submersible pressure transmitter VEGABAR 86 VEGABAR 87 VEGAWELL 52. Document ID: 45079

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Operating Instructions SU 600 Ex

Operating Instruction

MANUAL Surge Protectors

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

Sense it! Connect it! Bus it! Solve it! REMOTE I/O excom

Process display RIA 251. Digital loop powered display for ma current loops. Application areas. Plant and machine construction.

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Inductive sensor BI5-EM18-Y1X-H1141

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner

MACX MCR-EX-SL-RPSSI-I(-SP)

FEATURES. Nominal Output Voltage and Current

Intrinsically safe batch controller Batching Master 110i

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Zener Barriers Bulletin 937Z

System Components Surge Arrester HAW 261 and HAW 262

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

MACX MCR-EX-SL-NAM-R(-SP)

MACX MCR-EX-SL-NAM-2RO(-SP)

Series 3730 Electropneumatic Positioner Type with HART communication and pressure sensors

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

MODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable)

How to calculate an Intrinsically Safe loop approval.

Inductive sensor BI1.5-EG08-Y1-H1341

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

VISY. Technical Documentation. VISY-Command (VI-4) Version: 6 Edition: Art. no.:

Operating Instructions. VEGA DataViewer. Software for archive, administration and display of DTM data. Document ID: 51547

Operating instructions

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

Level measurement. Applications. Special features. Description

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Transcription:

Separating and protective instruments Separating and protective instruments VEGATRENN 149AEx Separator type KFDO Barrier type 9001 Product Information

Content Content 1 Product description.......................................................................... 3 2 Type overview.............................................................................. 5 3 Mounting instructions......................................................................... 6 4 Connecting to power supply 4.1 Preparing the connection................................................................... 7 4.2 Wiring plan............................................................................. 7 5 Operation 5.1 Adjustment of the separators................................................................ 9 5.2 Adjustment of the sensor................................................................... 9 6 Technical data............................................................................. 10 7 Dimensions................................................................................ 13 8 Product code.............................................................................. 14 Take note of safety instructions for Ex applications Please note the Ex specific safety information which you will find on our homepage www.vega.com\services\downloads and which come with the appropriate instrument with Ex approval. In hazardous areas you should take note of the appropriate regulations, conformity and type approval certificates of the sensors and power supply units. Each with Ex approval is an associated, intrinsically safe instrument and must not be installed in hazardous areas. 2 Separating and protective instruments Separating and protective instruments

Product description 1 Product description Functional principle Separators separate intrinsically safe circuits from non-intrinsically safe circuits. In general, a difference is made between galvanic separation by: l Ex separators (with external energy) l Separators (without external energy) Limitation of the electrical variables by: l Safety barriers Ex separator The Ex separator is used as intrinsically safe power supply for Ex approved 4 20 ma/hart sensors. Through the auxiliary energy the sensor can be provided with more power. The instrument ensures a galvanic separation between sensor circuit and processing circuit and hence between Ex and non-ex areas. The load-independent 4 20 ma current is transmitted linearly to the output. The sockets in the front enable HART communication with the sensor via VEGACONNECT 3. The necessary communication resistance (R = 250 Ω) is already integrated in. Fig. 2: The safety barrier type 9001 is used for intrinsically safe measuring current transmissionin Ex Zone 1 without galvanic separation. It is hence suitable for connection of an indicating instrument to the non-intrinsically safe 4 20 ma output of a signal conditioning instrument. Safety barriers are also called zener barriers. Product properties: l Universal use for all 4 20 ma indicating instruments l Loop-powered, i.e. no additional power supply required Product properties: l Universal for all passive 4 20 ma/hart sensors l HART transmission to the output side l Sockets in the front for connection of VEGACONNECT l SIL 2 qualified Fig. 3: 1.1 Application examples Ex separator Fig. 1: Ex separator 1 2 3 4 4... 20 ma SPS Separator type KFD0 The separator KFD0-CS-Ex1.51P is used for intrinsically safe power supply and signal transmission of Ex approved 4 20 ma sensors. It is loop-powered without external energy. The instrument ensures a galvanic separation between sensor circuit and processing circuit and hence between Ex and non-ex areas. The load-independent 4 20 ma current is transmitted linearly to the output. However, a HART signal is not transmitted. Product properties: l Universal for all passive 4 20 ma sensors l Also in conjunction with signal conditioning instruments without own Ex approval l Loop-powered, i.e. no additional power supply required l Mounting of the separator in Ex zone 2 permitted 20... 253 V AC/DC Fig. 4: Intrinsically safe supply of an ultrasonic sensor via, indicationof the measured value or transmissionto a PLC/ controlsystem input card (4 20 ma) 1 Sensor 2 3 Indication 4 PLC/Control system/processing system Separating and protective instruments Separating and protective instruments 3

Product description 3 1 4... 20 ma 2 Fig. 5: Connection of a guided microwave sensor to a VEGALOG 571 processing system via the separator type KFD0 1 Sensor 2 3 VEGALOG 571 processing system 4 2 1 3 Fig. 6: Connection of an indicating instrument to a VEGAMET signal conditioning instrument via the safety barrier type 9001 1 Sensor 2 3 VEGAMET signal conditioning instrument 4 Indication 4 Separating and protective instruments Separating and protective instruments

Type overview 2 Type overview Ex separator Separator Type KFD0-CS-Ex1.51P Safety barrier Type 9001 Applications: Galvanically separated voltage supplyofex approved4 20mA sensors Galvanic separation of intrinsically and non-intrinsically safe 4 20 ma circuits HART signal transmission: Yes No No Intrinsically safe measuring current transmission in Ex zone 1 Sensors: 4 20 ma passive 4 20 ma passive 4 20 ma indication Mounting: Carrier rail Carrier rail Carrier rail Ignition protection label: II (1)G D [EEx ia] IIC II (1)G D [EEx ia] IIC II (1/2)G [EEx ia/ib] IIC/IIB Separating and protective instruments Separating and protective instruments 5

Mounting instructions 3 Mounting instructions Installation All separators described in this product information manual are mounted on carrier rail 35 x 7.5 according to EN 50022. 6 Separating and protective instruments Separating and protective instruments

Connecting to power supply 4 Connecting to power supply 4.1 Preparing the connection Note safety instructions Always keep in mind the following safety instructions: l Connect only in the complete absence of line voltage l If overvoltage surges are expected, overvoltage arresters should be installed Tip: We recommend VEGA overvoltage arresters B61-300 (external energy) and B62-36G (sensor supply). 4.2 Wiring plan Ex separator 1 I+ I- Take note of safety instructions for Ex applications In hazardous areas you should take note of the appropriate regulations, conformity and type approval certificates of the sensors and power supply units. 4 Select power supply The voltage supply for the Ex separator mustbeintherangeof20 250VAC,50/60Hzor20 250VDC. 0+H 0+ 0- L/+ N/- Selecting connection cable For power supply of, an approved installation cable with PE conductor is necessary. The sensor or the signal conditioning instrument are connected with standard two-wire cable to the separator. If strong electromagnetic interference is expected, screened cable should be used. Cable screening and grounding If screened cable is used, connect the cable screen on both ends to ground potential. In the sensor, the screen must be connected directly to the internal ground terminal. The ground terminal on the outside of the housing must be connected to the potential equalisation. If potential equalisation currents are expected, the screen connection on the separator or signal processing instrument must be made via a ceramic capacitor (e. g. 1 nf, 1500 V). The low frequency potential equalisation currents are thus suppressed, but the protective effect against high frequency interference signals remains. 0+H 0+ 0- L/+ N/- Fig. 7: Terminal assignment 1 Sensor circuit 2 Processing circuit 3 Power supply 4 HART communication sockets 2 3 Select connection cable for Ex applications Take note of the corresponding installation regulations for Ex applications. In particular, make sure that no potential equalisation currents flow over the cable screen. In case of grounding on both sides this can be achieved by the use of a capacitor or a separate potential equalisation. Separating and protective instruments Separating and protective instruments 7

Connecting to power supply 2- J 1+ 1 4 3 + - + - 1 - - 1 2 160 U 12-11+ 2 9001/01-086/150/10 3 4 Fig. 8: Terminal assignment separator type KFD0-CS-Ex1.51P 1 Sensor circuit 2 Processing circuit + - 2 Fig. 9: Terminal assignment safety barrier type 9001 1 Input circuit (non-intrinsically safe) 2 Output circuit (intrinsically safe) 8 Separating and protective instruments Separating and protective instruments

Operation 5 Operation 5.1 Adjustment of the separators After installation, the separators described in this product information manual are immediately ready for operation. An adjustment is not required. 5.2 Adjustment of the sensor A VEGA sensor powered via the can be also adjusted via the. You will need a Windows-PC with the configuration software PACTware and a suitable instrument driver (DTM) according to the FDT standard. For connection, the VEGACONNECT 3 interface converter with corresponding cable is required. 1 2 3 6 4 4... 20 ma SPS 5 PACTware TM/ VEGA-DTM VEGACONNECT 3 Fig. 10: Adjustment of the sensor via VEGACONNECT 3 and VEGATRENN 149AEx 1 Sensor 2 3 Indication 4 HART adapter cable for VEGACONNECT 3 5 RS232 connection 6 PLC/Control system/processing system Necessary components: l Sensor l PC with PACTware and suitable VEGA DTM l VEGACONNECT 3 with HART adapter cable l Separating and protective instruments Separating and protective instruments 9

Technical data 6 Technical data General data Series Instrument for mounting on carrier rail 35 x 7.5 according to EN 50022 Dimensions Housing material Weight approx. W = 22.5 mm (0.89 in), H = 112 mm (4.41 in), D = 110 mm (4.33 in) Polycarbonate ABS, flammability class UL94V-0 150 g (0.44 lbs) Series Instrument for mounting on carrier rail 35 x 7.5 according to EN 50022 Dimensions Weight approx. W = 20 mm (0.79 in), H = 115 mm (4.53 in), D = 107 mm (4.21 in) 100 g (0.22 lbs) Series Instrument for mounting on carrier rail 35 x 7.5 according to EN 50022 Dimensions Housing material Weight approx. B = 12.2 mm (0.48 in), H = 71.5 mm (2.81 in), T = 102 mm (4.01 in) Polyamide 6 GF 115 g (0.44 lbs) Sensor circuit Range 4 20 ma Supply voltage 16.7 V ±0.2 V (at 20 ma) Open-circuit voltage 26 V ±5 % Shortcircuit current 32 ma Inner resistance 328 Ω intrinsically safe (max. values in case of failure) Open-circuit voltage U o 27.3 V Shortcircuit current I o 84.1 ma Power P o 576 mw Capacitances - EEx ia IIC C o 86 nf - EEx ia IIB C o 683 nf - EEx ia IIA C o 683 nf Inductances - EEx ia IIC L o 5.5 mh - EEx ia IIB L o 20 mh - EEx ia IIA L o 20 mh Range 4 20 ma Output voltage - at 4 V < supply voltage < 24 V supply voltage - (0.4 x current in ma)v - 1 V - with supply voltage 24 V 23 V - (0.4 x current in ma)v Shortcircuit current 65 ma intrinsically safe (max. values in case of failure) Open-circuit voltage U o 25 V Shortcircuit current I o 93 ma Power P o 585 mw Capacitances - EEx ia IIC C o 2.41µF - EEx ia IIB C o 16.8µF - EEx ia IIA C o 75µF Inductances - EEx ia IIC L o 4 mh - EEx ia IIB L o 17 mh - EEx ia IIA L o 32 mh 10 Separating and protective instruments Separating and protective instruments

Technical data Input circuit Nominal voltage 6 V DC Zener voltage 8.6 V Leakage current against ground with U Nom 1µA min. longitudinal resistance 64 Ω max. longitudinal resistance 73 Ω Processing/Output circuit Open-circuit voltage 24 V ±10 % Max. load - without communication resistance 700 Ω - with communication resistance 450 Ω Voltage 4 35 V DC Current 40 ma Power loss - with 40 ma and voltage < 24 V 700 mw - with 40 ma and voltage 24 V 1.2 W Indication circuit Shortcircuit current 150 ma Capacitances - EEx ia IIC C o 6.2µF - EEx ia IIB C o 55µF Inductances - EEx ia IIC L o 1.3 mh - EEx ia IIB L o 7 mh Ambient conditions Ambient temperature Storage and transport temperature Ambient temperature Ambient temperature Storage and transport temperature -20 +50 C (-4 +122 F) -40 +70 C (-40 +158 F) -20 +60 C (-4 +140 F) -20 +60 C (-4 +140 F) -40 +75 C (-40 +167 F) Voltage supply Supply voltage Max. power consumption 20 253 V AC, 50/60 Hz 20 253 V DC 2.4 W Electrical protective measures Protection IP 20 Separating and protective instruments Separating and protective instruments 11

Technical data Separator type KFD0 Protection IP 20 Protection - Terminal bearing IP 20 - Housing IP 40 Electrical separating measures Galvanic separation Galvanic separation Output circuit of all other circuits Output circuit to input circuit Approvals 1) ATEX ATEX ATEX II (1)G D [EEx ia] IIC II (1)G D [EEx ia] IIC II (1/2)G [EEx ia/ib] IIC/IIB Environmental instructions VEGA environment management system certified according to DIN EN ISO 14001 You can find detailed information under www.vega.com. 1) Deviating data in Ex applications: see separate safety instructions. 12 Separating and protective instruments Separating and protective instruments

on CONNECT 149AEx Dimensions 7 Dimensions 22,5mm (57/64") 112mm (4 13/32") 96mm (3 25/32") 110mm (4 21/64") Fig. 11: Dimensions 20mm (25/32") 115mm (4 17/32") 107mm (4 7/32") Fig. 12: Dimensions separator type KFD0-CS-Ex1.51P 12,2 mm (31/64") 71,5mm (2 25/64") 160 160 102mm (4 1/64") 9001/01-086-150 101 3 4 Fig. 13: Dimensions safety barrier type 9001 Separating and protective instruments Separating and protective instruments 13

Product code 8 Product code Approval EX.X ATEX II (1) G D [EEx ia] IIC TRENN149A KFD0-CS-EX1.51P TRENN9001. 14 Separating and protective instruments Separating and protective instruments

Separating and protective instruments Separating and protective instruments 15

VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-Mail: info@de.vega.com www.vega.com You can find at www.vega.com downloads of the following l operating instructions manuals l menu schematics l software l certificates l approvals and much, much more Subject to change without prior notice