Reed sensor For bypass level indicators Model BLR

Similar documents
Level sensor with reed measuring chain Model FLR, for the process industry

Threaded resistance thermometer Miniature design Model TR10-D

Resistance thermometer With spring-loaded tip Model TR55

Threaded thermocouple Miniature design Model TC10-D

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Float switch For the process industry, lateral installation with external chamber Model ELS

Hand-held thermometer, precision version Model CTH6500 Model CTH65I0, Ex version

Magnetic float switch For vertical installation Model FLS

Gas-actuated thermometer Stainless steel version Model 73

Float Switches with Permanent Magnet For Horizontal Installation Model HIF

Float switch For the process industry

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Hand-held thermometer, industrial version Model CTH6300 Model CTH63I0, Ex version

Resistance thermometer For additional thermowell Model TR10-B

Threaded resistance thermometer With protection tube Model TR10-C

Threaded resistance thermometer Model TR10-C, with protection tube

Float switch For industrial applications Model RLS-1000

Bayonet resistance thermometer Model TR53

Bourdon tube pressure gauge with electrical output signal Stainless steel, safety version, NS 63 Model PGT23.063

Differential pressure sensor For ventilation and air-conditioning Model A2G-50

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Level sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H

Temperature dry-well calibrator Models CTD , CTD

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Thermocouples Model TC200, for Additional Thermowell

Micro calibration bath Models CTB , CTB

Temperature dry-well calibrator Models CTD9100-COOL, CTD , CTD , CTD

Temperature dry-well calibrator Models CTD9100-COOL, CTD , CTD , CTD

Level sensor for monitoring the level of liquid media

Programming unit VIATOR HART modems Model PU-H

Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52

Electronic pressure switch with display For sanitary applications Model PSA-31

Electronic pressure switch with display For sanitary applications Model PSA-31

Level measurement. Applications. Special features. Description

Terminal Boxes Series 8118

Grounding Monitoring Device Series 8485

Electronic pressure switch with display For sanitary applications Model PSA-31

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM ET-436-TX

Electronic pressure switch with display Model PSD-4

Grounding Monitoring Device Series 8485

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS ET-306-FX

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX

Safety instructions Overvoltage protection B81-35

Load Disconnect Switches and Motor Switches

Pneumatic Control/Feedback

Hand-held thermometer Model CTH6200

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE PM MT-336-FX

CalibratorUnit Models CPU6000-W, CPU6000-S, CPU6000-M

Operating and monitoring systems Thin Client SERIES 500 Device platform EAGLE PM ET-556-TX

Hand-held thermometer Model CTH7000

Pneumatic Control/Feedback

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS MT-316-TX

Standard reference resistor Model CER6000

Multi-functional precision thermometer CTR3000

Precision digital pressure gauge Model CPG1500

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Level gauges Series LS Level indicator, switch and transmitter for liquids

ExCos-P Pressure sensor 20 Pa Pa

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

USB pressure transmitter model CPT2500 with model CPA2500 USB adapter and USBsoft2500 software

Dräger Polytron 8200 Stationary gas detector (CatEx)

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

USB pressure sensor With USB adapter and software Model CPT2500

Portable low-pressure controller Model CPC2000

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

Precision digital pressure gauge Model CPG1500

Pneumatic Control/Feedback

Precision thermometer Model CTR2000

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

Tubular Light Fitting with LED Series 6036

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

Precision thermometer Model CTR5000

Supplementary Components WirelessHART products

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Flow Measurement SITRANS F C

Micro Limit Switch Series 8064

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

Ground Monitoring Device Series 8485

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Precision digital gas density indicator Model GDI-100-D

IHP24. Intelligent Hydraulic Positioner D HP- PL

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Hand-held thermometer Model CTH7000

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Adapter system for measuring instruments with G1 hygienic connection Model process adapter

DR7100 SERIES Supplementary instructions

Operating pressure (bar) kv factor (m 3 /h) *3)

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

ProcessCalibrator Model CPH6000

DC resistance thermometry bridge Model CTR6000

Installation & Operation Manual

Product information Ultrasonic

Transcription:

Level measurement Reed sensor For bypass level indicators Model BLR WIKA data sheet LM 10.04 for further approvals see page 3 Applications Sensor for the continuous level measurement of liquids in bypass level indicators Chemical, petrochemical industry, natural gas, offshore, shipbuilding, machine building, power generating equipment, power plants Process water and drinking water treatment, food and beverage industry, pharmaceutical industry Special features Installation of head-mounted transmitters in the connection housing possible Wide variety of different electrical connections, process connections, materials and contact separations Programmable and configurable head-mounted transmitters for 4... 20 ma, HART, PROFIBUS PA or FOUNDATION Fieldbus field signals Explosion-protected versions Temperature ranges from -100 +350 C Description The model BLR reed sensors are used for continuous monitoring and recording of the liquid level in connection with transmitters. They work on the float principle with magnetic transmission (permanent magnet, reed switch and resistance measuring chain) in a 3-wire potentiometer circuit. A magnetic system built into the float actuates reed contacts, through the walls of the bypass chamber and of the sensor tube, in a resistance measuring chain (potentiometer). The measurement voltage generated by this is proportional to the fill level. Reed sensor, model BLR-S The resistance measuring chain is made up from reed contacts and resistors soldered onto a PCB. Depending on requirements and design several different contact separations from 5 to 18 mm are available. For selecting the optimum sensor (sensor model, connection housing, electrical connection, sensor tube (material and total length), contact separation, head-mounted transmitter, measuring range, approval) we offer application-related technical advice. Page 1 of 7

Internal circuit diagram of the reed sensors brown blue/grey black Legend Resistance Reed contact Page 2 of 7

Approvals Logo Description Country EU declaration of conformity EMC directive EN 61326 emission (group 1, class B) and interference immunity (industrial application) RoHS directive ATEX directive (option) European Union - Ex i II 2G Ex ia IIC T4... T6 Gb or No. KEMA 01 ATEX 1052 X II 2G Ex ib IIC T4... T6 Gb or II 2D Ex ib IIIC T80 C Db - Ex d II 2G Ex d IIC T6 Gb or II 2D Ex tb IIIC T80 C Db No. TÜV 13 ATEX 7399 X IECEx (option) - Ex d Zone 1/2-40 C Ta +55 C Ex d IIC T6 Ex td A21 IP65 T80 C EAC EMC directive No. TC N RU Д-DE.A301.B.00820 No. RU C-DE.ГБ08.B.01489 GOST No. 19359 KazInMetr No. 13947 BelGIM No. 9711 UkrSEPRO No. UA-MI/2-4988-2015 Uzstandard No. 02.6649 - PESO No. P331149/1 DNV GL Ships, shipbuilding No. TAA00000M2 No. IECEx TUR 09.0002X International Eurasian Economic Community Russia Kazakhstan Belarus Ukraine Uzbekistan India International Approvals and certificates, see website Page 3 of 7

Reed sensor, standard version with connection housing Models BLR-SA, BLR-SB Guide tube and float made of 1.4571 stainless steel Aluminium and polyester connection housing Ø 14 Stainless steel connection housing 100 % M=... 50 113 Stainless steel connection housing with digital indicator (option) 0 % 22.5 80 100 ~92 75 125 Electrical connection Guide tube diameter Temperature range Standard version High-temperature version Low-temperature version Standard version with Mikroterm High-temperature version with Mikroterm Resolution Overall resistance of the measuring chain Model BLR-SA Option: Polypropylene, polyester, stainless steel 14 mm -50... +100 C -50... +200 C -100... +100 C -50... +250 C -50... +350 C 2.7 mm / 5.5 mm / 7.5 mm / 9 mm (depending on contact separation) Depending on length and separation Model BLR-SB with head-mounted transmitter Option: Polypropylene, polyester, stainless steel Head-mounted transmitter External transmitter Head-mounted transmitter, see page 7 Output 3-wire potentiometer 4... 20 ma Permissible power supply < AC 50 V, < DC 75 V See the data sheet of the head-mounted transmitter used Ingress protection up to IP66 or IP68 per IEC/EN 60529 (depending on version) Page 4 of 7

Reed sensor, explosion-protected version Ex i, intrinsically safe Models BLR-SAI, BLR-SBI (MG...) KEMA 01 ATEX 1052 X (II 2G Ex ia IIC T4... T6 Gb, II 2D Ex ib IIC T4... T6 Gb or II 2 D Ex ib IIIC T80 C Db) Guide tube and float made of 1.4571 stainless steel Aluminium and polyester connection housing Stainless steel connection housing Ø 14 100 % M=... 50 113 Stainless steel connection housing with digital indicator (option) 0 % 22.5 80 100 ~92 75 125 Electrical connection Guide tube diameter Maximum permissible surface temperature at the sensor tube Resolution Overall resistance of the measuring chain Control circuit Model BLR-SAI (MG...) Option: Stainless steel 14 mm T4: +100 C T5: +65 C T6: +50 C 2.7 mm / 5.5 mm / 7.5 mm / 9 mm (depending on contact separation) 3.2... 50 kω Model BLR-SBI (MG...) with head-mounted transmitter Option: Stainless steel Ignition protection type Ex ia IIC (only for connection to a certified intrinsically safe control circuit) and ignition protection type intrinsically safe Ex ib IIC Head-mounted transmitter External transmitter Head-mounted transmitter, see page 7 Output 3-wire potentiometer 4... 20 ma Permissible power supply < AC 50 V, < DC 75 V See the data sheet of the head-mounted transmitter used Ingress protection up to IP66 or IP68 per IEC/EN 60529 (depending on version) Page 5 of 7

Reed sensor, explosion-protected version Ex d, flameproof enclosure Models BLR-SAD, BLR-SBD (AVK-ADF) TÜV 13 ATEX 7399 X (II 2G Ex d IIC T6 Gb / II 2 D Ex tb IIIC T80 C Db) IECEx TUR 09.0002X (-40 C T a +55 C Ex d IIC T6 Ex td A21 IP65 T80 C) Guide tube and float made of 1.4571 stainless steel Ø 14 110 75 L=... 170 87 Electrical connection Guide tube diameter Maximum permissible surface temperature at the sensor tube Resolution Overall resistance of the measuring chain Model BLR-SAD (AVK-ADF) Connection housing: Aluminium 170 x 151 x 87 mm Option: Stainless steel 14 mm T4: +100 C T5: +65 C T6: +50 C 2.7 mm / 5.5 mm / 7.5 mm / 9 mm (depending on contact separation) Depending on length and separation Model BLR-SBD (AVK-ADF) Connection housing: Aluminium 170 x 151 x 87 mm with head-mounted transmitter Head-mounted transmitter External transmitter Head-mounted transmitter, see page 7 Output 3-wire potentiometer 4... 20 ma Permissible power supply < AC 50 V, < DC 75 V See the data sheet of the head-mounted transmitter used Ingress protection up to IP66 or IP68 per IEC/EN 60529 (depending on version) Page 6 of 7

Head-mounted transmitter Model T15 Model T32 Model T53 Model TLEH Model 4... 20 ma HART PROFIBUS PA FOUNDATION Fieldbus Ex i Display Order no. TE x x 014832 TS x 005894 T32E x x x 025216 T32S x x 114795 T53F x x 025727 T53P x x 034422 TLH x x x 019989 TLEH x x x x 021104 T15 x x 122955 122954 Ordering information Model / Connection housing / Electrical connection / Sensor tube (material and total length) / Contact separation, head-mounted transmitter / Measuring range / Approval / Options To order the described product the order number (if available) is sufficient. 08/2014 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. 07/2017 EN Page 7 of 7 WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de