Installation Instructions for the Blue Dot Lock Door Controller

Similar documents
Instruction Manual. Balanced Audio Upgrade Installation. iport IW-21/IW-22 Upgrade Kits. Balanced Audio Upgrade Kit. (iport IW-21)

Control Mount Instruction Manual CM-IW200

Delta Unifence Kit Installation Instructions

Delta Unifence Kit Installation Instructions

RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS

Owner s s Manual. G5 SATA Double Drive Internal Mounting Kit. Apple Macintosh G5. Add 2 SATA drives to the G5

Instruction Sheet ICLS-COOL TM. Quiet-Cool Series Closet Cooler ICLS-COOL1 ICLS-COOL2

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs)

Shop Fox Fence Kit Installation Instructions:

INSTRUCTION MANUAL. Sensoray Model 720RB/DIN. Relay I/O Board (Rev A) October 12, 2001

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

SpeedVault Model SV 500 User Manual

232iLM Keypad Installation and Programming Instructions

PMDX-170 Slotted Optical Sensor

MPP200 User s Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

PREFACE. Thank you for choosing Zen Space Desks. We hope your desk helps you find your zen when being used. Zen Space Desks Team

Paoloni Rip Kit Installation Instructions

Biesemeyer Fence Kit Installation Instructions:

WARRANTY & LIMITATION OF LIABILITY

Canopy Surge Suppressor

WARRANTY & LIMITATION OF LIABILITY

Wireless Doorphone Intercom

Paoloni Rip Kit Installation Instructions

Owner s s Manual. SATA A II LCD Hot-Swap Systems. Macintosh, Windows, Linux EXTERNAL SYSTEM INTERNAL 5.25 SYSTEM DUAL EXTERNAL SYSTEM

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

An ISO-9001 Certified Company

Proliphix EPA-60 Installation Guide

212iL Rev. 1.1

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Holz-Her Sliding Table Saw Kit Installation Instructions: For 1243 Rip Kits

AC4G-D User s Manual

PWRguard PLUS Spring City Drive Waukesha, WI

AirPro Surveyor 2 Manual

DP-222Q Color Video Door Phone Manual

DOLXFD1000B. Waterproof Access Control/Reader

DP-222Q Color Video Door Phone Manual

INSTRUCTION MANUAL. IN-WALL DOCKING SYSTEM for ipod INTRODUCTION BOX CONTENTS. iport REAR-PANEL CONNECTIONS. Figure 1: iport Connections

Relay Board. User Manual. 1.0, Oct 2013

DataPort 350 & 525 USB 2.0 and FireWire Enclosure User s Guide (800)

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

Smart-Box Series. Electronic Lockbox User Manual. Model: 7000,

DP-234Q (NTSC) DP-734Q (PAL) Hands-Free Video Door Phone Manual

What s in the box. SUP paddle sensor. Paddle sensor mounting track. Charger. USB cable. In your Motionize SUP kit you will find:

OP8/16 Optoisolated Digital Input Board User's Manual

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

Owner s s Manual. SATA A II Aluminum Hot-Swap Systems. Macintosh, Windows, Linux 2 BAY 4 BAY 4 BAY. Rack 8 BAY. Rack

Instruction and Operation Manual. CRMS Contact Resistance Measurement System. Model Number Caution!

INSTALLATION INSTRUCTIONS

LA600WH WIRED / WIRELESS DOOR CHIME

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

BrassHat Announcer Message & Sound Player Model No. BH-21A

TB-100 ControLynx Terminal Block

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

F²MC-8L FAMILY MB89201 SERIES FLASH PROGRAMMING 8-BIT MICROCONTROLLER APPLICATION NOTE. Fujitsu Microelectronics Europe Application Note

ATMOX Power Supply ATMOX AC Adapter with Plugs. Wiring Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide

Dual Component Video Wall Plate 6-RCA AT80COMP6

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01

OPERATIONS MANUAL PCM-I/O48

USER MANUAL. TS Series (Model 52X) Terminal Strip Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Sensoray Model 627 CompactPCI to PCI Adapter

icp installation guide

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

SD1306. Speed Dome IP Camera. Quick User Guide

Wall. No opening (Example: LA-030-W)

OM bit GPIO Daughter Card User Manual

MUTING VOLUME CONTROL CONNECTION TERMINAL

Plus-X AC-8. User Guide

DP4 DOOR PHONE. For Technical Assistance Please Phone: (07)

MTX-A Temperature Gauge User Manual

CLICK HERE FOR ACCESS

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

PRODUCT CONTENTS... 3 II. REQUIRED MATERIALS... 3 III. OVERVIEW... 3 IV. BENCH LAYOUT...

P O W E R S U P P L Y M A N U A L

Download the Ring app

MPP1700 User s Manual

Demo Kit Quick Start Guide

USER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem

DP2. Door Phone. For Technical Assistance call the Manufacturers direct ph AM - 5PM West Coast Pacific Time

PSA200 User s Manual

eforce 150 Keyless Entry Owner s manual & User s guide For Model 3090

INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE

USB-A to Serial Cable

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

PMDX-105 Quad Isolator Board

F2MC MB90385 series Evaluation Board Documentation. Revision Date Comment V New document

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

ULTRATRAK RM4000 QUICK START GUIDE. Version 1.3

Analog Interface Unit Operation Manual

CF15118 CompactFlash Carrier utilitymodules User s Manual

Automated Tuner System Power Distribution Hub

Transcription:

TM Installation Instructions for the Blue Dot Lock Door Controller Ordering U-7001-001 U-7001-002 Controller with 3 second on time (standard access control) Controller with 0.5 second on time (simulated push button) Kit Contents Single-gang Retrofit Outlet Box Controller Board Blue Dot Receptor Additional Parts Needed RTV or silicon caulk Utility box face place Doorbell or Thermostat wire (18 AWG twisted pair) Tools Required for Installation Pencil Dry Wall Saw Phillips Screwdriver Small Standard Screwdriver Speaker (Beeper) Pink Foam pad Instructions Momentary push button switch (optional) 12V 24V AC/DC power supply (optional) ibutton Keys (Black) (optional) Sync ibutton (Blue) (optional) Power Drill 1 & ½ Drill Bits Utility Knife Tape Measure Page 1 of 13

SPECIFICATIONS Power Supplies Door / Gate and Garage Door Installation: Always use a constant power supply as the power source of the controller. This voltage can be from 12V to 24V (AC or DC) transformer or regulated power supply. Controller/ Blue Dot Distance The distance between the Blue Dot Receptor and the controller board can be no more than 10 ft. Environmental Conditions The Blue Dot Gate controller will operate from 4 F to +185 F ( 20 C to +85 C). Page 2 of 13

INSTALLATION Mounting Considerations In order to pick the best location for installing the controller board and the Blue Dot Receptor, one should take into account ease of use and the distance between the controller and the receptor. The optimum location for the receptor is near the door at a height of 48 from the ground, more or less as the user requires. The Blue Dot should be securely mounted on a firm vertical surface such as a doorframe or fence post. For security reasons, the Blue Dot and the Controller board should not be installed in the same electrical box. Choose a location on the secure side of the fence or wall that is as close to the Blue Dot Receptor as possible. Ideally, the Blue Dot should be no more than 12 away from the controller (this is the length of the Blue Dot cable assembly). For door applications, just inside the door near the strike or latch is preferred. For garage door applications, the box should be mounted just outside of the garage door tracks. Fig. 1 Typical Box and Blue Dot Receptor Installation Marking and Cutting the Wall In Appendix D of these instructions there is a cut out template for the blue wall box. Using the utility knife cut out the marked section from the template. 1. On the secure side of the door, locate the outside edge of wall stud nearest the door. 2. Make a mark with the pencil on the wall showing the location of this edge. 3. Using the tape measure, measure up 46 ½ from the ground. Make a mark with the pencil showing this height. 4. Using the template, draw the outline for the hole. 5. Using the drywall saw, place the blade inside this outline about ½ away from the stud. With the saw teeth pointed toward the stud, push the saw blade into the wall until it either hits the stud or bottoms out. This will confirm the location of the stud. 6. Adjust the markings for the template so that the edge of the box is against the stud. 7. Cut out the rest of the hole using the saw. Page 3 of 13

Visible Wall studs Underneath Cut out Fig. 2 Detail of cut out placement Installing the Box Push the box in the hole, to check the fit. The box should fit snugly into the hole, but not so tight as to break the wallboard upon insertion. If the hole is too small, remove the box and shave a little more wallboard away in the necessary locations. When the box fits properly, insert it into the hole and use the phillips head screwdriver to tighten the screws in the upper right-hand and lower left-hand corners of the box until a mild resistance indicates clamps are set and snug. This will draw the box firmly against the wall. Mounting the Blue Dot Receptor On the doorframe mark a location 48 up from the ground. At this height, locate the center of the doorframe and mark the location for the center of the receptor. Using the 1 drill bit, drill a hole ½ deep. Change out the drill bit to the ½ bit. Continue drilling the center of the hole until it goes through the wall. From the outside, feed the white connector through the hole in the wall. Before pressing the Blue Dot completely into the hole, apply a ½ ring of RTV (or silicon caulk) into the outer hole (apply evenly). Press the Blue Dot the remainder of the way into the hole while gently pulling the remainder of the Blue Dot s cable through the hole from the inside. Page 4 of 13

CONNECTING UP THE CONTROLLER Bench Test Before you install the controller on the wall, you should follow the steps below, power up the controller and test it (See Figure 3). J6 P2 J7 SW3 J10 To Speaker To Blue Dot Receptor J4 J3 ibutton.com BlueDotLock Class 2 Compliant J5 X1 Power In A Power In B Not Used Normally Closed Normally Open Ground P1 ~1-Wire.net SW2 J11 SW1 J2 Square pin denotes pin1 on all connectors. Fig. 3 Wiring Connections for the Garage Door Application 1. Connect the receptor cable to J3 as shown in figure 4. Note the blue wire is on the out side. 2. Connect the speaker to J3 next to the receptor. 3. Connect the power supply to power in terminal A and B. 4. Separate power supply for the door controller and garage door opener is required. Page 5 of 13

Blue Dot Receptor (Blue wire on the first pin) Speaker goes here Fig. 4 Connection of Blue Dot and Speaker System Checkout 1. With power applied the LED in the Blue Dot should be pulsing like a heart beat. 2. Press the Reset button SW1 (see Figure 5 for location). The LED should turn on solid and the beeper should emit three tones followed by a few clicks and then the controller will go to sleep. 3. Press a valid ibutton key that you have added in the controller to the Blue Dot, the LED will turn on solid for 1 second and the controller will activate the garage door opener. (Please go to Appendix A for key operation instruction.) 4. If the controller did not activate see the table in Appendix B In case of difficulty. 5. Proceed to Completing the Installation Fig. 5 Location of the Reset Switch Page 6 of 13

COMPLETING THE INSTALLATION When the controller is operating properly, place the pink foam pad between the bottom side of the controller and wall box as you slide the tapered end of the controller into the box. Pink Foam Fig. 6 Installing the controller into the wall box Mount Options: Pushbutton Switch An optional door opener switch can be added in the garage door application. This switch (Trine model #544 or equivalent) can be used as a secondary door actuation button. Simply connect this switch across Input Power A and B along with the doorbell wire. When the button is pressed, it will provide an open signal to the door opener just like the standard button. EXPANING MEMORY 1. Insert a DS1996 ibutton into an open button holder face down. 2. Press the Reset button on the controller (See Figure 5). 3. The controller will be quiet for up to 10 seconds and will then emit 3 beeps followed by clicking. 4. When the clicking stops and the LED goes back to blinking, the memory expansion process will be complete. Page 7 of 13

Appendix A Manually Key management Enrolling a Sync ibutton into the controller 1. Verify the green LED in the center of the Blue Dot is blinking. This indicates the controller is operational. 2. Press and release the reset button (see Figure 5), the controller will emit 3 beeps followed by slow clicking for 5 seconds. 3. While the controller is emitting the clicking sound, press and hold the Sync ibutton (DS1996) to the Blue Dot Receptor. 4. The controller will emit a single beep followed by clicking for 3 seconds as the Sync ibutton is being enrolled. When the controller has completed this process it will emit 2 beeps. If the controller emits a long beep, it means the enrolling process was interrupted and must be attempted again starting at step 2. Adding a Key 1. Press the Sync ibutton to the Blue Dot Receptor. The controller will emit a single beep and green LED is light. 2. Remove the Sync ibutton and (within 3 seconds) press the new ibutton Key to the Blue Dot Receptor. The controller will emit two beeps confirming the addition of the key. If the controller emits a long beep, it means the enrolling process was interrupted and must be attempted again. NOTE: After the process of adding a key, the LED beacon in the controller may not be blinking. The beacon will start up again after the use an ibutton Key. Erasing All Keys 1. Verify the green LED in the center of the Blue Dot Receptor is blinking. This indicates the controller is operational. 2. Press and hold the Sync ibutton to the Blue Dot Receptor for 25 seconds. When the erasure is complete the controller will emit two beeps. (This is a long process and during this procedure the controller will emit fast clicking followed by a beep, 3 seconds of silence then slow clicking and finally two beeps.) If the controller emits a long beep, it means the erasing process was interrupted and must be attempted again. 3. Now only the Sync ibutton is enrolled in the controller. After erasing all the keys, the controller s LED beacon may not be blinking. The beacon will restart after an ibutton Key is used. ibutton Keys can now be added to the controller as described above. Download and install MyLocksmith for PC To perform normal operations on the Blue Dot Door Controller, Mylocksmith for PC software is required. You either download the software from UCA, Inc. web site or require a CD from your vendor. 1. Install the adapter and Blue Dot Receptor on the PC. Page 8 of 13

2. Access the Internet through your local ISP. 3. Go to 4. Download the MyLocksmith application. 5. Save download file to your hard disk, in case you need it to install again. 6. Extract the zip file to a known location on your hard disk (e.g. My Document folder). 7. Double click on the setup.exe file and follow the instructions. 8. Start the program from Start menu \ Programs \ Mylocksmith PC version 2.03. 9. At login window, use admin as the user name and dallas as password. Please do not modify the default system administrator (admin) user name. You can change the password to your preference. Note: To utilize the timetable function, a DS1996 ibutton and proper programming are required. Page 9 of 13

Appendix B In Case of Difficulty The LED does not pulse when power is applied. Verify the voltage on the input power terminals is between 12V and 24Volts. The LED does not turn on solid when switch SW1 is pressed. Verify that the white connector is on the correct pins of the J3 connector of the circuit board. The beeper does not emit sound when switch SW1 is pressed. Verify that the speaker connector is completely slid down on the mating connector. When power is applied, the LED comes on and the beeper emits four high tones, but then the circuit dies out and acts like power was just reapplied. The current supplied to the circuit board is insufficient. Move the jumpers on SW3 to a lower value of resistance. (Refer to the schematic in the appendix for resistance values.) When an ibutton key is pressed nothing happens. Verify the connection of the white connector. Verify that a voltage (between 3.5V and 6V) is present across the center contact of the Blue Dot and the outer contact. (Zero volts may indicate a broken wire.) Schematic The schematic for this controller can be obtained by contact UCA tech support at 972-437-4696 or send email to tech@ibuttonlock.com. Ordering more Keys Additional ibutton keys can be purchased from the ibuttonlock.com web site. Page 10 of 13

Appendix C RETURN POLICY Notwithstanding the provisions contained herein including but not limited to the Limited Warranty provisions an UCA, Inc. product shall be free from defects in material and workmanship. If an UCA, Inc. product fails operate to the published specifications within one (1) year from the date of purchase, please return the product for either repair or replacement. At UCA s sole discretion any product found not to operate within published specifications shall either be repaired or replaced free of charge. Within the warranty period, replacement or repaired product shall be shipped back to the purchaser free of charge. For warranty service, the customer must return the defective product at the owner s expense, complete with all operating parts including ibutton TM keys (if supplied), to UCA, Inc. at: RMA # UCA, Inc. Customer Service 610 Old Campbell Road Suite 100 Richardson, TX 75080 U.S.A. A copy of the sales receipt with the date of purchase must also be included, along with a brief statement of the defect. Please contact the UCA, Inc. Customer Service Department to receive a Return Material Authorization (RMA) number prior to returning the unit to UCA, Inc. This warranty does not apply in the event of improper installation or use outside of the published specifications of the product, or as a result of unauthorized alterations or repairs. WHAT IS COVERED DURING WARRANTY PERIOD: All replacement parts, labor and return transportation charges from UCA, Inc. to the user by standard shipping. WHAT IS NOT COVERED: Damages caused by abuse, improper installation or handling, transportation charges from the user to UCA, Inc., special delivery charges and cost to replace missing parts and/or ibutton keys. Page 11 of 13

LIMITED WARRANTY. UCA, INC. HEREIN EXPRESSLY DISCLAIMS ANY WARRANTY FOR THE UCA, INC. PRODUCT OR SUPPORT SERVICES OTHER THAN REPAIR OR REPLACEMENT OF A RETURNED DEFECTIVE PRODUCT UNDER UCA, INC. RETURN POLICY. THE UCA, INC. PRODUCT, THE SUPPORT SERVICES AND ANY RELATED DOCUMENTATION IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OR MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NONINFRINGEMENT. THE ENTIRE RISK ARISING OUT OF USE OR PERFORMANCE OF THE UCA, INC. PRODUCT AND SUPPORT SERVICES REMAINS WITH YOU. LIMITATION OF LIABILITY. IN NO EVENT SHALL UCA, INC. BE LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, OR ANY OTHER MONETARY LOSS) ARISING OUT OF THE USE, INSTALLATION OF OR INABILITY TO USE THE PRODUCT OR THE PROVISION OF OR FAILURE TO PROVIDE SUPPORT SERVICES, OR DAMAGES INCLUDING BODILY INJURY OR DEATH RESULTING FROM USE OR FAILURE OF PRODUCT EVEN IF UCA HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN ANY CASE, UCA, INC.'S ENTIRE LIABILITY UNDER ANY PROVISION OF THIS AGREEMENT SHALL BE LIMITED TO THE AMOUNT PAID FOR THE PRODUCT OR $4.00 WHICHEVER IS GREATER. Page 12 of 13

Appendix D WALL BOX CUT OUT TEMPLATE Page 13 of 13