PRODUCT. Data Sheet. Introducing the new Fluke-287 Advanced Logging Multimeters with Trend Capture

Similar documents
PRODUCT. Data Sheet. The new Fluke-289 Advanced Logging Multimeters with Trend Capture

Fluke 3000 FC Series Test Tools Technical Data

Detailed Specifications 6 1/2 Digits High-Performance DMM

Fluke 180 Series Digital Multimeters Features

Fluke Connect Modules Technical Data

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Fluke 8845A/8846A Digital Multimeters. Precision and versatility for bench or systems applications

Fluke 8845A/8846A Digital Multimeters. Precision and versatility for bench or systems applications

NEW! 6.5 Digit Precision Multimeter from Fluke

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

Fluke TiR Thermal Imager

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Fluke 8845A/8846A Digital Multimeters. Precision and versatility for bench or systems applications

Autoranging True RMS Multimeter User Manual

2020 System Calibrator

Manual Supplement. Manual Title: ESA609 Users Supplement Issue: 7 Print Date: February 2014 Date: 2/19 Revision/Date: 1 Page Count: 13

DIGITAL MULTIMETERS. Accuracy +5% Resolution 1pF Accessories Test leads, Manual, 9V Battery included Options ST-265, C-90, C W x 6 L x 1.

OPERATING INSTRUCTION

40,000-Count Dual-Display Handheld LCR Meters Models 878B, 879B, and 880

Mini Digital Multimeter

Circuit Breaker Analyzer & Timer CAT66

Programmable Relay ZEN V2 Units

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126

Model R5010. TRMS Digital Multimeter. Instruction Manual

USER'S MANUAL DCL-650

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

MS2115B Dual Display Digital Clamp Meter Operation Manual ZERO MIN RANGE HOLD

Professional Digital Multimeters

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

Keysight U2751A USB Modular Switch Matrix

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

3156 LEAK CURRENT HiTESTER

MTP INSTRUCTION MANUAL

MIC-2 MKII, Multi-instrument DATA SHEET

136 WESCHLER INSTRUMENTS

Series AMEPR60C-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Three-Phase Power Quality Analyzer PowerPad Model 3945

User Guide True RMS Multimeter Extech EX205T

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

Mini Digital Multimeter

ATL55, AAC3, ATT29, ATT70, 9V Bat., AF38, AF39. Range Resolution Accuracy DC Current DM393 DM µA 0.1µA 1.0% % + 2

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

Digital Clamp-on Meter Instruction Manual

ESA615 Electrical Safety Analyzer

Models 6522, 6524, 6526, 6532, 6534 & 6536

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

power quality Models 8230 & 8220

Universal Power Supplies

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

Circuit Breaker Analyzer & Timer CAT65

New products from Fluke

NI PXI-2567 Specifications

DUAL DISPLAY L/C/R METER ELC-132A/ELC-133A USER MANUAL

CALYS 50. Field multifunction calibrator for basic use. Calibration measurement

True RMS Digital Bench Multimeter Model:

Series Watt DC Power Supplies

350 Series AC/DC Clamp Meters

Autoranging Mini Multimeter

5000V Digital/Analog Megohmmeter Model 5060

700 Series 200 Amp Clamp Meters

Bench Multimeter. Users Manual

Three-Phase Power Quality Analyzer PowerPad Model 3945-B

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

Digital Multimeter User's Manual

DSO3062A Oscilloscope, 60 MHz

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

VP ELECTRONIQUE MASSY - Tel

Leak Current Measurement - Essential to Electrical Safety. Compliance with IEC :2005 Ed 3.0, JIS T :2012

Installation Instructions

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

Circuit Breaker Analyzer System

Model. True RMSmA Clamp Meter. Instruction Manual

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

Versatile, Automatic RCL Meters

ScopeMeter 190C/190 Series and ScopeMeter 123

Power Prowler USER MANUAL PLR In-1 DMM/TDR Cable Fault Finder for Energized and Unenergized Cables.

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Model A Mini AC/DC Clamp Meter. User's Guide

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Circuit Breaker Analyzer & Timer CAT31

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

Mini Digital Multimeter

Zelio Control-modular measurement and control relays 1

C100 Portable Multifunction

C B. Models. Ultra wide 4:1 input voltage 20 W DC/DC. edition and EN55032 class A

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

Advanced Test Equipment Rentals ATEC (2832)

Agilent U2751A USB Modular Switch Matrix. Data Sheet

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

1660 Series Installation testing that protects appliances, wirelessly shares data

Wireless TRMS Multimeter and Insulation Tester

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Transcription:

PRODUCT Data Sheet Introducing the new Fluke-287 Advanced Logging Multimeters with Trend Capture Fluke s newest and most advanced line of multimeters ever. Setting industry trends and putting your customers on the cutting edge. The Fluke-287 is the ultimate handheld tool for any application demanding real precision. They feature advanced logging capabilities with Trend Capture and a TRMS 50,000-count graphic dot matrix display. Product Conversion - See Sales conversion guide literature number 3050819 for full details OLD Fluke-187 Fluke-189 Fluke-189/FVF2 NEW Fluke-287 Fluke-289 Fluke-289/FVF

New Fluke-287 & Fluke-289 Advanced Multimeters Continued Fluke-287 True-RMS Electronic Logging Multimeter with TrendCapture The Fluke-287 replaces the previously discontinued Fluke-187. The advanced, logging digital multimeter with high accuracy and TrendCapture electronics professionals depend on. The Fluke-287 True-rms Electronics Logging Multimeter with TrendCapture quickly documents and graphically displays design performance. Its unique logging and graphing capabilities mean you no longer need to download logged readings to a PC to detect a trend. The Fluke-287 incorporates more accuracy and convenience into a handheld multimeter than ever before. Where is the Fluke-287 used and for what applications/market segments? Develop, install, or maintain electronic devices Precision testing of surface mount and high density circuits Customers who need to log and record results to solve intermittent problems Communication; wireless, wired, LAN, broadband, CATV, audio/video Industrial / Electrical equipment Instrumentation (example: test and medical equipment ) Consumer electronics Automotive Education Security Typical Fluke -287 Users Include: Application Engineer R&D/Development Engineer Design Manager Electronic Maintenance Electronics Engineers Electronics Technician Field Service Engineer Instrumentation Specialist Maintenance Manager Senior Engineer Service Manager Bench Test Technicians Rework Engineers Quality Technicians Page 2

New Fluke-287 Advanced Multimeters Continued The NEW Fluke-287 is equipped with functionality that electronics professionals need most. New Large 50,000 count, ¼ VGA (320 X 240) dot matrix display with white backlight. Multiple sets of measurement information can be simultaneously displayed. New Logging function with TrendCapture. Useful for characterizing the performance of a design or for unattended monitoring while in the field. Users can review logged readings without needing a PC. New battery saving sleep mode allows data logging for over 200 hours uninterrupted (six AA Batteries) New Multiple logging sessions possible without download New Saved measurements allow you to name and recall measurements made in the field New i-info button. On-board help screens for measurement functions. Unsure about a function go to the function and press the i button. Info screens are in English, German, French, Spanish, Italian, Japanese, and Simplified Chinese. 0.025 % basic dc accuracy 100 khz ac bandwidth Real time clock for automatic time stamping of saved readings True-rms ac voltage and current for accurate measurements on complex signals or non-linear loads. AC bandwidth specified to 100 khz. Relative mode to remove test lead resistance from low ohms or capacitance measurements Measure up to 10 A (20 A for 30 seconds) 100 mf capacitance range Temperature function Limited Lifetime Warranty Dual rated CAT IV 600V, CAT III 1000V For a full list of detailed functionality & additional new features, please visit www.fluke.com/287 Included Accessories TL71 Test leads AC72 Alligator clips 6 AA batteries CD ROM Operators Manual Printed Getting Started Manual (English, French, Italian, German, Spanish, Portuguese, Dutch, Finnish, Swedish, Japanese, Korean, Chinese (Traditional) Chinese (Simplified), Russian) Page 3

Fluke 287 Specifications Voltage DC Accuracy 0.025 % Range and 50.000 mv,500.00 mv, 5.0000 V, 50.000 V, 500.00 V, Resolution 1000.0V Voltage AC Accuracy 0.4 %(true-rms) Range and 50.000 mv,500.00 mv, 5.0000 V, 50.000 V, 500.00 V, Resolution 1000.0V Current DC Accuracy 0.06 % Range and 500.00 µa, 5000.0 µa, 50.000 ma, 400.00 ma, 5.0000 Resolution A, 10.000 A Current AC Accuracy 0.6%(true-rms) Range and 500.00 µa, 5000.0 µa, 50.000 ma, 400.00 ma, 5.0000 Resolution A, 10.000 A Temperature (excluding probe) Accuracy 1.0 % Range and Resolution -200.0 C to 1350.0 C (-328.0 F to 2462.0 F) Resistance Accuracy 0.05 % Range and 500.00 Ω, 5.0000 kω, 50.000 kω, 500.00 kω, 5.0000 Resolution MΩ, 50.00 MΩ, 500.0 MΩ Capacitance Accuracy 1.0 % Range and 1.000 nf,10.00 nf 100.0 nf, 1.000 µf, 10.00 µf, 100.0 Resolution µf, 1000 µf, 10.00 mf, 100.00 mf Frequency Accuracy 0.005% + 5 Range and 99.999 Hz, 999.99 Hz, 9.9999 khz, 99.999 khz, Resolution 999.99 khz Additional functions/features Environmental Specifications Operating Temperature -20 C to +55 C Storage Temperature -40 C to +60 C Multiple on-screen displays True-rms AC bandwidth 100 khz DBV/dBm Conductance 50.00nS Continuity beeper Battery/Fuse access Battery / Fuse Peak 250 μs Elapse time clock Time of day clock Min-Max-Avg Duty Cycle 0.01 % to 99.99 % Pulse Width 0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms Hold Isolated Optical Interface Auto/Touch Hold Reading memory Log to PC Interval/Event Logging Logging Memory Up to 10,000 readings Relative Humidity 0% to 90% (0 C - 37 C)

0% to 65% (37 C - 45 C), 0 to 45 % (45 C - 55 C Electromagnetic Compatability EMC EN6 1326-1 Vibration Random vibration per MIL-PRF-28800f Class 2 Shock Safety Specifications Overvoltage category 1 meter drop per IEC/EN 61010-1 2nd edition CAT III 1000 V / CAT IV 600 V safety rated Agency Approvals CSA, UL, TÜV, CE Mechanical & General Specifications Maximum voltage between any terminal and earth ground 1000V Size Weight Battery Life Battery type (HxWxL 22.2 cm x 10.2 cm x 6 cm (8.75 in x 4.03 in x 2.38 in) 870.9 g (28 oz) 100 minimum, 200 hours in logging mode 6 AA alkaline batteries, NEDA 15A IEC LR6