FTS / FTP Test Blocks & Plugs

Similar documents
Safety Test Switch. Reference Handbook. STS-reference-en v

SAX / PAX Test Blocks & Probes

ITS / STP Test Blocks & Plugs

MMLG 01, 02, 03, 04 MMLB01

REYROLLE 2RMLG. Operating Recommendations

satech TSB-14 MAIN FEATURES

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A

MiCOM Agile P99x. Grid Solutions. Testing & Commissioning. Test Block, Multi-finger Test Plug and Single-finger Test Plug. Design Flexibility

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

FT Flexitest Family. Switches, Covers and Test Plugs

icore Kiosk system Installation Guide

HV-CS kv Edge Mount Triaxial Jack

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

TRC-190 User s Manual

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

RM84 miniature relays

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

BIPOLAR OPERATIONAL POWER SUPPLY

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Messaging module CP-C MM

TRC-190 User s Manual

MRT1 Test Unit. Manual MRT1 (Revision A)

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY I INTRODUCTION

Replacing the Power Supply

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Earth-fault Relay SPAJ 110 C. Product Guide

G12/G12x USER S MANUAL

Power Supply and Fan Module Installation

INSTRUCTION MANUAL RA 59 RACK ADAPTER. 1) This manual is valid for the following Model and associated serial numbers: MODEL SERIAL NO. REV. NO.

Installation Job Aid for Ethernet Routing Switch 3600 Series

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

C5C Cross-Connect System

Solid-state Timer H3YN

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Model 7705 Control Module

Redundancy unit CP-A RU

FT & RT Test Switches

FLEX Ex Spring Clamp Terminal Base

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Operating Instructions for Digital Thermometers. Model: DTM

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

EX-RC1 Remote I/O Adapter

POSEIDON SCIENTIFIC INSTRUMENTS PTY LTD 17 QUEEN VICTORIA ST, FREMANTLE WA PHONE (08) FAX (08) MWA-3011

Procedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

PI84 with socket GZM80 interface relays

IDG-B Enclosures for Industrial and Building Automation Controls.

Feeder protection relay SPAA 121 C. Product Guide

B-Box H Installation Guidance

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

Residual overvoltage relay

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

INSTALLATION MANUAL SLI 50 INVERTER

SECTION SWITCHBOARDS

Analog display for resistance current

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

Power Supply Installation

SLI 15 INVERTER SERIES, 1500 W

Installation Notes TII Model 341 Protector

ME PLC Multifunctional housing for complex electronics. Data sheet _en_01. 1 Description

60103 Circuit Breaker

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

Model 2380 Rack-Mount Kit

POSEIDON SCIENTIFIC INSTRUMENTS PTY LTD 17 QUEEN VICTORIA ST, FREMANTLE WA PHONE (08) FAX (08) MWA-3014

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

Installing the Cisco AS5400XM Universal Gateway

V E2B Snap-in I/O Module

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Electronic timer CT-ERD.12

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

MBE Mounts and Adapters

Operating instructions. Standstill monitor A / / 2011

Multitronic. Technical data

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

MDM 011-Z1 Regen Resistor

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules

Supplementary instructions. Plug connector Harting HAN 8D. for continuously measuring sensors. Document ID: 30376

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

EMC1600 Series Media Converter and Ethernet Extender Chassis

Model 2657A-LIM-3 LO Interconnect Module

C-POWER AC AUTOMATIC CONTROL

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Transcription:

FTS / FTP Test Blocks & Plugs Reference Handbook fts-reference-en v.154

Copyright Notice All information provided in this document is the property of SECUCONTROL. SECUCONTROL grants its customers or potential customers the right to download, copy, store and print this document for the sole purpose of assisting them in the correct application of the products mentioned in this documet. All other uses of this document are expressely prohibited. Intellectual Property Notice This publication contains proprietary information under protection of the following (among others) patents: DE 10 2005 025 108, DE 10 2008 016 388, US 7,271,357 and US 7,884,597. Contents Disclaimer Although the information and recommendations in this document are presented in good faith and believed to be correct as of publication date, SECUCONTROL makes no representations as to the completeness or accuracy thereof. In no event shall SECUCONTROL be responsible for damages of any nature resulting from the use of or reliance upon the contents of this document. Continuous Improvements Products developed by SECUCONTROL are continuously improved. The information in this document may, therefore, be out of date. Please make sure you have the latest release of this document before proceeding by checking its name and revision code. This information is printed on the front cover of this document, underneath the title. The latest release of this document can be downloaded from www.secucontrol.com/downloads. Alternatively, you may contact SECUCONTROL at any of the addresses provided on the rear cover of this document.

Contents 1 Introduction 1 The FTS / FTP Test Block & Plug...................... 1 Key Features................................. 1 Applicable Models.............................. 1 Unpacking................................... 1 Part Number and Manufacturing Date Location............... 2 Safety Symbols................................ 2 General Safety Instructions.......................... 2 2 Principle of Operation 3 Closed Circuit................................. 3 Open Circuit, Signal Injection........................ 3 Current Transformers............................. 3 3 Application 5 Schematic Symbols.............................. 5 Typical Connection Schematic........................ 6 4 Installation 7 Panel Cutouts, Drilling Plans and Mounting................. 7 Wiring..................................... 8 5 Operation 11 6 Technical Specifications 13 Electrical................................... 13 Mechanical.................................. 13 Dimensional Drawings FTS.......................... 14 Dimensional Drawings FTP.......................... 17 7 Accessories 23 Cases for FTP Test Plugs........................... 23 Individual Test Probes............................. 23 Universal Test Probes Set........................... 23 Current Measurement Probe......................... 24 FTS 19 Rack Plates............................. 24 Covers for 19 FTS Rack Plate Cutouts................... 26 8 Spare Parts 27 i

ii CONTENTS Dust Covers.................................. 27 Fitting Set................................... 27 9 Ordering Information 29 Part Numbers for FTS Test Block....................... 29 Part Numbers for FTP Test Plug....................... 29 Available Configurations........................... 29

1 Introduction The FTS / FTP Test Block & Plug The FTS is a test block for interfacing substation devices (protection relays, fault recorders, revenue meters,... ) to the voltage and current transformers and to other equipment on the system side of a power grid. The FTP is a test plug keyed to a particular configuration of FTS Test Blocks. Once inserted into the corresponding Test Block, the FTP Plug isolates the substation devices from the system side equipment while at the same time allowing connection of test equipment for secondary injection tests. Key Features Finger-safe Test Block and Test Plug increase safety during testing. Test Plugs are keyed to the corresponding Test Blocks and help eliminate of the most common human errors during testing. Construction of Test Plugs prevents contact between test set and current and voltage transformers during insertion / removal and allows test during operation. Built-in time-sequencing of disconnection / reconnection operations prevents spurious breaker operation. Extremely low internal resistance (< 2 mω) helps reduce heat inside cabinets and panels. Available in 8, 10, 12, 14, 16, 18 or 20 pole configurations. Test plug handle is functionally and ergonomically designed and enables an easy plug and plug out process. Applicable Models Information in this document applies to all FTS Test Blocks and FTP Test Plugs manufactured after May 2011. Unpacking Unpack the product carefully and make sure that all pertinent parts like dust covers and screws are put aside so they will not be lost. 1

1. INTRODUCTION Check the contents against the packing list. If any of the contents listed are missing, please contact SECUCONTROL immediately (see contact information at the rear cover of this manual). Examine the product for any shipping damage. If the product is damaged, notify the shipping company without delay. Only the consignee (the person or company receiving the unit) can file a claim against the carrier for shipping damage. Part Number and Manufacturing Date Location Part number and manufacturing date are stated on a label on the right side of the Test Block or Test Plug. Safety Symbols The following symbols are located on different parts of the equipment and in this manual: Paragraphs marked with this symbol contain information which, if not properly followed, may cause damage to the equipment and/or installation. Paragraphs marked with this symbol contain information which, if not properly followed, may cause personal injury or even death. General Safety Instructions Installation and operation of the products described in this manual is only to be performed by personnel that has been trained or is knowledgeable in substation protection, automation and control. This instruction manual is an integral part of the scope of delivery and provides basic instructions for installation and operation of the equipment here described. Shall additional information be needed, please contact SECUCONTROL at any of the addresses provided on the rear cover of this document. Do not disassemble the Test Block. Correct alignment of internal parts is critical in order to provide insulation and arch-avoidance. The warranty will be void if the Test Block is disassembled (or otherwise handled inappropriately). SecuControl does not assume responsibility for any damages arising out of mishandling of our products, including test blocks that have been disassembled by parties other than SecuControl. 2

2 Principle of Operation Closed Circuit In the resting state the FTS test block s contacts are closed, signals from the system side (side A) are connected by flat springs to the panel devices (side B). Open Circuit, Signal Injection To open the test block s contacts, the FTP Test Plug is inserted into the FTS Test Block. In this situation, the devices in the panel (side B) are isolated from the system side (side A). Signals can be injected using the banana jacks on the front side of the FTP Test Plug. Current Transformers The FTP Test Plugs automatically short-circuits the secondaries of current transformers. The short-circuiting happens before the contacts are open ( make-beforebreak ). 3

3 Application Schematic Symbols Following symbols are suggested in order to represent the FTS Test Block in schematic diagrams. Symbol Description Signal, Voltage (single pole) S V Current (2-pole, 4-pole) C - - C C - - C - - C - - C 5

3. APPLICATION Typical Connection Schematic 10 004 AA 1 3 5 7 9 11 13 15 17 19 C - - C C - - C C - - C V V V V 2 4 6 8 10 12 14 16 18 20 3 2 1 N 6

4 Installation Panel Cutouts, Drilling Plans and Mounting Use the provided M5x30 screws to fix the FTS Test Block onto the panel. The screws should be tightened using a 4 mm hex drive. 8-pole Models 5.2mm 0.205in 111mm 4.370in 28mm 1.102in 10-pole Models 5.2mm 0.205in 134mm 5.276in 28mm 1.102in 12-pole Models 5.2mm 0.205in 157mm 6.181in 28mm 1.102in 7

4. INSTALLATION 14-pole Models 5.2mm 0.205in 180mm 7.087in 28mm 1.102in 16-pole Models 5.2mm 0.205in 203mm 7.992in 28mm 1.102in 18-pole Models 5.2mm 0.205in 226mm 8.898in 28mm 1.102in 20-pole Models 5.2mm 0.205in 249mm 9.803in 28mm 1.102in Wiring Electrical connection terminals are located on the top and bottom of the FTS Test Block. The connection terminals combine a screw in the center with a pressure plate, accepting ring cable lugs, stripped wire or other crimp connectors. 8

Wiring Recomended wire gauge is from 1.5 mm 2 (AWG 16) to 4 mm 2 (AWG 12). CTs should be wired to the terminals provided for this purpose (in 2- or 4-pole combinations) to ensure automatic short circuiting upon insertion of FTP test plugs or individual test probes into the FTS Test Block. The terminals designated for the connection of the CTs can be typically identified by the C- -C or C- -C- -C- -C labeling 1. The panel equipments (protection relays, meters, fault recorders, etc) should be connected to the device side terminals indicated by the odd-numbers (1, 3, 5, 7,... ), or by the b suffix (1b, 2b, 3b,... ), depending on model. The protection equipments (current and voltage transformers, breaker, etc) should be connected to the system side terminals indicated by the even-numbers (2, 4, 6, 8,... ), or by the a suffix (1a, 2a, 3a,... ), depending on model. 1 Custom labeling may show other symbos or use other colors. 9

5 Operation Handling of the FTP Test Plugs or Test Probes should be done using only the handle and/or insulated plastic parts, since the fingers may be connected to live equipment either via the test block or test equipment. Store the FTP Test Plugs and Test Probes carefully in order to avoid damage to the metallic test fingers. SECUCONTROL recommends using one of the cases listed under Accessories on page 23. 1. Remove the dust cover by sliding the cover up and then out. 2. Connect cables from the test set onto the corresponding FTP Test Plug or Test Probe. There is no need to externally shot-circuit the current transformers, since the FTP Test Plugs and Test Probes have internal shorting bars which will automatically short circuit the corresponding circuits before opening them. 3. Carefully align the FTP Test Plug or Test Probe with the corresponding positions on the FTS Test Block. 4. Insert the FTP Test Plug or Test Probe in one smooth movement into the FTP Test Block. 5. Once you are ready to resume normal operation, remove the FTP Test Plug or Test Probe in a single, continuous movement. 6. Reattach the dust cover. 11

6 Technical Specifications Electrical Current Withstand Maximum voltage Contact resistance Dielectric Withstand Voltage Impulse Temperature Range 30 A continuously 500 A for 1 second 600 V UL94 Flammability Class V-0 Enclosure Protection 2 mω 3.0 kv RMS for 1 minute between adjacent contact pairs and between any contact pair and other metal parts 2.0 kv RMS for 1 minute between open contacts when test plug is inserted 3 positive and 3 negative impulses of 5 kv peak, 1.2/50 µs, 0.5 J between adjacent contact pairs and between all contact pairs and other metal parts 25 to +70 C ( 13 to +158 F), storage 25 to +55 C ( 13 to +131 F), operation IP20 without cover IP50 with dust cover attached FTS / FTP Test Blocks and Plugs are classified as electromagnetically benign and are therefore excluded from the scope of the European Community EMC Directive 2004/108/EC. FTS / FTP Test Blocks and Plugs meet or exceed all requirements from ANSI / IEEE C37.90-2005. Mechanical # of poles 8 10 12 14 16 18 20 FTS Weight (kg) 0.94 1.13 1.31 1.50 1.68 1.86 2.05 (lbs) 2.07 2.49 2.89 3.31 3.70 4.10 4.52 13

6. TECHNICAL SPECIFICATIONS Dimensional Drawings FTS 8-pole Models 70mm 2.756in 130mm 5.118in 34mm 1.339in 102mm 4.016in 10-pole Models 70mm 2.756in 153mm 6.024in 34mm 1.339in 102mm 4.016in 12-pole Models 70mm 2.756in 176mm 6.929in 34mm 1.339in 102mm 4.016in 14

Dimensional Drawings FTS 14-pole Models 70mm 2.756in 199mm 7.835in 34mm 1.339in 102mm 4.016in 16-pole Models 70mm 2.756in 222mm 8.740in 34mm 1.339in 102mm 4.016in 18-pole Models 70mm 2.756in 245mm 9.646in 34mm 1.339in 102mm 4.016in 15

6. TECHNICAL SPECIFICATIONS 20-pole Models 70mm 2.756in 268mm 10.551in 34mm 1.339in 102mm 4.016in 16

Dimensional Drawings FTP Dimensional Drawings FTP 10-pole Models 150mm 5,906in 82,4mm 3,245in 45,5mm 1,791in 240,4mm 9,465in 17

6. TECHNICAL SPECIFICATIONS 12-pole Models 173mm 6,811in 82,4mm 3,245in 45,5mm 1,791in 240,4mm 9,465in 18

Dimensional Drawings FTP 14-pole Models 196mm 7,717in 82,4mm 3,245in 45,5mm 1,791in 240,4mm 9,465in 19

6. TECHNICAL SPECIFICATIONS 16-pole Models 219mm 8,622in 82,4mm 3,245in 45,5mm 1,791in 240,4mm 9,465in 20

Dimensional Drawings FTP 18-pole Models 242mm 9,528in 82,4mm 3,245in 45,5mm 1,791in 240,4mm 9,465in 21

6. TECHNICAL SPECIFICATIONS 20-pole Models 265mm 10,433in 82,4mm 3,245in 45,5mm 1,791in 240,4mm 9,465in 22

7 Accessories Cases for FTP Test Plugs Rugged case for FTP Test Plugs with handle or Test Probes. Description Case for FTP Test Plug Case for FTP Test Probes Order Code CFTP1 CFTP2 Individual Test Probes This probes will fit all FTS Test Blocks, regardless of configuration. Keying in the probes prevents insertion into wrong circuits (i.e., 2-pole current probes can only be inserted into a 2-pole current part of a FTS block). Current probes include internal shorting bridge. Description Single pole probe (voltages, signals and trips) 2-pole probe (single current and return) 4-pole probe (three currents, common return) Order Code FTPA01TVSAA FTPA020C2AA FTPA040C4AA Universal Test Probes Set Set of individual test probes in a rugged case. Two configurations are available: Small Set 3 2-pole current probes (for single currents and return) 1 4-pole current probes (for three currents and common return) 6 single pole probes (for voltages, trips and signals) 23

7. ACCESSORIES Large Set 6 2-pole current probes (for single currents and return) 2 4-pole current probes (for three currents and common return) 12 single pole probes (for voltages, trips and signals) Description Universal Test Probe Set Small Universal Test Probe Set Large Order Code UFTP1 UFTP2 Current Measurement Probe This special test probe allows for the connection of a current measurement device or a shunt. The AWG 13 (2.5 mm 2 ) connection cable has a length of 118 inches (3 meters). The test probe is available with c-hook terminals or banana plugs. The current measurement probe is a special tool that is built for current measurement purposes. It does NOT automatically short-circuit current transformer circuits upon insertion into the FTS test block. Instead, current circuits are opened and redirected via the attached wires once the probe is entered into the test block. The probe must always be correctly connected to a measurement instrument or a shunt before insertion into the FTS test block, to prevent the creation of an open current transformer circuit. The current measurement probe should be used by properly trained personnel only. Description C-hook connection Banana plug connection Order Code UTPC1 UTPC2 FTS 19 Rack Plates SECUCONTROL offers metal plates for installation of FTS test blocks in 19 racks that come painted in various colors and with various cutouts for FTS test blocks, in standard heights of 2U or 3U. Please contact SECUCONTROL if you require drawings or special customizations. The picture below shows an ANSI-grey #61 rack plate with three cutouts for 10-pole FTS test blocks. 24

FTS 19 Rack Plates F T x U }{{} height }{{} config. }{{} cutouts }{{} color height config. cutout color Rack plates are available in 2U and 3U A: standard 19 rack plates, 2mm thick with standard cutouts B-Z: reserved for special configurations e.g.14xx16 cutout for one 14-pole (left) and one 16-pole (right) FTS test block e.g.14xxxx cutout for one 14-pole (left) FTS test block e.g.xxxx18 cutout for one 18-pole (right) FTS test block e.g.100810 cutout for one 10-pole (right), one 8-pole (middle) and one 10-pole (right) FTS test block max. modules per rack plate = 30 These two digits define rack plate colors. Available options can be found in the table below: Color Description AG ANSI-grey #61 PG pebble grey RAL 7032 LG light grey RAL 7035 BK black For all configurations with 3 cutouts and 30 modules (e.g. 3 x 10-pole cutouts), SECUCONTROL recommends special FTS fitting screws (M5x22). These screws should be mounted on the far left and the far right side of the rack plate, to prevent the tip of the screws from touching the mounting frame. Two special screws are included with every FTS rack plate with 3 cutouts\30 modules. Please use the order codes below for reordering. Special FTS Fitting Screws Fitting set to fix the FTS Test Block in the rack plate cutout with 3 cutouts and 30 modules. The screw set contains two M5x22 hexagon socket head cap screws (4 mm) Description Special fitting set M5 Order Code SCPFT 25

7. ACCESSORIES Covers for 19 FTS Rack Plate Cutouts Built to cover existing cutouts in rack plates for FTS test blocks, these metal covers are offered for different FTS cutout sizes. Description Order Code Order Code Order Code Order Code ANSI-grey #61 light grey pebble grey black 8 -pole cover FTBC08AG FTBC08LG FTBC08PG FTBC08BK 10-pole cover FTBC10AG FTBC08LG FTBC08PG FTBC08BK 12-pole cover FTBC12AG FTBC08LG FTBC08PG FTBC08BK 14-pole cover FTBC14AG FTBC08LG FTBC08PG FTBC08BK 16-pole cover FTBC16AG FTBC08LG FTBC08PG FTBC08BK 18-pole cover FTBC18AG FTBC08LG FTBC08PG FTBC08BK 20-pole cover FTBC20AG FTBC08LG FTBC08PG FTBC08BK 26

8 Spare Parts Dust Covers # of poles Order Code 8 FTDC08 10 FTDC10 12 FTDC12 14 FTDC14 16 FTDC16 18 FTDC18 20 FTDC20 Fitting Set Fitting set to fix the FTL Test Block in the panel cutout. The screw set contains two M5x30 hexagon socket head cap screws (4 mm) and two M5 nuts. Description Fitting set M5 Order Code SCSFT 27

9 Ordering Information Part Numbers for FTS Test Block F T S A }{{} poles }{{} config }{{} labeling Part Numbers for FTP Test Plug F T P P }{{} poles }{{} config }{{} labeling Available Configurations A list of available Configurations can be found in the download section of out website. Should your application require a configuration that is not listed below, please contact SECUCONTROL at any of the addresses listed on the rear cover of this manual, or use the configurator on our homepage. 29

North America SecuControl Inc. 2873 Duke Street Alexandria, VA 22314 USA Tel +1 703 838 7677 mail@secucontrol.com www.secucontrol.com Europe SecuControl GmbH Ascherslebener Str. 3 D-06333 Hettstedt Germany Tel +49 3476 550 022 info@secucontrol.com www.secucontrol.com South America SecuBrasil Ltda Rod José Carlos Daux, 8600 88050-001 Florianópolis SC Brazil Tel +55 (48) 3371 1670 comercial@secubrasil.com www.secubrasil.com