DESIGO 30 Remote operator terminal. for more then one HVAC systems en. menu + esc

Similar documents
DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Room unit with PPS2 interface

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

Room unit with PPS2 interface

Room unit with PPS2 interface

Room unit with PPS2 interface

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

PXM20-E. Operator unit BACnet auf Ethernet/IP DESIGO PX

Rotary version, three-position control

Universal Controller

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

EY-EM : Remote I/O module, ecolink

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Immersion Temperature Sensors

Room Temperature Controllers

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Non-communicating room controllers

EY-IO 534: I/O module, analogue inputs with galvanic isolation, modu534

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Automation stations compact model

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Semi flush-mounted room temperature controllers with LCD

I/O module, universal, digital, S0 inputs, modu533

Master room unit for RRV controllers

I/O module, digital and universal inputs, modu530

Digital input modules

VAV compact controller KNX / PL-Link

RXL21.1 RXL22.1. Room controllers RXL. Communicating controllers for fan-coil applications FC-10, FC-11, FC12

TXM1.8RB. TX-I/O Blinds module

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

USB-KNX Interface OCI702. USB-KNX interface with cables and service bag

M-Bus Central Unit OZW10

Room Temperature Controller

M3P..G/A, M3P..F/A Modulating control valves (PN16) for chilled and hot water systems

Electromotoric actuators

EY-RU : Room operating unit, ecounit

Switching module for AC V and up to three load stages, with manual switching

PXR11 PXR12. System controllers DESIGO PX

Resistance measuring module

FX Input/Output (I/O) Modules XM07 and XM14

Room automation station

Electrical Actuators

VAV compact controller

VAV modular controller

Power supply module, bus connection module

Electrical Actuators

VAV modular controller

Electrical Actuators

252F 5WG FB_1 DELTA

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

PIU-A Universal interface for occupancy sensors

Temperature Controller (Heat Pumps)

Air damper actuators

Semi flush-mounted room temperature controllers with LCD

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

M-Bus Central Unit. Use

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

Electromotive actuators for combi valves

Room Temperature Controller

Extension module for BACnet over Ethernet / IP and graphic Web functions

Temperature controller Ducted systems

Technical data. PRCA-BAC-S2-T en-gb subject to changes 1

CP BACNET Function

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Status display unit with P-bus connection

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

modu : Local override and indicating units

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Airflow Pressure Sensor

VAV compact controller GDB181.1E/3 GLB181.1E/3

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Semi Flush-mount Room Temperature Controllers with LCD

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

I/O module, digital outputs (relays), modu550

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

I/O module, analogue outputs and universal inputs

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

OCI Service Tool. Siemens Building Technologies HVAC Products. ACS plant operating software and OCI700 service interface

Rotary actuators for ball valves

ED-T7. External touch display, 7 inch. Function. Installation The display can be mounted, for example, on the operation panel of the control cabinet.

EY-RU : Room operating unit, ecounit

Operating and mounting instructions

OP10. Pre-programmed, configurable controller for simple applications

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Extension module for lighting control

Web interface BACnet/IP

Pre-programmed room controller with display and communication

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Installation and User Guide

I/O module, digital outputs (open collector), modu551

OCI Service tool. As of ACS790 V9.00. Service case with software and service interface

Super universal modules

EY-RU 355: Room operating unit, ecounit355

Transcription:

3 292 DESIGO 30 Remote operator terminal for more then one HVAC systems BCO Operator terminal for remote operation of several HVAC systems incorporating DESIGO 30. Optimum design for control panel installation. Display several measured values Display and adjust several setpoints Alarm indication Switch systems on and off Modify 7-day and date programmes Use / Functions The BCO remote operator terminal is suitable for all RCK... controllers and for the RCH1. It is not yet available for use with the RCS... or RCH2 controllers. The BCO remote operator terminal is connected to the LON bus, so allowing user access to the data in the DESIGO 30 devices (with a maximum of ten devices in each subnet). Menus or data points are selected with the navigation keys. The selected item (indicated by an arrow in the display) can be modified with the keys + and. Modified values are accepted with and operation is terminated with esc. Values (e.g. the measured value and setpoint) are assigned to the hot keys A and B in the engineering phase. The keys for general operation can be used to jump directly to the relevant menus, allowing you to adjust the plant status or the time switch, or to acknowledge alarms. The LEDs give a visual indication of the output values of a controller. The controller value assigned to each LED can be written in the labelling space provided. 60323en alarm WU : Out. Heating Y1 WU : Out. Cooling Y3 WU : Output Frost WU : Out. Digital Y2 88L : Step II 22 : Out. Digital Y2 22 : Out. Digital Y4 mode A B menu + esc 7 6 5 4 3-1 2 Key 1 Display 2 Hot keys 3 Editing keys 4 Navigation keys 5 Keys for general operation 6 8 status LEDs 7 Labelling spaces Siemens Building Technologies CA2N3292E / 03.1999 Landis & Staefa Division 1/6

Mounting / Installation This BCO remote operator terminal is designed primarily for installation in control panels. The operator terminal is wired directly into the LON network and an AC 24 V power supply. Alternatively, use the cable supplied, connecting it directly to the service socket of a controller (for LON bus communications and power). The BCO has two identical sockets, one for power / LON connection and the other for connecting an additional service terminal or as a LON extension connection. See Manual R21 section 04.20 for detailed installation instructions. Accessories Connecting cable Fixing wire clip (see section "Dimensions") BCO User manual R26 Commissioning / Engineering The BCO is prepared for operation using the APED 30 service software. The possible settings are as follows: Allocation of two data points each to the A and B hot keys Allocation of the values to be displayed by LED Labelling of the values Defining the target subnet Commissioning: see Manual R21 section 06.21 Engineering: see Manual R21 section 06.22 Menu tree Operation takes place in three basic stages: Start-up Device list (Network operation) BCO settings Start-up Device list Device 1 Device 2 Device 3 Alarm Schedules Week programme 60326 Inputs Date programme Outputs Setpoint Plant status BCO settings SW version CA2N3292E / 03.1999 Siemens Building Technologies 2/6 Landis & Staefa Division

Start-up Notes on the display The Start-up menu displays all the main values from the most recently selected system. For plant values which are not available, two dashes ( ) appear in the display. If a value has been manually overridden with the BCS or the APED 30 software, this is indicated with the symbol directly in front of the value. In the event of an alarm, the plant status display is replaced by 'ALARM'. System name Plant status RCK88-L West building * Auto * 10.03.95 / 13.35 65.2%rh 20.4 C Date and time Values assigned to the hot keys A Hot keys B Device list / BCO settings From the Start-up menu, the user can access the Device list / BCO settings menu by pressing the menu key. This allows the following activities: Selection of a controller from the device list Modification of the BCO settings > Device list BCO settings Controller operation A list of all the controllers connected to the bus is displayed on start-up or after selection of the Device list menu: > RCK88-L West building RCK82 Warehouse ventilation ALARM When a controller is selected from this list, the display switches to a menu containing the controller-specific data. This is the menu used to read and/or modify all data related to the selected controller. Depending on the controller type, up to seven controllerspecific menus can be displayed. > Alarm Schedules Inputs Outputs Setpoint Plant status SW version Time programmes The Schedules menu (only for controllers with time switches) can be used to enter the 7-day and date programme. 7-day programmes > Monday 07:00 Stage I Monday 17:00 Off Date programmes > 01.10.96 24.12.96 03.01.97 Indication / Display LEDs The display comprises two lines of 40 characters each. The eight available LEDs indicate the current controller status. A maximum of two analogue and six digital outputs, or eight digital outputs can be indicated. The intensity of the analogue value LEDs ranges from 'Off' to full brightness. For digital data points, the LED is 'Off' for Inactive and 'On' for active. A specific data point from a given controller can be assigned to each LED in the engineering phase. An LED which has not been engineered in this way remains off. Siemens Building Technologies CA2N3292E / 03.1999 Landis & Staefa Division 3/6

Alarm LED In the event of an active alarm, the alarm LED remains 'On' steadily. It goes out when there are no further active alarms. Operation Hot keys A B Any two data points (A1 and A2 / B1 and B2) from a controller can be assigned to each of the keys A and B. The values A1 and B1 (directly above the A and B keys in the display) appear in the Start-up display. When one of the two keys is operated, the display changes to show the second value (A2 or B2), which is marked with an asterisk (*) and remains in the display for five seconds. Unless access was denied during engineering (in which case modification is not possible), the value can be adjusted with the + and key before the 5-second display period elapses. Any value not defined during engineering will be indicated by two dashes ( ). Holding down the A or B key for two seconds produces a display showing the device and object from which the value assigned to A1/A2 or B1/B2 originates. The hot keys are typically used for measured value and setpoint. Editing keys + esc These keys can be used to enter or modify values. Holding either of the two keys down for approximately two seconds accelerates the rate at which the value changes. The enter key is used to acknowledge and transfer a new or modified value (mode, setpoint etc.) and to activate a menu option. This key is used to move back through the menu structure to the previous level. It may also be used to abandon an input procedure without making any changes. Pressing this key repeatedly always leads back to the Start-up display. Navigation keys These cursor control keys are used to select an option from a menu, or to select an input field. These cursor control keys are used to move to the next screen of a menu or display where there is more information than can be displayed on the available two lines. menu This key allows the user to move from the Start-up display to the Device list / BCO settings main menu. The same key can be used to jump from any menu to the Start-up display. Keys for general operation mode This key is used to jump from any display directly to the Plant status menu, but only if there are no unacknowledged alarms, as these cause the operator terminal to switch to the Alarm summary. The alarm must be acknowledged before the user can return to the Plant status menu. The mode key allows a jump from any display directly to the Schedules menu. Here too, any unacknowledged alarms take precedence (see above). This function is active only in controllers with a time switch. In the event of an unacknowledged alarm, this key can be used to disable the audible alarm signal. The relevant Alarm summary is then displayed. The alarm can be acknowledged in this menu, which also provides a more detailed description of the alarm. CA2N3292E / 03.1999 Siemens Building Technologies 4/6 Landis & Staefa Division

Technical data Power supply Supply voltage Low voltage (SELV) Nominal voltage AC 24 V, 50/60 Hz Admissible voltage tolerance +15/ 10 % Power consumption Max. 100 ma Connection Connection Service cable Two RJ45 sockets 3 m, with RJ45 connection at each end (comms and power) Communication LON with BACnet protocol Connection 2-wire (comms only without AC 24 V) Max. cable length 1100 m (unscreened) Bus termination On front, set by switch Weight / Dimensions Weight excluding packaging Dimensions (W x H x D) 0.64 kg 205 x 123 x 37 mm General ambient conditions Safety Usage For indoor use Temperature range Operation 5... 45 C Storage 25... 70 C Ambient humidity 10... 90 %rh, non-condensing Product safety EN 61010-1 Electrical safety SELV-E (PELV to IEC 364-4-41) Conformity This product meets the requirements for CE marking Connection Pin connections 60324 60325 1 2 3 4 5 6 7 8 LS NS LON AC 24 V Bus termination switch Sockets (2) for power supply and LON bus Dimensions All dimensions in mm 205 37 60334 123 Siemens Building Technologies CA2N3292E / 03.1999 Landis & Staefa Division 5/6

Fixing wire clip 34 3 Cut-out in control panel door 60337 201 60336 119 1...3 1999 Siemens Building Technologies Ltd. Replaces R21-06.20 CA2N3292E / 03.1999 Siemens Building Technologies 6/6 Landis & Staefa Division