Using Measurement & Automation Explorer (MAX) with VXI

Similar documents
Calibrating FieldPoint Analog Input Modules with Calibration Executive

VME-GPIB Installation and User Guide

Sample. LabWindows TM /CVI TM Core 1 Exercises Manual

LabVIEW DSP Module. Contents. Introduction RELEASE NOTES. Version 1.0

INSTALLATION INSTRUCTIONS LFH160 Cable

NI 653x Cable Adapter

Sample. LabWindows TM /CVI TM Core 1 Course Manual

Power Analyzer Firmware Update Utility Version Software Release Notes

Caution Electrostatic discharge can damage your controller. To avoid such damage, handle the controller only in a proper ESD-controlled environment.

FP-2000/2010 FieldPoint Quick Start Guide

LabVIEW DSP Module Release and Upgrade Notes

Getting Results with the NI PXI-6585R

Getting Started with R Series Intelligent DAQ

TBX-96 TERMINAL BLOCK

Getting Started with R Series Multifunction RIO

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

NI SPEEDY-33. '7 NATIONAL INSTALLATIONGUIDE. P~ClCl J ~ Ig~~!1 "INSTRUMENTSN. 1~~~~~~g~~lm.OOOQ{JOOO,

NI SMB-2145/2146/2147/2148

FP-1600 FieldPoint Quick Start Guide

VXI-8340 SERIES INSTALLATION

VISA, SICL, VISA COM,

Using VME Devices with NI-VXI or NI-VISA

Getting Results with the NI 5752R

Sample. LabVIEW TM Core 1 Exercises. Course Software Version 2010 August 2010 Edition Part Number B-01. LabVIEW Core 1 Exercises

FP-PS-4. Features. Installation

You need the following to set up and use your terminal block:

NI 9213 Calibration Procedure

Safety. Introduction

Uploading protocols and Assay Control Sets to the QIAsymphony SP via the USB stick

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E

Dataliner Message Displays Using DL50 Slaves with a DL40 Master

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E

Sample. LabWindows TM /CVI TM Basics I Course Manual

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

Getting Started with NI-Motion for NI 73xx Motion Controllers

Using Your NI Software for DOS or Windows 3 with Windows 95/98

NI-VXI Software Manual for the VXIpc 800/700 Series

I 2 C and SPI Protocol Triggering and Decode for Infiniium 8000 and Series Oscilloscopes

VXI/VME-PCI8000 SERIES

SCXI HIGH-VOLTAGE 8 4 MATRIX TERMINAL BLOCK

How to Troubleshoot System Problems Using an Oscilloscope with I 2 C and SPI Decoding APPLICATION NOTE

VI Logger. Getting Started with VI Logger. Getting Started with VI Logger. May 2003 Edition Part Number B-01

Troubleshooting Ethernet Problems with Your Oscilloscope APPLICATION NOTE

NI 6521 Specifications

LabVIEW DataFinder Toolkit

Integrating CaliberRM with Mercury TestDirector

Training Notes Unity Real Time 2

USER GUIDE SC-2075 SIGNAL CONDITIONING ACCESSORY

100GBASE-SR4/TDEC Compliance and Characterization Solution

Instructions. (For 6180 Industrial Computers) Installing a Processor Upgrade

Instructions. (For 6180 Industrial Computers) Applications. Overview & Safety

FieldPoint. FP-1000/1001 FieldPoint Quick Start Guide. Install the Network Module Mount the module on a DIN rail. What You Need to Get Set Up

Conferencing and Recording

Keysight Technologies FPGA Implementation of a LUT-Based Digital Pre-Distortion Using M3602A FPGA Design Environment.

Purchasing. Operations 3% Marketing 3% HR. Production 1%

VXIPC 800/700 SERIES FOR WINDOWS 95/NT

TekExpress 10GBASE-T Automated Compliance Software Features & Benefits

Upgrading Luminex IS 2.3 to Bio-Plex Manager 6.1 Software. For technical support, call your local Bio-Rad office, or in the US, call

Keysight Technologies 8163B Lightwave Multimeter 8164B Lightwave Measurement System 8166B Lightwave Multichannel System.

NI CAN Demo Box. NI CAN Demo Box User Guide. Power supply (+9 VDC to +12 VDC) 68-pin Multifunction Data Acquisition board

U85026A Detector 40 to 60 GHz

PRODUCT DATA. Reporting Module Type 7832

Keysight Technologies I 2 C and SPI Protocol Triggering and Decode

FB-DIMM Commands/Data and Lane Traffic Verification

NI SD Card Memory Module

END-OF-SALE AND END-OF-LIFE ANNOUNCEMENT FOR THE CISCO MEDIA CONVERGENCE SERVER 7845H-2400

Supplier Responding to New Products RFP Event

Troubleshooting Ethernet Problems with Your Oscilloscope APPLICATION NOTE

Agilent Modern Connectivity Using USB and LAN I/O Converters

PCI Express Protocol Triggering and Decode for Infiniium 9000 Series Oscilloscopes

Cisco Extensible Provisioning and Operations Manager 4.5

Graphical System Design Platform. NI LabVIEW. Test and Measurement Industrial Measurements and Control Embedded Design. ni.

NI CardBus-8310-to-PXI Expansion Kit

Cisco Voice Services Provisioning Tool 2.6(1)

Keysight Technologies

Agilent IntuiLink for Infiniium Software for the Agilent Technologies Infiniium-Series Oscilloscopes. Getting Started With Agilent IntuiLink

Fast 3D EMC/EMI Scan with Detectus Scanning System and Tektronix Real Time Spectrum Analyzers CASE STUDY

For NI PXI and NI SCXI Switch Modules

VXI-MXI-Express Series

Keysight Technologies RS232/UART Protocol Triggering and Decode for Infiniium Series Oscilloscopes. Data Sheet

Global entertainment and media outlook Explore the content and tools

Quintiles vdesk Welcome Guide

UM0401 User manual. User manual for eight bit port expander STMPE801 demonstration board. Introduction

Reference Guide. (Catalog Number 1785 series) Introduction

Updates to Plastic Molding and Co-injection Modules (Catalog Numbers 1771-QDC and 1771-QI)

Testplan Development on CVI Labwindows with TS-5400 PXI Series

RTPA2A. TekConnect probe adapter for real-time spectrum analyzers. Tektronix high-performance probing solutions. Applications. Notice to EU customers

Tektronix Logic Analyzer Probes P5900 Series Datasheet

Application Note. Overview. Hardware Requirements. Software Requirements

Cisco CallManager 4.0-PBX Interoperability: Lucent/Avaya Definity G3 MV1.3 PBX using 6608-T1 PRI NI2 with MGCP

Programming Note. Agilent Technologies Quick Reference Guide For the 8757D/E Scalar Network Analyzer

Cisco Unified CallConnector for Microsoft Office Quick Reference Guide 1

END-USER MANUAL. Sennheiser HeadSetup Pro

I 2 C and SPI Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes

Keysight Technologies Using PXI Modules, I/0 Libraries and IVI Switch Drivers with National Instruments Switch Executive.

AC/DC (120V) Input Module Cat. No IAD Series C

HeadSetup Pro Manager

Keysight N8843A I3CSM Protocol Trigger and Decode for Infiniium Oscilloscope. Data Sheet

NI-DAQ mx Base 1.x. Contents GETTING STARTED GUIDE

Patent Portfolio Overview July The data in this presentation is current as of this date.

Transcription:

Using Measurement & Automation Explorer (MAX) with VXI Introduction Measurement & Automation Explorer (MAX) provides access to all your National Instruments DAQ, GPIB, IMAQ, IVI, Motion, VISA, and VXI devices. With MAX, you can configure your National Instruments hardware and software, add new channels, interfaces, and virtual instruments, execute system diagnostics, and view the devices and instruments connected to your system. MAX installs automatically with NI-VISA version 2.5 or higher or NI-VXI version 3.0 or higher. MAX is available only for Win32-based operating systems. In this course manual addendum, you will examine MAX and use it to configure a VXI system. Measurement & Automation Explorer, NI-VXI, NI-VISA, National Instruments, and ni.com are trademarks of National Instruments Corporation. Product and company names mentioned herein are trademarks or trade names of their respective companies. 323010A-01 Copyright 2000 National Instruments Corp. All rights reserved. December 2000

Exercise 1 Objective: To examine MAX. MAX icon 1. To launch MAX, double-click the desktop icon or select Start»Programs»National Instruments»Measurement & Automation. The MAX interface appears as shown below. 1 2 3 1 Configuration Tree 2 Configuration View 3 Task List Figure 1. The MAX Interface VXI Course Manual Addendum 2 ni.com

2. After launching, MAX displays the dialog box shown below. Use this dialog to configure MAX to search for new devices each time you launch it or only when you refresh (<F5> or View»Refresh). Also, you can configure the dialog box to appear the next time you launch MAX. Note If you select not to search for new devices when MAX launches, MAX will not show the updated system view if there were any changes to it. Remember to refresh after making any changes. To change these preferences, access this dialog box by selecting Tools»User Preferences. Configuration Tree Figure 2. MAX User Preferences The Configuration Tree shows a hierarchical view of the instruments in your system. In the setup shown in Figure 1, MAX shows a VXI system with one VXI chassis (Frame 0), a National Instruments VXIpc-870 embedded controller, a Wavetek 1375 arbitrary waveform generator, and a National Instruments MIO-64E-1 multifunction data acquisition board. The following MAX toolbar appears when you select the VXI system in the Configuration Tree: Properties Displays properties of the selected VXI system. Run VXI Resource Manager Runs VXI Resource Manager (Resman) for the selected VXI system. Note Because NI-VXI 3.0 or higher supports multiple VXI systems, properties apply to the currently selected VXI system. Resman also runs for only the selected VXI system. To run Resman for all VXI systems, select Tools»NI-VXI»VXI Resource Manager. National Instruments Corporation 3 VXI Course Manual Addendum

System Properties 3. Examine the properties for the selected VXI system by clicking on the properties button from the toolbar or right-clicking on the particular VXI system and selecting Properties, as shown below. Figure 3. System Properties for VXI System 0 In addition to viewing the properties, you can also launch Resman for this VXI system, access the hardware configuration for the system controller, and create a new VME device. VXI Course Manual Addendum 4 ni.com

4. Examine the VXI System 0 properties. Right-click on VXI System 0 and select Properties. The properties dialog box appears as shown below. Figure 4. Properties Dialog for VXI System 0 This dialog box reports the device status. If there is a problem with this system, you can access online help by clicking on the Troubleshoot button. The properties dialog box also shows you the device type and whether the device is enabled. National Instruments Corporation 5 VXI Course Manual Addendum

5. Select the Settings tab, shown below. Figure 5. VXI System 0 Settings Use this tab to change the VXI system number and Resman delay for this specific VXI system. VXI Course Manual Addendum 6 ni.com

6. Select the Interrupt Levels tab, shown below. Figure 6. VXI System 0 Interrupt Levels Use this tab to assign interrupts to specific controllers and set the mapping for each interrupt level. In the Assignment field, you can select four options from the pull-down menu: Auto Automatically assign to a programmable handler, usually the local controller. Local Assign the interrupt level to the local controller. Choose LA Choose the Logical Address of the controller that will handle this interrupt. None Do not assign the interrupt level to any controller. In the Mapping field, you can select three options for mapping the interrupts: Auto Auto mapping (maps toward root if root is the handler; otherwise, does not map). Source Map away from the root (source the interrupt). None Do not map. National Instruments Corporation 7 VXI Course Manual Addendum

7. Click on the Assist Me button. The Interrupt Levels dialog box appears, as shown below. Figure 7. VXI System 0 Interrupt Assistant If you are not sure how to set the interrupt assignments and mapping, use Interrupt Assistant for detailed descriptions of all the settings and to set the options separately for each interrupt. VXI Course Manual Addendum 8 ni.com

System Resources Window Figure 8. VXI Address Map View System Resources Window The System Resource Window shows the registers/address space requested by various devices in A16, A24, and A32 space. In this particular setup, the two devices have registers in A16 and A24 address space, and the system controller (VXIpc-870) has registers in A16 and A32 address space. Look carefully at the ranges being used in A16 address space by each instrument. Recall the formula for the base of these 64 byte (0x40) windows: base address = 0xC000 + (logical address * 0x40) Task List The Task List includes an interactive task list to guide you through VXI system configuration and other basic tasks. The task list content changes according to the interface you selected (VXI, GPIB, NI-DAQ, etc.). National Instruments Corporation 9 VXI Course Manual Addendum

Device Properties in MAX 8. You can examine properties of devices in the system by right-clicking on a device and selecting Properties or highlighting the device and clicking on the Properties button on the toolbar. Right-click on the Wavetek 1375, as shown below. Figure 9. Right-Clicking on a Device to Examine Its Properties Notice that MAX displays the information about the VXI device in the Attributes window. Here you can see that the Wavetek 1375 is at Logical Address 1, the manufacturer ID is 4094, and the device resides in slot 2 in your VXI chassis. Also, this window shows the resources used by the Wavetek 1375. The A16 space for this device contains the Configuration Registers. The A24 space is scratch pad RAM for storing waveforms. VXI Course Manual Addendum 10 ni.com

Configuring Devices in MAX You can configure some VXI devices (for example, all National Instruments MITE-based controllers) through software. You can use MAX to configure these devices. 9. Right-click on the VXIpc-870 controller in the Configuration Tree and select Hardware Configuration. The dialog box shown below appears. Figure 10. VXIpc-870 Hardware Configuration through MAX General Use this tab to load and save configurations from file. This is useful when backing up your system. Device Use this tab to configure the MITE-based device Logical Address and interrupt configuration. Shared Memory Use this tab to set up the shared memory. For more details on shared memory, see the online help or visit the National Instruments Web site to download the shared memory application note. VXI Bus Use this tab to configure how MITE-based controllers interface to the VXI bus (timeout, etc.). PCI Use this tab to configure the MITE chip (which resides on the PCI bus, hence the tab name). Watchdog Use this tab to enable the watchdog timer. SMB Use this tab to configure the front panel SMB connectors to provide or source clocks and triggers. National Instruments Corporation 11 VXI Course Manual Addendum

Configuring MAX 10. You can customize MAX to meet your system needs. Select Tools»NI-VXI»VXI Options to get the VXI options dialog box shown below. Figure 11. VXI Options VXI Course Manual Addendum 12 ni.com

11. To set the NI-VISA options, select Tools»NI-VISA»VISA Options. Use this dialog box to tell the driver to run Resman on startup. You can also set the VISA options shown below. Figure 12. VISA Options Help in MAX MAX brings online support to a new level. The MAX help files feature common questions gathered from several years of technical support calls, as well as helpful hints, references to application notes, and procedures for setting up a large variety of systems. If MAX resides on a networked computer, you have a Web link from MAX to the National Instruments Technical Support home page and the NI-VISA and NI-VXI home pages. You can access the following help resources through links in MAX. Online Problem Solving and Diagnostic Resources KnowledgeBase A searchable database containing thousands of frequently asked questions (FAQs) and their corresponding answers or solutions, including special sections devoted to our newest products. The database is updated daily in response to new customer experiences and feedback. Troubleshooting Wizards Step-by-step guides lead you through common problems and answer questions about our entire product line. Wizards include screen shots that illustrate the steps being described and provide detailed information ranging from simple getting started instructions to advanced topics. National Instruments Corporation 13 VXI Course Manual Addendum

Product Manuals A comprehensive, searchable library of the latest editions of National Instruments hardware and software product manuals. Hardware Reference Database A searchable database containing brief hardware descriptions, mechanical drawings, and helpful images of jumper settings and connector pinouts. Application Notes A library of more than 100 short papers addressing specific topics such as creating and calling DLLs, developing your own instrument driver software, and porting applications between platforms and operating systems. Software-Related Resources Instrument Driver Network A library of hundreds of instrument drivers for control of standalone instruments via GPIB, VXI, or serial interfaces. You also can submit a request for a particular instrument driver if it is not in the library. Example Programs Database A database with numerous example programs for National Instruments programming environments. You can use them to complement the example programs already included with National Instruments products. Software Library A library with updates and patches to application software, links to the latest versions of driver software for National Instruments hardware products, and utility routines. 12. Examine some of the help resources available in MAX. Open Help»HelpTopics»NI-VXI. Suppose you want to configure a multimainframe VXI system. From the Contents tab, select How Do I?»Configuration. Scroll through the list until you see the entry for Configure a multiple-mainframe system. Select this item. You can resize this window and read about the issues involved with this type of configuration. Notice the reference to an application note available from National Instruments web page. You can easily download this application note by selecting Help»National Instruments on the Web»VXI Home Page. On this page is a link to the application note download page. VXI Course Manual Addendum 14 ni.com

Software Information 13. Another helpful MAX feature is its ability to gather and display information about your system for your reference. Expand the Software folder in the Configuration Tree by clicking on the plus (+) sign to the left of the Software folder. The window shown below appears. Figure 13. The MAX Software Information In this window, you can view the versions of all pertinent National Instruments drivers in your system. This information is very important when troubleshooting a system. End of Exercise 1 National Instruments Corporation 15 VXI Course Manual Addendum

Exercise 2 Objective: To add a fictitious VME device to your system. It is often necessary to use a VME device in a VXI system. Because the VME specification does not implement configuration registers, if you want to use VME devices in your VXI system, you must tell the NI-VXI driver what resources a particular VME device uses. In a VXI system, Resman uses the VXI configuration registers to identify each VXI device, its device class, model and manufacturer, and address space requirements. Because VME devices do not have the standardized VXI register set, you must manually enter the information normally encoded in this VXI-defined register set for your VME device before Resman can properly configure it. You can use MAX to add a VME device to your system manually. 1. Launch MAX if it is not already running. Expand the Devices and Interfaces folder in the Configuration Tree and right-click on VXI System 0. From the pop-up menu, select Create new VME device. The Create New window appears as shown below. Figure 14. Create New VME Device Window VXI Course Manual Addendum 16 ni.com

Because you can have multiple VXI systems in the same configuration, there is a System Number pull-down menu. Because there is currently only one VXI system, keep the VXI System 0 selection. Next, assign this device a pseudo logical address between 255 and 512. (Select any number in this range.) Finally, specify the frame and the slot within the frame where this device resides. The only frame in your system is Frame 0, so keep this selection. Because this VME device does not really exist, you may select any slot you want. 2. Click on Next > button to continue. In the next window (shown below), you can create a new VME profile. Figure 15. Create a New Profile Window National Instruments Corporation 17 VXI Course Manual Addendum

3. Use the pull-down menu in this window to select previously created VME profiles or create a new one. A profile describes the manufacturer ID, model code, and resources that this VME device requires. No VME profiles are created yet, so click on Next > to create one. Name your VME device My VME Device, as shown below. Figure 16. Profile Name, Manufacturer ID, and Model Code You can select the manufacturer of this fictitious device through the pull-down menu. The manufacturer is Act Tech. VXI Course Manual Addendum 18 ni.com

4. Select the pull-down menu for a list of known VME devices manufactured by Act Tech. This list is empty, so you need to add this new device yourself. Select the... button next to the pull-down menu. Figure 17. Adding a New Act Tech VME Device 5. Select New and fill in the parameters shown below. Select OK. Figure 18. The New VME Model From Act Tech 6. The new VME device appears in the Model Name Editor window. Select OK again to confirm the change and return to the Device Wizard. National Instruments Corporation 19 VXI Course Manual Addendum

7. Use the pull-down menu and select the device you just added. Your screen should appear as shown below. Figure 19. Device Wizard Showing New VME Model and Manufacturer 8. Select the Next > button to add resources used by this device. VXI Course Manual Addendum 20 ni.com

9. Click the Add button and add an Address Range in A24 space. In the Setting column, enter the range of registers this device uses. Type in the value 0x0-0x100000 and press <Enter>. Figure 20. Requested Address Space for the New VME Device National Instruments Corporation 21 VXI Course Manual Addendum

10. Select Next > and Finish to complete the process of adding a VME device. When you open MAX, notice that your VME device has an exclamation point. This means you need to run Resman again to reconfigure the system. Your system should appear as shown below. Figure 21. Final View 11. Run Resman and notice that the VME device remains in the system. You can edit the configuration parameters of this fictitious VME device through its properties. You can access the Properties menu by right-clicking on the VME device or selecting Tools»NI-VXI»VME Profiles. In the VME Profiles window, you can manipulate the profiles you created. You can remove them, add a new one, or change their properties. 12. To remove the VME device, right-click on it and press <Delete>. The device disappears, but its profile is still available for future use. End of Exercise 2 VXI Course Manual Addendum 22 ni.com

Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100 Worldwide Offices Australia 03 9879 5166, Austria 0662 45 79 90 0, Belgium 02 757 00 20, Brazil 011 284 5011, Canada (Calgary) 403 274 9391, Canada (Ottawa) 613 233 5949, Canada (Québec) 514 694 8521, China (Shanghai) 021 6555 7838, China (ShenZhen) 0755 3904939, Denmark 45 76 26 00, Finland 09 725 725 11, France 01 48 14 24 24, Germany 089 741 31 30, Greece 30 1 42 96 427, Hong Kong 2645 3186, India 91805275406, Israel 03 6120092, Italy 02 413091, Japan 03 5472 2970, Korea 02 596 7456, Mexico 5 280 7625, Netherlands 0348 433466, New Zealand 09 914 0488, Norway 32 27 73 00, Poland 0 22 528 94 06, Portugal 351 1 726 9011, Singapore 2265886, Spain 91 640 0085, Sweden 08 587 895 00, Switzerland 056 200 51 51, Taiwan 02 2528 7227, United Kingdom 01635 523545