Installation & Operation Manual Revision 2

Similar documents
USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

Installation & Calibration Manual

Installing Keypad and Backplate

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

7561-PSD Manual Portable Battery Powered Indicator

DEFAULT SCREEN. Button and Screen Layout DRILLING WIDTH TARGET RATE HOPPER NUMBER CROP NAME DRILLING ACTION CROP NUMBER. HOPPER selection POWER On/Off

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Installation & Calibration Manual

Defender IM4-RFID Lift Truck Impact Monitoring with RFID Card Reader Operator Access Control with Automated Programmable OSHA Safety Check RF Wireless

ivisibility (Keypad Operator Access Control Series) Lift Truck Onboard Automatic Detection / Recording of All Operational Downtime Events

W3-H Waterproof Keypad/Reader/Controller

Features: Contents: If you are missing any of the above components please contact Racepak at

A Axis M-Functions Level 1 A Axis Standard A Axis SMT Level 2. Each console includes the following:

LCI User Manual mantracourt.com

Temperature Controller

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

Installation & Calibration Manual

6222 Two Door Module Technical Operations Manual

Calibration & Connectivity

W3-M. Metal waterproof standalone access control/reader. User Manual

M260 Load Cell Amplifiers

Voltage Sag Simulator

RAIN BIRD RC-4Bi, RC-7Bi, RC-1260Bi SERIES INSTRUCTION MANUAL

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

Digital Keypad Introduction

Ag Leader Technology. DirectCommand Installation RoGator Model Years

Using the Multi-channel Display Feature of the Hardy 6000 Series

Operating instructions. Switching amplifier DN0210 DN / / 2015

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

D1265. Installation Guide. Touchscreen Keypad

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

Trademark Generation II Series Intercom System Installation and Operation Reference Guide

802B Compact, Precision and Small Precision

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

Stand-alone Proximity Access Control

Waterproof. Keypad/Reader/Controller

Temperature controller Ducted systems

DYNASCAN D-250 2D+ Ø DRO

DirectCommand Installation RoGator Model Year Ag Leader Technology

APEX Junior Cased Weighing Indicator/Controller

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Zone Pressure Touch (ZPT) Sensor - Standard Range

Revenue Grade NEMA 4X THE BYRAM. Electric Meter

Digital Bench Scale. Revision 1.2 August 24, Contents subject to change without notice.

VW2106 VW Readout Manual

Laboratory Switch Mode Power Supply Series. Instruction Manual

V8-80HS-1 SERIES OF HIGH-SPEED MOTORIZED ZOOM LENSES

CM-110SK Standalone Keypad Installation Instructions

High Performance Tension Controller HPTC Electrical Connection Manual

Safegard V4 Panel. Installation Datasheet. Safegard V4 Panel Installation Instructions and Datasheet release 1.7 August 2016

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

VE-53 Sensor Uniaxial / Triaxial Surface and Downhole Velocity Sensor. Operation Manual

Operating instructions. Speed monitor D / / 2014

Model 720 Electromechanical Hour Meter

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Contents 1 Warnings, Cautions, and Notes Description Features... 1

DCS Series. Digital Counting Scale. Setup Manual

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

2000 Series e/em Style Keypad Installation and Programming Manual

TR150 Digital Readout Unit SL755. Impact Test Equipment Ltd & User Guide. User Guide

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

UC-2000 Installation Manual Unicorn Computers Technology Limited

Supplementary operating instructions for your air curtain system Controller TMC 500

VIDI-AC-2CS Access Controller/ Reader

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

Installation and Operation Manual SPC1

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

Belt-Way Conveyor Belt Scales for Every Application

LCI Load Cell Junction Box with Fault Monitor

Series 3000 User Manual and Product Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

LCM SYSTEMS. TR150 Portable Battery Powered Indicator. Instruction Manual. Software version V2.XX

Contents. Temperature & Process Measurement Indicators Setup Guide

DAW 8/28/09. TITLE Specification I2R 120/240 RR 120V AC Split Phase Surge Protector PAGE 1 of 9 REVISIONS

Gas Discharge Tube. Indicator Light(2) UL Parallel 1600 V N N / PU-20KS10KTTN. UL Series 1600 V N N 15 A PU-20KD10KTTN

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

CDD Carbon Dioxide Transmitter

Robocolor II System. users guide

UniScan. Impro UniScan Controller INSTALLATION MANUAL

Installation / Control Technique

PAC1 Door Access Controller

CII: Current Input, Isolated

LD-RTD / LD-TC Temperature Controller

EnCell Battery Cell Monitor

User Manual. Waterproof Weighing Scale. ELW Plus / ESW Plus ELW Plus Wipower

Quick Start Installation Guide

PAC1 Door Access Controller

AP41 / AP81 SERIES TIME SWITCHES

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Sigma XT Ancillary Board (K588)

M2 OLED Temperature Monitor Instructions PN 1841

Transcription:

MULTI-C1 IN-PARLOUR FEEDING Installation & Operation Manual Revision 2 PAGE 1

INDEX Overview Setting Up 3 Parlour Parameters - Parlour Size - Feeder Type - Pulse/Portion Time 4 4 4 Manufacturer Feed Dispenser Pulse/Portion Times - Portion Time - Calibrating Feeders - Meal Time 5 5 5 Additional Parlour Parameters - Enticement - Feed Group Size - Quick Feed - Ration Mode - Auto Changeover - Parallel Feeding 7 7 8 8 8 8 General Settings - Time - Date - Contrast - Global Portion Adjust - Erase Cow Entering Cow Records 9 9 9 9 9 10 Feeding - Ration Feeding - Feeding By Cow Numbers 11 12 - Shift Cow Numbers Up - Shift Cow Numbers Down - Clear Cow Numbers - Flat Rate Feeding 13 13 13 13 Function Button Installation Feed Dispenser Wiring System Wiring Product Specification 14 15 16 17 PAGE 2

OVERVIEW The Multi-C1 control unit provides the user with a complete all round solution to in-parlour feeding. The Multi-C1 can be configured to be used as a manual ration feeding system or a cow memory feeding system with the capability to connect to automatic identification hardware. The Multi-C1 controller works in conjunction with our remote 20 channel feeder interface unit. Multi-C1controller features: - Control up to 40 stalls per side (herringbone parlour). - Individual feed or batch feed a side option. - Calibrate individual auger motors. - Cows fed and feed dispensed counters. - Single ration drop enticement option. - Quick Feed immediate dispensing option. - 9999 cow storage. PAGE 3

SETTING UP PARLOUR PARAMETERS The following procedures will help you quickly get the Multi-C1 controller up and running. Press the button to enter the set up menu. Use the and buttons to navigate through the different screens until you reach the Parlour Settings 1/2 screen as shown below. Use the and buttons to move through the different parameters. Parlour Size To edit the No. Stalls parameter simply highlight the parameter and then enter the parlour size using the numeric keypad. Maximum number of stalls allowed is 40. Feeder Type The feed dispenser type can be selected by highlighting Feeder Type and using the button to choose either Pulse or type feeders. Pulse/Portion Time The time it takes the system to deliver a portion of feed can be set by highlighting either Pulse Time or Portion Time depending on the feeder type selected. For Pulse Time the time entered in seconds will relate to the length of time the feed dispenser solenoid is energised and de-energised. For Portion Time the time entered will relate to the running time of the auger motor per portion. Maximum allowed portion time is 25.0 seconds. PAGE 4

Manufacturer Feed Dispenser Pulse/Portion Times feeder portion size is 500g for times below. Make Type Run Time (seconds) ATL Ration Master Hosier Alfa Laval 2 Simplex Alum Westfalia EZ Westfalia M Westfalia EP Master Orby Surge Gascoigne Simplex Galv EB Somerset Alfa Laval 4 Alfa Laval 24 Vaccar Pulse Pulse Pulse Pulse Pulse Pulse Pulse 2 1 1 2 2 12 2 2 11 1 12 6 6 1 1 1 15 11 Portion Size The Portion Size relates to the amount of feed dispensed during the pulse/portion time. This is by default set to 500g but can be adjusted up to 1000g. Meal Time The Meal Time feature allows feeding over a pre-set time. If for example Meal Time is set to 5 minutes then all rations fed to a side regardless of size will be split over the 5 minute period normally in 1 second drops. PAGE 5

Calibrating Feeders The Multi-C1 controller allows individual stall calibration on auger type feed dispensers. Calibration can be accessed from the Parlour Settings 1/2 screen by highlighting -Calibrate Feeders- and pressing the button. Calibrating the feed dispensers allows the system to compensate for any feed dispensers that drop more or less feed than the average dispenser because of age or different parts. Calibrating essentially equalizes the feed portions between all the feed dispensers. Side to calibrate - use or to change. Stall - use or to change. Feed Weight. To calibrate a stall first select the side and then the stall number. Make sure the feed dispenser hopper and auger is full of feed and the feeding trough empty. Press the button to dispense one portion. Go to the stall and collect the dropped feed and weigh it. The weight should be no more than +/- 20% out from the desired portion size, if the deviation is greater than 20% then readjust the Portion Time in the Parlour Settings 1/2 page. Hint... To obtain better accuracy during calibration drop three portions in one go and weigh the combined weight and then divide that figure by three. PAGE 6

ADDITIONAL PARLOUR PARAMETERS Below is a summery of Parlour Settings 2/2 page parameters. Enticement The Enticement parameter when set to Yes will dispense one portion of feed to the first stall as soon as the user inputs the first feed amount or cow number into the controller. This feature acts as the name suggests as an enticement to the first cow to enter the stall line and proceed down to the first stall. Pressing the button toggles this parameter. Feed Group Size The Feed Group Size parameter sets the system to operate groups of feed dispensers. This is a particularly useful feature if the transformer powering the feed dispensers cannot cope with operating a full line of feeders in one go. Pressing the button toggles between 5, 10 or 20 feed dispensers. If for example the parlour has 8 feed dispensers in total down one side and the Feed Group Size parameter is set to 5, then when feeding commences the first five feed dispensers will operate and then when they have finished the last three feed dispensers will operate. Alternatively, if the parlour has 12 feed dispensers in total down one side and the Feed Group Size parameter is set to 20, then when feeding commences all feed dispensers will operate. Feed Group Size does not function if Quick Feed is enabled. PAGE 7

Quick Feed The Quick Feed parameter when set to Yes will operate the feed dispensers immediately after the user has input a ration amount or cow number for a stall. If the Quick Feed parameter is set to No then the system will wait until the user has input an entire side of ration amounts or cow numbers before commencing feeding. Pressing the button toggles this parameter. Ration Mode The Ration Mode parameter sets the controller into feeding ration amounts only when manually feeding shown by the icon on the feeding screen when this parameter is set to Yes. If the Ration Mode parameter is set to No the controller will accept only cow numbers when manually feeding. This is shown by the icon on the feeding screen. Use the button to toggle this parameter. If the Auto-id parameter is set to Yes on the Auto-id Settings page then Ration Mode will always revert back to No. Auto Changeover Selecting Yes will allow automatic side changeover when entering feed amounts or cows on a side has been completed. Selecting No will allows the user to manually select sides. Parallel Feeding Selecting Yes will allow both sides to potentially feed at the same time depending on how quickly a side is loaded and the speed of the feeders. Selecting No prevents a side from feeding until the other side has finished feeding. IF YES IS SELECTED PLEASE MAKE SURE THE FEED DISPENSER TRANSFORMER IS SUFFICIENT FOR THE LOAD. PAGE 8

GENERAL SETTINGS Below is a summery of the general settings page 1/1 parameters. Time System time in 24 hour format. Use keypad to alter. Date System date DD/MM/YY format. Use keypad to alter. Contrast Screen contrast adjustment. The contrast scale is 0 to 9 where 0 is the lightest and 9 is the darkest. Use numeric keypad numbers to select scale. Global Portion Adjust Portion feed amounts for all stored cows can be globally adjusted up or down using this feature. To toggle the + or - sign use the button. Use keypad to enter number of portions. Press to carry out feed adjustment. Erase Cow Cow records can be erased by entering in the cow number and pressing the button. PAGE 9

ENTERING COW RECORDS By default the system is set up to manually input cow numbers when feeding. If the cow icon is not shown on the feeding screen then please refer to the Ration Mode parameter in the settings menu and set to No. To scroll up through stored cow records use the button. To enter a new cow record simply highlight Cow No. and enter a cow number using the numeric buttons. Next use the button to highlight the Portions parameter. Enter the number of portions to be fed for one milking using the numeric buttons. Remember that the portion size is set in Parlour Settings 1/2 page. As you enter a portion amount the Total Meal amount will adjust to correspond with the portions being entered. If the system is connected to Auto-id hardware then use the button to highlight the Tag No. entry. This represents the number printed on the identification transponder of the cow. If you wish to add a warning message to the cow record use the button to highlight the Message entry. Use the numeric buttons to enter a pre-set message as listed below. 1. Dump milk 4. Segregate for vet 7. Inspect udder 2. Do not milk 5. Slow milker 8. Dry off 3. Segregate for AI 6. Nervous cow 9. High cell count 0. None Messages will be shown when cow number is entered during feeding. PAGE 10

FEEDING The Multi-C1 controller can feed either by entering ration amounts or by entering cow numbers which have pre-stored rations. The user can easily change the method of feeding by toggling the Ration Mode parameter in the Parlour Settings 2/2 page in the menu. Ration Feeding Portion Amount Stall No. Side Ration mode Feed in Kg. Use the or buttons to change the side from left to right. Use the or buttons to change the stall number. To enter a ration amount press a numeric button. The controller will automatically increment to the next stall. If you require to not feed a stall press the 0 button or the a stall. button to skip When all the stalls have been allocated rations the controller will prompt you to begin feeding by pressing the to feed the left side or the to feed the right side. Pressing the entered. button allows you to modify the rations previously PAGE 11

Feeding By Cow Numbers Cow Number Stall No. Side Cow No. Mode Feed in Kg. Use the or buttons to change the side from left to right. Use the button to change the stall number. To enter a cow number use the numeric buttons and then press the button to load that cow and move on to the next stall. To skip a stall use either the number is set to zero. To clear a cow number press the Pressing the or buttons but make sure the cow button. changes the screen to a stall list view as shown below. Cow Number Stall PAGE 12 Feed

You can use the edit cow numbers. Press the and arrows to highlight individual stalls to enter or to load the new cow number. When all the stalls have been allocated cow numbers the controller will prompt you to begin feeding by pressing the to feed the left side or the to feed the right side. Function Button The function button listed below. provides the user with some extra features as Pressing and then in the list view screen. will shift the cow numbers down by one stall Pressing and then the list view screen. will shift the cow numbers up by one stall in Pressing and then current side selected. will clear all the cow numbers from the Pressing and then will enable flat rate feeding. Flat rate feeding mode allows the user to feed a selected ration to all stalls on the current side selected. To exit flat rate feeding press the and then PAGE 13 buttons again.

INSTALLATION The Multi-C1 is normally installed on the bridge arm at the cow entry end of the parlour. The enclosure is strong and waterproof and should withstand the harsh working conditions of a milking parlour. The feeder interface relay cards are commonly housed in a separate enclosure that is fitted in a convenient place above the Multi-C1 controller. It is recommended that the feeder interface relay enclosure is fitted to a flat surface and the fixing holes located in each corner of the enclosures are used. It is not recommended to drill fixing holes inside the enclosure as this prevents the enclosure from being water resistant. The water-proofing of both enclosures is however dependant on how and where conduit or compression glands are fitted by the installation engineer. It is strongly recommended that the adapters should be fitted on the underside of the enclosures to eliminate the possibility of water entering and damaging the electronics. A little care during this part of the installation process will pay dividends in terms of the long term reliability of the control box. Cables required for Multi-C1 controller installation are: Twisted pair 22AWG screened cable (RS485 Data cable) Farnell Stock No. 1499576. RS Stock No. 409-167 Two core 0.5mm2. Recommend 2192Y. (Power cable). Please note the following: Cables used for this system (Data & Power) must not be routed next to A.C. power cables. Cable for feed dispensers needs to be selected according to the total current consumption on full load and the location to which the cable will be installed either conduit or trunking. Please refer to the manufacturers specification on the feed dispensers for selecting appropriate sized cable. Davlec Ltd. cannot be held responsible for damage caused by inappropriate wiring considerations. PAGE 14

Feed Dispenser Wiring The Multi-C1 feeder interface relay cards can accommodate most types of feeders at various voltages e.g., D.C. and A.C. The relay card has two Feeder + Transformer connection studs (M5) for the positive phase of the feeder power supply. There is also a Feeder - Transformer stud (M4) connection for the negative phase of the feeder power supply. Feeder Transformer + Feeder Transformer - Normally with a 12 volt D.C. system the negative connections on all the feeders are linked together and directly connected to the feeder transformer. The positive connection on each feeder is then connected to each corresponding output connector on the relay card. With a positive ground system all the positives from each feeder are linked together and the feeder power supply negative is connected to the Feeder + Transformer stud on the relay card. The Feeder - Transformer connector is then connected to the feeder power supply positive. All the negative connections from the feeders are connected to the corresponding outputs on the relay card. Each feed dispenser output on the relay card is protected with a 5 Amp thermal fuse. PAGE 15

System Wiring The image below shows the correct way to wire the Multi-C1 controller. 12v D.C. Power. Screen of Cable. Data (white) B Data (black) A The image below shows the wiring of the feeder interface relay card. Blue 12v - Brown 12v + Data (white) A Data (black) B The Manual Feed connection on the feeder interface relay card (shown above) connects directly to either the left or right push buttons located on the Multi-C1 base. When either the left or right button is pressed the feeder interface relay card will operate all outputs for the duration that the button is pressed. PAGE 16

PRODUCT SPECIFICATION Product Name Multi-C1 Product Family Feed Controllers Enclosure IP Rating 67 Material ABS Dimensions W 180mm L 180mm D Electrical Supply Voltage 12 volts D.C. Maximum Peak Voltage 15 volts D.C. Frequency N/A Maximum Current Load 1.5 Amps Protection 3 Amp 20mm Fuse (Relay PCB) Environmental Conditions Temperature 0 to 45 C Humidity 5 to 95% Location Indoor use only Approvals EMC Conformity to: EN 61000-6-1:2007, EN 61000-6-3:2007, EN 55022:2006 PAGE 17 60mm